Records from 1982 to 1996. Most recent: inspection, 7 May 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
7 May 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083925
17 May 1995
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438328
28 April 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362975
21 May 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385095
9 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944004
3 May 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259017
30 April 1992
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263001
28 April 1990
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233009
29 November 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243318
20 June 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893360
19 June 1987
Hull Examination · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332736
13 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006343
9 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317430
5 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304999
11 March 1986
Sanitary Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305468
12 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286771
26 February 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276523
Lifesaving
Issued 28 April 1994
Resolved
PROVIDE ABOARD VESSEL A MEANS OF LAUNCHING RESCUE BOAT AND DEMONSTRATE LAUNCHING IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR, OR REPLACE RESCUE BOAT WITH ACCEPTABLE SUBSTITUTE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Accommodation/Occupational Safety
Issued 28 April 1994
Resolved
INSTALL GASKET ON PORT LIGHT LOCATED ON STARBOARD SIDE OF O1 DECK.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994
Resolved
INSTALL AND MAINTAIN IN PLACE FLAME IMPINGEMENT SCREENS ON ALL RACOR FILTERS IN ENGINE ROOM AND MACHINERY SPACE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Navigation
Issued 28 April 1994
Resolved
PROVIDE SCREEN/SHIELD FOR MASTHEAD LIGHT TO SHOW ARC OF 225 DEG. FROM DEAD AHEAD TO 22.5 DEG. ABAFT THE BEAM ON EITHER SIDE OF THE VESSEL.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Lifesaving
Issued 28 April 1994
Resolved
PROVIDE ABOARD VESSEL A WORKING CLASS "A" EPIRB PRIOR TO VESSEL SAILING.
Condition: Unknown
Due 28 April 1994
Resolved 11 May 1994
Construction/Loadline
Issued 28 April 1994
Resolved
INSTALL BILGE ALARM SYSTEM AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 28 April 1994
Resolved
MAINTAIN VESSEL'S OFFICIAL LOG ABOARD VESSEL FOR A PERIOD OF ONE YEAR.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 28 April 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 28 April 1994
Resolved
PROVIDE ABOARD VESSEL A MEANS OF PROPULSION FOR RESCUE BOAT.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Lifesaving
Issued 28 April 1994
Resolved
PROVE PROPER OPERATION OF INSTALLED GENERAL ALARM SYSTEM.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 21 May 1993
Resolved
PAINT DRAFT MARKS PORT/STBD SIDE BOW.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Electrical
Issued 21 May 1993
Resolved
REPAIR PORT S/S GENERATOR J/W VALVE.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Accommodation/Occupational Safety
Issued 21 May 1993
Resolved
INSTALL LENSE COVER FOR LIGHT LOCATED IN MAIN DECK HEAD.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Electrical
Issued 21 May 1993
Resolved
REPAIR & TEST PORT S/S GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Electrical
Issued 21 May 1993
Resolved
INSTALL CIRCUIT BREAKER BLANKS IN 2 PANELS LOCATED ON BRIDGE (1) AND IN ENGINE ROOM (1).
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Engineering
Issued 21 May 1993
Resolved
REPAIR REMOTE F/O SHUT DOWN VALVE FOR STARBOARD F/O TANK.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Engineering
Issued 21 May 1993
Resolved
REPAIR PORT/STBD MAIN DIESEL ENGINE OVERSPEED TRIPS & TEST SAME IN PRESENCEOF CG MARINE INSPECTOR.
Condition: Unknown
Due 21 July 1993
Resolved 15 June 1993
Engineering
Issued 30 April 1992
Resolved
PROVIDE PRESSURE GAUGE FOR AFT THROTTLE CONTROL.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Electrical
Issued 30 April 1992
Resolved
RENEW PACKING IN CABLE STUFFING TUBES PENETRATING WTB IN ENGINE ROOM.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Construction/Loadline
Issued 30 April 1992
Resolved
REPAIR HOLES IN WATERTIGHT BLKD. IN ENGINE ROOM BY WTD.
Condition: Unknown
Due 30 May 1992
Resolved 20 May 1992
Documentation
Issued 30 April 1992
Resolved
PROVIDE COPIES OF ALL LOG ENTRIES AND DATES WITH INDICATIONS OF PAC ON BOARD AND NIMBER OF PAC. AS AVAILABLE FROM 01JAN91 THROUGH PRESENT.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Navigation
Issued 30 April 1992
Resolved
PROVE PROPER OPERATION OF VESSELS STEERING SYSTEM AND POWER FAILURE ALARM. THIS SYSTEM TO BE INSPECTED AND TESTED AND RESULTS LOGGED BY VESSELS MASTERBEFORE VESSEL GETS UNDERWAY.
Condition: Unknown
Due 30 May 1992
Resolved 20 May 1992
Engineering
Issued 30 April 1992
Resolved
PROVIDE PLUGS FOR FUEL OIL CONTAINMENT BOTH PORT AND STARBOARD SIDE.
Condition: Unknown
Due 30 May 1992
Resolved 20 May 1992
Accommodation/Occupational Safety
Issued 30 April 1992
Resolved
INSTALL GREASE TRAP ON ELECTRIC STOVE IN GALLEY.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Construction/Loadline
Issued 30 April 1992
Resolved
ENGINE ROOM AND GENERATOR ROOM VENTS NEED NEW WATERTIGHT CLOSURES.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Construction/Loadline
Issued 30 April 1992
Resolved
REPLACE MISSING GASKET ON WATERTIGHT DOOR ON POTR SIDE BRIDGE DECK.
Condition: Unknown
Due 30 May 1992
Resolved 20 May 1992
Lifesaving
Issued 30 April 1992
Resolved
PROVID ON BOARD USCG APPROVED FLARES TO REPLACE BRIZILIAN FLARES. AND PROVID A POTABLE WATERTIGHT CONTAINER FOR STOWAGE.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Fire Fighting
Issued 30 April 1992
Resolved
PROVID NEW FIREHOSE FOR PORT SIDE AFT FIRE STATION.
Condition: Unknown
Due 30 May 1992
Resolved 20 May 1992
Lifesaving
Issued 30 April 1992
Resolved
PROVID USCG APPROVED RESCUE BOAT OR PLATFORM.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Engineering
Issued 30 April 1992
Resolved
RENEW RPM GAUGE ON PORT MDE.
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Documentation
Issued 28 April 1990
Resolved
PROVIDE COPY OF CURRENT LOADLINE CERTIFICATE FOR VESSEL ONCE ISSUED BY ABS SURVEYOR, RIO DE JANEIRO, BRAZIL OFFICE.
Condition: Unknown
Due 28 April 1990
Resolved 28 April 1990
Lifesaving
Issued 28 April 1990
Resolved
PROVIDE ONBOARD CG APPROVED LIFERAFT FOR SIX(6)PERSONS TO REPLACE BRAZILIAN(SOLAS INSPT'D)RAFT. INSTALLATION TO BE IN ACCORDANCE W/46CFR94.15-10(A), (C)(2&4). NOTE:UNTIL CG APPROVED RAFT & INSTALLATION ARE ONBOARD, VSL IS RESTRICTED TO NOT MORE THAN TEN (10) TOTAL PERSONS ALLOWED ONBOARD.
Condition: Unknown
Due 28 April 1990
Resolved 28 April 1990
Documentation
Issued 28 April 1990
Resolved
PROVIDE ON BOARD VESSEL OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 46CFR35.35-70 AND 33CFR155.700
Condition: Unknown
Due 28 April 1990
Resolved 28 April 1990
Engineering
Issued 28 April 1990
Resolved
COMPLETE REPAIRS AND INSTALLATION OF SECOND (LOWER) AIR COMPRESSOR, DEMO- STRATE OPERATION OF BOTH COMPRESSORS TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 28 April 1990
Resolved 28 April 1990
Lifesaving
Issued 5 June 1986
Resolved
HAVE ALL LIFE RAFTS AND RELEASING GEAR SERVICED BY AN APPROVED COAST GUARD SERVICE FACILITY AND REINSTALL ABOARD.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
PROVIDE ON BAORD ONE (1) FIFTY (50) FOOT LONG 1 1/2 INCH APPROVED FIRE HOSETO REPLACE DEFECTIVE HOSE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
PROVIDE ONBOARD TWO (2) ALL PURPOSE COAST GUARD APPROVED 1 1/2 FIRE HOSE NOZZLES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 5 June 1986
Resolved
INSTALL SCREEN ON BILGE SUCTION IN FORE PEAK.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
REPAIR OR REPLACE IN OPERATIVE OIL PRESSURE GAUGE, WATER TEMPERATURE GAUGE AND CLUTCH OIL PRESSURE GAUGES FOR PILOT HOUSE CONTROL CONSOLE PANNEL.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 5 June 1986
Resolved
REPLACE MISSING DOGS ON WATERTIGHT DOOR, FROM GALLEY TO MAIN DECK.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986
Resolved
PROVIDE BREAK AWAY LINKS ON SEA PAINTER OF ALL LIFE FLOATS AND LIFE RAFTS.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Unknown
Issued 5 June 1986
Resolved
PROVIDE ONBOARD A VALID FCC CERTIFICATE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986