Records from 1982 to 1994. Most recent: inspection, 4 May 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation
Issued 1 March 1994
Resolved
PROVIDE ON BOARD LOG FOR PREVIOUS YEAR FOR EXAMINATION BY U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 1 March 1994
Resolved
PROVIDE NECESSARY DOCUMENTATION ON COMPETENT PERSON QUALIFICATION TO MSO NOLA, AND MAKE ALL TANKS AND VOIDS AVAILABLE FOR INTERNAL EXAMINATION BY U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 14 May 1993
Resolved
REPAIR MAIN ENGINE EMERGENCY STOP SWITCHES ON BRIDGE.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
PRINT NAME OR LABEL SPACES ON SOUND POWERED PHONES.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Fire Fighting
Issued 14 May 1993
Resolved
INSTALL HOSE ON FIRE STATION LOCATED PORT SIDE AFT & TEST.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Lifesaving
Issued 14 May 1993
Resolved
REPAIR OR REMOVE 3 EXTRA PFDs.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Engineering
Issued 14 May 1993
Resolved
LABEL REMOTE F/O SHUTOFF VLAVE STATION ON OUTSIDE DOOR.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Engineering
Issued 14 May 1993
Resolved
INSTALL PLUG FOR F/O CONTAINMENT BOX STBD SIDE, FWD END CARGO DECK.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Fire Fighting
Issued 14 May 1993
Resolved
MAKE PERMANENT REPAIRS TO LEAKING GAUGE LINE FOR FIRE/BALLAST PUMP.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Electrical
Issued 14 May 1993
Resolved
PROVIDE LABELS ON ALL CONTROLLERS IN THE ENGINE ROOM SPACE.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Engineering
Issued 14 May 1993
Resolved
INSTALL GUARDS ON EXPANSION TANK SIGHT GLASSES LOCATED IN MACHINERY SPACES.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Engineering
Issued 14 May 1993
Resolved
TEST OVERSPEED TRIPS ON BOTH MAIN DIESEL ENGINES IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Engineering
Issued 14 May 1993
Resolved
TEST ALARMS FOR MAIN DIESEL ENGINES IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Fire Fighting
Issued 14 May 1993
Resolved
MAKE MORE ACCESSIBLE, CO2 EXTINGUISHER LOCATED NEAR FWD BULKHEAD GENERATOR ROOM.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Electrical
Issued 14 May 1993
Resolved
LABEL "WARNING: HIGH VOLTAGE" ON MAIN SWITCHBOARD IN ENGINE ROOM. LOCATED FWD BULKHEAD NEXT TO ER ENTRANCE.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
REPAIR DIMMER SWITCH FOR MAGNETIC COMPASS LIGHT.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
REPAIR/REPLACE INDICATOR LIGHTS ON NAVIGATION LIGHT CONTROL PANEL ON BRIDGE.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
REPAIR LIGHT FOR COMPASS ON BRIDGE.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
REPLACE RESTRICTED IN ABILITY TO MANEUVER DAY SHAPES (BALL DIAMOND BALL).
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Lifesaving
Issued 14 May 1993
Resolved
REPAIR EPIRB & TEST.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Navigation
Issued 14 May 1993
Resolved
PERFORM STEERING GEAR TEST.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Lifesaving
Issued 14 May 1993
Resolved
PROPERLY INSTALL HYDROSTATIC RELEASE ON LIFERAFT.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Accommodation/Occupational Safety
Issued 14 May 1993
Resolved
LABEL STOVE DISCONNECT IN GALLEY.
Condition: Unknown
Due 14 July 1993
Resolved 14 June 1993
Documentation
Issued 6 April 1992
Resolved
MAKE COPIES OF SHIP'S LOG FM 25FEB91 AND SUBMIT TO COGNIZANT [name withheld] IAW 46CFR97.35.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 6 April 1992
Resolved
PROVE PROPER OPERATION OF BILGE PUMP.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Engineering
Issued 6 April 1992
Resolved
DEMONSTRATE PROPER OPERATON OF BOTH MDE'S, OVERSPEED AND SAFETY DEVICES, CONDUCT ENGINE TESTS FM ALL STATIONS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992
Resolved
PROVIDE ONBOARD SIX (6) HAND RED DISTRESS SIGNALS AND SIX (6) HAND ORANGE DISTRESS SIGNALS OR TWELVE (12) HAND COMBINATION FLARE AND SMOKE DISTRESS SIGNALS IAW 46CFR94.90-5(b). PRESENTLY BRAZILIAN FLARES ONBOARD._x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992
Resolved
RESERVICE 8 PERSON ELLIOT LIFERAFT SERIAL# RE8/1024 WITH THE FOLLOWING USCGAPPROVED EQUIPMENT WHEN MADE AVAILABLE BY PENDENT LINE, LIFERAFT SERVICING FACILITY: WATER, PROVISIONS, FIRST AID KIT, FLARES, CEMENT AND SEA SICKNESSPILLS._x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Electrical
Issued 6 April 1992
Resolved
DEMONSTRATE PROPER OPERATION OF STBD SSDG, OVERSPEED AND SAFETY DEVICES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992
Resolved
PROVIDE ONBOARD ONE (1) EPIRB BATTERY IAW 46CFR94.60. VESSEL IS NOT TO OPERATE NOT MORE THAN 20 MILES FM A HARBOR OF SAFE REFUGE. VSSL LIMITED TO COASTWISE SERVICE UNTIL ITEM 6 IS CLEARED._x001C_ _x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Accommodation/Occupational Safety
Issued 25 February 1989
Resolved
INSTALL GALLEY VENT DUCTING CONSTRUCTED OF SHEET METAL FROM VENT FAN TO VERTICAL EXHAUST WITHOUT RUBBER GASKETED FLANGES.
Condition: Unknown
Due 25 February 1989
Resolved 25 February 1989
Navigation
Issued 25 February 1989
Resolved
REPLACE INSTALLED NAVIGATION LIGHTS WITH UL APPROVED LIGHTS.
Condition: Unknown
Due 25 February 1989
Resolved 25 February 1989
Documentation
Issued 25 February 1989
Resolved
PROVIDE AND POST POLLUTION PLACARD.
Condition: Unknown
Due 25 February 1989
Resolved 25 February 1989
Lifesaving
Issued 25 February 1989
Resolved
MARK EMERGENCY EXITS FROM LOWER CREW'S BERTHING AND ENGINE ROOM WITH; EMERGENCY EXIT, KEEP CLEAR.
Condition: Unknown
Due 25 February 1989
Resolved 25 February 1989
Fire Fighting
Issued 22 September 1986
Resolved
CONTACT ABS AND RESOLVE ACTUAL PLACEMENT OF LOADLINE MARKINGS AND CONFIRM CORRECT INFORMATION ON LOADLINE CERTIFICATE UNTIL SUCH TIME AS THIS REQUIREMENT IS CLEARED, LOAD VESSEL IN STRICT COMPLIANCE WITH THE COAST GUARD'S STABILITY LETTER OF 29JUN82.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Documentation
Issued 22 September 1986
Resolved
TEST FUEL OIL TRANSFER HOSE TO 225 PSI IN ACCOREANCE WITH 33 CFR 154.500 AND MAINTAIN RECORDS IN ACCORDANCE WITH 33 CFR 155.820.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Engineering
Issued 22 September 1986
Resolved
HYDROSTATICALLY TEST CO2 FIRE EXTINGUISHER AT STATION #1 IN WHEELHOUSE.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Engineering
Issued 22 September 1986
Resolved
INSTALL OPERABLE PRESSURE GAUGE ON DISCHARGE SIDE OF FRESH WATER PUMP.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Accommodation/Occupational Safety
Issued 22 September 1986
Resolved
RE-LAMP MAIN SWITCHBOARD.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Electrical
Issued 22 September 1986
Resolved
PROVIDE EFFICIENT GROUNDING OF LAL 110 VAC RECEPTACLES.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Electrical
Issued 22 September 1986
Resolved
DESIGNATE PERSON IN CHARGE OF REFUELING OPERATIONS AND PROVIDE OIL TRANSFERPROCEDURES INCLUDING PIPING DIAGRAM IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Fire Fighting
Issued 22 September 1986
Resolved
HARD PIPE FIRE MAIN IN WAY OF FLEXIBLE HOSE CONNECTION ON AFT ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Fire Fighting
Issued 22 September 1986
Resolved
PROVIDE ONE (1) 50 FT UL APPROVED 1 1/2" DIAMETER FIRE HOSE.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Engineering
Issued 22 September 1986
Resolved
MAKE OPERATIONAL HIGH WATER TEMPERATURE ALARM ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Lifesaving
Issued 22 September 1986
Resolved
INSTALL CG APPROVED LIFERAFTS FOR THE PERSONS.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Electrical
Issued 22 September 1986
Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING IN AREA OF LIFERAFTS.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Accommodation/Occupational Safety
Issued 22 September 1986
Resolved
INSTALL STOVE VENT DUCTING METAL LINED WITH A MINUMUM OF 20 GAUGE SHEET METAL.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Electrical
Issued 22 September 1986
Resolved
PERMANENTLY INSTALL DRYER 220 VAC OUTLET.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Engineering
Issued 22 September 1986
Resolved
TEST RELIEF VALVE ON AIR RECEIVER.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Navigation
Issued 22 September 1986
Resolved
PROVIDE EFFICIENT AND PERMANENTLY INSTALLED COMMUNICATIONS BETWEEN WHEELHOUSE AND ENGINE ROOM.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Lifesaving
Issued 22 September 1986
Resolved
PROVIDE CG APPROVED VISUAL DISTRESS SIGNALS IN ACCORDANCE WITH 46 CFR 180. 35.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986