Records from 1982 to 2004. Most recent: inspection, 5 April 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 99
5 April 2004
Construction Oversight · Administrative Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2040870
16 January 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1986794
12 March 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1756480
18 February 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1747009
7 January 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1727193
28 June 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1638485
22 April 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1607882
10 April 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1603341
2 April 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1600070
25 February 2002
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1484852
15 January 2002
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1478511
18 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075883
26 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073187
25 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073151
17 April 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1062555
5 March 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468627
19 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1055468
12 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 79183
14 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819243
18 May 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1049701
10 April 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1048743
6 April 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1048337
29 January 2000
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1399271
12 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805704
29 October 1999
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1048155
17 August 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 89100
1 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26620
27 July 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461996
12 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091608
2 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803972
27 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126024
25 March 1999
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1458618
23 December 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808099
3 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805351
21 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802442
15 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125389
30 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124363
5 February 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364561
3 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122459
19 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 50247
13 August 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118191
23 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140454
12 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778025
17 April 1997
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1442534
8 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098849
27 March 1997
Administrative
Administrative · Commandant (CG-CVC) · Activity 1097468
8 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088632
11 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083646
6 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446292
11 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184792
22 May 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1358824
6 April 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840848
18 July 1994
Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389876
25 February 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164085
13 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454055
21 December 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849723
11 March 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370599
16 February 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 832208
5 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79535
7 December 1992
Damage Survey · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141039
19 August 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251675
14 June 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417460
21 April 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945431
14 April 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263992
27 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949940
13 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263329
29 October 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940192
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900884
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922002
28 February 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218769
14 August 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911617
8 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922894
15 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228286
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921749
21 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214286
27 July 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044608
28 April 1989
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205276
27 March 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1344638
1 December 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205846
21 October 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199435
25 April 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342543
8 April 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338034
23 February 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332027
24 March 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329382
16 November 1986
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1327666
29 September 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006419
27 May 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303862
25 February 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304264
23 December 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 996049
22 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290034
7 March 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 977816
6 February 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1285605
13 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278729
23 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972976
23 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977330
13 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964740
21 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277730
2 March 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966914
19 March 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275255
Construction/Loadline › Hull
Issued 25 February 2002
Resolved
CROP AND RENEW WASTED SECTION OF BOTTOM PLATING ON STARBOARD BOW BACK TO GOOD STEEL. AS ALTERNATIVE, PROVIDE GAUGING REPORT WITH PROPER REPAIR PROPOSAL. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 25 March 2002
Resolved 2 April 2002
Construction/Loadline › Structures
Issued 25 February 2002
Resolved
CROP AND RENEW, BACK TO GOOD STEEL, AFT PART OF HOUSE WHERE DOUBLED. LEGACY COMPONENT DESC: Superstructure
Due 25 April 2002
Resolved 22 April 2002
Engineering
Issued 25 February 2002
Resolved
RENEW MAIN SALT WATER LINE IN STARBOARD SIDE MUD PIT ROOM, WHERE VARIOUS DOUBLERS ARE LOCATED.
Due 25 March 2002
Resolved 2 April 2002
Fire Fighting › Fire Main
Issued 25 February 2002
Resolved
RENEW FIRE MAIN LINE IN PORT STORE ROOM WHERE DOUBLERS ARE LOCATED. LEGACY COMPONENT DESC: Condition
Due 25 March 2002
Resolved 2 April 2002
Construction/Loadline › Hull
Issued 25 February 2002
Resolved
CONDUCT SEILOD, PHASE II.
Due 1 August 2002
Resolved 21 August 2002
Resolution: RECEIVED THIRD PARTY REPORT FOR SEILODD PHASE II COMPLETED ON 19JULY02.
Navigation
Issued 5 March 2001
Resolved
REPAIR STERN NAVIGATIONAL LIGHT.
Condition: Unknown
Due 5 March 2001
Resolved 22 March 2001
Lifesaving
Issued 5 March 2001
Resolved
REPLACE LANYARD ON STARBOARD SIDE MAIN DECK RING BUOYS, SPLICE IN NEW LANYARDS.
Condition: Unknown
Due 5 March 2001
Resolved 22 March 2001
Electrical
Issued 5 March 2001
Resolved
Repair emergency light in Bulk Tank Room.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 5 March 2001
Resolved
MAKE RIG AIR RECEIVER AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 5 April 2001
Resolved 22 March 2001
Construction/Loadline
Issued 5 March 2001
Resolved
Effect permanent repairs to thinned and holed deck plating in way of Mud Pit Room door.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 5 March 2001
Resolved
Eliminate excessive leakage from Number One Fire Pump shaft mechanical seal.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 5 March 2001
Resolved
REPAIR FIRE DAMPNER IN GALLEY OVERHEAD ADJACENT TO AIR CONDITIONING UNIT.
Condition: Unknown
Due 5 March 2001
Resolved 22 March 2001
Construction/Loadline
Issued 5 March 2001
Resolved
On main deck weather tight doors and below deck watertight doors, adjust/repair dogs and wedges as necessary to ensure adequate seals. Fittings are to be chalk tested for attending Marine Inspector.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Lifesaving
Issued 29 January 2000
Resolved
Make proper repairs to flapper switches in way of mud pit room for ventilation failure alarms.
Condition: Unknown
Due 28 February 2000
Resolved 2 February 2000
Fire Fighting
Issued 29 January 2000
Resolved
Make repairs or replace fire door closure, 2nd deck portside to living quarters.
Condition: Unknown
Due 29 January 2000
Resolved 29 January 2000
Construction/Loadline
Issued 29 January 2000
Resolved
Prove proper seal and closure on all Main Deck watertight doors and emergency exit door in way of change room._x001C_
Condition: Unknown
Due 29 January 2000
Resolved 29 January 2000
Electrical
Issued 29 January 2000
Resolved
Provide documentation attesting to the proper setting of the high water temp bulbs in way of the three ship service generators and the emergency generator.
Condition: Unknown
Due 29 January 2000
Resolved 29 January 2000
Construction/Loadline
Issued 27 July 1999
Resolved
MAKE MASTER DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 23 August 1999
Resolved 23 August 1999
Construction/Loadline
Issued 27 July 1999
Resolved
CONDUCT NDE OF LEG TO CAN CONNECTIONS, COMPLETE UNDERWATER SURVEY. PROVIDE A COPY OF DIVERS REPORT AND VIDEO TO THE [name withheld] ALSO PROVIDE A COPY OF ABS SPECIAL SURVEY TO [name withheld].
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 27 July 1999
Resolved
REMOVE DOUBLER FROM UNDERSIDE OF MUD PITS IN VOID #12. CROP AND RENEWED WASTED AREA AS NECEASSARY USING ABS GUIDANCE FOR INSERTS.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 25 March 1999
Resolved
discharge hoses for fixed Halon system for SCR room twisted, Re-fit properly and provide verification of proper fit-up
Condition: Unknown
Due 25 April 1999
Resolved 30 March 1999
Lifesaving
Issued 5 February 1998
Resolved
Have all three breathing air bottles in both lifeboats hydrostatically tested and renew all flex lines from bottle to manifold.
Condition: Unknown
Due 16 February 1998
Resolved 16 February 1998
Lifesaving
Issued 5 February 1998
Resolved
Conduct 1.1 release gear operational test on both lifeboats.
Condition: Unknown
Due 5 February 1998
Resolved 5 February 1998
Fire Fighting
Issued 5 February 1998
Resolved
Install general alarm bell or light in area of port-aft leg on main deck, near paint locker area.
Condition: Unknown
Due 16 February 1998
Resolved 16 February 1998
Electrical
Issued 5 February 1998
Resolved
Conduct test of total rig emergency shutdown and log properly.
Condition: Unknown
Due 16 February 1998
Resolved 16 February 1998
Deck/Cargo
Issued 17 April 1997
Resolved
Prepare all bulk tanks for internal exam at continuation of SIELOD.
Condition: Unknown
Due 17 April 1997
Resolved 21 April 1997
Construction/Loadline
Issued 17 April 1997
Resolved
Complete bottom portion of SEILOD before departing OCMI zone._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1997
Resolved 21 April 1997
Electrical
Issued 17 April 1997
Resolved
Replace starboard and forward leg elevation circuit breakers.
Condition: Unknown
Due 17 April 1997
Resolved 21 April 1997
Navigation
Issued 6 February 1996
Resolved
REMOUNT NAVIGATION LIGHTS AND REPAIR ELECTRICAL CABLE TO PORT NAV. LIGHT.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Documentation
Issued 6 February 1996
Resolved
SUBMIT EMERGENCY EVACUATION PLAN IN ACCORDANCE WITH 33 CFR 146.140 TO [name withheld], LA.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 6 February 1996
Resolved
RENEW BREATHING AIR RELIEF VALVE FOR LIFEBOAT #1.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 6 February 1996
Resolved
PERFORM QUARTERLY LIFEBOAT DAVIT WINCH INSPECTION IN ACCORDANCE WITH 46 CFR109.221.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Electrical
Issued 6 February 1996
Resolved
PROPERLY SECURE THE FOLLOWING ELECTRICAL CABLES: ARMOR CABLE ON AFT SIDE OF DRILL FLOOR; GREEN ARMORED CABLE ON PORT SIDE OF DERRICK; SPEAKER CABLE IN SHAKER HOUSE; 3RD PARTY WIRING ON STARBOARD SIDE OF RIG FLOOR.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 22 May 1995
Resolved
Properly secure or remove dead end wire to SCR space power distribution panel located above "TD Hyd unit/ TD Blower MTR" breakers.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Repair exhaust leaks on both lifeboats.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Provide boat plug for #2 lifeboat.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 22 May 1995
Resolved
Replace damaged fire nozzle at fire station #16.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Engineering
Issued 22 May 1995
Resolved
Adjust overspeed trip to within 15% of rated speed I.A.W. ABS rules for emergency generator.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 22 May 1995
Resolved
Perform hydro test on time delay bottles in fixed fire fighting system.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Documentation
Issued 22 May 1995
Resolved
Provide on board an approved Ship board Oil Pollution Emergency Plan in conformance with MARPLO regulation 26.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 22 May 1995
Resolved
Repair motor room monitor control panel.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 22 May 1995
Resolved
Dead end wires in junction box must be properly secured and junction box coverd at motor room overhead beam in front of watermaker.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Construction/Loadline
Issued 22 May 1995
Resolved
Repair bilge alarm to sack room.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Repair guard to #2 mud mixing pump.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 22 May 1995
Resolved
Install blank to circuit breaker panel in sack room lighting panel ELEC-1.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 22 May 1995
Resolved
Replace fire hose at fire station in sack room.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 22 May 1995
Resolved
Stencil number at fire station in sack room.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Replace relief valve to sanitary tank located by air compressor.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 22 May 1995
Resolved
Install rubber gaskets to nozzles at fire stations #11 and #18.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Engineering
Issued 22 May 1995
Resolved
Repair exhaust guard on left side of emergency generator exhaust pipe.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Insatll protective guard in way of fan belts and pulleys on emergency generator.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
Repair general alarm in motor room.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Construction/Loadline
Issued 18 July 1994
Resolved
MAKE SPUD CANS (LOWER HULL) AVAILABLE FOR INSPECTION PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Unknown
Issued 18 July 1994
Resolved
PROVIDE COPY OF FINAL REPORT OF SPUD CAN INSPECTION AND COMPLETION OF REPAIRS TO ELBOW AT DUMP VALVE HULL PENATRATION IN PRELOAD TANK #28 TO [name withheld], LA
Condition: Unknown
Due 16 September 1994
Resolved 26 September 1994
Construction/Loadline
Issued 18 July 1994
Resolved
MAKE MUD PIT MASTER DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Construction/Loadline
Issued 18 July 1994
Resolved
IN PRELOAD TANK #28: CLEAN INBOARD BULKHEAD BETWEEN VERTICAL WEBS TO BARE STEEL FOR INSPECTION; REPLACE WASTED PORTION OF UPPER LONGITUDINAL ON SAME BULKHEAD; CLEAN/INSPECT DUMP VALVE ELBOW; CLEAN INSPECT WASTED BOTTOM PLATEFROM OUTSIDE OF HULL.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 7 December 1992
Resolved
PROVIDE FINAL MATERIALS LIST TO INCLUDE MILL CERTIFICATES AND PROVIDE ABS SURVEY REPORT TO USCG NEW ORLEANS, LA.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Construction/Loadline
Issued 7 December 1992
Resolved
PROVIDE A COPY OF LEG REPAIR PROPOSAL TO [name withheld], LA. FOR REVIEW AND APPROVAL. PROPOSAL SHALL INCLUDE WELD PROCEDURE AND WELDER QUALIFICATION CERTIFICATES. REPAIRS SHALL BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Construction/Loadline
Issued 7 December 1992
Resolved
MAKE ALL LEG TO CAN CONNECTIONS AND FULL LENGTH OF LEG AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Construction/Loadline
Issued 27 March 1992
Resolved
REPAIR WATERTIGHT PROT MAIN DECK HATCH TO PROVIDE WATERIGHT SEAL.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Electrical
Issued 27 March 1992
Resolved
REPAIR OVERSPEED TRIP ON EMERGENCY GENERATOR TO TRIP NO HIGHER THANB 2070 RPM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Accommodation/Occupational Safety
Issued 27 March 1992
Resolved
PROVIDE HANDRAILS ON FWD AND AGT WALKWAYS UNDER DRILL FLOOR HBY DIVING BOARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Fire Fighting
Issued 13 February 1992
Resolved
REPAIR THE FOLLOWING FIRE DAMPERS: 1.OUTSIDE ROOM 201. 2.NEXT TO THE LIGHT NEXT TO AIR HANDLER #1. 3.HANDLE MISSING ON THE ONE NEXT TO THE EMERGENCY LIGHT IN GALLEY. 4.NEXT TO THE LIGHT LOCATED BY THE AIR HANDLER #2.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Engineering
Issued 13 February 1992
Resolved
CLEAN AND REPAIR THE FLAME SCREENS TO FUEL AND D.O. VENTS.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Electrical
Issued 13 February 1992
Resolved
LABEL CIRCUIT BREAKERS IN ALL CRANES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Fire Fighting
Issued 13 February 1992
Resolved
TEST FIRE STATIONS #20 AND 22.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Electrical
Issued 13 February 1992
Resolved
CLEAN OBSTRUCTION LIGHT LENS.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
INSTALL LIFEBOAT VENT MODIFICATION KIT.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
INSTALL WATER SPRINKLER PUMP TO LIFEBOAT #2.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Electrical
Issued 13 February 1992
Resolved
REPLACE MISSING GUARD OR GLOBE TO THE LIGHT IN THE STARBOARD AFT AND PORT CRANE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
PROVIDE 500 FEET OF 3 INCH. CIRCUMFERENCE MANILA LINE FOR THE LINE THROWINGGUN.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
CALIBRATE OXYGEN/EXPLOSION METER.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
REPAINT EXTERIOR OF BOTH LIFEBOATS.
Condition: Unknown
Due 13 June 1992
Resolved 14 April 1992
Lifesaving
Issued 13 February 1992
Resolved
COMPLETE WORKLIST ISSUED BY WATERCRAFT AND SAFETY CONCEPTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Documentation
Issued 13 February 1992
Resolved
PLACE CONSTRUCTION PORTFOLIO ONBOARD RIG._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Navigation
Issued 13 February 1992
Resolved
REPAIR THE STERN NAVIGATION LIGHT.
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Deck/Cargo
Issued 13 February 1992
Resolved
CLEAN CRANE CONTROL BOXES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1992
Resolved 14 April 1992
Fire Fighting
Issued 21 February 1990
Resolved
INSTALL GENERAL ALARM BELL IN MUD PIT ROOM.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Electrical
Issued 21 February 1990
Resolved
RENEW THE TYPE "SO" CABLE IN THE BACK OF THE DRILLERS CONSOLE GOING INTO THE TORQUE METER.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Fire Fighting
Issued 21 February 1990
Resolved
LABEL THE OPERATIONS VALVES IN THE HALON SYSTEM INCLUDING REMOTE STATIONS SO THAT THEY AGREE WITH THE INSTRUCTION.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Lifesaving
Issued 21 February 1990
Resolved
RESET RELIEF VALVE FOR AIR BOTTLES IN NO. 2 LIFEBOAT.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Fire Fighting
Issued 21 February 1990
Resolved
MAKE PERMENANT REPAIRS TO THE FIREMAIN SYSTEM (5" LINE) IN THE MSD ROOM ABOVE FIRE STATION #11.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Fire Fighting
Issued 21 February 1990
Resolved
REPAIR GENERAL ALARM BELL LOCATED ON DECK AFT OF LIVING QUARTERS STBD SIDE.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Lifesaving
Issued 21 February 1990
Resolved
REPLACE PLEXIGLASS IN COXSWAIN STATION IN NO. 2 LIFEBOAT.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Accommodation/Occupational Safety
Issued 21 February 1990
Resolved
REPLACE GASKETS ON VENTILATION COVERS AS NECESSARY.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Lifesaving
Issued 21 February 1990
Resolved
REPAIR EMERGENCY ESCAPE LADDER, PORT AFT.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Lifesaving
Issued 21 February 1990
Resolved
REMOV MARINE GROWTH ON EMERGENCY EMBARKATION LADDERS IN LATTICE LEGS TO WATER LINE.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Accommodation/Occupational Safety
Issued 21 February 1990
Resolved
MAKE THE AIR RECEIVERS AVAILABLE FOR ENTERNAL EXAM BY US COAST GUARD MARINEINSPECTOR. THIS INCLUDES BULK TANKS.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Deck/Cargo
Issued 21 February 1990
Resolved
CONDUCT RELIEF VALVE POP OFF TEST FOR THE AIR RECEIVER AND BULK TANK VALVESIN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Unknown
Issued 27 July 1989
Resolved
PROVIDE TO MSO PORT ARTHUR A COPY OF GLOBAL DIVERS NDT AND VIDEO REPORT OF SPUD CAN INSPECTION.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989
Resolved
RECONDITION THE LANDINGS AND FACE SEATS TO GATE VALVE IN #8 PRE-LOAD TANK.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989
Resolved
FREE FROZEN CHECK VALVES AND PROVIDE COUNTER WEIGHTS WHERE MISSING IN TANK NUMBERS 2, 8, 9, 15, 16, 22A, 28.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989
Resolved
CLEAN OUT SUCTION BELL SCREENS IN TANK NUMBERS 2, 8, 9, 15, 22A, 28.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Fire Fighting
Issued 27 March 1989
Resolved
REPLACE EXPANSION JOINT ON #2 FIRE PUMP DISCHARGE SIDE. MAKE SURE FIT-UP IS PROPER PRIOR TO REPLACEMENT.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Unknown
Issued 21 October 1988
Resolved
REPLACE MISSING SECTION OF GASKET ON HATCH COVER (AIR HANDLING SYSTEM) PORT SIDE MAIN DECK JUST AFT OF CREW QUARTERS.
Condition: Unknown
Due 21 October 1988
Resolved 21 October 1988
Construction/Loadline
Issued 23 February 1988
Resolved
MAKE PROPER ADJUSTMENTS TO THE WATERTIGHT DOORS LEADING FROM THE CHANGE ROOM, THE CENTER MAIN DECK CORRIDOR, AND THE HOSPITAL ROOM.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Lifesaving
Issued 23 February 1988
Resolved
MAKE PROPER REPAIRS TO THE #1 LIFEBOAT WINDOW (BOMAR HATCH).
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Unknown
Issued 23 February 1988
Resolved
MAKE THE DRILL FLOOR AIR RECEIVER AVAILABLE FOR INTERNAL EXAMINATION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Unknown
Issued 23 February 1988
Resolved
MAKE THE DRILL FLOOR AIR RECEIVER AND ALL FOUR (4) DRY BULK TANK RELIEF VALVES AVAILABLE FOR TESTING BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Electrical
Issued 23 February 1988
Resolved
MAKE THE EMERGENCY GENERATOR OVERSPEED TRIP, LOW LUBE OIL PRESSURE ALARM AND AUTOMATIC BUS TRANSFER AVAILABLE FOR TESTING BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Electrical
Issued 23 February 1988
Resolved
MAKE THE REMOTE EMERGENCY ENGINE SHUTDOWN FROM THE TOOLPUSHER'S OFFICE AVAILABLE FOR TESTING BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Electrical
Issued 23 February 1988
Resolved
REPAIR AND MAKE THE INTERIOR SPACE VENTILATION SHUTDOWN AVAILABLE FOR TESTING BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Documentation
Issued 23 February 1988
Resolved
REVISE HAZARDOUS LOCATION PLAN TO INCLUDE THE DESANDER AND RECOVERY UNITS LOCATED ON DECK.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Unknown
Issued 25 February 1986
Resolved
PROVIDE DOGGING WRENCHES FOR WATERTIGHT DOORS WHERE NEEDED. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
FLUSH OUT ALL FIRE STATIONS BELOW DECKS TO REMOVE MUD FROM THE LINES. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PLACE BLANK IN LIGHTING PANEL LOCATED IN HALLIBURTON ROOM. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE FUEL VENT OUTSIDE OF EMERGENCY GENERATOR ROOM FOR FUEL TANK AND PLUG ALL FUEL VENTS INSIDE THE SPACE. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86).
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
INSTALL PROTECTIVE GUARD OVER EMERGENCY GENERATOR EXHAUST. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE VENT SCREEN AND GAS TIGHT COVER FOR FUEL TANK ON TOP OF QUARTERS/ORGAS FREE. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
PROVIDE ON BOARD A FIRST AID KIT MEETING THE REQUIREMENTS OF 46CFR108.707 REF. 30CFR77.1707(MSHA). COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Deck/Cargo
Issued 25 February 1986
Resolved
PROVE SATISFACTORY OPERATION OF RELIEF VALVES ON THE DRILL FLOOR AIR RECEIVERS AND ON THE (2) BARITE BULK TANKS. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROPERLY SUPPORT THE ELECTRICAL CABLE TO THE LOGGING UNIT ON THE MAIN DECK AND REPLACE CABLE DUE TO DAMAGE AND PROPERLY RUN CABLE THROUGH THE DECK SUFFING TUBE. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
PROVIDE AIR BOTTLE FOR FIREMAN'S OUTFIT LOCATED IN THE PILOTHOUSE WITH THE PROPER PRESSURE. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
REPLACE THE MISSING HANDLES ON THE VENT DUCT REMOTE CLOSURES 0 LOCATED IN THE PORT SIDE OF THE THIRD DECK PASSAGEWAY. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Deck/Cargo
Issued 25 February 1986
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION AIR RECEIVER ON DRILL FLOOR AND (2) BARITE BULK TANKS. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
PROVIDE ON BOARD ONE ADDITIONAL APPROVED PARACHUTE FLARE FOR THE VESSELS SIGNALING EQUIPMENT TOTAL OF 12 REQUIRED. (COMPLIANCE DATE IS 25MAR86).
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
REFILL BOTTOM AIR BOTTLE IN THE PORT LIFEBOAT AND REPAIR OR REPLACE PRESSURE GAGE ON THE AIR SYSTEM. COMPLIANCE DATE IS 25MAR86
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
REPAIR OR REPLACE MISSING OR DAMAGED DOOR GASKETS AND REPAIR LEAK IN THE PVC SPRINKLER PIPING FORWARD OVERHEAD IN THE PORT LIFEBOAT. (COMPLIANCE DATE IS 25MAR86).
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
REFILL BOTTOM AND STARBOARD AIR BOTTLES IN STARBOARD LIFEBOAT AND REPAIR ORREPLACE PRESSURE GAUGE ON THE AIR SYSTEM. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 25 February 1986
Resolved
RENEW DOOR GASKETS IN THE STARBOARD LIFEBOAT. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
PROVIDE ALL PURPOSE NOZZEL FOR FIRE STATION ON UPPER PIPE RACK PORT SIDE TOREPLACE THE NOZZEL TIP THAT IS MISSING. (COMPLIANCE DATE IS 03MAR86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE FIRE EXTINGUISHER FOR FORKLIFT. (COMPLIANCE DATE IS 25MAR86) (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
ADJUST WATERTIGHT DOOR ON 3RD LEVEL GOING TO STARBOARD BOAT. (CLEARED 25MAR86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE REMOTE VENTILATION SHUTOFFS AND FUEL OIL SHUTOFFS. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
ADJUST WATERTIGHT DOORS IN MUD PIT ROOM TO CLOSE PROPERLY. COMPLIANCE DATEIS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
ADJUST DOGS ON HATCH NO. 30 TO ENSURE PROPER CLOSURE. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86).
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Accommodation/Occupational Safety
Issued 25 February 1986
Resolved
INSTALL RELIEF VALVES ON HOT WATER HEATER LESS THAN 100 PSIG. OR OPEN FOR INTERNAL INSPECTION AND BENCH TEST RELIEF VALVES. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE ON BOARD TWO OPERABLE, APPROVED 02/LFL METERS. COMPLIANCE DATE IS 25MAR86.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
REPAIR/REPLACE BROKEN LIFELINE ON THE PORT LIFEBOAT AND REPAIR OR REPLACE DETERIATED LIFELINE ON THE STARBOARD LIFEBOAT. COMPLIANCE DATE IS 25MAR86.(CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
MAKE OPERABLE THE BOOM ANGLE INDICATOR ON THE PORT CRANE. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE DEAD-MAN NOZZEL FOR THE REFUELING HOSE FOR THE LOGGING UNIT LOCATEDON THE PILOTHOUSE DECK. COMPLIANCE DATE IS 25MAR86. (CLEARED 25FEB86)
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Lifesaving
Issued 7 March 1985
Resolved
PROVIDE OARS FOR EACH SURVIVAL CAPSULE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Lifesaving
Issued 7 March 1985
Resolved
RENEW OUTDATED RING BOUY SMOKE SIGNALS.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Lifesaving
Issued 7 March 1985
Resolved
RENEW OUTDATED PYROTECHNICS IN BOTH SURVIVAL CAPSULES: PORT CAPSULE- SMOKE SIGNALS, HAND HELD FLARES (PARACHUTE FLARES DUE THE END OR MAR 1985 ALSO) STBD CAPSULE- HAND HELD FLARES, SMOKE SIGNALS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Accommodation/Occupational Safety
Issued 7 March 1985
Resolved
PROVIDE A SUITABLE GUARD OR PERSONEL PROTECTION DEVICE OVER CLOTHES DRYER DRIVE CHAIN AND BELT.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Unknown
Issued 23 February 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V PENROD 88, O.N. 645637.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Accommodation/Occupational Safety
Issued 23 February 1984
Resolved
MAKE THE BULK TANKS AND ASSOCIATED RELIEF VALVES AVAILABLE FOR INSPECTION. THIS IS TO BE COMPLETED NO LATER THAN 15JUN84 TO THE SATISFACTION OF
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Fire Fighting
Issued 23 February 1984
Resolved
PROVIDE FOUR (4) FOOT APPLICATORS IN THE SACK ROOM AND HALIBURTON ROOM FIRESUIT STATIONS THAT SERVE THE MAIN MACHINERY SPACE. 46 CFR 162.027
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Navigation
Issued 23 February 1984
Resolved
PROVIDE AN APPROVED STERN ANCHOR LIGHT FIXTURE. COLREGS
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Accommodation/Occupational Safety
Issued 23 February 1984
Resolved
(CONT. FROM 4) THE COGNIZANT OFFICER IN CHARGE OF MARINE ISPECTION.
Condition: Unknown
Due 23 March 1984
Resolved 11 February 2002
Unknown
Issued 23 February 1984
Resolved
MAKE AVAILABLE AND OPEN FOR INSPECTION THE MUDPIT DUMP VALVE. 46 CFR 61.20-5
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 21 March 1983
Resolved
PROVIDE EYS SEALS IN THE SHALE SHAKER AREA AS FOLLOWS: (A) TO THE GENERAL ALARM BELL (B) TO EACH OF TWO SHAKER MOTORS (C) TO MOTOR CONTROLLER FOR
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
MAKE GAS DETECTOR ON DRILL FLOOR SUITABLE FOR HAZARDOUS LOCATION. (46 CFR 108.175)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Fire Fighting
Issued 21 March 1983
Resolved
HAVE FIXED FIRE EXTINGUISHERS SERVICED AND PROVIDE DOCUMENTATION. ( 46 CFR 107.235)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Fire Fighting
Issued 21 March 1983
Resolved
PROVIDE COMPLETE DOCUMENTATION OF SERVICING OF PORTABLE EXTINGUISHERS. RECORD MUST INCLUDE IDENTIFICATION OF EACH EXTINGUISHER AND NAME OF PERSON
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Unknown
Issued 21 March 1983
Resolved
(REQ. E5 CONTINUED) COMPLETING SERVICING. (46 CFR 109.435)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
TEST LOW LUBE OIL ALARM ON NUMBER 1, NUMBER 2 AND NUMBER 3 GENERATORS.
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
PROVIDE ELECTRIC PANEL BLANKS IN PANEL NO. EL-3 AND LC-7 ON 3RD FLOOR OF QUARTERS. (46 CFR 111.55-1C)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Accommodation/Occupational Safety
Issued 21 March 1983
Resolved
REPAIR AND TEST OPERATION OF MACHINERY SPACE VENTILATION SHUT DOWN. (46 CFR 11.80-10)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
PROVIDE AND LABEL REMOTE SHUT DOWN FOR FUEL OIL TRANSFER PUMPS AND FUEL OILPURIFIER. (46 CFR 111.80-13)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Unknown
Issued 21 March 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 88, DN645637.
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Documentation
Issued 21 March 1983
Resolved
PROVIDE PERMANENT LOADLINE CERTIFICATE ON BOARD THE VESSEL.
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Documentation
Issued 21 March 1983
Resolved
PROVIDE PERMANENT STABILITY LETTER ON BOARD THE RIG. (46 CFR 107.305)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Lifesaving
Issued 21 March 1983
Resolved
PROVIDE TWO ADDITIONAL PARACHUTE FLARES. (46 CFR 108.521)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Lifesaving
Issued 21 March 1983
Resolved
PROVIDE APPROVED PERSONAL MARKER LIGHTS FOR ALL LIFE JACKETS. (46 CFR 108. 514)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Lifesaving
Issued 21 March 1983
Resolved
PROVIDE THE FOLLOWING ITEMS FOR PORT LIFEBOAT: TWO SIGNAL MIRRORS ONE (1) PARACHUTE FLARE. (46 CFR 108.503)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Lifesaving
Issued 21 March 1983
Resolved
PROVIDE THE FOLLOWING ITEMS FOR STARBOARD LIFEBOAT: TWELVE (12) PARACHUTE FLARES AND ONE (1) JACK-KNIFE. (46 CFR 108.503)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Navigation
Issued 21 March 1983
Resolved
PROVIDE LIGHTS AND DAYS SHAPES AS REQUIRED BY 72 - COLREGS.
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
INSTALL NON CORROSIVE LINING IN BATTERY BOX (OBSTRUCTION LIGHTS). (46 CFR 111.15-15
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
PROVIDE BATTERY BOX WITH NON CORROSIVE LINING FOR EMERGENCY GENERATOR STARTBATTERIES. (46 CFR 111.15-15)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
TEST OVERSPEED TRIP, HIGH JACKET WATER TEMP. ALARM, AND LOW LUBE OIL ALARM ON EMERGENCY GENERATOR. (46 CFR 112.50-1)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION TWO NORTON "MANAGEMENT WHILE DRILLING"INSTRUMENTS LOCATED IN DOG HOUSE ON DRILL FLOOR. (46 CFR 108.175)
Condition: Unknown
Due 21 April 1983
Resolved 11 February 2002
Unknown
Issued 21 March 1983
Resolved
(REQ. E10 CONTINUED) DESILTER.
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
PROVIDE EYS SEAL TO MUD PIT LEVEL INDICATOR FOR PIT NO. 1, NO. 2 AND NO. 3.(46 CFR 108.175)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983
Electrical
Issued 21 March 1983
Resolved
REMOVE (OR MAKE SUITABLE FOR HAZARDOUS LOCATION) NON-EXPLOSION PROOF HORN AND RADIO LOCATED IN DOG HOUSE ON DRILL FLOOR. (46 CFR 108.175)
Condition: Unknown
Due 21 March 1983
Resolved 21 March 1983