← All vessels
JADE MICHAEL
JADE MICHAEL is a 1981 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1981, most recently in December 2020, along with 58 deficiencies and 1 casualty investigation in 2001.
Records from 1981 to 2020. Most recent: inspection, 11 December 2020.
- Built
- 1981
- Last inspected
- 11 December 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 58 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2001
Identity
643653
WDB7505
53576
Flag
UNITED STATES
366943230 (licence lapsed)
Maury page id
psix-53576
Inspections, by type
…with no type recorded16
Years with a record
31 calendar years (1981–2020)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
146 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
43 - Convention (Subpart B), Net Ton
146 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
43 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDB7505MMSI 366943230 · cancelled · compulsorily equipped · granted 12 March 2014, cancelled 7 December 2015
WRA5301MMSI not assigned · expired · voluntarily equipped · granted 23 October 1996, cancelled 23 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110290
18 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817668
21 December 2011
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4211560
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200247
13 July 2011
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4079982
20 December 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3912449
21 October 2010
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3874780
13 October 2010
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3869498
20 July 2009
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3576186
23 March 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2607938
1 December 2005
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2543635
28 April 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2345123
30 March 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2318024
1 April 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2035423
1 December 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1956891
7 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1756788
11 January 2002
COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489668
23 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49907
22 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79892
20 October 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423461
22 June 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393456
26 October 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442899
14 December 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807437
1 December 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433423
21 May 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375396
14 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421417
22 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121976
11 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092351
20 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099651
6 February 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 145709
25 October 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367958
30 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 17227
22 May 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360509
4 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360368
18 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 79500
5 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409219
19 May 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398070
20 January 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457145
14 July 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64139
10 February 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455040
12 May 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471787
8 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120909
17 February 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944914
16 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 75884
31 May 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242028
26 July 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236632
24 August 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043043
2 September 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043421
12 April 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1194578
7 October 1987
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1003056
24 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318935
12 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322935
8 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319302
16 October 1986
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015262
3 January 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1298843
5 November 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301696
7 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980803
15 November 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274757
25 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971409
19 November 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963900
18 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279766
Deficiency record · 58
Communications › Radio Communications › EPIRB
Issued 18 March 2014
Resolved
Vessel needs to replace EPIRB battery and prove operation of device IAW 46 CFR 180.64. Limited route to less than 3NM.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2014
Resolved
Vessel needs to provide black matte backing for running lights IAW NAVRULES Annex I.
Personnel › Training › Fire Fighting Basic
Issued 18 March 2014
Resolved
Vessel needs to provide, post, and deliver passenger safety orientation brief IAW 46 CFR 185.506.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 18 March 2014
Resolved
Vessel needs to provide EPA VGP NOI.
Communications › Public Address System › Announcing Station
Issued 21 December 2011
Resolved
Vessel PA system not required due to old T sub-chapter regulations, however, vsl has passenger seating and crew berthing located below the main deck with no clear communication from the bridge. Vsl shall demonstrate PA system on emergency power.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 21 December 2011
Resolved
Vessel FCC Bridge-to-Bridge certificate expired 27MAR2011. Vessel shall obtain new current certificate.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 21 December 2011
Resolved
Vessel FCC Safety Certificate expired on 27MAR2011. Vessel shall obtain new current certificate.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 21 December 2011
Resolved
Vessel missing EPA Vessel General Permit. Vsl not required to submit NOI (Notice of Intent). Vessel shall provide proof of certificate.
Operations/Management › Drills/Instruction › Fire
Issued 21 December 2011
Resolved
Fire Drill conducted on main deck. Crew communication poor; Vsl Master left Bridge to assist crew on deck, second officer talking on cell phone and Vsl Master smoking during Fire Drill. Advised Vsl Rep. & Vsl Master that drill was not acceptable.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 December 2011
Resolved
Vessel conducted MOB Drill. Crew communication improved, but crew unsure of exact duties to perform during drill. Crew responded with safety harness, hand-held radio and boarding ladder. No life jackets worn and no life ring deployed. Advised Vsl Rep & Vsl Master that drill was not acceptable.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 December 2011
Resolved
Vessel conducted Abandon Ship Drill. Crew communication good. Crew responded with life jackets, hand-held radio, and hand-held flares. Crew failed to retrieve EPIRB. Advised Vsl Rep & Vsl Master that drill was not acceptable.
Electrical › Electric Generation Source (service) › Panelboard
Issued 20 December 2010
Resolved
Provide missing blanks in Power Panel on the bridge.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 20 December 2010
Resolved
Renew 12 life jacket lights.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 20 December 2010
Resolved
Mate nor Master held proper FCC documentation at time of inspection. A proper FCC radiotelephone operator permit shall be provided.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 20 December 2010
Resolved
Provide STBD generator exhaust lagging to flange.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 October 2010
Resolved
Install new stern nav light due to not operating prior to operating at night.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 October 2010
Resolved
Provide drug and alcohol testing equipment.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 October 2010
Resolved
Sewage discharge valve found in open position.
Lifesaving › Hand Flares › Not on Board
Issued 20 July 2009
Resolved
provide 2 Distress Flares
Communications › Radio Communications › Emergency Source of Power
Issued 20 July 2009
Resolved
Demonstrate proper operation of single side band on emergency power.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 July 2009
Resolved
Provide light on compass for operating at night.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 20 July 2009
Resolved
Demonstrate proper operation of emergency fuel transfer pump shut down prior to operation of pump.
Documentation › Certificates/Documents › FCC SSL
Issued 23 March 2006
Resolved
Provide a FCC Safety Certificate.
Lifesaving › Lifefloat › Painter
Issued 23 March 2006
Resolved
Provide a painter for each lifefloat. Install so each lifefloat can be deployed without disturbing the remaining lifefloats.
Lifesaving › Lifebuoys › Immediately Available
Issued 23 March 2006
Resolved
Stow lifebuoys so the lifeline is not tied in a knot.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 23 March 2006
Resolved
Provide Radio Operator permit for licensed mate. Licensed mate is registered for course during the week of 27Mar-31Mar.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 23 March 2006
Resolved
Provide (2) 20 lb Dry Chem portable extinguishers prior to carrying MPTs.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 March 2006
Resolved
Due to KAPOK lifejackets that leaked, the vessel only had 49 serviceable lifejackets onboard. Vessel was instructed not to carry the full complement of persons until the proper amount of lifejackets are onboard.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 23 March 2006
Resolved
At next Dry dock, ensure draft marks are painted a contrasting color.
Fire Fighting › Portable Foam Applicators › General
Issued 30 March 2005
Resolved
VESSEL IS NOT TO TRANSPORT MARINE PORTABLE TANKS CONTAINING FLAMMABLE OR COMBUSTIBLE CARGOES UNTIL REQUIRED ADDITIONAL FIRE FIGHTING EQUIPMENT IS ON BOARD.
Electrical › Lighting (emergency)
Issued 1 April 2004
Resolved
Install emergency lighting to illuminate the area near emergency escape. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Lighting (emergency)
Issued 1 April 2004
Resolved
Replace bulb and battery for battle lantern in stbd side fwd near e/r emergency escape. LEGACY COMPONENT DESC: Battery Operated Lantern
Accommodation/Occupational Safety › Occupational Safety
Issued 1 April 2004
Resolved
Install latch on oven door. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Lifesaving › Buoyant Apparatus
Issued 1 April 2004
Resolved
Two unservicable life floats that must be taken off the vessel LEGACY COMPONENT DESC: Lifefloats
Lifesaving › Lifejacket/PFD (Type III)
Issued 1 April 2004
Resolved
Replace expired pml lights. LEGACY COMPONENT DESC: Lights
Documentation › Certificates/Documents › FCC SSL
Issued 1 April 2004
Resolved
Missing Cert
Documentation › Certificates/Documents
Issued 1 April 2004
Resolved
Provide Original LEGACY COMPONENT DESC: FCC SSL
Construction/Loadline › Hull
Issued 1 December 2003
Resolved
Pad weld pits in bottom plate in way of propellers. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 1 December 2003
Resolved
Gouge and reweld misc cracked welds. LEGACY COMPONENT DESC: Weld
Lifesaving
Issued 1 December 1998
Resolved
AS PER 46 CFR 180.210 (a) PROVIDE A RESCUE BOAT OR OTHER ARRANGEMENT AND EQUIPMENT TO BE ABLE TO RECOVER A HELPLESS PERSON FROM THE WATER. COMPLETE ABOVE AND DEMONSTRATE BY ACTUAL DRILL TO ATTENDING MARINE INSPECTOR.
Electrical
Issued 14 November 1997
Resolved
REPAIR LOOSE ELECTRICAL OUTLET IN THE GALLEY.
Construction/Loadline
Issued 14 November 1997
Resolved
WATERTIGHT DOOR LEADING TO GALLEY WILL NOT SEAL, MAKE APPROPRIATE ADJUSTMENTS FOR EFFECTIVE SEAL.
Electrical
Issued 14 November 1997
Resolved
REPLACE COVER TO J-BOX ON PORT SIDE GENSET.
Engineering
Issued 14 November 1997
Resolved
REPLACE BOTH RELIEF VALVES FOR #1 & #2 PRESSURE VESSELS._x001C_
Lifesaving
Issued 14 November 1997
Resolved
REWIRE GALLEY FREEZER SO ELEC CORD IS OUT OF PERSONNEL WALKWAY.
Lifesaving
Issued 14 November 1997
Resolved
PROVIDE APPROPRIATE SIZE WEAK LINKS FOR LIFE FLOATS._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 14 November 1997
Resolved
STENCIL VSLS NAME ON FIRE AX.
Lifesaving
Issued 14 November 1997
Resolved
PFD MISSING LIGHT & VSL NAME.
Electrical
Issued 14 November 1997
Resolved
PROVIDE LEGEND FOR CIRCUIT BREAKER PANELS IN THE E/R & ON THE BRIDGE.
Lifesaving
Issued 14 November 1997
Resolved
REPLACE DEFECTIVE BATTERY IN LIFE RING WATER LIGHT.
Engineering
Issued 14 November 1997
Resolved
PROVIDE PROPER FLAME SCREENS FOR BOTH FUEL VENTS.
Engineering
Issued 14 November 1997
Resolved
REPLACE TORN AIR START HOSES ON #1 & #3 MDE'S.
Electrical
Issued 14 November 1997
Resolved
REPLACE BAD BATTERY IN E/R BATTLE LANTERN.
Construction/Loadline
Issued 14 November 1997
Resolved
PROVIDE KEEPER CHAINS ON ALL WATER TIGHT HATCHES.
Construction/Loadline
Issued 14 November 1997
Resolved
REPAIR CRACK ON E/R HATCH COMBING, STBD SIDE.
Construction/Loadline
Issued 14 November 1997
Resolved
MAKE REPAIRS TO CRACKED FRAME, PORT SIDE HULL IN GENERATOR SPACE.
Engineering
Issued 14 November 1997
Resolved
REPLACE WORN OIL HOSES ON OIL PUMP & REBOLT THE UNIT TO THE DECK.
Documentation
Issued 16 October 1986
Resolved
OBTAIN CORRECTED STABILITY LETTER SHOWING CORRECT WATERTIGHT DOOR LOCATIONSBY FRAME NUMBER. THERE APPEARS TO BE NO WTD AT FRAME 22 (WOODEN) AND THEREIS A WATERTIGHT DOOR IN THE AREA OF FRAME IS BETWEEN THE GALLAY & CREWS QUARTER PRESENT LTR SHOWS FR 22-23&31.
Casualty record · 1
22 February 2001Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 79892
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
C V III (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.