PROWLER is a 1982 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in January 2020, along with 15 deficiencies and 2 operational controls.

Records from 2016 to 2020. Most recent: operational control imposed, 14 January 2020.

Built
1982
Last inspected
14 January 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 January 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAR6755
Flag
UNITED STATES
Maury page id
psix-53586

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

7 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

14 January 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6889444
14 March 2019 Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6642465
23 January 2018 Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6343201
11 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6336466
18 January 2017 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6072113
13 April 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5858440
22 February 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5819988

Deficiency record · 15

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 January 2020 Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level in the spaces listed in this part. Crew could not demonstrate operation of high water alarms. Demonstrate proper operation of high water alarms to the satisfaction of attending marine inspector. 46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2020
Resolved 5 February 2020
Resolution: DEFICIENCY NOT CORRECTED, BUT CLOSED OUT DUE TO "SURRENDERED" COI STATUS.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 January 2020 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test deemed reasonable to determine the vessel and its equipment are suitable for the service in which they are to be employed. Man overboard drill was unable to be conducted due to other inoperable vital systems onboard. Complete man overboard to the satisfaction of attending marine inspector. 46 CFR 176.840
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2020
Resolved 5 February 2020
Resolution: DEFICIENCY NOT CORRECTED, BUT CLOSED OUT DUE TO "SURRENDERED" COI STATUS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Multiple electrical wires located under the bridge console were not terminated. Mitigate hazard with proper termination. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 5 February 2020
Resolution: DEFICIENCY NOT CORRECTED, BUT CLOSED OUT DUE TO "SURRENDERED" COI STATUS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of piping systems. Port exhaust pipe is weeping at a weld seam. Affect proper repairs to the satisfaction of attending marine inspector by next credit drydock. 46 CFR 176.804(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2020
Resolved 5 February 2020
Resolution: DEFICIENCY NOT CORRECTED, BUT CLOSED OUT DUE TO "SURRENDERED" COI STATUS.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 January 2020 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Two areas noted in engine room where bottom plate is showing signs of corrosion. Remove deck plate throughout engine room for a complete inspection and take proper mitigation steps if appropriate by next credit drydock. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2020
Resolved 5 February 2020
Resolution: DEFICIENCY NOT CORRECTED, BUT CLOSED OUT DUE TO "SURRENDERED" COI STATUS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2019 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Vessel unable to operate bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2019
Resolved 21 March 2019
Resolution: Observed sat operational test of bilge pump draining water from forepeak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
Steering systems. Show satisfactory test of steering system. Port and Stbd steering ram and tiller post connection shows excessive movement at tiller bolts.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2019
Resolved 21 March 2019
Resolution: Observed sat operational test of steering system with no loose hardware.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2019 Resolved
Bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Fuel found in lazarette bilge.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2019
Resolved 21 March 2019
Resolution: Source of fuel leak was found to be loose packing gland on fuel cut off valve stem. Packing gland has been tightened with no further leak observed. Operational test of cut off valve was sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure including all accessible parts of the interior of the hull. Unable to visually inspect ER bilge due to standing water and debris.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2019
Resolved 21 March 2019
Resolution: Bilge has been cleaned. No noted deficiencies during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 March 2019 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a vessel that operates only on protected waters. Gasket on ER hatch inadequate to maintain weather tight boundary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 21 March 2019
Resolution: Gasket has been renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2019 Resolved
Engine exhaust pipe installations. Design of all exhaust systems must ensure minimum risk of injury to personnel. Deep pit observed in port exhaust near forward end cap.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 21 March 2019
Resolution: Noted weld repair on port exhaust pipe.
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2018 Resolved
Areas of pitting along the centerline of the vessel starting below the passenger cabin going all the way forward. Identified 06 dime sized pits that appear excessively deep. Vessel to provide plate thickness for hull and pit depth to determine amount of wastage. 46 CFR 177.10-1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: Vessel removed significant amount of hull to remove pitting.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 January 2018 Resolved
Large flexible hose on port engine exhaust is leaking and corroding the aluminum below. Remove flex hose and identify source of leak. 46 CFR 182.15-20
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 15 March 2018
Resolution: Vessel rep provided photo documentation for replaced flexible hose.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 January 2018 Resolved
Seawater cooling line leading to port engine exhaust had flexible hose with a small leak due to hose wastage. Replace hose. 46 CFR 182.15-20
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 11 January 2018
Resolution: Crew replaced flexible hose.
Engineering › Steering Gear System › Rudder
Issued 11 January 2018 Resolved
Connection for port side tiller arm on the rudder found loose. 46 CFR 182.30-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 11 January 2018
Resolution: Crew tightened connection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.