Records from 1982 to 1990. Most recent: inspection, 8 August 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
8 August 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1218283
3 August 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1213027
17 August 1989
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 902316
8 February 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 898917
11 October 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 892207
5 August 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1342657
9 March 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1028085
27 August 1987
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1337712
9 April 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021502
29 August 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 964804
22 April 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307844
6 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 995159
12 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974264
6 December 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278839
3 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272281
Accommodation/Occupational Safety
Issued 5 August 1988
Resolved
DEMONSTRATE PROPER OPERATION OF MSD.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Documentation
Issued 5 August 1988
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Lifesaving
Issued 5 August 1988
Resolved
INSTALL BUOYANT PENDANTS EVERY 18 INCHES ON BUOYANT APPARATUS AND DELETE OLD VESSEL NAME.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Electrical
Issued 5 August 1988
Resolved
REPLACE SPIN-TYPE CONNECTORS ON TACHOMETER WIRING, STARBOARD ENGINE, WITH PERMANENT CONNECTORS OR SPLICES.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Navigation
Issued 5 August 1988
Resolved
INSTALL DOUBLE NUTS OR COTTER PINS ON MAIN STEERING LINKAGE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 5 August 1988
Resolved
DOUBLE-CLAMP EXHAUST COOLING WATER HOSES.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 5 August 1988
Resolved
PERMANENTLY REPAIR EXHAUST LEAK STARBOARD ENGINE AND INSTALL PROPER INSULATING BLANKETS.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 5 August 1988
Resolved
RE-NEW SHORT, S-SHAPED COOLING WATER PIPE ON PORT ENGINE, PORT SIDE, EXHAUST MANIFOLD.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Electrical
Issued 5 August 1988
Resolved
REMOVE OR RE-NEW UNUSED WIRE ON INDEPENDENT GENERATOR.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Electrical
Issued 5 August 1988
Resolved
DEMONSTRATE PROPER OPERATION OF INDEPENDENT GENERATOR OR REMOVE SAME.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 5 August 1988
Resolved
RE-NEW LEAKING FUEL LINE PORT ENGINE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Electrical
Issued 5 August 1988
Resolved
REMOVE OR PROPERLY CONNECT ELECTRICAL BILGE PUMP WIRING TO BATTERY.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988