MAURY USCG vessel records Sign in
← All vessels

PHYLLIS K

PHYLLIS K is a 1982 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1982, most recently in November 2023, along with 21 deficiencies.

Records from 1982 to 2023. Most recent: inspection, 28 November 2023.

Built
1982
Last inspected
28 November 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG 3799
Flag
UNITED STATES
367529760
Maury page id
psix-53609

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1982–2023)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUXS BAY CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portRIVIERA, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG3799MMSI 367529760 · active · voluntarily equipped · granted 24 March 2022, expires 9 May 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

28 November 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7814319
23 May 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7440714
25 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373925
25 January 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7386042
20 July 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7262442
3 November 2020 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7088444
23 September 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6819217
1 May 2019 Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6674950
19 October 2018 Annual Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6564284
29 December 2017 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6325093
7 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6119722
20 September 2016 DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5993647
21 March 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5838078
4 November 2015 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5743080
13 October 2015 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5741114
12 January 2012 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4263009
8 September 2011 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4139144
7 August 2011 Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4107728
29 September 2010 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3859647
7 July 2009 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3556168
27 October 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3352422
21 October 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3342270
1 June 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2948514
19 March 2007 Simplified Stability Test
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2891250
4 October 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2793320
7 June 2006 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 2673569
30 August 2005 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2508968
18 October 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2220739
12 November 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1946208
19 September 2003 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1912824
21 October 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1693372
10 October 2001 COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1426674
2 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308802
2 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965118

Deficiency record · 21

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 January 2022 Resolved
A vessel must undergo a Certificate of Inspection (COI) renewal exam prior to its COI expiration. Vessel's COI expired September 20, 2021. Vessel must complete a COI inspection prior to the carriage of passengers to the satisfaction of the attending Marine Inspector
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
Resolution: Vessel completed COI inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 January 2022 Resolved
A vessel must undergo a COI renewal exam prior to its COI expiration. Vessels COI expired Sept 20, 2021. Vessel must complete a COI inspection prior to the carriage of passengers to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Satisfactory COI inspection was completed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 July 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not received a drydock exam in over 2 years. Vessel must receive credit drydock examination prior to departure from pier. 46 CFR 176.600 (c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2021
Resolved 25 January 2022
Resolution: Vessel completed satisfactory dry dock exam
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 October 2018 Resolved
Marine Inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory. Marine Inspector observed leak during steering gear test. Vessel shall not carry passengers prior to fixing issue to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 24 October 2018
Resolution: Steering gear was deemed satisfactory during operational test.
Construction/Loadline › Hull › Hull Plating
Issued 2 May 2017 Resolved
Crop and renew to good metal both port and stbd areas aft E/R. Gouge and weld broked weld in crew void port area and laz stern to ovhd broken weld.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 25 May 2017
Resolution: All welds were inspected and Hull inserts were hydrostatically tested. All Tests and welds SAT.
Navigation › Piloting/Steering › Marine Charts
Issued 13 October 2015 Resolved
Charts not up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 4 November 2015
Resolution: Revisted vessel and ensured up-to-date charts.
Lifesaving › Liferaft Equipment › Rescue Quoit
Issued 13 October 2015 Resolved
Rescue platform safety harness is missing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 4 November 2015
Resolution: Revisted vessel and varified safety harness for MOB drills.
Engineering › Freshwater System (jacketwater cooling) › Containment
Issued 13 October 2015 Resolved
Cap missing on jacket water day tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 4 November 2015
Resolution: Revisited vessel and insured installation of cap on jacket water day tank.
Construction/Loadline › Structures › Door
Issued 21 October 2008 Resolved
Replace gasket on port side door bridge door.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 27 October 2008
Resolution: Satisfactorily replaced gasket.
Construction/Loadline › Structures › Manhole
Issued 21 October 2008 Resolved
Replace gasket on lazarette hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 27 October 2008
Resolution: Satisfactorily replaced gasket.
Construction/Loadline › Hull › Weld
Issued 21 October 2008 Resolved
Weld all fractures as noted in lazarette.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 27 October 2008
Resolution: Welds completed satisfactorily.
Construction/Loadline › Hull › Weld
Issued 21 October 2008 Resolved
Weld fractures as noted in the bow space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 27 October 2008
Resolution: Welds completed satisfactorily.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 October 2008 Resolved
Total persons on board vessel reduced to 20 people due to 5 defective PFD's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 27 October 2008
Resolution: Replaced 6 PFD''s for a total of 26 servicable PFD''s onboard.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2007 Resolved
Make permanent repairs to 2 clad welded areas in the aft lazarette fwd bulkhead port and stbd sides, during next drydock.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 23 August 2007
Resolution: repairs completed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 October 2006 Resolved
Make permanent repairs to 2 clad welded areas in the aft lazarette fwd bulkhead port and stbd sides, during next dry dock.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 19 March 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 4 October 2006 Resolved
Prove proper operation of bilge overboard discharge valve.
Action required: 705 - Other - as specified
Due 11 October 2006
Resolved 5 October 2006
Resolution: Vsl has installed a new bilge overboard discharge valve.
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2004 Resolved
Repair cracked weld located on 1st vertical frame on inside of transom.
Due 19 September 2005
Resolved 18 October 2004
Resolution: Corrected on the spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 October 2004 Resolved
Provide visual and audible alarms at operating station for all bilge high level alarms.
Due 18 November 2004
Resolved 29 October 2004
Electrical › Electrical Distribution System (service)
Issued 4 November 2002 Resolved
Provide cover/cap or remove shoretie connection. LEGACY COMPONENT DESC: Shore Connection Box
Action required: 705 - Other - as specified
Due 4 November 2003
Resolved 19 September 2003
Documentation › Logs/Records
Issued 4 November 2002 Resolved
Conduct training/drills and maintain traning log.
Action required: 705 - Other - as specified
Due 4 November 2003
Resolved 19 September 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 November 2002 Resolved
Update first aid supplies with Coast Guard approved kit.
Action required: 705 - Other - as specified
Due 4 November 2003
Resolved 19 September 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.