Records from 1986 to 1996. Most recent: inspection, 10 March 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
10 March 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 884844
8 September 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 383542
12 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379530
12 June 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1187109
21 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 378415
30 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 146847
8 August 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 369263
8 August 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1446112
8 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 473203
19 March 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 365256
13 June 1993
Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 827274
18 February 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 356494
26 September 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 485631
28 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955677
27 April 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1266020
25 April 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 343302
25 April 1991
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 928760
3 August 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 906339
3 April 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 496915
8 May 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1206962
5 May 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892158
8 February 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 511839
3 February 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1327748
2 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 321067
1 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324749
8 June 1987
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1336457
10 November 1986
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 490811
20 June 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 309625
Fire Fighting
Issued 12 June 1995
Resolved
HAVE SELF CONTAINED BREATHING APPARATUS PROFESSIONLY SERVICED. PROVIDE LOCAL COAST GUARD WITH COPY OF SERVICING REPORT. BCH & IBC CODE.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Deck/Cargo
Issued 12 June 1995
Resolved
PRIOR TO LOADING ANY CARGOES REQUIRING CARGO HIGH LEVEL ALARM AS PER 46 CFR153 TABLE 1, MAKE ALARM AUDIBLE & VISUAL ON OPEN DECK. 46 CFR 153.408.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Deck/Cargo
Issued 12 June 1995
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF 2 CARGO PUMP EMERGENCY SHUTDOWN STATIONS IN PRESENCE OF U.S. COAST GUARD PRIOR TO DISCHARGING CARGO. 46CFR153.296
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Documentation
Issued 12 June 1995
Resolved
PROVIDE ON BOARD CURRENT COPY OF APPROVAL LETTER FOR VESSEL RESPONSE PLAN.
Condition: Unknown
Due 12 June 1995
Resolved 15 June 1995
Documentation
Issued 12 June 1995
Resolved
SUBMIT NEW LIST OF PRODUCTS DATED 14 APR 94 AND APPENDIX #80430 TO U.S. COAST GUARD MARINE SAFETY CENTER FOR APPROVAL & ISSUANCE OF NEW SUBCHAPTER O ENDORSEMENT. 46CFR153.900
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 12 June 1995
Resolved
PROVIDE PROPER SIZE PLUGS FOR ALL CARGO, FUEL FILL PIPE, FUEL VENTS & FUEL OVERFLOW DISCHARGE CONTAINMENT PAN DRAINS. FOR NEXT LOADING AT PAKTANK, MAKE TEMPORARY REPAIRS TO CARGO DISCHARGE CONTAINMENT PAN. ANY WELDING TO BE IN ACCORDANCE WITH NFPA 306. 33CFR155.310 & 33CFR155.3210.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Electrical
Issued 12 June 1995
Resolved
TIGHTEN GLOBE & COVER ON EXPLOSIVE PROOF LIGHT FIXTURE IN PAINT LOCKER. SOLAS II-1 REG 45.
Condition: Unknown
Due 12 June 1995
Resolved 15 June 1995
Deck/Cargo
Issued 12 June 1995
Resolved
PRIOR TO USING ANY OF VESSEL'S CARGO HOSES, RENEW REQUIRED MARKINGS AS PER 33 CFR 155.800 & 33 CFR 155.320.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Electrical
Issued 12 June 1995
Resolved
REPLACE MISSING LIGHT COVERS IN ENGINEROOM TO SATISFACTION OF LOCAL OCMI.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Engineering
Issued 21 May 1995
Resolved
MAKE PERMANENT REPAIRS TO OWS (CRACK IN #2 TANK) TO THE SATISFACTION OF CLASSIFICATION SOCIETY. MARPOL 73/78 ANNEX I/16.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Engineering
Issued 21 May 1995
Resolved
MAKE PERMANENT REPAIRS TO 3 FUEL OIL VENTS ON POOP DECK STBD SIDE. IN ACCORDANCE WITH ICLL 66 REG 19.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Documentation
Issued 18 February 1993
Resolved
NO NVIC 8-92 VESSEL RESPONSE PLAN ON BOARD
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Deck/Cargo
Issued 5 May 1989
Resolved
UPON ENTRY AT NEXT U.S. PORT HAVE CARGO PUMP ROOM GAS FREE AND INSPECTED BYA U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Documentation
Issued 2 February 1988
Resolved
EXPIRED SUBCHAPTER "O" ENDORSEMENT TO THE LOC
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Documentation
Issued 8 June 1987
Resolved
SUBMIT COPY OF IMO CERTIFICATE OF FITNESS ISSUED UNDER MEPC RESOLUTION 20(22) TO COMMANDANT (G-MTH) FOR ISSUANCE OF NEW SUBCHAPTER "O" ENDORSEMENTTO LETTER OF COMPLIANCE.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Deck/Cargo
Issued 8 June 1987
Resolved
PROVIDE UNDERWATER DISCHARGE OUTLET THAT MEETS 46 CFR 153.470.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987