Records from 1981 to 2008. Most recent: inspection, 13 November 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
13 November 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3362467
21 May 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2935999
3 May 2007
Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2921665
18 April 2007
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2910272
9 June 2006
Re-Inspection · Damage Survey · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2550419
5 October 2004
Hull Examination · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2213696
19 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850194
11 June 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1629269
14 December 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1476655
14 June 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395760
21 June 2000
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1417085
1 December 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395313
10 June 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 813077
23 June 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793406
11 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793274
25 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 777473
22 July 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1089075
8 July 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1087542
13 June 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 879206
7 June 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875933
13 June 1995
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 882712
29 July 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 863097
14 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1171705
15 June 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1151142
2 December 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831622
10 July 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1256308
16 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945286
1 August 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1243883
11 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1333402
19 June 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1241099
24 May 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 924422
20 June 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352335
25 October 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1201242
28 July 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1032392
15 June 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 890320
3 December 1987
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337605
23 June 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1313786
7 May 1987
Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1021514
3 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991051
2 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975190
11 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271448
16 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971025
Engineering › Bilge Water Management System › Not Operational
Issued 21 May 2007
Resolved
Make repars to non- operative bilge suction system.
Due 21 May 2007
Resolved 21 May 2007
Resolution: System repaired and re-tetsed sat.
Lifesaving › Lifebuoys › Not on Board
Issued 5 October 2004
Resolved
Provide a lifebuoy with waterlight and 60 ft of floating line.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 5 October 2004
Resolved
Provide ball/check valve for vent for forepeak/main cabin.
Condition: Unknown
Due 19 October 2004
Resolved 10 February 2005
Construction/Loadline › Structures › Scuttle
Issued 5 October 2004
Resolved
Provide a capture chain for forepeak scuttle cover.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 October 2004
Resolved
Service 15 lb portable CO2 extinguisher in engine room.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 October 2004
Resolved
Move battery box for generator from bilge to a higher location.
Condition: Improper Installation
Due 19 October 2004
Resolved 10 February 2005
Engineering › Steering Gear System › Rudder Stock
Issued 5 October 2004
Resolved
Tighten port rudder post packing gland.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 October 2004
Resolved
Reinstall stern deck rail.
Condition: Unknown
Due 19 October 2004
Resolved 10 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 October 2004
Resolved
Reinstall stern light.
Condition: Unknown
Due 19 October 2004
Resolved 10 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 5 October 2004
Resolved
Prove proper operation of high level bilge alarm.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 5 October 2004
Resolved
Prove proper operation of engine-driven bilge pump.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Engineering › Bilge Water Management System › Strainer
Issued 5 October 2004
Resolved
Clean main cabin bilge strainer area.
Condition: Improper/Lack of Maintenance
Due 19 October 2004
Resolved 10 February 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 5 October 2004
Resolved
Reinstall toilet.
Due 19 October 2004
Resolved 10 February 2005
Construction/Loadline › Structures
Issued 19 June 2003
Resolved
Properly repair forepeak hatch.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Hatch dogs down and is operational.
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 June 2003
Resolved
Provide deviation card for magnetic compass.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Deviation card is provided.
Fire Fighting › Fire Pumps › Impeller
Issued 19 June 2003
Resolved
Prove proper operation of fire pump NLT25 June.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Proved proper operation of fire pump.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 June 2003
Resolved
Repair stbd MDE belt guard.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Repaired belt guard.
Pollution Prevention/Response
Issued 19 June 2003
Resolved
Remove excess oil from bilges in engine room.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Removed oil from engine room bilges.
Lifesaving › Buoyant Apparatus
Issued 11 June 2002
Resolved
Life float is not in servicible condition and in need of replacement. Vessel's current route does not require L/F and it is to be removed.
Due 11 June 2002
Resolved 11 June 2002
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 December 2001
Resolved
Renew port hose to keel cooler.
Condition: Unknown
Due 28 December 2001
Resolved 28 December 2001
Resolution: Replaced hose to port keeler cooler.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 14 December 2001
Resolved
CLEAN OUT PORT SEA STRAINER.
Condition: Unknown
Due 28 December 2001
Resolved 28 December 2001
Resolution: Port sea strainer cleaned out.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 14 December 2001
Resolved
Add a clamp to port stuffing shaft coupling hose.
Condition: Improper/Lack of Maintenance
Due 28 December 2001
Resolved 28 December 2001
Resolution: Installed a new clamp.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 14 December 2001
Resolved
Renew flexible hose to starboard stuffing shaft coupling.
Condition: Unknown
Due 28 December 2001
Resolved 28 December 2001
Resolution: Renewed flexible hose to starboard stuffing shaft coupling.
Lifesaving
Issued 14 June 2001
Resolved
Properly maintain the connection hooks and the rescue ladder.
Condition: Unknown
Due 14 June 2001
Resolved 15 June 2001
Construction/Loadline
Issued 14 June 2001
Resolved
Prove operation of the fixed bilge pump.
Condition: Unknown
Due 14 June 2001
Resolved 15 June 2001
Fire Fighting
Issued 14 June 2001
Resolved
Provide a B-I fire extinguisher for the bridge.
Condition: Unknown
Due 14 June 2001
Resolved 15 June 2001
Fire Fighting
Issued 21 June 2000
Resolved
Properly mount B II fire extinguishers in wheelhouse.
Condition: Unknown
Due 28 June 2000
Resolved 3 July 2000
Construction/Loadline
Issued 21 June 2000
Resolved
Prove proper operation of high bilge alarms in E/R and laz.
Condition: Unknown
Due 28 June 2000
Resolved 3 July 2000
Electrical
Issued 21 June 2000
Resolved
Properly install blank in aft switchboard in E/R.
Condition: Unknown
Due 28 June 2000
Resolved 3 July 2000
Electrical
Issued 21 June 2000
Resolved
Properly install protective cage or plastic dome on stbd aft deck light.
Condition: Unknown
Due 28 June 2000
Resolved 3 July 2000
Lifesaving
Issued 13 June 1996
Resolved
MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED CREW MEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Navigation
Issued 13 June 1996
Resolved
MAKE PERMANENT REPAIR TO VESSEL'S WHISTLE. UNTIL SUCH TIME, THE VESSEL SHALL CARRY A PORTABLE HORN.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Electrical
Issued 13 June 1996
Resolved
MAKE PERMANENT REPAIR TO 4.5 KW AC GENERATOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 13 June 1996
Resolved
REPLACE BROKEN PADDLE FOR THE LIFE FLOAT
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 13 June 1996
Resolved
REPLACE REFLECTIVE TAPE ON THE LIFE FLOAT
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 13 June 1996
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED IN ACCORDANCE WITH 46 CFR 176.810.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 13 June 1996
Resolved
INSTALL A SECOND B II PORTABLE FIRE EXTINGUISHER FOR THE ENGINE ROOM AREA.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 13 June 1996
Resolved
REPLACE BATTERY IN THE WATERLIGHT FOR THE LIFE FLOAT WITH AN APPROVED UNIT.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Electrical
Issued 7 June 1996
Resolved
REPLACE SPICES ON ELECTRICAL CABLE FOR STERN LIGHT IN COMPLIANCE WITH 46 CFR PART 183.
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
REWELD BROKEN WELDS ON PORT INBOARD ENGINE FRAME AND STARBOARD OUTBOARD FRAME.
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
REWELD SUPPORT BRACKETS WITH PARTED WELDS IN THE SECOND COMPARTMENT.
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
CLEAN AREA UNDER AND AROUND BILGE STRAINER IN THE SECOND COMPARTMENT (PASSENGER SPACE).
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Engineering
Issued 7 June 1996
Resolved
REPLACE GROUND WIRE ON THE FUEL OIL TANK FILL LINE.
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Deck/Cargo
Issued 7 June 1996
Resolved
REPAIR OR REPLACE GAKET ON THE HATCH COVER ABOVE THE PORT ENGINE.
Condition: Unknown
Due 15 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 13 June 1995
Resolved
VEE OUT AND REWELD FRACTURES TO WELDS ON NO. 1 TRANSVERSE FRAME, PORT SIDE,IN BOW COMPARTMENT NO LATER THAN 13 JULY 1995.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 13 June 1995
Resolved
VEE-OUT AND REWELD FRACTURE ON BASE OF AFT DECK STANCION NO LATER THAN 13 JULY 1995.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Engineering
Issued 13 June 1995
Resolved
PROPERLY LABEL REMOTE FUEL OIL SHUT OFF VALVE NO LATER THAN 27 JUNE 1995.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 13 June 1995
Resolved
PROPERLY WIRE, SPLICE, AND CONNECT WIRING ON STARBOARD SIDE MAIN BATTERIES NO LATER THAN 27 JUNE 1995.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Engineering
Issued 13 June 1995
Resolved
REPLACE EXHAUST LAGGING ON PORT ENGINE INBOARD EXHAUSE PIPE, AND STARBOARD ENGINE OUTBOARD PIPE, NO LATER THAN 27 JUNE 1995.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Engineering
Issued 29 July 1994
Resolved
REPAIR FRACTURE IN FUEL TANK, LOWER AFT P/S MOUNTING BRACKET.
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Construction/Loadline
Issued 29 July 1994
Resolved
SECURE BILGE STRAINER IN STEERING COMPARTMENT.
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Navigation
Issued 29 July 1994
Resolved
REPLACE BOTH CUTLESS BEARINGS.
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Fire Fighting
Issued 14 June 1994
Resolved
REPLACE MISSING B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 14 June 1994
Resolved 30 June 1994
Engineering
Issued 15 June 1993
Resolved
REPLACE MAIN ENGINE EXHAUST LAGGING WHERE MISSING.
Condition: Unknown
Due 15 July 1993
Resolved 24 June 1993
Construction/Loadline
Issued 15 June 1993
Resolved
PROVIDE A STOP/CHECK VALVE FOR THE ELECTRIC BILGE PUMP SUCTION LINE IN THE ENGINE ROOM IN ACCORDANCE WITH 46 CFR 182.25-5(C).
Condition: Unknown
Due 22 June 1993
Resolved 24 June 1993
Engineering
Issued 16 June 1992
Resolved
REPLACE MAIN ENGINE EXHAUST LAGGING WHERE MISSING.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Fire Fighting
Issued 16 June 1992
Resolved
PROVIDE B-II PORTABLE FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Engineering
Issued 16 June 1992
Resolved
PROPERLY SECURE FUEL TANK IN WAY OF FORWARD BRACKETS.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Accommodation/Occupational Safety
Issued 16 June 1992
Resolved
PROVE OPERATION OR REMOVE MSD.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Fire Fighting
Issued 16 June 1992
Resolved
RENEW FLAME SCREEN TO FUEL TANK VENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Engineering
Issued 16 June 1992
Resolved
REPAIR FUEL LEAKS IN WAY OF PORT AND STARBOARD MAIN ENGINE FUEL FILTERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Unknown
Issued 15 June 1988
Resolved
THREE HATCHES ON DECK DID NOT HAVE THE SECURING DEVICE REQUIRED BY 46CFR171.124(B)(1).
Condition: Unknown
Due 15 June 1988
Resolved 15 June 1988
Engineering
Issued 23 June 1987
Resolved
STENCIL EMERGENCY FUEL SHUT OFF VALVE LOCATION.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Lifesaving
Issued 23 June 1987
Resolved
PROVIDE CG APPROVED BOUYANT APPRATUS.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Engineering
Issued 23 June 1987
Resolved
REPLACE SCREEN FOR FUEL TANK VENT.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Construction/Loadline
Issued 7 May 1987
Resolved
PROVE THICKNESS OR REPAIR DISHED IN STERN AREA THREE FEET ABOVE KEEL IN STERN AREA.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Engineering
Issued 7 May 1987
Resolved
RESECURE PORT ENGINE REAR MOUNTING BOLT PORT SIDE
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987