MARCHELLE

MARCHELLE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in October 2020, along with 92 deficiencies — 7 with no resolution recorded —.

Records from 1985 to 2020. Most recent: inspection, 7 October 2020.

Built
1976
Last inspected
7 October 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7480
Flag
UNITED STATES
367362930
Maury page id
psix-53659

Inspections, by type

…with no type recorded10
…past their stated due date7
Years with a record 34 calendar years (1985–2020)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.1 ft × 16.1 ft × 5.8 ft
Registered tonnagegross 31 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLEBE POINT BOAT COMPANY · BURGESS, VA, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOLOMONS, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7480MMSI 367362930 · active · compulsorily equipped · granted 1 September 2020, expires 1 September 2030
WDK5383MMSI 367362930 · cancelled · voluntarily equipped · granted 30 October 2018, cancelled 26 February 2020
WBY8059MMSI 367362930 · terminated · compulsorily equipped · granted 14 June 2008, cancelled 28 August 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 69

7 October 2020 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7073507
31 August 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7046736
23 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6934227
15 October 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6831972
17 April 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6666132
14 December 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6598345
28 March 2018 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6403372
16 January 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6341543
23 September 2017 Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 6273401
17 January 2017 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6072634
28 March 2016 Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5879817
19 October 2015 Internal Structural Exam · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5745856
13 May 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4859820
11 June 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4340519
1 June 2012 Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4330830
1 November 2010 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3883996
1 December 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3650556
7 November 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3362204
14 May 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3208010
20 November 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3102141
10 May 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2650408
8 November 2005 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2530729
1 August 2005 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2447998
3 November 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2237911
26 August 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2177688
23 June 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2107883
14 October 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1928116
30 May 2003 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1826494
13 June 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1635762
5 November 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1665035
7 August 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1069621
1 February 2001 Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 4713514
27 April 2000 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1050752
27 April 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1413755
9 March 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1440274
8 August 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 150868
3 July 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 990
13 April 1999 Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1128667
5 March 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 802677
12 January 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 789490
25 July 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 91742
30 March 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 787278
10 March 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 785941
15 April 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435931
10 March 1997 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1419730
12 March 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1355701
30 January 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1191910
1 March 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868514
14 March 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868682
11 March 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868798
27 May 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 836693
27 May 1993 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1144797
22 April 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 828139
14 April 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 958033
2 May 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1223613
26 April 1991 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 900141
2 April 1991 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1233153
24 April 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 912853
17 April 1990 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1223739
20 April 1989 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1339682
29 March 1989 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 889593
13 April 1988 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1035954
5 May 1987 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1326226
15 April 1987 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1308674
30 September 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1314915
8 May 1986 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 992591
23 April 1986 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1000517
8 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982835
27 March 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1288691

Deficiency record · 92

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2020 No resolution recorded
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. A new installation of a 110ac power inverter was found improperly installed behind the HVAC system, with the negative (black) lead disconnected from the inverter and loose behind the cabinet while the circuit was live. 46 CFR 200(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 7 October 2020 No resolution recorded
The construction and arrange of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Multiple areas of deck deterioration noted throughout the deck of the vessel, to include 4 areas on the port side, 1 area forward of the fuel shut offs, 1 area on the platform at the top of the ladder, and 3 areas on the starboard side. Submit repair proposal to this office.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2020 No resolution recorded
The construction and arrange of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Gaps were observed in portside hull planking. Submit repair proposal to this office. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 October 2020 No resolution recorded
The construction and arrange of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. The starboard aft most framing member in the forepeak was rotting against the hull sheathing. Submit a repair proposal to this office. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2020 No resolution recorded
The construction and arrange of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Grounding/bonding wire for port engine was disconnected, resting in bilge, and creating an avenue for stray current. 46 CFR 177.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 October 2020 No resolution recorded
Every vessel subject to the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. FCC Safety Radio Certificate issued with wrong call sign. 46CFR184.502,47CFR80.903
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2020 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10, which requires 1-year maintenance. 1A:10B:C portable extinguisher at operating station was not annually serviced. 46 CFR 176.810(b)(1), NFPA 10/7.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2020
Resolved 7 October 2020
Resolution: Extinguisher replaced with properly serviced extinguisher of proper size and classification.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot. Vessel missing U.S. Coast Pilot. Extracts for the areas to be transited may be provided instead of the complete publication. U.S. Coast Pilot was last updated in 2015. 46 CFR 184.420(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 13 October 2020
Resolution: Updated sections (as of October 2020) of U.S. Coast Pilot were printed for the areas of transit for the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2020 No resolution recorded
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel was not in an adequate condition to get underway and conduct drills or power trials. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 7 October 2020
Resolution: New station license was present at COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2018 Resolved
Vessel required to have one waterlight attached to the lifering. Waterlight does not work.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2018
Resolved 17 April 2019
Resolution: Witnessed properly attached and operable waterlight.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 December 2018 Resolved
Wood vessel required to have bilge level indicator in all spaces. Bilge indicator didn't work in automatic mode. Forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2018
Resolved 16 December 2018
Resolution: Switch replaced prior to departure. Operated properly.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 28 March 2018 Resolved
Improper ground on fuel tank. Determine proper grounding of fuel tank and properly ground.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2018
Resolved 18 April 2018
Resolution: Vessel installed proper ground for fuel tank.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 28 March 2018 Resolved
Vessel installing new A/C and heater system. Submit load analysis and one line diagram to MSC for review prior to installation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 14 May 2018
Resolution: Cleared from previous inspeciton.
Construction/Loadline › Hull › Stiffener
Issued 28 March 2018 Resolved
Rot found on deck support and bottom stringer submit repair proposal to local OCMI for review.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2018
Resolved 18 April 2018
Resolution: Vessel owner repaired deck support.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2018 Resolved
Rotted strip planking found on port quarter. Remove rub rail, crop rotted plank and submit repair proposal to local OCMI for review.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2018
Resolved 18 April 2018
Resolution: Vessel owner satisfactorily repaired rotted strip planking.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 March 2018 Resolved
Angel hair found on aft bulwark and engine compartment.. Remove angel hair afffected wood and treat as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 18 April 2018
Resolution: [name withheld] being removed and wood treatment applied.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 March 2018 Resolved
Various bulkead penetrations not properly sealed in E/C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 18 April 2018
Resolution: Owner properly sealed bulkead penetrations.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 March 2018 Resolved
Due to high water at shipyard, vessel's transom, shafts, propellors struts and hull bottom planks were not accessable for inspection.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2018
Resolved 29 March 2018
Resolution: Attended vessel and completed dry-dock/ISE
Lifesaving › Buoyant Apparatus › Serviceable
Issued 16 January 2018 Resolved
Replace 10 person buoyant apparatus. Vessel restricted to carrying 18 passengers until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2018
Resolved 26 April 2018
Resolution: Verified validity and proper labeling of newly purchased 12-person life float. ALL SAT.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 16 January 2018 Resolved
Vessel is installing new A/C and cabin heating; exposed wiring in engine compartment. Ensure electrical connections are to satisfaction to CGMI
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 22 April 2019
Resolution: Closed due to sytem not being hooked up.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 January 2018 Resolved
Remove electrical wiring from engine room bilge and properly secure wiring.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2018
Resolved 18 April 2018
Resolution: Attended vessel and cleared above deficiency.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 16 January 2018 Resolved
Anchor windlass grounding wire not properly secured.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2018
Resolved 18 April 2018
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 January 2018 Resolved
Conduct drills
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 26 April 2018
Resolution: Verified proper response actions of U/W Man Overboard Drill and Fire Drill. ALL SAT
Engineering › Steering Gear System › Rudder
Issued 17 January 2017 Resolved
Starboard rudder post leaking water excessively. Repack/tighten as needed.
Condition: Improper/Lack of Maintenance
Due 24 January 2017
Resolved 29 March 2017
Resolution: Vessel's rudder post no longer leaking excessively.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 January 2017 Resolved
Port fuel shut off valve not closing properly. Ensure shut off valve is properly closes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2017
Resolved 29 March 2017
Resolution: Owner/operator replaced inop valve.
Lifesaving › Lifebuoys › Serviceable
Issued 17 January 2017 Resolved
Grab line on life ring is worn. Replace/renew as needed.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 29 March 2017
Resolution: Owner/operator replaced ring buoy.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 January 2017 Resolved
Vessel's drug consortium compliance letter expired. PRovide evidence that vessel crew is enrolled in a valid drug and alcohol program.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 29 March 2017
Resolution: Vessel's crew currently enrolled in consortium
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 January 2017 Resolved
Vessel's emergency escape not properly marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 29 March 2017
Resolution: Owner/operator properly marked em. escape.
Construction/Loadline › Hull › Side Shell
Issued 28 March 2016 Resolved
Refasten frams to hull Port and starboard side from Bow to 7th frame aft of bow.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Attended vessel and inspected the installation and attachement of fwd frames idendified during the dry-dock inspection. all sat.
Construction/Loadline › Hull › Keel Plate
Issued 28 March 2016 Resolved
Replace last 36 inches of wrom shoe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Attended vessel at McCready's rail, verified the installation of aft 36 in of worm shoe. all sat.
Construction/Loadline › Hull › Keel
Issued 28 March 2016 Resolved
Submit plan to address cracked inner bow stem horn.
Due 16 April 2016
Resolved 14 April 2016
Resolution: Inspected the agreed upon temp repair made to the inner bow stem horn. all sat. will evaluate at next years annual for further service as a permanent repair.
Construction/Loadline › Hull › Transverse Frame
Issued 19 October 2015 Resolved
Vessel is required to be in sea worthy condition IAW 46CFR176, Frames are detached from hull planking. Provide repair proposal for approval to reattach all frams port and starboard aft of generator to stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Identified frames where thru bolted to hull. all sat
Construction/Loadline › Hull › Transverse Frame
Issued 19 October 2015 Resolved
Repair cracked frome IWO generator port side.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Cracked frame was refastend and thru bolted. all sat
Construction/Loadline › Hull › Side Shell
Issued 19 October 2015 Resolved
Repair or replace wasted hull plank above chine on port side IWO cracked frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Plank edge was cleaned out and edge glued. all sat
Construction/Loadline › Hull › Side Shell
Issued 19 October 2015 Resolved
Reseal and refasten hull planking fwd starboard side under lower salon seating and below port lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Areas idendified during COI inspection were thru bolted. all sat
Construction/Loadline › Hull › Side Shell
Issued 13 May 2014 Resolved
Repair/Replace Stem at deckline. Stem soft with Bondo.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 3 July 2014
Resolution: Received email picture of completed repairs.
Construction/Loadline › Structures › Deck Plating
Issued 13 May 2014 Resolved
Stbd side forward transition, (step), wasted at deck, RFenew and repair as original.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 3 July 2014
Resolution: Received email picture of completed repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 13 May 2014 Resolved
Stbd side forward engineroom transverse beam wasted. Repair as original.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 3 July 2014
Resolution: Received email picture of completed repairs.
Engineering › Steering Gear System › Rudder
Issued 1 June 2012 Resolved
Through bolts for rudder blocks have two nuts that are wasted and need to be replace as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2012
Resolution: Installed two new bolts, nuts, and washers on rudder post. Filled in through holes with 5200.
Construction/Loadline › Hull › Keel
Issued 1 June 2012 Resolved
Worm shoe is wasted, and need to be replaced as original in two locations; fwd and aft as marked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2012
Resolution: Received pictures via e-mail. 5200 in between the new oak and the keel with 3/16 lag bolts with west system filler in screws and lag holes. Repairs made to the marine inspector satisfaction. See case folder for pictures.
Construction/Loadline › Hull › Transverse Frame
Issued 1 June 2012 Resolved
Angel hair found in multiple frames, knees, and longitudinal through out engine room. Sand to good wood , and treat as required.
Condition: Improper/Lack of Maintenance
Due 29 June 2012
Resolved 29 June 2012
Resolution: Repairs compelted.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 June 2012 Resolved
Angel hair found in multiple frames, stantions, and longitudinals through out engine room aft to stern. Sand and tread as required.
Condition: Improper/Lack of Maintenance
Due 29 June 2012
Resolved 29 June 2012
Resolution: Sanded frames, stantions and longitudinals to good wood, and treated with wood preserver.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 20 November 2007 Resolved
Provide two, current alcohol testing kits or provide written program stating an agreement to test for alcohol following a SMI with the local law enforcement agency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2007
Resolution: Owner provided letter detailing testing procedures for alcohol in the event of an SMI.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 May 2006 Resolved
Provide proof of double clamping exhaust line on Stb MDE.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 24 May 2006
Resolution: Exhaust line was double clamped.
Engineering › Bilge Water Management System › Hose
Issued 10 May 2006 Resolved
Provide a double clamp on the aft bilge pump.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 24 May 2006
Resolution: Bilge pump was double clamped.
Stability › Watertight Integrity › General
Issued 10 May 2006 Resolved
Provide a permananent cap on valve penetrating stb side hull in engine room.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 24 May 2006
Resolution: Through hull fitting was capped.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2006 Resolved
Remove unused conductor from engine room.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 24 May 2006
Resolution: Unused condoctor was removed from engine room.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2006 Resolved
Tighten rails on foreward deck and upper grab rail heading into bridge.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 24 May 2006
Resolution: Rails were tightened.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 November 2005 Resolved
3 life jackets failed due to corroded clip. Vessel is restricted to carrying 48 passengers until life jackets are replaced. Life jackets were destroyed in the presence of the inspectors.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 24 December 2005
Resolution: Owner provided new life jackets.
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2004 Resolved
Provide valid FCC Safety certificate.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 7 December 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 November 2004 Resolved
Provide valid Certificate of Documentation.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 7 December 2004
Lifesaving › Lifefloat › Retroreflective Material
Issued 3 November 2004 Resolved
Renew retro-reflective tape on 8-man life float.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 7 December 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 November 2004 Resolved
Renew retro-reflective tape on 13 selected adult life jackets.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 7 December 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 October 2003 Resolved
Vessel failed to schedule required 13 NOV 2002 reinspection.
Due 15 October 2004
Resolved 1 August 2005
Resolution: Admin closed. LOW issued.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 October 2003 Resolved
Prove operation of generator.
Due 1 May 2004
Resolved 20 November 2003
Engineering › Shafting/Propeller Arrangements
Issued 8 October 2003 Resolved
Tighten port shaft packing.
Due 22 October 2003
Resolved 9 October 2003
Engineering › Freshwater System (air cooling)
Issued 8 October 2003 Resolved
Repair starboard exhaust clamps at aft end such that no water leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 9 October 2003
Lifesaving › Buoyant Apparatus
Issued 8 October 2003 Resolved
Provide 18 feet of line for life float and BA water lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 9 October 2003
Lifesaving › Hand Flares
Issued 8 October 2003 Resolved
Provide 3 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 9 October 2003
Accommodation/Occupational Safety
Issued 8 October 2003 Resolved
Remove oil from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 9 October 2003
Electrical
Issued 8 October 2003 Resolved
Clean battery box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2003
Resolved 9 October 2003
Construction/Loadline
Issued 9 March 2000 Resolved
PROVIDE HANDLE FOR ACCESS HATCH LEADING TO EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Navigation
Issued 9 March 2000 Resolved
PROVIDE CURRENT CHARTS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
CONDUCT UNDERWAY INSPECTION OF MDE'S, STEERING AND HULL.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 10 March 1998 Resolved
PROVIDE WATERLIGHT WITH 18' LINE FOR BUOYANT APPARATUS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1998 Resolved
SERVICE ALL FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998 Resolved
PROVIDE 2 FLASHLIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Engineering
Issued 10 March 1998 Resolved
CONDUCT OPERATIONAL UNDERWAY TESTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Navigation
Issued 10 March 1998 Resolved
REPAIR SIDE LIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998 Resolved
CONDUCT SATISFACTORY UNDERWAY DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1997 Resolved
Portable fire extinguishers were not recently serviced as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Deck/Cargo
Issued 10 March 1997 Resolved
The hydraulic hose to the anchor motor was bulged and slightly leaking._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Electrical
Issued 10 March 1997 Resolved
Unable to test due to generator being winterized,_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Lifesaving
Issued 12 March 1996 Resolved
The 8 man bouyant apparatus is worn and must be replaced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Electrical
Issued 12 March 1996 Resolved
An operational test of the generator is required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Engineering
Issued 12 March 1996 Resolved
The flame screen on the fuel tank vent is missing._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Engineering
Issued 12 March 1996 Resolved
The ground wire to the fuel tank is not connected due to corrosion._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Lifesaving
Issued 12 March 1996 Resolved
The 3 orange smoke flares are expired._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 12 March 1996 Resolved
The flow switch to the center compartments bilge pump is inoperable._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Engineering
Issued 12 March 1996 Resolved
The fuel shut off valves to the main engines was not marked._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Electrical
Issued 12 March 1996 Resolved
An extension cord wire is being used to power a piece of equipment under the control console in the wheel house._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Navigation
Issued 12 March 1996 Resolved
The vessel did not have a current copy of 46 CFR (T-Boat Regs) on board as required._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1996
Resolved 5 April 1996
Engineering
Issued 26 April 1991 Resolved
REDUCE LEAKAGE OF WATER AT STARBOARD SHAFT STUFFING BOX, 6 TO 8 DROPS PER MINUTE RECOMMENDED.
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Engineering
Issued 26 April 1991 Resolved
PROVIDE 30X30 MESH SCREEN ON FUEL OIL TANK VENT. THIS REQUIREMENT SHALL BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Engineering
Issued 2 April 1991 Resolved
REPLACE 3/4" PVC PIPING ON BILGE SYSTEM IN ENGINEROOM WITH 1" PIPING AS REQUIRED IN REGUALTIONS
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Engineering
Issued 2 April 1991 Resolved
PROVIDE FLAME IMPINGEMENT BOWLS FOR BOTH FUEL FILTERS.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Engineering
Issued 2 April 1991 Resolved
PROVIDE PLUGS INSTEAD OF PETCOCKS FOR BOTH FUEL FILTERS.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Navigation
Issued 17 April 1990 Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION VHF RADIO. DO NOT CARRY PASSENGERS UNTIL THIS DEFICIENCY IS CORRECTED AND DEMONSTRATED TO [name withheld].
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 20 April 1989 Resolved
REPLACE GRABLINES ON TWO LIFERINGS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Fire Fighting
Issued 23 April 1986 Resolved
REPLACE NON MARINE TYPE BII FIRE EXTINGUISHER WITH A MARINE TYPE EXTINGUISHER.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.