MAURY USCG vessel records
← All vessels

ABIGAIL MARIE

Built
1981
Last inspected
30 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4571
Flag
UNITED STATES
Maury page id
psix-53679

Documentation record

Registered dimensions (L × B × D)102.6 ft × 26.0 ft × 6.8 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPASS CHRISTIAN SHIPBUILDING INC · PASS CHRISTIAN, MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

30 April 2025 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8120323
10 February 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8070632
22 January 2025 Inclining Experiment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8068950
10 May 2023 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685547
10 May 2023 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7690973
11 January 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7620057
15 September 2022 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7559298
14 September 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7563103
16 August 2021 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7288331
6 April 2021 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7171458
27 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044203
30 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6899919
13 November 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6855974
20 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816962
23 May 2019 Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6696762
29 April 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6672755
25 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6547129
20 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6544578
7 September 2017 Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6260890
24 March 2017 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6110932

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2025 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. A stop-check valve located at a control point or manifold will meet the requirements for both a stop valve and a check valve. Lazarette, E/R, and E/R alleyway bilge suction piping are not fitted with check valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2025
Resolved 21 March 2025
Resolution: Verified installation of all three check valves.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 February 2025 Resolved
Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 21 March 2025
Resolution: Verified bulkhead was vapor tight.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 February 2025 Resolved
A vessel of more than 19.8 meters (65 feet) in length must have at least one fire axe located in or adjacent to the primary operating station. Fire axe was found in main deck gear locker and not kept in or adjacent to the primary operation station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 13 February 2025
Resolution: Received picture of fire axe mounted outside of operating station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2025 Resolved
Complete but simple instructions for the operation of a extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Each control valve to a distribution line must be marked to indicate the space served. Local and remote actuator pull box for fixed CO2 system did not have instructions posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 21 March 2025
Resolution: Verfied signage for CO2 activation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 February 2025 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. Vessel's name was not marked on port and starboard bow.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 21 March 2025
Resolution: Verified name of vessel on port and stbd bow.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 January 2023 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not scheduled an Annual Inspection and has lapsed. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2025
Resolution: COI inspection completed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 January 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 March 2025
Resolution: Vessel's latest stability test does not permit operations above a Limited Coastwise route.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2023 Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel has not submitted plan for lithium ion battery charging. Vessel has been limited to a Limited Coastwise route and no overnight passengers until lithium ion charging plan has been verified by a Marine Inspector. 46 CFR 185.364
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: No commercial lithium ion batteries used onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 January 2023 Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to (Listed in cite). Vessel has not shown to have met training requirements. Vessel has been limited to a Limited Coastwise route and no overnight passengers until training has been verified by a Marine Inspector. 36 CFR 185.420(b)
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: COI restriction issued for <6 passengers on oceans/coastwise
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 January 2023 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must:(1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Vessel has been limited to no overnight passengers until monitoring device has been verified by a Marine Inspector. 46 CFR 185.410(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: COI restriction issued for <6 passengers on oceans/coastwise
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2023 Resolved
The master of a vessel described by 46 CFR 175.110(d) must conduct passenger emergency egress drills from the passengers' assigned overnight accommodation spaces prior to beginning an excursion with new passengers. (1)If the passengers are not assigned an overnight accommodation space, the master of a vessel described by 46 CFR 175.110(d) must conduct passenger emergency egress drills from an accommodation space prior to beginning an excursion with new passengers. (2) For the purposes of this section, excursion includes anytime the the vessel gets underway, or anytime passengers remain overnight on the vessel. Provide plan for conducting passenger egress to OCMI. Vessel has been limited to no overnight passengers until passenger egress plan has been verified by a Marine Inspector. 46 CFR 185.507
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: COI restriction issued for <6 passengers on oceans/coastwise
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported a loss of propulsion due to starboard engine failure. Verify cause of engine failure and make necessary repairs. 46 CFR 182.200(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2025
Resolution: Vessel conducted a repower of both main diesel engines.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 August 2020 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck. The emergency lighting in the passageway leading to the engine room was not functioning and needs to be repaired or replaced. 46 CFR 184.30-5(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 28 August 2020
Resolution: Lighting fixture battery replaced and re-installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2020 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of release. There were no operating instructions posted for the fixed CO2 system installed on the vessel. 46 CFR 181.20-15(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 9 September 2020
Resolution: Adequate instructions posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 August 2020 Resolved
Watertight doors and watertight hatches shall be marked on both sides in at least 1-inch letters. Update the verbage on the watertight doors to read "Watertight door-keep closed while underway" so that it reflects the requirements of the stability booklet. 46 CFR 185.30-25(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 9 September 2020
Resolution: Doors were properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 August 2020 Resolved
As appropriate for the intended voyage, all vessels must carry adequate up-to-date charts and nautical publications. The vessel's rules of the road publication is from 2003 and needs to be replaced with an updated version. 46 CFR 185.20-35.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 9 September 2020
Resolution: 2020 version of ROTR placed on the bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2020 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test all boilers and unifired pressure vessels to the extent necessary to determine that their condition is satisfactory and that they are fit for the service for which intended. The pressure gauge on the vessel's air receiver is inoperable and needs to be replaced. 46 CFR 176.25-30.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 2 September 2020
Resolution: Photo documentation (attached) of working gauge was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2020 Resolved
At each inspection the following examinations and tests shall be held: The setting of safety valves or relief valves on boilers and unfired pressure vessels shall be checked. The relief valve for the air receiver did not properly operate and was unable to reseat when lifted. 46 CFR 176.25-30(b)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 9 September 2020
Resolution: Replaced with new pressure relief valve, tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018 Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 January 2020
Resolution: Verified via the NAVCEN AIS website that subject vessel cleared outstanding AIS error.

Recorded names · 1

POINT LOBOS (2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.