09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 September 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel is leaking excessive amount of Carbon Monoxide (CO) into engine room space from damaged exhaust piping on port engine. Marine Inspector’s 4-gas detector indicated CO levels at Elevated CO level poses a serious risk to the crew when accessing space for operating the bilge system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 October 2024
Resolution: Attended vessel and witness operation of port engine. MI the installation of new exhaust piping from the turbo outlet to the rubber exhaust hose on the straight pipe, no exhaust leaks identified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 02 Adult PFDs were found no longer serviceable. Vessel reduced to the carriage of 18 persons until PFDs are replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: New PFDs procured
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child PFDs found stowed in same compartment as Adult PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: Child PFDs relocated
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets, letters and numbers must be at least 2 in high. Child PFDs once relocated need to be marked
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: location marked
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2024
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with
permanent type connectors. Spring clips or other temporary type clamps are not permitted. Port battery found with wing nuts on terminal connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: Terminal nuts replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 September 2024
Resolved
Each deck hatch cover must have securing devices. E/R securing devices are wasted and inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: New securing devices installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 September 2024
Resolved
Each deck hatch cover exposed to the weather must be watertight. Lazarette deck hatch gasket was found detached from cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: gasket reattached
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 September 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10), or 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide proper first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: All required equipment supplied
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 September 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall check the condition of the hull. Discharge penetration for lazarette submersible bilge pump was found holed due to galvanic corrosion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 11 October 2024
Resolution: Overboard penetration repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2024
Resolved
A submersible electric bilge pump shall have a positive shutoff valve is installed at the hull penetration. No valve in laz pump installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Valve installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2024
Resolved
A submersible electric bilge pump shall be permanently mounted in bilge. Bilge pump in laz space was not mounted to hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: pump mounted to hull
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 30 September 2024
Resolved
The certification of inspection and stability letter
shall, in general, be framed under glass or other transparent material and posted in a conspicuous place. Vessel has adequate space on bulkheads to post certificates; certificates were held in binder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Documents posted
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2024
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; the EPIRB test required by paragraph (a) shall be logged or otherwise documented. Last documented EPIRB test was in March 2024, MI witnessed test and documented in log.
Action required: 10 - Deficiency Rectified
Resolved 30 September 2024
Resolution: Logged EPIRB test
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon)buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel had only two fire buckets on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2023
Resolution: A third fire bucket was put on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2023
Resolved
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The water light was permanently attached to the life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 17 October 2023
Resolution: Received photgraphic evidence to the correction of the deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 October 2023
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2023
Resolved 17 October 2023
Resolution: Received photgraphic evidence to the correction of the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 4 October 2023
Resolved
Except as provided in §§ 80.177 and 80.179, operation of transmitters of any ship station must be performed by a
person holding a commercial radio operator license or permit of the class required below. The operator is
responsible for the proper operation of the station. No crewmember has an FCC Operators Permit. 47 CFR 80.155
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 17 October 2023
Resolution: Received photgraphic evidence to the correction of the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 September 2022
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Port and stbd rudder post packing gland has loose bolt connections. 46 CFR 182.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 23 September 2022
Resolution: Gland tightened. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 September 2022
Resolved
Rails or equivalent protection shall be installed. Port rail stanchions (03 identified) are cracked.
46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 23 September 2022
Resolution: Rail stanchions welded. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
All vessels shall be provided with bilge pumps in accordance with table 182.25-10(a). Vessel did not have hand held pumps.
46 CFR 182.25-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 23 September 2022
Resolution: Hand pump provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
A vessel must be provided with a satisfactory arrangement for drainage any watertight compartment. High level alarm in E/R is not secured.
46 CFR 182-25-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 23 September 2022
Resolution: High level alarm mounted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screen of flame arresters. Fuel tank vent pipe bracket holding the flame screen is damaged.
46 CFR 182.20-30(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 23 September 2022
Resolution: Flame screen fixed. All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 July 2021
Resolved
Abandon ship and man overboard and fire fighting drills shall be logged for review and include the date on the drill and general description of the drill. MI went through vessel log for 2021 and found no drills logged. Vessel got underway and conducted satisfactory drills prior to the end of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 July 2021
Resolution: Vessel got underway and conducted satisfactory drills prior to the end of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 July 2021
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up to date charts. Charts were found to be out of date (paper and electronic). Vessel to provide up to date charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 11 August 2021
Resolution: Vessel submitted satisfactory evidence of obtaining new charts, all satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 10 July 2020
Resolved
The weather deck on a flush deck vessel must be watertight. Port side vent has a 3 inch crack on deck. Effect proper repairs.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel overheated the port engine while underway due to kelp and blew gasket resulting in water mixing with the oil. Vessel must make repairs and prove proper operation of the port engine prior to carrying passengers and/or cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2020
Resolved 10 July 2020
Resolution: Vessel proved proper operation of the port engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2020
Resolved
Fuel lines must be secured against excessive movement and vibration. Starboard engine fuel line bracket missing, other bracket is unserviceable. Provide bracket and effect proper repairs on unserviceable bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2020
Resolved
An exposed hazard such as rotating machinery, must be properly protected by a cover/ guard. Bilge pump coupling is exposed. Provide machinery guard/cover.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2020
Resolved
Each lifejacket kept in a stowage container must be readily available. Port side lifejacket storage space locking latch is broken. Remove and replace latch mechanism.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 March 2020
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard. Engine room port side missing light bulb, glass cover, and guard. Engine room starboard side lighting fixture missing protective guard. Effect proper repairs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 March 2020
Resolved
Each window and its means of attachment to the hull or deck house must be capable of withstanding the maximum load from a wave and wind conditions. Port side operating station window is cracked. Effect proper repairs.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2020
Resolved
Exhaust leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Engine room starboard side exhaust requires 2 hose clamps, only 1 installed. Port side exhaust missing bracket hardware. Effect proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2020
Resolved
Remote fuel shutoff stations must be marked in clear, legible letters 1 inch high. Found labeling to be missing. Provide proper markings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 March 2020
Resolved
Each vessel must be equipped with at least 2 operable portable battery lights. One of these lights must be located at the operating station and access to machinery space. MI found no portable lights on board, provide serviceable portable lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 27 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 March 2020
Resolved
All vessels must have navigation lights that are in compliance with applicable sections of navigational rules. MI found starboard navigational light to be inoperable. Effect proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2020
Resolved 10 July 2020
Resolution: Opened light fixture and re-seated light bulb.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 April 2019
Resolved
Hyro-static release for EPIRB is expired. Provide new hyro-static release. Vessel restricted to operations not more than 3 miles from land.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2019
Resolved 18 April 2019
Resolution: A new hydro was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2019
Resolved
Renew life ring retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 18 April 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 November 2016
Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT HULL EXAMINATION
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 15 November 2016
Resolution: Completed satisfactory hull examination. Credit for drydock given 15NOV16
Engineering › Bilge Water Management System › Valve
Issued 16 May 2016
Resolved
Install check valve in bilge suction pipe in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2016
Resolved 25 May 2016
Resolution: Verified new installation of check valve in the engine room fixed bilge piping, all satisfactory.
Electrical › Electric Generation Source (service) › Conductor
Issued 16 May 2016
Resolved
Properly connect all wiring for stbd mde battery charging system, minimize accidental contact w/ energized loose wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Vessel crew properly connected all wiring for stbd mde battery charging system.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 May 2016
Resolved
Replace in-kind fuel tank vent flame screen flange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Vessel crew replaced in-kind fuel tank vent flame screen flange.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 May 2016
Resolved
Make all penetrations in collision bkhd watertight
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Vessel crew made all penetrations in collision bkhd watertight through use of marine grade foam.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 May 2016
Resolved
Removed (01) kapok-type PFD with a ruptured flotation bladder. Vessel had more tahn enough PFD's onboard to satisfy COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Removed PFD from service.
Engineering › Fuel Oil Service System › Piping
Issued 16 May 2016
Resolved
Remove zipties and properly support fuel oil manifold pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Manifold pipe supported with metallic pipe support.