Records from 1984 to 1991. Most recent: inspection, 22 October 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
22 October 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1245262
11 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232254
5 November 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214322
29 October 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 490344
29 October 1990
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 923615
21 May 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899749
24 July 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 454587
1 September 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1039119
24 August 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 325253
28 July 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 324657
8 December 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 510292
8 December 1986
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1022796
22 October 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 447477
22 October 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 474385
22 October 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 992082
7 October 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 304949
7 October 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 990367
13 August 1984
Type not recorded
No type recorded · COTP NEW LONDON · USCG Northeast District (CGD-NE) · Activity 499219
Documentation
Issued 29 October 1990
Resolved
SUBMIT IMO CERTIFICATE OF FITNESS TO MSC FOR ACCEPTANCE FOR RENEWAL OF SUBCHAPTER O ENDORSEMENT. NO SUB O CARGOES MAY BE CARRIED.
Condition: Unknown
Due 29 November 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 May 1990
Resolved
REMOVE FLAMMABLES FROM FORWARD STORAGE LOCKER (FORECASTLE) OR INSTALL FIXEDFIRE EXTINGUISHING SYSTEM (SPACE USED AS PAINT LOCKER).
Condition: Unknown
Due 21 May 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 May 1990
Resolved
REPAIR EXCESSIVELY LEAKING PACKING GLAND ON THE MSD (MARINE SANITATION DEVICE) CIRCULATING PUMP.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Fire Fighting
Issued 21 May 1990
Resolved
REPAIR EXCESSIVELY LEAKING PACKING GLAND ON SHIP'S FIRE/SERVICE PUMP.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Fire Fighting
Issued 21 May 1990
Resolved
INSTALL TWO MISSING VALVE HANDLES FOR MAIN DECK, AMIDSHIPS PORT, HOSE STATIONS.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Deck/Cargo
Issued 21 May 1990
Resolved
PROVIDE TWO ADDITIONAL SETS OF PROTECTIVE GOGGLES PRIOR TO TRANSFERING CARGOES REQUIRING PROTECTIVE CLOTHING.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Deck/Cargo
Issued 21 May 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF CARGO OIL MONITOR'S OIL CONTENT METER (INOPERATIVE).
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Navigation
Issued 28 July 1988
Resolved
VSL DID NOT HAVE A CURRENT LIGHT LIST (VOL 1 ATLANTIC COAST OR BR ADM) AS REQUIRED BY 33 CFR 164.33 (A)(2)(II). LIGHT LIST WAS 1981 (B.A. VOL J) ED. WITH NO CORRECTIONS E.G. 13/88 DELETE TRACKING SYSTEM BUOY'S. VSL IS 3887 GROSS TONS. VSL TRANSITTED NARRAGANSETT BAY ON 28JUL88.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Deck/Cargo
Issued 28 July 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Deck/Cargo
Issued 28 July 1988
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE, MISSING INFORMATON AS REQUIRED BY 33 CFR 155.750 (A)(1)(I),(2)(III)),(3),(4),(5),(7),(8), AND (9). THIS WAS NOTED ON MSO PROVIDENCE TANKSHIP EXAM FORM FOR ASSISTING MARINE INSPECTORS DTD 28JUL88. TRANSFER OPERATION WAS NOT IN PROGRESS WHEN DISCREPANCY NOTED.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Navigation
Issued 28 July 1988
Resolved
VESSEL MISSING LOCAL CHART, (NOAA) 13218 OR FOREIGN EQUIVALENT AS REQUIRED BY 33 CFR 164.33 (A)(1)(I). THIS IS A MARINE CHART OF THE AREA TRANSITTED ON 28JUL88. VESSEL IS 3887 GROSS TONS.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Deck/Cargo
Issued 28 July 1988
Resolved
VSL DID NOT HAVE A MECHANICAL MEANS OF CLOSING EACH CONTAINMENT DRAIN AND DECK SCUPPER IN THE BUNKERING AREA AS REQUIRED BY 33 CFR 155.310 (A)(3). TRANSFER WAS NOT IN PROGRESS. VESSEL HAS OIL CAPACITY GREATER THAN 250 BARRELS.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Deck/Cargo
Issued 28 July 1988
Resolved
VSL CARGO DISCHARGE MANIFOLDS MISSING BLANK FLANGE COVERS. THE EXISTING FLANGE COVERS WERE NOT PROPERLY BOLTED IN PLACE, TO THE TRANSFER SYSTEM OTHERWISE NOT IN USE AS REQUIRED BY 33 CFR 156.120 (E). TRANSFER WAS NOT INPROGRESS WHEN DISCREPANCY WAS NOTED.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Navigation
Issued 28 July 1988
Resolved
VESSEL MISSING U.S. COAST PILOT (VOLUME 2) OR FOREIGN EQUIVALENT AS AS REQUIRED BY 33 CFR 164.33 (A)(2)(I). VSL IS 3887 GT. VSL TRANSITTED NARRAGANSETT BAY ON 28JUL88.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Deck/Cargo
Issued 22 October 1985
Resolved
INSTALL DRAIN PLUGS (MECHANICAL) IN ALL DISCHARGE CONTAINMENT BOXES.
Condition: Unknown
Due 22 October 1985
Resolved 22 October 1985
Navigation
Issued 7 October 1985
Resolved
VIOLATION OF 33 CFR 164.30 FOR OPERATING A VSL OF 1600 OR MORE GT WITHOUT ACURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROMTHE USCG LIGHT LIST (VOL.1)FOR THE AREA TRANSITED (CAPE HENRY, VA. TO BALTIMORE) AS REQUIRED BY 33 CFR 164.33(A)(2)(II).NO FOREIGN EQUIVALENT O/B
Condition: Unknown
Due 7 October 1985
Resolved 7 October 1985
Navigation
Issued 7 October 1985
Resolved
VIOLATION OF 33 CFR 164.30 FOR OPERATING A VSL OF 1600 OR MORE GT WITHOUT ACURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROMTHE U.S. COAST PILOT (VOL.3) FOR THE AREA TO BE TRANSITED (CAPE HENRY, VA. TO BALTIMORE) AS REQIRED BY 33 CFR 164.33 (A)(2)(I).
Condition: Unknown
Due 7 October 1985
Resolved 7 October 1985
Unknown
Issued 7 October 1985
Resolved
VSL'S PIPING TO STEAM SMOTHERING SYSTEM SIGNIFICANTLY WASTED. RENEW/REPLACE PRIOR TO DEPARTING NEXT US PORT OF CALL.
Condition: Unknown
Due 7 October 1985
Resolved 7 October 1985
Unknown
Issued 7 October 1985
Resolved
VSL US COAST PILOT VOL. 3 AND USCG LIGHT LIST VOL. 1 OUTDATED. PROVIDE CORRECTED COPIES PRIOR TO NEXT US PORT OF CALL.
Condition: Unknown
Due 7 October 1985
Resolved 7 October 1985