Records from 1982 to 2017. Most recent: inspection, 7 June 2017.
Inspection history · 80
7 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168209
13 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 5858216
13 April 2016
Security Breach
Type not classified · Activities Europe · Activity 5864402
9 March 2014
Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 4793748
13 September 2011
DAPI Audit · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 4061515
28 July 2011
Type not recorded
No type recorded · Activities Europe · Activity 4129558
10 November 2010
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 3892171
8 January 2010
Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · Activities Europe · Activity 3660763
9 March 2009
Type not recorded
No type recorded · Activities Europe · Activity 3430145
6 March 2009
Type not recorded
No type recorded · Activities Europe · Activity 3428529
6 March 2009
Type not recorded
No type recorded · Activities Europe · Activity 3428546
26 October 2008
Type not recorded
No type recorded · Activities Europe · Activity 3352674
29 August 2008
Damage Survey · Annual Inspection
Physical examination · Activities Europe · Activity 3302729
28 August 2008
Type not recorded
No type recorded · Activities Europe · Activity 3428541
28 July 2008
Administrative Inspection
Administrative · Activities Europe · Activity 3281999
22 July 2008
Type not recorded
No type recorded · Activities Europe · Activity 3428528
16 May 2008
Type not recorded
No type recorded · Activities Europe · Activity 3207984
28 February 2008
Type not recorded
No type recorded · Activities Europe · Activity 3417143
10 July 2007
Type not recorded
No type recorded · Activities Europe · Activity 2990343
4 July 2007
COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 2911499
17 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751338
4 August 2006
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2735790
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502048
13 August 2005
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2443728
28 February 2005
Type not recorded
No type recorded · Activities Europe · Activity 2300385
24 February 2005
Hull Examination
Physical examination · Activities Europe · Activity 2297452
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293951
29 January 2005
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Activities Europe · Activity 2181752
8 June 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2067237
5 March 2004
Deficiency Check
Physical examination · Activities Europe · Activity 2005127
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979659
27 August 2003
Annual Inspection
Physical examination · Activities Europe · Activity 1880549
5 June 2002
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1626524
27 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489623
5 April 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062418
9 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433771
21 April 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817252
2 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389004
24 February 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049144
21 January 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045851
26 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 50856
22 January 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393073
5 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 171646
11 March 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411624
15 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 787363
7 July 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368287
9 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093401
28 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385892
16 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082168
14 May 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1082553
4 April 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083566
14 March 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383186
7 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875183
26 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189288
13 July 1995
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456288
9 February 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456271
3 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175114
1 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214632
1 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214806
22 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1181467
23 May 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387547
8 December 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 665729
20 October 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5864
25 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358032
27 April 1992
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472482
25 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927293
28 March 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224754
26 April 1990
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914216
28 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887697
21 October 1988
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199618
11 April 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1194260
8 April 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009500
16 December 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1026034
25 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302380
5 April 1986
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306910
12 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290616
4 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1283903
5 June 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 975284
17 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968159
28 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279507
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 9 March 2014
Resolved
Lagging missing and crack repaired with epoxy which was not USCG approved
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 7 April 2014
Resolution: Rcvd email from vsl rep [name withheld] with proof that bellows repaired and lagging re-installed.
Communications › Radio Communications › Emergency Source of Power
Issued 9 March 2014
Resolved
Battery charger for the GMDSS batteries found inop
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 28 May 2014
Resolution: Rcvd email dated 27 May 2014 from [name withheld] that the charger has been installed and operates as intended.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2011
Resolved
The fire blanket int he galley was missing.
Due 14 October 2011
Resolved 21 September 2011
Lifesaving › Visual Distress Signals (General) › Condition
Issued 14 September 2011
Resolved
Provide a battery for the daylight signaling lamp on the bridge.
Due 14 October 2011
Resolved 14 September 2011
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 14 September 2011
Resolved
Provide a steel lined or steel paint locker NLT the next drydock which is 05 Jun 2012.
Due 5 June 2012
Resolved 16 May 2013
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 November 2008
Resolved
Prove proper operation of starboard shaft tach. Verify indications in the engineroom and pilothouse (fore and aft stations).
Due 14 January 2009
Resolved 10 August 2009
Resolution: Witnessed proper operation of the shaft tach in engine room and all stations on the pilot house.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 24 October 2008
Resolved
Prove proper operation and reliability of the entire Autocator pneumatic alarm system, include the local panels in the engineroom and pilothouse. Demonstrate proper operation of all temperature and pressure sensors iaw with approved test procedures. Replace/repair inoperative temp and press gauges on the engineroom autocator panels.
Due 24 November 2008
Resolved 14 November 2008
Electrical › Electric Generation Source (service) › Generator
Issued 24 October 2008
Resolved
Prove the proper load handling capabilities of the #2 SSDG (aft). The load is currently fluctuating when a heavy load is applied.
Due 24 November 2008
Resolved 14 November 2008
Stability › Watertight Integrity › General
Issued 24 October 2008
Resolved
Make port engine room emergency escape hatch watertight.
Due 24 November 2008
Resolved 14 November 2008
Fire Fighting › Fire Hoses › Condition
Issued 24 October 2008
Resolved
Provide three (UL 19) approved fire hoses.
Due 24 November 2008
Resolved 14 November 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 24 October 2008
Resolved
Walk in freezer motor controller door will not close properly.
Due 24 November 2008
Resolved 14 November 2008
Engineering › Compressed Air System (control) › Compressor
Issued 24 October 2008
Resolved
Inboard air compressor in e/r is not working in auto mode.
Due 24 November 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 October 2008
Resolved
Properly secure deck plates by stbd reduction gear.
Due 24 November 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 October 2008
Resolved
Install guards to cover the rotating machinery on both SSDG's.
Due 24 November 2008
Resolved 14 November 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 24 October 2008
Resolved
Blank off exposed area in the bottom of the 208v load center electrical box in the e/r.
Due 24 November 2008
Resolved 14 November 2008
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 24 October 2008
Resolved
Prove proper operation of the autocator fire detection panel.
Due 24 November 2008
Resolved 14 November 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 October 2008
Resolved
Prove proper operation of the OWS.
Due 24 November 2008
Resolved 14 November 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 October 2008
Resolved
Provide emergency/battery-powered lighting to port and stbd embarkation area on main deck.
Due 24 November 2008
Resolved 14 November 2008
Lifesaving › Lifebuoys › Not on Board
Issued 24 October 2008
Resolved
Install two approved lifebuoys (one with self igniting light) on forecastle deck to match fire control and safety plan. (Lifebouy approval series160.050 or 160.150)
Due 24 November 2008
Resolved 14 November 2008
Lifesaving › Lifebuoys › Approval
Issued 24 October 2008
Resolved
Replace two non-approved lifebuoys on aft main deck with USCG approved lifebuoys, approval series 160.050 or 160.150.
Due 24 November 2008
Resolved 14 November 2008
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 24 October 2008
Resolved
Provide one approved line throwing device.
Due 24 November 2008
Resolved 14 November 2008
Deck/Cargo › Mooring/Anchoring › Brake
Issued 24 October 2008
Resolved
Make repairs to starboard anchor brake assy. Brake slips when anchor is in hawsed position.
Due 24 November 2008
Resolved 14 November 2008
Deck/Cargo › Mooring/Anchoring › Swivel Link (anchor chain)
Issued 24 October 2008
Resolved
Make repairs to port anchor chain swivel. Anchor will not swivel during hawsing process.
Due 24 November 2008
Resolved 14 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 24 October 2008
Resolved
Provide UL/USCG approved fire extinguisher for rescue boat. (USCG approval series 162.028).
Due 24 November 2008
Resolved 14 November 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 October 2008
Resolved
Prove proper operation of mast head light.
Due 24 November 2008
Resolved 14 November 2008
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 18 July 2007
Resolved
Failure to comply with the requirements for vessel owners to pay fees before inspection or examination services are provided.
Action required: 705 - Other - as specified
Resolved 13 August 2007
Engineering › Diesel Engine (auxiliary) › Governor
Issued 4 July 2007
Resolved
Prove proper operation on the vessels aft ship service generator prior to sailing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2008
Resolution: Cleared on the Coast Guard behalf by ABS surveyor.
Navigation › Piloting/Steering › Gyro Compass
Issued 4 July 2007
Resolved
Prove proper operation of the vessels gyro.
Condition: Damaged By Earlier Event
Due 17 February 2008
Resolved 24 October 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 July 2007
Resolved
Prove proper operation of the vessels oily water separator. Retain all oily waste onboard and provide documentation for all oily waste discharges.
Condition: Improper/Lack of Maintenance
Due 17 February 2008
Resolved 14 November 2008
Navigation › Piloting/Steering › Azimuth
Issued 4 July 2007
Resolved
Cleared requirement to remain open until verified during the next inspection.
Ensure accuracy of the vessels rudder angle indicators. All rudder angle indicators shoud read similar within a few degrees.
Condition: Improper/Lack of Maintenance
Due 17 February 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 July 2007
Resolved
Cleared to remain open until verified during the next inspection.
Provide guards on all moving machinery. (Air Compressors in main engine space.)
Condition: Improper Installation
Due 17 February 2008
Resolved 14 November 2008
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 4 July 2007
Resolved
Cleared, to remain open until verified during next inspection.
Prove proper operation of the overspeeds on the fore and aft generators.
Condition: Improper/Lack of Maintenance
Due 17 February 2008
Resolved 14 November 2008
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 4 July 2007
Resolved
Cleared, to remain open until verified during next inspection.
Renew starter air supply hose.
Condition: Improper/Lack of Maintenance
Due 17 February 2008
Resolved 14 November 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 July 2007
Resolved
Update fire control plan and submit for approval
Condition: Improper/Lack of Maintenance
Due 17 February 2008
Resolved 14 November 2008
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 14 May 2007
Resolved
Prior to getting underway, provide a Safety management certificate for the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 May 2007
Resolved
Make proper repairs to wasted areas in the port potable water tank.
Action required: 705 - Other - as specified
Due 4 August 2007
Resolved 13 August 2007
Construction/Loadline › Structures › Trunk
Issued 14 May 2007
Resolved
Renew all wasted frames and piping in engine room escape trunks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2007
Resolved 13 August 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 May 2007
Resolved
Provide testing proceedures from the manufacturer for the oily water separator.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 4 July 2007
Electrical › Electric Generation Source (service) › Generator
Issued 14 May 2007
Resolved
Provide RPM gauge for the forward and aft ship service generator.
Action required: 705 - Other - as specified
Due 4 August 2007
Resolved 13 August 2007
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 14 May 2007
Resolved
Provide equipment and perform all automated test procedures IAW the vessel's approved automated test procedure manual. Provide a monthly report that all requirements are being satisfied and email to [email withheld] until further notice.
Action required: 705 - Other - as specified
Due 4 August 2007
Resolved 13 August 2007
Documentation › Logs/Records › Oil Record Book
Issued 14 May 2007
Resolved
Oil record book entries were not complete and 2 completed pages were not signed by Vessel Captain. All entries are to be IAW with instructions provided in the Oil Record Book.
Action required: 703 - Prior to bunkering operations
Resolved 13 August 2007
Construction/Loadline › Structures › Scuttle
Issued 4 August 2006
Resolved
MAKE REPAIRS ON THE PORT AND STARBOARD ENGINE ROOM EASCAPE TRUNK HATCH. Reported cleared with e-mail 14 Dec, confirm COI renewal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 4 August 2007
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 4 August 2006
Resolved
REPLACE DEFECTIVE TACHOMETER AND DEMONSTRATE PROPER OPERATION OF BOTH AUX GENERATOR OVERSPEED SHUTDOWN. Report cleared via E-mail 18 Oct 2006, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 4 August 2007
Construction/Loadline › Structures › Deck Plating
Issued 4 August 2006
Resolved
CROP AND RENEW WASTED FOUNDATION OF BOTH BILGE PUMPS.
Condition: Improper/Lack of Maintenance
Due 17 August 2006
Resolved 17 August 2006
Resolution: SIGHTED NEW FOUNDATION.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 August 2006
Resolved
MAKE REPAIRS TO EXHAUST LEAKS ON BOTH MDE.Report cleared via E-mail 18 Oct 2006, Item remains open until cleared by attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 4 August 2007
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 4 August 2006
Resolved
MAKE THE NECESSARY REPAIRS TO BOTH MDE LUBE OIL SYSTEM TO RECTIFY PROBLEM OF HIGH LUBE OIL TEMPERATURE AT HIGHER ENGINE SPEED. Reported cleared with e-mail 14 Dec, confirm COI renewal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 4 August 2007
Fire Fighting › Fire Main › Condition
Issued 4 August 2006
Resolved
CROP AND RENEW WASTED FOUNDATION OF THE FIRE PUMP. Report cleared via E-mail 18 Oct 2006, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 4 August 2007
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2006
Resolved
Vessel to complete a audit of the SMS for issuance of a SMC. 19 Oct received e-mail copy of a SMC issued under 33 CR not SOLAS, re-issue to be done granted 30 days extension.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 December 2006
Resolved 1 December 2006
Resolution: Received copy of SMC
Communications › Radio Communications › EPIRB
Issued 24 August 2005
Resolved
Vessel must install a Coast Guard approved EPIRB. This deficiency was added on August 24, 2005 and is not found on the hardcopy CG-835 dated August 14, 2005. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Sighted new EPIRB.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 August 2005
Resolved
Repair and prove proper operation of bilge alarms in Engineroom and steering gear. 30 minute soundings of all bilges are to be taken and logged in engineroom and steering flat every 30 minutes. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: SIGHTED LOG AND TEST ALARMS.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 August 2005
Resolved
Properly secure all engine room deck plates. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Inspected, Sat.
Lifesaving › Launching Appliances › Davit
Issued 13 August 2005
Resolved
Provide suitable rescue boat davit that can adequately launch rescue boat within 5 minutes. (Note: winch shall have a safety factor of 4.5 Max Working Load (MWL) MWL includes the total weight of the boat, personnel and boat equipment. Personnel should be calculated as three persons times 165 lbs each). * [name withheld] reported this item as corrected on February 14, 2006, must confirm. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Wittness test of Davit, Time was just under 7 minutes, but cleared def.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 August 2005
Resolved
Provide light covers for all lights in steering gear. Florescent light assembly to be provided with lamps. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Sighted covers.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 13 August 2005
Resolved
Provide and prove proper operation of tachometers for port main engine and both ship generators. Once installed, prove proper operation of over speed trips.
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 13 August 2005
Resolution: Not required in accordance with Subchapter "I." Deleted this item from the CG-835 delivered to the vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 August 2005
Resolved
Provide insulation where missing on port and starboard main engine exhaust. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Sighted new Insulation.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 August 2005
Resolved
Remove temporary container power supply cable from within port engineroom escape trunk. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Cable removed.
Accommodation/Occupational Safety › Sleeping Accommodations › People Per Room
Issued 13 August 2005
Resolved
Remove racks from rooms that contain more than four crew. No room shall accommodate more than 4 person's iaw 46 CFR 92.20. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Rack was removed.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 13 August 2005
Resolved
Properly mount oxygen and acetylene bottles on main deck. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Done, Sat.
Navigation › Piloting/Steering › Marine Charts
Issued 13 August 2005
Resolved
Obtain current charts, applicable light list and volume D of the admiralty list of lights and signals
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 17 August 2006
Resolution: Done, Sat.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 13 August 2005
Resolved
Prove proper operation of high temperature alarms on main engines and generators.
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 17 August 2006
Resolution: Test, Sat.
Engineering › Bilge Water Management System › Piping
Issued 13 August 2005
Resolved
Engine room bilges need to be cleaned. * [name withheld] reported this item as corrected on February 14, 2006. Marine Inspectors must confirm as cleared during the next examination. *
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 17 August 2006
Resolution: Test, sat.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 2 March 2005
Resolved
VESSEL MUST MAKE REPAIRS TO BOTH MAIN ENGINES. REPAIRS MUST BE TO MANUFACTURE'S SPECIFICATIONS AND TO THE SATISFACTION OF THE OCMI.
Due 1 June 2005
Resolved 14 August 2005
Personnel › Certificates/Documents/Licenses › STCW Certificate, Engineer Watch Rating
Issued 2 March 2005
Resolved
VESSEL MUST MAINTAIN A CONTINUOUS ENGINE ROOM WATCH UNTIL REPAIRS ARE COMPLETED TO BOTH MAIN ENGINES. THIS WILL REQUIRE A THREE WATCH SYSTEM IN LIEU A TWO WATCH SYSTEM. THE ENGINE ROOM WATCHES REQUIRE STCW CERTIFICATED PERSONNEL.
Due 1 June 2005
Resolved 14 August 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 2 March 2005
Resolved
DRAIN VALVES, INSTALLED TO THE MAIN ENGINES AIR BOXES, MUST BE OPENED AND ALLOWED TO DRAIN EVERY THREE HOURS. VALVES MUST BE CLOSED AFTER TO PREVENT ATOMIZED OIL FROM ENTERING THE ENGINE ROOM.
Due 1 June 2005
Resolved 14 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 29 January 2005
Resolved
Provide sufficient STCW certificated personnel possessing, at a minimum a STCW endorsement as Rating Forming Part of an Engineering Watch, establish a three watch engine room watch, and maintain a continuous watch in engine room while underway. E/R watch must maintain ventilation and promptly remove oil leakage.
Due 1 March 2005
Resolved 2 March 2005
Resolution: REISSUED
Construction/Loadline › Hull › Bottom Plating
Issued 29 January 2005
Resolved
Make satisfactory temporary repairs to bow thruster tunnel where it is leaking and implement monitoring plan as identified in Captain's proposal.
Due 1 March 2005
Resolved 2 March 2005
Resolution: REPAIRS COMPLETED
Construction/Loadline › Hull › Hull Plating
Issued 29 January 2005
Resolved
Make permanent repairs to bow thruster tunnel where it is leaking.
Due 9 March 2005
Resolved 2 March 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 29 January 2005
Resolved
Overhaul both main engines and return to manufacturer's specifications particularly in regards to crankcase oil pressure and daily lube oil usage.
Due 9 March 2005
Resolved 2 March 2005
Resolution: REISSUED
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2005
Resolved
Prove proper operation of engine room automation package, including fire detection system. Vessel must maintain live watch in engine room until this is completed).
Due 9 March 2005
Resolved 2 March 2005
Resolution: TEST COMPLETED
Lifesaving › Launching Appliances › Winch Brake
Issued 29 January 2005
Resolved
Prove proper operation of fast rescue craft (FRC) davit brake.
Due 9 March 2005
Resolved 1 March 2005
Lifesaving › Launching Appliances › Falls
Issued 29 January 2005
Resolved
End for end FRC falls and conduct 110% weight test (((number of persons allowed in FRC X 165 pounds) + weight of FRC) X 110).
Due 9 March 2005
Resolved 1 March 2005
Lifesaving › Rescue Boat › Propulsion Engine
Issued 29 January 2005
Resolved
Change and fill fuel in FRC.
Due 9 March 2005
Resolved 1 March 2005
Lifesaving › Rescue Boat › Markings
Issued 29 January 2005
Resolved
Replace retro reflective tape on FRC.
Due 9 March 2005
Resolved 1 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 29 January 2005
Resolved
Hydro test or replace CO2 bottles for both paint lockers.
Due 9 March 2005
Resolved 27 February 2005
Resolution: replaced
Communications › Radio Communications › EPIRB
Issued 29 January 2005
Resolved
Replace EPIRB.
Due 9 March 2005
Resolved 28 February 2005
Communications › Audible Communications › Horn/Whistle
Issued 29 January 2005
Resolved
Prove proper operation of ship's horn (from pilot house control station).
Due 9 March 2005
Resolved 28 February 2005
Stability › Watertight Integrity › General
Issued 29 January 2005
Resolved
Replace missing dogs on engine room emergency escapes, adjust all dogs, and prove proper sealing of same.
Due 9 March 2005
Resolved 2 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 29 January 2005
Resolved
Make permanent repairs in way of vessel internals as identified in written CG 835.
Due 9 March 2005
Resolved 2 March 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 29 January 2005
Resolved
Update new hire program to include SOPEP training.
Due 29 March 2005
Resolved 28 February 2005
Pollution Prevention/Response › Prevention Equipment
Issued 27 August 2003
Resolved
Install proper piping and prove proper operation of OWS. At the time of inspection there was no piping attached after the OWS recirculation to waste oil tank. OWS was not operational in inspected condition. Master stated oily waste is current held in slop tank and pumped to shore side facility. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 23 September 2003
Resolved 23 September 2003
Resolution: Corrected as required.
Engineering › Bilge Water Management System
Issued 27 August 2003
Resolved
Replace engine room bilge piping (marked center e/r) in way of soft patch. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 23 September 2003
Resolved 16 September 2003
Resolution: Crop and renew repairs conducted on effected bilge piping.
Operations/Management › Lifesaving
Issued 27 August 2003
Resolved
Maintain records of lifesaving equipment maintenance. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Condition: Improper/Lack of Maintenance
Due 23 September 2003
Resolved 27 August 2003
Resolution: Issued in error
Engineering › Bilge Water Management System
Issued 24 August 2003
Resolved
Remove excess fuel and lube oil from engineroom bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2003
Resolved 26 August 2003
Resolution: Bilges pumped dry.
Engineering
Issued 24 August 2003
Resolved
Clean oily residue from stack space in engine room. In current condition a fire hazard exists.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2003
Resolved 26 August 2003
Resolution: Oily residue removed, stack space cleaned.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 24 August 2003
Resolved
Replace flame screens for "EMD" oil, goose neck vent pipe. Vent is located stbd side in engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2003
Resolved 26 August 2003
Resolution: Flame screen replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2003
Resolved
Remove all twist on wire connectors and replace with crimp type connectors.
Condition: Improper Installation
Due 23 September 2003
Resolved 26 August 2003
Resolution: Wire connectors replaced as required.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 August 2003
Resolved
Prove proper operation of engine room automation, test machinery alarms, shutdowns and heat detectors as per USCG approved procedures.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2003
Resolved 26 August 2003
Resolution: Automation tested and proved operational by third party.
Deck/Cargo › Holds/Tanks
Issued 24 August 2003
Resolved
Test relief valves for all "p" tanks (dry bulk tanks) LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2003
Resolved 9 March 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 August 2003
Resolved
Adjust port and stbd engine room emergency escape hatches to allow easy egress. And adjust cargo compressor room WTD for proper seal.
Condition: Improper/Lack of Maintenance
Due 24 August 2003
Resolved 26 August 2003
Resolution: Emergency hatches and WTD adjusted for easy access and egress and chalk tested.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 August 2003
Resolved
Provide proof of annual drug and alcohol testing program.
Condition: Unknown
Due 23 September 2003
Resolved 28 February 2005
Operations/Management › Equipment Service/Testing
Issued 24 August 2003
Resolved
Provide proof of shore side maintenance for GMDSS.
Due 23 September 2003
Resolved 26 August 2003
Resolution: Shore side maintenance agreement and POC provided.
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 August 2003
Resolved
Replace gaskets for emergency escape hatches in engine room with proper rubber gasket material.
Condition: Improper/Lack of Maintenance
Due 23 September 2003
Resolved 26 August 2003
Resolution: Proper gasket material installed.
Operations/Management › Pollution
Issued 24 August 2003
Resolved
Maintain record of waste oil discharge to shore facility in oil record book. LEGACY COMPONENT DESC: Ballast Water Management
Condition: Improper/Lack of Maintenance
Due 23 September 2003
Resolved 9 March 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 August 2003
Resolved
Hydro test all cargo and fuel transfer hoses and provide proof of satisfactory tests. LEGACY COMPONENT DESC: Transfer Hose
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2003
Resolved 14 September 2003
Resolution: All hoses tested by chief eng and witnessed by vessel Master. Fax received for verification.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 June 2002
Resolved
REPAIR LIGHT WIRES IN RUDDER ROOM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 June 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2002
Resolved
REMOVE EXTENTION CORDS USED AS PERMANENT WIRING UNDER PILOT HOUSE CONSOLE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 5 June 2002
Lifesaving › Rescue Boat
Issued 5 June 2002
Resolved
REPAIR RESCUE BOAT HANDHELD SPOPLIGHT. LEGACY COMPONENT DESC: HANDHELD SPOTLIGHT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2002
Resolved 6 June 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 5 June 2002
Resolved
PROVIDE AND POST FUEL OIL TRANSFER PROCEDURES AT THE TRANSFER OPERATING STATION. LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2002
Resolved 6 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 February 2002
Resolved
PRIOR TO SAILING REPAIR BRIDGE MAIN ENGINE AND BOWTHRUSTER ALARM PANELS (BULBS) LEGACY COMPONENT DESC: ALARM PANEL
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 27 February 2002
Resolved
RENEW PORT LIFERAFT HYDROSTATIC RELEASE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 February 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 27 February 2002
Resolved
REPAIR ENGINEERS STATEROOM SOUND POWERED PHONE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 February 2002
Resolved
REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING
Condition: Placed in Improper Service
Due 27 February 2002
Resolved 27 February 2002
Electrical › Lighting (emergency)
Issued 27 February 2002
Resolved
ADD 01 ADDITIONAL EMERGENCY LIGHT TO ILLUMINATE THE MAIN DECK EXIT WATERTIGHT DOOR LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 27 March 2002
Resolved 5 June 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 February 2002
Resolved
SERVICE FIRE EXTINGUISHER #15 PRIOR TO SAILING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Engineering › Steering Gear System › Pin
Issued 27 February 2002
Resolved
PRIOR TO SAILING INSTALL RETAINING PINS IN PORT STEERING RAM
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 27 February 2002
Resolved
REPAIR RUDDER ROOM SOUND POWERED PHONE
Condition: Improper/Lack of Maintenance
Due 27 February 2002
Resolved 27 February 2002
Communications › Internal Communications System
Issued 27 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE ENGINE ROOM SPP SYSTEM CALL INDICATOR (VISUAL/AUDIBLE) UNDER EMERGENCY POWER LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper Installation
Due 27 March 2002
Resolved 5 June 2002
Engineering › Fuel Oil Service System › Hose
Issued 27 February 2002
Resolved
INSTALL CHAFING GEAR ON FUEL OIL AND LUBE OIL HOSES AS DISCUSSED
Condition: Improper Installation
Due 27 February 2002
Resolved 27 February 2002
Engineering › Lubricating Oil Service System › Hose
Issued 27 February 2002
Resolved
REPLACE PORT MDE L/O PURIFIER HOSE PRIOR TO SAILING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 February 2002
Resolved
PROPERLY SECURE SPLICED WIRE OUTSIDE JUNCTION BOX IN STBD ENG ROOM EMERG ESCAPE.
Condition: Improper/Lack of Maintenance
Due 27 February 2002
Resolved 27 February 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 February 2002
Resolved
PROPERLY REPAIR AFT ENGINE ROOM 100V ELECTRICAL PANEL COVER. (HINGE AND LOCK)
Condition: Improper/Lack of Maintenance
Due 27 February 2002
Resolved 27 February 2002
Engineering › Bilge Water Management System › Manifold
Issued 27 February 2002
Resolved
INSTALL LABEL ON 03 BILGE MANIFOLD VALVES
Condition: Improper Installation
Due 27 February 2002
Resolved 27 February 2002
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 27 February 2002
Resolved
DOUBLE NUT STBD SHAFT PACKING RETAINING SEAL
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2002
Resolved 27 February 2002
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 27 February 2002
Resolved
CLEAN LINE THROWING GUN BARREL
Condition: Improper/Lack of Maintenance
Due 27 February 2002
Resolved 27 February 2002
Construction/Loadline
Issued 9 January 2001
Resolved
PROVER PROPER OPERATION OF THE OILY WATER SEPARATOR SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Lifesaving
Issued 2 March 2000
Resolved
PROVIDE APPROVED FIRE SAFETY PLAN. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 April 2000
Resolved 24 April 2001
Engineering
Issued 2 March 2000
Resolved
DEMONSTRATE PROPER OPERATION OF INSTALLED BRIDGE REMOTE ENGINE SHUTDOWNS. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Lifesaving
Issued 24 February 2000
Resolved
PROVIDE APPROVED PLANS FOR RESCUE BOAT DAVIT INSTALLATION.
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Electrical
Issued 22 January 1999
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH GENERATOR OVERSPEEDS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Lifesaving
Issued 22 January 1999
Resolved
PROVIDE APPROVED RESCUE BOAT IAW CURRENT DISTRICT 8 POLICY TITLED "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12 NOV 98, TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Engineering
Issued 14 March 1996
Resolved
PROVE PROPER OPERATION OF ALL AUTOMATION IN E/R TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Deck/Cargo
Issued 14 March 1996
Resolved
PROVIDE THREE (3) NEW RELIEF VALVES FOR P TANKS. BENCH TEST ALL FIVE (5) AGAIN.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996
Resolved
MAKE REPAIRS TO THE FOLLOWING FUEL CUTOFF SYSTEM PNEUMATIC VALVES: #2 STARBOARD FUEL SUCTION, #1 SHIPS FUEL, #1 PORT DAY TANK. VALVES SHALL BE MANUALLY CLOSED & PADLOCKED & MASTER SHALL KEEP CUSTODY OF KEYS UNTIL VALVES ARE REPAIRED TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Fire Fighting
Issued 14 March 1996
Resolved
REPACK LEAKING SEAL ON FIRE PUMP.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Deck/Cargo
Issued 14 March 1996
Resolved
REPAIR HYDRAULIC GEAR LEAK ON PORT ANCHOR.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Documentation
Issued 13 July 1995
Resolved
PROVIDE ON BOARD A VALID PERMANENT STABILITY LETTER. VESSEL MAY OPERATE USING TEMPORARY STABILITY LETTER DATED 11JUL95 UNTIL IT IS SUPERSEDED.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Documentation
Issued 13 July 1995
Resolved
PROVIDE ON BOARD A NEW LOAD LINE CERTIFICATE THAT REFERENCES NEXT-ISSUED_x001C_ PERMANENT STABILITY LETTER. EXISTING LOAD LINE CERTIFICATE SHALL BE CON- SIDERED VALID UNTIL THAT TIME.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Documentation
Issued 23 May 1994
Resolved
PROVIDE ON BOARD THE VESSEL OIL TRANSFER PROCEDURES WHICH COMPLY WITH AND INCLUDE ALL REQUIRED INFORMATION FOR FUEL, LIQUID MUD AND OILY WASTE TRANSFER SYSTEMS AS REQUIRED BY 33 CFR 155.750.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Documentation
Issued 23 May 1994
Resolved
PROVIDE ONBOARD SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Electrical
Issued 5 April 1986
Resolved
MAKE PERMANENT REPAIRS TO THE AUTOMATED MONITORING SYSTEMS OF THE BRIDGE PRIOR TO 19APR86. UNTIL SUCH REPAIRS ARE MADE, THE ENGINEROOM IS TO BE MANNED CONTINUOUSLY WHILE THE VESSEL IS UNDERWAY.
Condition: Unknown
Due 5 April 1986
Resolved 5 April 1986
Fire Fighting
Issued 12 April 1985
Resolved
PROVIDE UPDATED SAFETY PLAN FOR CG APPROVAL
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Electrical
Issued 5 June 1984
Resolved
REPAIR ON SS GENERARTORS OVERSPEED TRIPS.
Condition: Unknown
Due 5 June 1984
Resolved 5 June 1984
Electrical
Issued 5 June 1984
Resolved
INSTALL IN SS GENERATORS FUEL PRESSURE SWITCHES.
Condition: Unknown
Due 5 June 1984
Resolved 5 June 1984
Unknown
Issued 28 April 1982
Resolved
CONDUCT REQUIRED FIRE AND BOAT DRILLS.
Condition: Unknown
Due 28 April 1982
Resolved 28 April 1982