Records from 1982 to 1987. Most recent: inspection, 10 July 1987.
Documentation record
Registered dimensions (L × B × D)181.0 ft × 38.2 ft × 15.4 ft
Registered tonnagegross 281 / net 190
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · PORT ARTHUR, TX, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsRegistry
DocumentationInvalid
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it281 - Regulatory (Subpart C or D), Gross Ton
190 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
10 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322509
5 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000525
26 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969470
9 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272510
5 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967009
1 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963475
Construction/Loadline
Issued 5 October 1982
Resolved
PERMANENTLY MOUNT HEAT SENSOR UNIT ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
REMOVE ALL DEAD-ENDED WIRES ON NON-FUNCTIONING CONTROLS AND SWITCHES.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
REPLACE ALL RETRO-FITTED NON-MARINE CABLES WITH AS BUILT QUALITY AND TYPE CABLE OR CABLE MEETING 46CFR111.60-1 AS APPLICABLE.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Unknown
Issued 5 October 1982
Resolved
PROVIDE GUARD OVER WIRE ROPE REEL ON AIR TUGGER ON PORT SIDE TO PROTECT OPERATOR.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
MAKE ALL ELECTRICAL SPLICES IN JUNCTION BOXES OR MECHANICAL CONNECTIONS.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Unknown
Issued 5 October 1982
Resolved
PROVIDE CORRECT SIZE RELIEF VALVE ON DISCHARGE SIDE OF FIRE PUMP (FOR FIRE MONITOR) AND TEST.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Unknown
Issued 5 October 1982
Resolved
PROVIDE LAGGING ON EXPOSED GENERATOR EXHAUST PIPE IN STBD. STACK ESCAPE TRUNK.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
REPAIR PORT FORCED DRAFT FAN IN ENGINE ROOM.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Construction/Loadline
Issued 5 October 1982
Resolved
PROPERLY SEAL OPENINGS IN WATER TIGHT BULKHEADS IN PORT ESCAPE TRUNK.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Lifesaving
Issued 5 October 1982
Resolved
PROVIDE CG APPROVED PARACHUTE FLARES (12 REQUIRED).
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
PROVIDE QUICK ACTING RELEASE FOR FIXED CO2 SYSTEM AND MARK FORWARD PAINT LOCKER (POST OPERATION INSTURCTIONS AT RELEASE).
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Unknown
Issued 5 October 1982
Resolved
PROVIDE PROPER SIZED RELIEF VALVES FOR (2) CLUTCH AIR RECEIVERS AND (1) AIRRECEIVER FOR DIESEL WINCH AND PERFORM OPERATIONAL TEST OF SAME.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
PROVIDE REPLACEMENT HOSE AND VALVE UNITS FOR B-V CO2 UNITS IN ENGINE ROOM.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Navigation
Issued 5 October 1982
Resolved
REPOSTION FORWARD RANGE LIGHT OR OBTAIN CERTIFICATE OF ALTERNATIVE COM- PLIANCE. (COLREGS ANNEX I PARA. 3A)
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Navigation
Issued 5 October 1982
Resolved
PROVIDE CIRCUIT WITH PILOT HOUSE OUTLET FOR "ALDIS" LAMP.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
PROVIDE DRIP SHIELD AND MECHANICAL PROTECTION FOR STEP-DOWN (IIOV) TRANS- FORMER OVER TOP MAIN SWITCH BOARD.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982
Electrical
Issued 5 October 1982
Resolved
PROVIDE GUARDS ON OPEN TERMINAL STRIPS AND DEAD COVERS ON OPEN JUNCTION BOXES.
Condition: Unknown
Due 5 October 1982
Resolved 5 October 1982