Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
14 September 2025
PSC A · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8227177
19 September 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7794003
8 September 2023
PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7787630
14 September 2019
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6803774
27 September 2018
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6550081
23 September 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6546420
9 September 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6263033
22 March 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6099992
31 January 2016
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5805812
24 January 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5842747
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2025
Resolved
The construction of all doors and door frames in ``A'' class
divisions, with the means of securing them when closed,
shall provide resistance to fire as well as to the passage of
smoke and flame, as far as practicable, equivalent to that of
the bulkheads in which the doors are situated. Such doors
and door frames shall be constructed of steel or other
equivalent material. PSCO observed FSD/10/VI/007,
FSD/10/VI/008, FSD/08/IV/015, FSD/06/VI/003, unable
to fully close.
74 SOLAS 97 II-2/30.2
16 abc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2025
Resolved 22 September 2025
Resolution: Vessel has provided documentation and photos as evidence of the doors being able to close.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 September 2025
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in
this part, the minimum fire integrity of all bulkheads and
decks shall be as prescribed in tables 26.1 to 26.4. Where,
due to any particular structural arrangements in the ship,
difficulty is experienced in determining from the tables the
minimum fire integrity value of any divisions, such values
shall be determined to the satisfaction of the Administration. PSCO observed 01 A-60 door in the computer room, and 04 B-15 doors were left open reducing the overall fire intergrity.
74 SOLAS 97 II-2/26.1
16 abc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2025
Resolved 22 September 2025
Resolution: Vessel has provided documentation and photos as evidence of the doors being able to close.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 September 2025
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Spaces are classified according to their fire risk as shown in categories (1) to (14). A/C machinery space on port side deck 8, MVZ 3 is a category (10) space where storage of combustibles is prohibited. PSCO observed storage of cardboard boxes and other combustible materials in A/C
space deck 5 Port side as well as deck 7 STBD atrium.
74 SOLAS 97 II-2/26.2.2
16 abc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2025
Resolved 22 September 2025
Resolution: Vessel has provided documentation and photos as evidence of the space being cleared of all combustible materials.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 September 2025
Resolved
Stairway enclosures in accommodation and service
spaces shall have direct access from the corridors and be of
a sufficient area to prevent congestion, having in view the
number of persons likely to use them in an emergency.
Within the perimeter of such stairway enclosures, only
public toilets, lockers of non-combustible material
providing storage for non-hazardous safety equipment and open information counters are permitted. Only public
spaces, corridors, public toilets, special category spaces,
other escape stairways required by regulation 28.1.5 and
external area are permitted to have direct access to these
stairway enclosures. PSCO observed multiple chairs,
wheelchairs and waste receptacles located in category 2
spaces.
74 SOLAS 97 II-2/29.2
16 abc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2025
Resolved 22 September 2025
Resolution: Vessel has provided documentation and photos as evidence of the space being cleared of wheelchairs and waste receptacles.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 15 September 2023
Resolved
Oil filtering equipment shall be provided with alarm arrangements to indiciate when this level cannot be maintained. PSC Team was unable to verify operation of oil filtering equipment and alarm due to detected high levels of H2S in the space.
MARPOL Annex I/14.7
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 September 2023
Resolution: Received LR Class report attesting to the proper operation of the oily water separator and normal atmospheric conditions in the OWS space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 September 2023
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The propeller shafting shall be so arranged that the propeller can be disengaged from the engine. Provision shall be made for ahead and astern propulsion of the lifeboat. Port side tender #8 experienced a grounding incident which bent the rudder and required temporary repairs to the hull by the crew. Flag issued a dispensation assigned the tender as a lifeboat, however, class has not confirmed repairs or attested that the manueverability and integrity of the lifeboat are adequate.
74 SOLAS 20 III/34
LSA Code 4.4.6.5
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2023
Resolved 18 September 2023
Resolution: No.8 tender boat now lowered into the water and maneuvered under supervision of the surveyor with satisfactory results. The cracks iwo of the Stbd shaft bracket found not penetrating and repaired with proper epoxy by crew.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 September 2023
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions, the sections enclosed by "B" class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installations, the fire-extinguishing appliances, means of access to different compartments, decks, etc. and the ventilating system, including particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fans serving each section.
Two fire-doors on deck 04 were found intentionally removed - the fire control plan has not been updated to reflect this change.
74 SOLAS 20 II-2/15.2.4.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 September 2023
Resolution: Received LR Class report stating the identifed doors are not fire doors and the fire control plan has been updated to reflect the changes.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2019
Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. The hoisting chain for the horizon grill fire shutter was off its track, rendering the fire shutter inoperable.
74 SOLAS (97) II-2/21
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2019
Resolved 16 September 2019
Resolution: 10c - deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 September 2019
Resolved
Each MBR of the crew shall be given INST which shall include OPS and use of fire-extinguishing appliances. Cook was unfamiliar w/how to operate fire shutter at his normal cooking station.
74 SOLAS (97) III/18.4.2.4
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2019
Resolved 16 September 2019
Resolution: 10c - deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2019
Resolved
All life-saving appliances prescribed in this part shall be fitted w/retro-reflective material where it will assist in detection and IAW the recommendations of the organization. 03 lifebuoys found w/worn and unserviceable retro tape.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2019
Resolved 16 September 2019
Resolution: 10c - deficiency rectified.