Records from 1985 to 2026. Most recent: inspection, 4 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 69
4 June 2026
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8324404
9 June 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8112674
30 September 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8008077
10 June 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7899763
5 June 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7700142
29 March 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7659338
17 October 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7576804
13 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7464606
15 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7226759
4 June 2021
Type not recorded
No type recorded · Station Merrimac River · USCG Northeast District (CGD-NE) · Activity 7216019
26 August 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7042511
9 June 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6966934
2 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6732192
26 June 2019
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6725235
27 August 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6523983
11 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6441796
6 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6165963
5 January 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066371
4 October 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6014888
6 June 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5913988
16 June 2014
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4890880
7 May 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4305379
9 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4205138
17 November 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3894088
1 May 2009
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3465122
15 April 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3453402
5 May 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3199329
8 May 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2925459
21 March 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2891931
2 May 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2638394
3 May 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2348002
28 March 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2320958
25 May 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2077429
19 May 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1796418
2 April 2003
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1768188
14 September 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1682722
3 June 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1626717
16 May 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1617495
15 June 2001
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1462965
8 May 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435033
24 April 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1421851
5 May 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807261
1 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126407
13 April 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123000
9 May 1997
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101763
17 June 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085665
13 May 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1084004
22 April 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1081719
14 June 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187416
7 June 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1186270
25 April 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 865024
2 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858007
18 April 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1167676
28 May 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1145149
24 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952090
22 May 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 953677
22 May 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1254577
15 May 1991
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214125
29 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1217258
11 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1235056
23 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907215
19 June 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1043989
10 April 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1338223
7 April 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1347202
6 May 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887516
5 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1197382
22 May 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1293186
21 November 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1303503
8 May 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 979562
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 June 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI observed one lifefloat had cracks in the outer shell, exposing the inner bouyant core.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2024
Resolution: Operator provided objective evidence in the form of photographs showing that adequate repairs had been made to the lifefloat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 June 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. No flame screen installed in fuel vent pipe.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2022
Resolution: Flame screen added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Life jackets on stern box were not easily seperated from Adult & Child life jackets. Storage locations are not appropriately marked and seperated.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2022
Resolution: Storage locations marked and seperated.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 June 2021
Resolved
For a life float approved under approval series 160.027, a buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. One of the two buoyant apparatus present on board the vessel was found with a manufacture date after March 11, 1996. Remove buoyant apparatus and replace with life float approved under approval series 160.027.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 13 June 2022
Resolution: Buoyant apparatus was replaced with an approved Life Float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2019
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Light for fish hold bilge pump not operational. Provide functioning light
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 July 2019
Resolution: Bilge pump indication lights replaced and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 July 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables. Out of date pubs, No inland nav rules onboard. No paper charts. Provide all required publications and charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 July 2019
Resolution: All required nautical pubs and charts procured and onboard vessel.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 July 2019
Resolved
Fire fighting / man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 2 July 2019
Resolution: Drills conducted during inspection properly logged.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 July 2019
Resolved
The master of the vessel shall ensure that Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No log of EPIRB testing. Log monthly EPIRB test in vessel log.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 2 July 2019
Resolution: Consudted training on proper EPIRB test procedure and logged test.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2018
Resolved
TJT-01 Not to operate with passengers until fire suppression system serviced and inspected, 46CFR181-420 prior to 25JUN18.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 21 June 2018
Resolution: Received photo evidence of servicing receipt.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 June 2018
Resolved
TJT-02 Have onboard applicable emergency instructions and posted at operating station by 25JUN18; 46CFR185.510.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 21 June 2018
Resolution: Received photo evidence of emergency placard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2017
Resolved
Provide proof of enrollment in drug and alcohol testing program for all current employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 18 July 2017
Resolution: Vessel rep provided proof of enrollment for all current employees.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 June 2017
Resolved
Provide proof of pre-employment drug testing for all current employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 18 July 2017
Resolution: Vessel rep provided proof of pre-employment testing for all current employees.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 October 2016
Resolved
Install valve on both electric submersible pump overboard discharges.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 5 January 2017
Resolution: Vessel rep installed positive action valve on both pumps.
Stability › Freeing Ports › General
Issued 4 October 2016
Resolved
Make all freeing ports to operate freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 5 January 2017
Resolution: Freeing ports operate freely.
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 30 PERSONS (PASSENGERS AND CREW) 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 2 April 2012
Resolution: Issued new stability letter and amended COI.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 1 May 2009
Resolved
Mast Head light was extinguished
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 1 May 2009
Resolution: Owner replaced bulb
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2007
Resolved
Fixed fire suppression system engine shut down inoperable when tested, found leads to engine shut down solenoid wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Resolution: Wires renewed and shut down system tested.
Deck/Cargo › Holds/Tanks › Hatch
Issued 3 May 2005
Resolved
Properly repair all watertight hatches to ensure proper operation.
Due 26 May 2005
Resolved 16 May 2005
Engineering › Bilge Water Management System
Issued 25 May 2004
Resolved
Bilge system was inopperable at the time of the inspection
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2004
Lifesaving › Buoyant Apparatus
Issued 25 May 2004
Resolved
Provide two paddles for each BA.
Due 15 June 2004
Resolved 28 May 2004
Stability › Watertight Integrity
Issued 25 May 2004
Resolved
Ensure all deck skuttles are operating properly.
Due 15 June 2004
Resolved 28 May 2004
Fire Fighting › Fire Main
Issued 25 May 2004
Resolved
Properly label fire buckets
Due 15 June 2004
Resolved 28 May 2004
Lifesaving
Issued 25 May 2004
Resolved
Properly attach all lights to the life ring and BAs.
Due 15 June 2004
Resolved 28 May 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 May 2003
Resolved
provide 12 additional adult Type 1PFDs for a total of 30. Until complete, vessel is limited to 18 total adults.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 22 May 2003
Resolution: Received fax copy of invoice for 12new PFDs.
Communications › Radio Communications
Issued 19 May 2003
Resolved
Renew hydrostatic release for EPIRB. Until complete, vessel may not carry passengers beyond three (3) miles from the coastline. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 3 June 2003
Resolution: [name withheld] examined satisfactory hydro release.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 May 2003
Resolved
Provide annual servicing for fixed and portable fire extinguishers. LEGACY COMPONENT DESC: Quantity of Gas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 3 June 2003
Resolution: [name withheld] witnessed satisfactory testing of fixedand portable extinguishers.
Navigation › Piloting/Steering
Issued 3 June 2002
Resolved
Provide a current copy of the Coast Pilot and Light List. LEGACY COMPONENT DESC: US Coast Pilot
Due 17 June 2002
Resolved 21 June 2002
Communications › Radio Communications
Issued 3 June 2002
Resolved
Provide an emergency broadcast placard.
Due 17 June 2002
Resolved 21 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002
Resolved
Replace the hose going from the engine to the exhaust manifold starboard side.
Due 17 June 2002
Resolved 21 June 2002
Construction/Loadline
Issued 15 June 2001
Resolved
PROVIDE AUDIBLE HIGH LEVEL BILGE ALARMS PRIOR TO PASSENGERS.
Condition: Unknown
Due 15 June 2001
Resolved 12 July 2001
Fire Fighting
Issued 15 June 2001
Resolved
SERVICE FIXED AND PORTABLE FIRE FIGHTING EXTINGUISHERS.
Condition: Unknown
Due 1 July 2001
Resolved 12 July 2001
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE PROPER WEAK LINK ON LIFE FLOAT.
Condition: Unknown
Due 1 July 2001
Resolved 12 July 2001
Lifesaving
Issued 15 June 2001
Resolved
ATTACH WATERLIGHTS TO LIFE RING, LIFE FLOAT, AND BUOYANT APPARATUS.
Condition: Unknown
Due 1 July 2001
Resolved 12 July 2001
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE FIRST AID KIT.
Condition: Unknown
Due 1 July 2001
Resolved 12 July 2001
Navigation
Issued 8 May 2000
Resolved
Running lights inop. Prove proper operation of running lights.
Condition: Unknown
Due 21 May 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 May 2000
Resolved
Weigh fixed gas extinguisher located in the engine room. Document and log the weight
Condition: Unknown
Due 21 May 2000
Resolved 8 June 2000
Lifesaving
Issued 8 May 2000
Resolved
Retro reflective tape deteriorated on life float. Renew missing/deteriorated retro reflective tape.
Condition: Unknown
Due 21 May 2000
Resolved 8 June 2000
Lifesaving
Issued 8 May 2000
Resolved
Life float paddles split and broken. Renew paddles.
Condition: Unknown
Due 21 May 2000
Resolved 8 June 2000
Lifesaving
Issued 8 May 2000
Resolved
Properly mark life preserver storage areas and mark the number of life preservers stored therein in at least 1 inch high letters.
Condition: Unknown
Due 21 May 2000
Resolved 8 June 2000
Lifesaving
Issued 9 May 1997
Resolved
PROVIDE DOCUMENTATION AS TO THE PURCHASE AND INSTALLATION OF THE NEWLY ORDERED 406 MHZ EPIRB.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Documentation
Issued 9 May 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS CONTAINEDIN 46 CFR PART 16.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Electrical
Issued 13 May 1996
Resolved
PROPERLY DEAD END THE FOUR LOOSE WIRES IN THE ENGINE COMPARTMENT, FORWARD BULKHEAD, STARBOARD SIDE.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Accommodation/Occupational Safety
Issued 13 May 1996
Resolved
PROVIDE AND POST A PROPER WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Documentation
Issued 13 May 1996
Resolved
PROVIDE A VALID FCC OPERATORS PERMIT.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Engineering
Issued 13 May 1996
Resolved
RENEW THE MDE RAW WATER COOLING LINE.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Construction/Loadline
Issued 22 May 1992
Resolved
MAIN DECK RENEWED AFT OF CONSOLE
Condition: Unknown
Due 9 July 1992
Resolved 9 July 1992
Construction/Loadline
Issued 22 May 1992
Resolved
RENEWED ENTIRE WELL DECK PLYWOOD AND UNDERDECK SUPPORT MEMBERS.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Fire Fighting
Issued 22 May 1992
Resolved
CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD FIRE & ABANDON SHIP PRIOR TO CARRYING PASSENGERS. DRILLS ARE TO BE CONDUCTED BY THE MASTER WITH ALL PERSONNEL, INCLUDING REQUIRED DECKHANDS NORMALLY ASSIGNED TO THE VESSEL. A LETTER OR COPY OF THE LOG ENTRY IS TO BE SENT TO [name withheld].
Condition: Unknown
Due 10 June 1992
Resolved 24 July 1992
Lifesaving
Issued 10 April 1989
Resolved
REMOVE TEMPORARY REPAIR TO BUOYANT APPARATUS AND MAKE PERMANENT REPAIR.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Navigation
Issued 10 April 1989
Resolved
RENEW HYDRAULIC HOSE CONNECTION TO STEERING GEAR.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Engineering
Issued 10 April 1989
Resolved
PROVIDE FUEL SHUT OFF VALVE ON FUEL TANK.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989