ERICA LEE

ERICA LEE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in June 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 4 June 2026.

Built
1981
Last inspected
4 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC5414
Flag
UNITED STATES
Maury page id
psix-53741

Documentation record

Registered dimensions (L × B × D)42.0 ft × 13.2 ft × 6.2 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRUNO & STILLMAN INC · NEWINGTON, NH, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEWBURY, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 27 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

4 June 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8324404
9 June 2025 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8112674
30 September 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8008077
10 June 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7899763
5 June 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7700142
29 March 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7659338
17 October 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7576804
13 June 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7464606
15 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7226759
4 June 2021 Type not recorded
No type recorded · Station Merrimac River · USCG Northeast District (CGD-NE) · Activity 7216019
26 August 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7042511
9 June 2020 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6966934
2 July 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6732192
26 June 2019 Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6725235
27 August 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6523983
11 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6441796
6 June 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6165963
5 January 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066371
4 October 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6014888
6 June 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5913988

Deficiency record · 14

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 June 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI observed one lifefloat had cracks in the outer shell, exposing the inner bouyant core.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2024
Resolution: Operator provided objective evidence in the form of photographs showing that adequate repairs had been made to the lifefloat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 June 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. No flame screen installed in fuel vent pipe.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2022
Resolution: Flame screen added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Life jackets on stern box were not easily seperated from Adult & Child life jackets. Storage locations are not appropriately marked and seperated.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2022
Resolution: Storage locations marked and seperated.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 June 2021 Resolved
For a life float approved under approval series 160.027, a buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. One of the two buoyant apparatus present on board the vessel was found with a manufacture date after March 11, 1996. Remove buoyant apparatus and replace with life float approved under approval series 160.027.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 13 June 2022
Resolution: Buoyant apparatus was replaced with an approved Life Float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Light for fish hold bilge pump not operational. Provide functioning light
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 July 2019
Resolution: Bilge pump indication lights replaced and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 July 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables. Out of date pubs, No inland nav rules onboard. No paper charts. Provide all required publications and charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 July 2019
Resolution: All required nautical pubs and charts procured and onboard vessel.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 July 2019 Resolved
Fire fighting / man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 2 July 2019
Resolution: Drills conducted during inspection properly logged.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 July 2019 Resolved
The master of the vessel shall ensure that Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No log of EPIRB testing. Log monthly EPIRB test in vessel log.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 2 July 2019
Resolution: Consudted training on proper EPIRB test procedure and logged test.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2018 Resolved
TJT-01 Not to operate with passengers until fire suppression system serviced and inspected, 46CFR181-420 prior to 25JUN18.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 21 June 2018
Resolution: Received photo evidence of servicing receipt.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 June 2018 Resolved
TJT-02 Have onboard applicable emergency instructions and posted at operating station by 25JUN18; 46CFR185.510.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 21 June 2018
Resolution: Received photo evidence of emergency placard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2017 Resolved
Provide proof of enrollment in drug and alcohol testing program for all current employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 18 July 2017
Resolution: Vessel rep provided proof of enrollment for all current employees.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 June 2017 Resolved
Provide proof of pre-employment drug testing for all current employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 18 July 2017
Resolution: Vessel rep provided proof of pre-employment testing for all current employees.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 October 2016 Resolved
Install valve on both electric submersible pump overboard discharges.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 5 January 2017
Resolution: Vessel rep installed positive action valve on both pumps.
Stability › Freeing Ports › General
Issued 4 October 2016 Resolved
Make all freeing ports to operate freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 5 January 2017
Resolution: Freeing ports operate freely.