Records from 1986 to 2000. Most recent: operational control imposed, 29 September 2000.
Inspection history · 63
29 September 2000
Port Security Assessment
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 558150
20 April 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 461818
8 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426140
15 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424646
15 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 789477
22 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421674
14 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421537
29 August 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 419680
7 August 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 456899
13 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 453518
20 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 461788
30 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 441220
4 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412482
2 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412251
15 December 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1128830
3 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410576
10 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 397950
10 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1098882
21 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391363
25 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384046
25 October 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1184128
9 September 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 360718
21 July 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 501922
13 April 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1147761
11 March 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 357147
11 March 1993
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 833603
27 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 455487
10 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 352100
28 April 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 650113
16 April 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 650112
7 April 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 460534
10 March 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 452031
10 March 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 947706
18 August 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1353245
16 July 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 525825
6 May 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1224850
8 March 1991
Deficiency Check · Certificate of Compliance
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 919295
28 July 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457026
30 April 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 510626
11 December 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 334269
11 December 1989
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921533
21 July 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 506881
21 July 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1210231
19 May 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 498750
17 May 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 895992
13 April 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1198293
15 November 1988
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1202664
30 July 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 523909
25 June 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1036612
16 April 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 458674
15 April 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 893354
23 February 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 525587
26 January 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1014581
19 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 520428
14 August 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1338794
24 April 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 477411
24 April 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 534161
15 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1022437
19 March 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 444404
19 March 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1326115
14 November 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 312666
24 October 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 489712
24 October 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1010332
Documentation
Issued 29 September 2000
No resolution recorded
Prior to entry into U. S. waters, provide evidence that all non- conformities that led to the recommendation by RINA for the revocation of the Document of Compliance have been satisfactorily addressed and the vessel is in complaince with the ISM Code.
Condition: Unknown
Due 1 June 2001 — due date passed with no resolution recorded
Lifesaving
Issued 15 January 1999
Resolved
PROVIDE DOCUMENTATION PROVING THAT PORTABLE RADIOS ARE INTRINSICALLY SAFE. PRIOR TO NEXT U.S. OFF-LOADING
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Engineering
Issued 15 January 1999
Resolved
REPLACE/REPAIR OILY WATER SEPARATOR; NOTED WASTED BOTTOMS TO SEPARATION CHAMBERS, HOLED TRANSFER LINE BETWEEN CHAMBERS 2&3,EXPOSED ELECTRICAL CONDUIT, ALARM PERFORMED UNSAT TEST, FILTERS UNSAT. CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Fire Fighting
Issued 15 January 1999
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN TO FIRE HYDRANT FORWARD PORT SIDE. HAS SOFT PATCH. CORRECT TO SATISFACTION OF CLASS PRIOR TO 29JAN99.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Lifesaving
Issued 15 January 1999
Resolved
DEMONSTRATE CALIBRATION OF PORTABLE EXPLOSIVE GAS METERS PRIOR TO NEXT U.S.PORT OFF-LOADING
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Deck/Cargo
Issued 22 October 1998
Resolved
CONDUCT PROPER OPERATION OF FIXED O2 ANALYZER TO THE SATISFACTION OF CLASS SOCIETY. PROVIDE COPY OF SURVEYOR'S REPORT TO USCG OCMI.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Deck/Cargo
Issued 14 October 1998
Resolved
IGS SYSTEM IN-OP_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Deck/Cargo
Issued 29 August 1998
Resolved
DEMONSTRATE TO THE SATISFACTION OF CLASS SOCIETY THAT IGS SYSTEM CAN PRODUCE AT LEAST 5% OXYGEN CONCENTRATION. DOCUMENTATION TO BE PROVIDED BY CLASS SOCIETY ATTESTING PROPER OPERATION OF SYSTEM.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Deck/Cargo
Issued 29 August 1998
Resolved
PROVIDE OIL DISCHARGE CONTAINMENT OF AT LEAST 42 US GLS, UNDER OR AROUND EACH FUEL OIL AND BULK LUBE OIL TANK VENTS, OVERFLOW AND FILL PIPE. INSTALLATION TO BE CONDUCTED BY NEXT DRY DOCK BUT NO LATER THAN 31 DEC 98, TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 14 January 1999
Resolved 29 January 1999
Deck/Cargo
Issued 29 August 1998
Resolved
REPAIR IGS SYSTEM FUEL PUMP TO THE SATISFACTION OF CLASS SOCIETY. DOCUMENTATION TO BE PROVIDED BY CLASS SOCIETY ATTESTING TO THE PROPER OPERATION OF FUEL PUMP.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Deck/Cargo
Issued 29 August 1998
Resolved
DEMONSTRATE TO THE SATISFACTION OF CLASS SOCIETY THE PROPER CALIBRATION FORZERO GAS AND SPAN GAS. CLASS SOCIETY TO PROVIDE DOCUMENTATION ATTESTING TOPROPER OPERATION OF SYSTEM.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Fire Fighting
Issued 3 December 1997
Resolved
REPLACE MISSING DOGS/VENT COVER ABOVE C02 DOOR PORT SIDE AFT AND ALL VENTS ON SECOND DECK AFT AND THROUHGOUT THE SHIP. (IILC 66 ANNEX 1/19). CORRECT PRIOR TO 15JAN98.
Condition: Unknown
Due 31 January 1998
Resolved 2 February 1998
Electrical
Issued 3 December 1997
Resolved
INSTALL MISSING LIGHT COVERS THROUGHOUT MACHINERY SPACES. (SOLAS 60 REG. II/26(a). REPAIR/INSTALL PRIOR TO 15JAN98) VESSEL CLEARED DEFICIENCY.
Condition: Unknown
Due 3 March 1998
Resolved 4 February 1998
Fire Fighting
Issued 3 December 1997
Resolved
REPLACE MISSING DOGS ON AFTSTERN ESCAPE HATCH. (ILLC 66 ANNEX 1/19). CORRECT PRIOR TO 15JAN98.
Condition: Unknown
Due 31 January 1998
Resolved 2 February 1998
Fire Fighting
Issued 3 December 1997
Resolved
PROVIDE SERVICING REPORT FOR DRY CHEMICAL SYSTEM PRIOR TO CONDUCTING CARGO OPERATIONS. PROVIDE LOCAL CG INSPECTOR WITH CLASS SURVEYOR'S REPORT. (IMO CODE FOR THE CONSTRUCTION AND EQUIPMENT OF SHIPS CARRYING LIQUIFIED GASES_x001C_ IN BULK, CHAPTER XI, PARAGRAPH 11.4.
Condition: Unknown
Due 15 December 1997
Resolved 12 January 1998
Electrical
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, REPLACE PROTECTIVE GLOBE MISSING FROM LIGHT FIXTURE IN STARBOARD SIDE OF ELECTRIC MOTOR ROOM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. IGC REG 10.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Lifesaving
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, SERVICE BOTH LIFERAFTS AT A MANUFACTURER APPROVED SERVICING FACILITY. PROIDE COPY OF SERVICING REPORT/CERTIFICATES TO LOCAL COAST GUARD. SOLAS 74/78 CHAP III REG. 19.8.1
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Lifesaving
Issued 10 December 1996
Resolved
REPAIR BROKEN GRAB LINE THROUGHOUT LIFEBOATS.
Condition: Unknown
Due 12 December 1996
Resolved 13 December 1996
Deck/Cargo
Issued 10 December 1996
Resolved
REPAIR QUICK CLOSING VALVES ON #2 STARBOARD MANIFOLD LIQUID LINE AND #1 STARBOARD DOME LIQUID LINE. VALVES NOT FULLY CLOSING.
Condition: Unknown
Due 12 December 1996
Resolved 13 December 1996
Lifesaving
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, HAVE SCBA'S EXPERTLY SERVICED. PROVIDE LOCAL COAST GUARD WITH COPY OF SERVICING REPORT. IGC REG 14.2.6.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Lifesaving
Issued 10 December 1996
Resolved
PATCH/REPAIR SMALL HOLES IN PORT AND STARBOARD LIFEBOATS TO SATISFY BOATS AIR SUPPORT SYSTEM.
Condition: Unknown
Due 12 December 1996
Resolved 13 December 1996
Accommodation/Occupational Safety
Issued 10 December 1996
Resolved
PROVIDE 2 LOWER TIERS OF CHAINS AT PORT AND STARBOARD GANGWAY.
Condition: Unknown
Due 12 December 1996
Resolved 13 December 1996
Deck/Cargo
Issued 10 December 1996
Resolved
REPAIR INERT GAS GENERATOR O2 ANALYZER, CALIBRATE, DEMONSTRATE ALL FUNCTIONS AND ALARMS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD PRIOR TO NEXT U.S. PORT. IGC REG 9.4 THRU 9.5.4.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Deck/Cargo
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE MEANS OF TESTING CARGO VACCUM PROTECTION SYSTEM. DEMONSTRATE PROPER OPERATION TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. IGC 8.4.1 & 8.4.4.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Deck/Cargo
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE PROPER SPAN GAS FOR GAS DETECTION SYSTEM, DETERMINE SOURCE/CAUSE OF UNIT TRIPPING OFF LINE AT 100% LEL. CALIBRATE &DEMONSTRATE PROPER OPERATION & ALARMS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. IGC REG 19.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Lifesaving
Issued 10 December 1996
Resolved
PROVIDE PROPER FENDER (SKATE) FOR PORT LIFE BOAT.
Condition: Unknown
Due 12 December 1996
Resolved 13 December 1996
Accommodation/Occupational Safety
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, INSTALL MISSING RAILS ON PORT AND STBD AFT FREEINGPORTS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. ILLC 66. REG 24 (6).
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Electrical
Issued 10 December 1996
Resolved
PRIOR TO NEXT U.S. PORT, REPAIR ELECTRICAL CABLES DISCONNECTED AND PROTURDING INTO WALKWAY IN ELECTRIC MOTOR ROOM FROM UNDERNEATH #2 BOOSTER PUMP MOTOR CONTROL TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. IGC REG 10.
Condition: Unknown
Due 12 December 1996
Resolved 10 January 1997
Fire Fighting
Issued 25 October 1995
Resolved
REPLACE HOSE ON FIRE EXTINGUISHER IN ENGINEROOM BY GENERATORS.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Electrical
Issued 25 October 1995
Resolved
REPAIR EMERGENCY LIGHTS IN STEERING COMPARTMENT AND COMPARTMENT ABOVE THE STEERING FLAT.
Condition: Unknown
Due 31 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 25 October 1995
Resolved
REPAINT VESSEL'S NAME ON THE BOW OF VESSEL'S HULL.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Lifesaving
Issued 25 October 1995
Resolved
DEMONSTRATE PROPER OPERATION OF AIR DRYING SYSTEM FOR VESSEL'S VOID SPACE.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 25 October 1995
Resolved
REPLACE MISSING DOG ON WTD TO PAINT LOCKER.
Condition: Unknown
Due 26 October 1995
Resolved 2 November 1995
Fire Fighting
Issued 25 October 1995
Resolved
DEMONSTRATE PROPER OPERATION OF DECK SPRAY SYSTEM TO COAST GUARD INSPECTOR,PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 26 October 1995
Resolved 25 October 1995
Construction/Loadline
Issued 25 October 1995
Resolved
REPAIR WTD TO FOWARD STORES, HAS HOLES IN DOOR FROM NAME PLATE.
Condition: Unknown
Due 26 October 1995
Resolved 2 November 1995
Documentation
Issued 25 October 1995
Resolved
PROVIDE ONBOARD MEDICAL CERTIFICATES FOR CREW THAT IS APPROVED BY FLAG STATE.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Fire Fighting
Issued 25 October 1995
Resolved
PROVIDE FLAG STATE APPROVAL FOR AN APPROPRIATE FIRE FIGHTING SYSTEM IN THE PAINT LOCKER.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Lifesaving
Issued 11 March 1993
Resolved
PROVIDE PROPER MARKING OF EMERGENCY SHOWER/EYE-WASH STATION.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 8 March 1991
Resolved
At next U.S. port, gas free and make available for Coast Guard internal examination a ballast tank in the vessel's midbody.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Deck/Cargo
Issued 8 March 1991
Resolved
Demonstrate proper operation of the high level and overfill alarms and controls prior to loading cargo.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Unknown
Issued 26 January 1988
Resolved
PRIOR TO CARRYING CARGOES IN U.S. PORTS REQUIRING INERTING, DEMONSTRATE SATISFACTORY OPERATION OF INERT GAS GENERATOR SYSTEM TO THE SATISFACTION OF THE COGINZANT OCMI.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Unknown
Issued 26 January 1988
Resolved
PRIOR TO ENTRY INTO U.S. PORT REMOVE PAINT FROM FACE OF PLUGS ON ALL FUSIBLE ELEMENTS LOCATED IN WAY OF CARGO TANK DOMES AND LOADING MANIFOLDS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Navigation
Issued 24 October 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Navigation
Issued 24 October 1986
Resolved
VSL DID NOT HAVE C.G. LIGHT LIST OR SIMILAR FOREIGN PUB. AVAILABLE A VIOLATION 33 CFR 164.33(A)(2)(II)
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Documentation
Issued 24 October 1986
Resolved
VSL DID NOT HAVE STEERING GEAR INSTRUCTIONS AND BLOCK DIAGRAM A VIOLATION OF 33 CFR 164.35(K)
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Documentation
Issued 24 October 1986
Resolved
VSL DID NOT HAVE A DESIGNATION PRESON IN CHARGE OF OIL TRANSFER A VIOLATION OF 33 CFR 155.700
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Documentation
Issued 24 October 1986
Resolved
OIL TRANSFER PROCEDURES DID NOT COTAIN ALL THE INFORMATION AS REQUIRED BY 33 CFR 155.750(A)(1),750(A)(2)AND 750(A)(2)(III)
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Documentation
Issued 24 October 1986
Resolved
VSL HAD NO RECORD OF TESTING OF THE FUEL TRANSFER SYSTEMS A VIOLATION OF 33 CFR 155.820
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986