DOROTHEA SCHULTE is a 1981 tank ship. The Coast Guard has recorded 27 inspections since 1986, most recently in August 2003, along with 18 deficiencies and 2 operational controls.
Records from 1986 to 2003. Most recent: operational control imposed, 21 August 2003.
- Built
- 1981
- Last inspected
- 21 August 2003
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8002664 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VSPU5
53755
Flag
ISLE OF MAN
—
Maury page id
psix-53755
Inspections, by type
…with no type recorded13
Years with a record
9 calendar years (1986–2003)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4884 - Convention (Subpart B), Gross Ton
4884 - Simplified, Gross Ton
1465 - Simplified, Net Ton
1465 - Convention (Subpart B), Net Ton
8335 - Displacement, Ton
6118 - Dead Weight, Metric Ton
4884 - Simplified, Gross Ton
1465 - Simplified, Net Ton
1465 - Convention (Subpart B), Net Ton
8335 - Displacement, Ton
6118 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
21 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1884357
2 May 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1785305
11 March 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1755985
7 March 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1754241
25 February 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1750481
27 January 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1740794
12 January 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1729125
14 December 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1718995
23 October 2002
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1695088
10 August 2002
Administrative Inspection · Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1659309
15 March 2002
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1494171
14 March 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1494131
12 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294664
10 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292640
3 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289449
3 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1064738
9 October 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 396010
22 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379824
22 June 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1189856
2 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351098
10 April 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1262160
2 September 1990
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 929173
9 September 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1043843
2 September 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 470889
2 September 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1040975
1 September 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1038803
17 November 1986
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020255
Deficiency record · 18
Documentation › Certificates/Documents
Issued 15 March 2002
Resolved
Invalid Subchapter 'O' Endorsement (SOE); 46 CFR 154.22 ; Provide current Certificate of Fitness to USCG Marine Safety Center for review/approval and receive valid SOE.
Deck/Cargo
Issued 15 March 2002
Resolved
Both Motor Room Airlock doors not self-closing; Gas Carrier Code 3.6.2; Provide same to satisfaction of Certificate of Fitness issuing authority.
Deck/Cargo
Issued 15 March 2002
Resolved
Both Foc'sle Airlock doors not self-closing; Gas Carrier Code 3.6.2; Provide same to satisfaction of Certificate of Fitness issuing authority.
Documentation
Issued 3 May 2001
Resolved
PROVIDE UPDATED LOADLINE CERTIFICATE THAT MATCHES PERMANENT PLIMSOL MARK ONVESSEL. (ILLC ANNEX I/9)
Engineering
Issued 3 May 2001
Resolved
M/E COOLING PUMP NO. 1 OUTLET PIPE HAS TEMPORARY SOFT PATCH. PERMANENTLY REPAIR TO SATISFACTION OF CLASS NLT 17 MAY 2001. (SOLAS 74A I/11)
Fire Fighting
Issued 22 June 1995
Resolved
CLEAN NOZZLES ON STBS SIDE MANIFOLD AND AROUND MOTOR/COMPRESSOR DECK HOUSE FOR WATER WASH DOWN SYSTEM.
Deck/Cargo
Issued 22 June 1995
Resolved
DEMONSTRATE HIGH O2 ALARM ON INERT GAS PLANT. PROVIDE CLASS SOCIETY REPORT TO U.S. COAST GUARD.
Deck/Cargo
Issued 22 June 1995
Resolved
REPLACE ALL FUEL OIL VENT FLAME SCREENS ON PORT & STBD SIDE. PROVIDE CLASS SOCIETY REPORT TO U.S. COAST GUARD.
Navigation
Issued 10 April 1992
Resolved
POST A TABLE OF SPEEDS AT WHICH THE BOW THRUSTER IS EFFECTIVE FOR NORMAL AND BALLAST CONDITIONS PRIOR TO RETURN TO U.S. WATERS.
Deck/Cargo
Issued 10 April 1992
Resolved
PROVE PROPER OPERATION OF IGS EQUIPMENT PRIOR TO LOADING CARGOES WHICH REQUIRE INERTING IN U.S. WATERS.
Deck/Cargo
Issued 10 April 1992
Resolved
RENEW FLAME SCREENS ON OIL TANK VENTS LOCATED AROUND SUPERSTRUCTURE PRIOR TO RETURN TO U.S. WATERS.
Navigation
Issued 10 April 1992
Resolved
OBTAIN COPIES OF NOTICE TO MARINERS AND UPDATE U.S. CHARTS PRIOR TO RETURN TO U.S. WATERS.
Navigation
Issued 10 April 1992
Resolved
UPDATE MANEUVERING INFORMATION POSTED ON THE BRIDGE WITH HALF SHIP SPEED TURNING CIRCLE DIAGRAM AND DISTANCE TO STOP PRIOR TO RETURN TO U.S. WATERS.
Navigation
Issued 2 September 1990
Resolved
OBTAIN BLOCK DIAGRAM AND SYSTEM OPERATING INSTRUCTIONS FOR STEERING GEAR SYSTEM AND POST ON BRIDGE AND STEERING GEAR ROOM.
Deck/Cargo
Issued 2 September 1990
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM PRIOR TO LOADING CARGOES REQUIREING INERTING.
Navigation
Issued 2 September 1990
Resolved
OBTAIN CURRENT COPIES OF U.S. COAST PILOT AND TIDAL CURRENT TABLES.
Deck/Cargo
Issued 2 September 1988
Resolved
DEMONSTRATE PROPER OPERATION OF IGS TO USCG MARINE INSPECTOR AT NEXT US PORT AFTER 26SEP88.
Unknown
Issued 17 November 1986
Resolved
PRIOR TO 30NOV86, PROVIDE ONBOARD CURRENT COPIES OF THE FOLLOWING PUBLICATIONS: A) 46CFR1-40; B) 46CFR140-155; C) 33CFR1-199; D) C.G. COAST PILOT (AREA TRANSITED); E) LIGHT LIST (AREA TRANSITED).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.