Records from 2016 to 2021. Most recent: inspection, 7 June 2021.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
8 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 8
7 June 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7153541
16 March 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7190898
19 March 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7005591
25 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718329
21 March 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6643419
26 February 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6361968
7 March 2017
COI Inspection · Simplified Stability Test · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097795
8 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6036199
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 March 2020
Resolved
Prior to carrying passengers crop fractured hull back to good metal and install insert to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2020
Resolved 16 March 2021
Resolution: Owner inserted affected area. Installation witnessed by MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 March 2020
Resolved
Prior to carrying passengers drill stop crack and weld closed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2020
Resolved 16 March 2021
Resolution: Owner inserted affected area. Installation witnessed by MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 March 2019
Resolved
Prior to carrying passengers, drill stop and repair crack located at starboard rear quarter to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2019
Resolved 25 April 2019
Resolution: Inspected weld repair. The Owner drill stopped both ends,ground the crack to decent metal and ran a fillet weld up the seam. The weld was them buffed down to the thickness of the original metal and painted, all sat. Def DC01 Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 March 2019
Resolved
Install retro reflective tape on life buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2019
Resolved 25 April 2019
Resolution: Retro reflective tape applied to ring buoy, all sat. Def DC02 Cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2019
Resolved
Prior to carrying passengers ensure high water bilge alarm is working properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2019
Resolved 25 April 2019
Resolution: Witnessed installation of new high water bilge alarm. Functioned properly, all sat. Def DC03 cleared.
Engineering › Bilge Water Management System › Not Operational
Issued 12 April 2018
Resolved
Repair or replace the automatic float switch for the installed bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 9 May 2018
Resolution: Owner replaced float switch due to faulty wiring; conducted satisfactory operational test of the float switch.
Operations/Management › Passenger Operations › Safety Orientation
Issued 12 April 2018
Resolved
Post life-jacket and emergency check-off procedures in a conspicuous location visible to the passengers carried aboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 9 May 2018
Resolution: Owner laminated and posted copies of both the life-jacket donning and the emergency check-off procedures.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2018
Resolved
Repair or replace the bilge high-level alarm in the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 9 May 2018
Resolution: Vessel owner repaired the existing high level alarm/float switch and proved the proper operation of the alarm.