Records from 1984 to 2001. Most recent: inspection, 29 August 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
29 August 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 292995
29 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1072627
13 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281148
13 November 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 472436
18 August 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 431784
5 August 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 431590
5 August 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1111857
21 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421854
21 October 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808811
16 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410886
11 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 401451
24 June 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 392720
24 June 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1090283
24 June 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1243836
16 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1182684
4 May 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 377961
29 August 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 369730
29 August 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 865643
4 August 1993
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 842895
24 July 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457108
13 October 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 949573
2 October 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354225
2 October 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 952737
10 July 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 950698
28 April 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 959449
18 December 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 485114
25 May 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1235140
30 September 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463569
30 May 1988
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200637
5 January 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1007695
22 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 441842
3 May 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308456
27 September 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 467588
Lifesaving
Issued 5 August 1999
Resolved
RENEW STBD MIDSHIPS GRATING PLATFORM FOR COMMON CARGO LINE IAW SOLAS 60/CHAP I/REG 11 PRIOR TO 05SEP99._x001C_ _x001C_
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Fire Fighting
Issued 5 August 1999
Resolved
REPAIR FWD ENGINE ROOM/POOP DECK FIRE DOORS, PORT ENGINE ROOM CONTROL ROOM FIRE DOOR, PORT MAIN DECK ENGINE ROOM ENTERANCE FIRE DOOR AND ADJACENT ACCOMMODATION SPACE FIRE DOOR IAW SOLAS 60/CHAP II/REG 38 PRIOR TO 05SEP99.
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Fire Fighting
Issued 21 October 1998
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP PRIOR TO NEXT SCHEDULED COASTGUARD BOARDING. PUMP APPEARED TO OPERATE PROPERLY BUT VESSEL WAS IN LIGHT SHIP CONDITION. SOLAS 60 11/56
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998
Resolved
REPAIR THE WASTED CONTAINMENT ABOUT THE VENT TO #3 FOT ON THE MIDSHIPS WX DECK PRIOR TO NEXT US PORT. 33 CFR 155.320
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998
Resolved
REPAIR WASTED FOAM LINE ON THE HYDRANT LOCATED AFT OF THE PORT CARGO MANIFOLD PRIOR TO NEXT U.S. PORT. SOLAS 60 II/56
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 21 October 1998
Resolved
PROVIDE AN ELECTRICAL MAT BEHIND THE MAIN SWITCHBOARD PRIOR TO NEXT U.S. PORT. SOLAS 60 II/27
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998
Resolved
REPAIR ALL EXHAUST LEAKS ON THE MAIN ENGINE EXHAUST LINE PRIOR TO RETURN TOA U.S. PORT. SOLAS 60 I/11
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998
Resolved
REPAIR THE BROKEN HYDRANT ON THE STERN OF THE VESSEL (CRACKED ABOUT FITTINGBUT STILL OPERATIONAL) PRIOR TO RETURN TO A U.S. PORT. SOLAS 60 II/56
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998
Resolved
REPAIR ALL WASTED VENT CLOSURES ON THE ACCOMODATION VENTS PRIOR TO RETURN TO A U.S. PORT. A VARIETY OF VENTS HAVE THE COAMING SECTIONS WASTED AWAY. ICLL 66 11/19
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998
Resolved
REPLACE ALL MISSING EXHAUST LAGGING ON THE DIESEL GENERATOR ENGINES PRIOR_x001C_ TO RETURN TO A U.S. PORT. SOLAS 60 I/11_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998
Resolved
REPAIR TANGLED SAFETY VALVE PULL CABLES ON THE AUXILIARY BOILER PRIOR TO NEXT U.S. PORT CALL. SOLAS 60 I/11
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998
Resolved
REPAIR THE HOLES IN THE MACHINERY SPACE FIRE DOORS AND ADJUST TO PROPERLY CLOSE TIGHTLY PRIOR TO NEXT U.S. PORT. SOLAS 60 II/54
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Navigation
Issued 21 October 1998
Resolved
INSTALL AN AUTOPILOT ALARM AS SPECIFIED IN 33CFR 157.440. VESSEL HAS BEEN GRANTED A TEMPORARY EQUIVALENCY UNTIL 20DEC98.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998
Resolved
MOVE PAINTS FROM DECK STORES TO THE APPROVED PAINT LOCKER PRIOR TO RETURN TO A U.S. PORT. SOLAS 74 AMD II-2/18.7
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 21 October 1998
Resolved
REPAIR THE EXCESSIVE HYDRAULIC LEAKS ON ANCHOR WINDLASS AND CRANE WINCHES PRIOR TO RETURN TO A US PORT. 33CFR 151.10(B)
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 21 October 1998
Resolved
REPAIR THE WASTED FOUNDATION ON THE FORWARD PART OF THE PORT ANCHOR WINDLASS PRIOR TO RETURN TO A U.S. PORT. SOLAS 60 I/11
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 16 December 1997
Resolved
Replace missing light cages in cargo pump room. BCH 3.5 and SOLAS 60 R/I.11
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Deck/Cargo
Issued 16 December 1997
Resolved
Show proper operation of cargo pump room's port ventilation system. BCH III 3.1.2 and Solas 60 R/I.11
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Documentation
Issued 16 September 1995
Resolved
Submit IMO Certificate of Fitness to Commandant (G-MSC) for review and reissue of Subchapter O Endorsement prior to carriage of certain dangerous bulk cargoes in U.S. waters.
Condition: Unknown
Due 16 September 1995
Resolved 16 September 1995
Engineering
Issued 24 July 1993
Resolved
Make permanent repairs to piping for for reduction gear heat exchanger.
Condition: Unknown
Due 24 July 1993
Resolved 24 July 1993
Fire Fighting
Issued 24 July 1993
Resolved
Make permanenent repairs to fire main in way of #1 auxiliary generator.
Condition: Unknown
Due 24 July 1993
Resolved 24 July 1993
Construction/Loadline
Issued 24 July 1993
Resolved
Make permanent airtight repairs to driveshaft penetrations of pumproom aft bulkhead.
Condition: Unknown
Due 24 July 1993
Resolved 24 July 1993
Construction/Loadline
Issued 2 October 1992
Resolved
VESSEL'S BALLAST DISCHARGE MONITOR COULD NOT BE TESTED AS PER OPS MANUAL.
Condition: Unknown
Due 5 November 1992
Resolved 2 December 1992
Fire Fighting
Issued 2 October 1992
Resolved
VESSEL'S FOUR FOAM MONITORS , LOCATED FORWARD, DELIVERED LITTLE OR NO WATERPRESSURE. A VIOLATION OF SOLAS CH. II-2 PART D, REG 61.
Condition: Unknown
Due 5 November 1992
Resolved 2 December 1992
Fire Fighting
Issued 2 October 1992
Resolved
DEMONSTRATE PROPER WATER DELIVERY FROM THE FORWARD FOUR FOAM MONITORS.
Condition: Unknown
Due 30 October 1992
Resolved 18 November 1992
Construction/Loadline
Issued 2 October 1992
Resolved
DEMONSTRATE PROPER OPERATION OF FORWARD BALLAST DISCHARGE MONITOR.
Condition: Unknown
Due 30 October 1992
Resolved 18 November 1992
Construction/Loadline
Issued 28 April 1992
Resolved
Make a mid-body ballast tank available for internal examination by a Coast Guard marine inspector at the next U.S. port.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992