← All vessels
RIP VAN WINKLE II
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Northeast District (CGD-NE) · Other hulls named RIP VAN WINKLE II
RIP VAN WINKLE II is a 1982 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1982, most recently in July 2025, along with 267 deficiencies, 3 operational controls and 1 casualty investigation in 2012.
Records from 1982 to 2025. Most recent: inspection, 14 July 2025.
- Built
- 1982
- Last inspected
- 14 July 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 267 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2012
Identity
647761
WDG5977
53773
Flag
UNITED STATES
368366330
Maury page id
psix-53773
Inspections, by type
…with no type recorded10
Years with a record
41 calendar years (1982–2025)
The 89 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)82.3 ft × 32.0 ft × 7.3 ft
Registered tonnagegross 95 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKINGSTON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP5762MMSI 368366330 · active · compulsorily equipped · granted 7 May 2024, expires 7 May 2034
WDG5977MMSI 367552270 · expired · compulsorily equipped · granted 2 November 2012, cancelled 7 January 2023
WDD7180MMSI 367182950 · expired · compulsorily equipped · granted 26 April 2007, cancelled 1 July 2017 · licensed under a name not among this hull’s recorded names (not shown)
WRB2092MMSI not assigned · expired · compulsorily equipped · granted 13 January 1997, cancelled 16 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 89
14 July 2025
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185148
25 September 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8013350
6 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7951044
27 September 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7799420
22 May 2023
MTSA Verification · Annual Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7694236
16 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7484135
9 December 2021
Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7365533
13 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7196675
22 March 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7160809
10 July 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999327
2 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6993639
18 February 2020
Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6910463
7 October 2019
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829474
9 January 2019
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6602812
8 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6408854
26 March 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6379705
2 February 2018
Examination of Repairs · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6348871
2 February 2018
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6355507
4 January 2017
Deficiency Check · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6065911
18 February 2016
Examination of Repairs · Hull Examination · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5817671
21 December 2015
Annual Inspection · MTSA Verification · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5785550
25 August 2014
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4965264
29 June 2012
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4361634
30 January 2012
Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4243661
4 January 2010
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3658517
4 June 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3227264
14 April 2008
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3183947
5 March 2008
Administrative Inspection · Drydock Extension
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3158091
1 April 2007
MTSA Verification · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2897858
19 July 2006
MTSA Verification · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2720451
23 May 2006
Deficiency Check · Security Plan Review - ASP
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2657031
14 April 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2624732
8 February 2006
Deficiency Check · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2581024
17 October 2005
Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2516460
21 June 2005
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2397431
2 May 2005
MTSA Verification · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2347216
23 August 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2173966
6 January 2004
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1969710
13 May 2003
Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1792458
17 June 2002
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1633450
3 June 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625534
23 May 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625526
3 April 2002
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1600253
24 January 2002
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1481130
1 March 2001
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1429490
29 February 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421803
9 February 2000
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1466651
15 November 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 809316
18 March 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 813279
2 March 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1423141
3 March 1998
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1368621
18 November 1997
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1446561
15 April 1997
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1100276
4 March 1997
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1445172
24 August 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095378
23 July 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 740
11 March 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421086
7 November 1995
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1377548
25 May 1995
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 872554
21 March 1995
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1385410
28 April 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 859002
12 April 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 857164
29 March 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1166546
8 March 1994
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1164992
31 August 1993
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1139161
6 April 1993
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1149919
29 September 1992
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 953474
12 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 114205
4 May 1992
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1403536
15 April 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1251643
15 April 1992
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1265661
14 April 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1357930
22 April 1991
Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1232393
23 April 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 911213
8 February 1990
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1218978
24 April 1989
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 897501
21 September 1988
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1194282
9 May 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1039940
25 April 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1034726
4 May 1987
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1323871
28 April 1987
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011248
8 September 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1331816
29 April 1986
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1307383
3 April 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1305501
8 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 983449
2 November 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282710
9 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280288
11 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966537
4 June 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 967812
Deficiency record · 267
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2025
Resolved
THE MI SHALL EXAMINE MACHINERY TO BE ASSURED THAT THEY ARE IN SATISFACTORY CONDITION. MI'S FOUND AN EXHAUST LEAK ON THE PORT MDE. FIX WIIN 7 DAYS; USE GAS METER WHEN ENTERING ER, PROVIDE AC TO MAIN DK FOR VENTILLATION.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 July 2025
Resolved
(a) A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection... Vessel COI is expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024
Resolved
Classes II and III pressure vessels that have a net internal volume of less than 0.14 cubic meters (5 cubic feet) and do not contain hazardous materials must be stamped with either the ASME “U” or “UM” symbol. Compliance with other provisions in this part is not required. 46 CFR 54.01-5(c)(4)
Vessel installed new air compressor for the vessel's whistle - observed as not being ASME certified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2024
Resolved
(a) All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.46 CFR "old T" 183.01-15.
MI noted missing labels on circuit breakers on the number 5 and 13 panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2024
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the
bilge pipe. 46 CFR "old T" 182.25-10.
fwd void bilge suction stainer was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 September 2024
Resolved
(b) Retroreflective material required by this section must be Type I material that is approved under subpart 164.018 of this chapter. 46 cfr "old T" 180.25-25
Vessel was found with 51 adult life jackets having overly degraded retro relefticve tape. Passenger count is limited to 278 until rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2024
Resolved
"Specifications for lifesvaing equipment item required to be of an approved type have been promulgated and are contained in subchapter Q...Ring Life Buoys...160.050" 46 CFR "Old T" 180.05-1(b)
Stbd side ring buoy retro reflective tape was noted as being deteriorated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 September 2023
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessel is required 02 fixed power bilge pumps and only had 01 pumps operational at the time on inspection. The vessel is restricted to the following limitations until it is outfitted with 02 approved fixed power bilge pumps:
1. The vessel will operate with no more than 149 passengers.
2. The machinery room will be monitored at all times by an onboard surveillance system.
3. During any underway operations the machinery room will be observed by a designated deckhand for any abnormalities.
4. The vessel will not extend her route any further south than the Hudson River Pilots dock when passengers are aboard.
5. The vessel will operate with 3 deckhands, a senior deckhand and a Master.
6. An operational gas powered portable pump with sufficient lengths of pick up hose to reach the fixed bilge pick up location in each void will be carried onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2023
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Marine inspector observed diesel fuel leaking on STBD generator fuel filter housing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2023
Resolved
xcept as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc. shall be drip proof protected. Main switchboard front panel cover was not secure/loose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 September 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Vessel purchased a new fixed powered bilge pump. Submit to MSC for plan review with 7 days to ensure pump is adequate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2023
Resolved
Cylinders shall be securely fastened and supported, and where necessary protected against injury. Multiple CO2 containers were unsecured in the galley areas on the main deck and second deck. 46 CFR 181.20-30
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2023
Resolved
Equipment mounted on a hinged door of an enclosure shall be shielded such that no parts of the equipment will be exposed to accidental contact. Main deck electrical panels had blanks, labels, and enclosure shutting capabilities missing.46 CFR 183.10-10
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2023
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel only has 329 life preservers on board. Vessel is restricted to carrying a maximum of 321 passengers, 6 crew members, and 2 persons in addition to the crew. 46 CFR 180.25-5 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2023
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The No.4 void space
bilge piping was loose and inadequate. Vessel was not
able to draw suction out of the No.4 void space.46 CFR 182.25-5 (a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2023
Resolved
All lights, receptacles and switches exposed to the weather shall be watertight. The receptacle in the overhead, centerline 2nd deck is missing a cover. 46 CFR 183.05-35 (b)
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 June 2022
Resolved
Fire hydrants shall be located so that any part of the vessel may be reached. Hole found in fire main piping on second deck; disabling upper deck hydrants
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2022
Resolved
Batteries shall be effectively screened to minimize danger. Batteries were not covered.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 22 June 2022
Resolved
Suitable cover shall be installed in way of all exposed machinery. Guard was nt found to be on portside engine.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 13 May 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Visiting marine inspectors encountered hazardous CO2 levels in engine space. In order to complete annual inspection, vessel must provide a marine chemist certificate verifying safe entry into the engine room.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2021
Resolved
The stability letter must be posted under glass in the pilot house of the vessel. If posting is impracticable, the stability letter must be kept on board in the custody of the licensed operator. Stability letter was not posted or on board the vessel at time of inspection
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 May 2021
Resolved
A garbage management plan meeting paragraph (b) shall be on the ship and each person handling garbage follows the plan. Each garbage management plan must be in writing, describe procedures for minimizing, collecting, processing, storing and discharging garbage and designate the person who is in charge of carrying out the plan.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2021
Resolved
An emergency checkoff list most be posted in a conspicuous place accessible to crew and passengers. The emergency checkoff list shall contain not less than the applicable portions of the emergency instruction list as listed in 46 CFR 185.25-5
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2021
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date: (a) Charts; (b) Sailing directions; (c) Coast pilots; (d) Light lists; (e) Notices to mariners; (f) Tide tables; (g) Current tables; and (h) All other nautical publications necessary
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 13 May 2021
Resolved
If operating in a non-discharge zone, the overboard valve for the black water must be secured. Provide a lock or remove the handle from the black water valve
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2020
Resolved
All electrical connections shall be made in an enclosure to prevent shock and possible hazard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2020
Resolved
All portable fire extinguishers are to be mounted to bulkhead with proper type approved bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2020
Resolved
Vessel found with 370 lifejackets which is 30 short of the total number of passengers permitted carry. Vessel shall carry enough lifejackets for every person on board vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2020
Resolved
Vessel must conduct drills for man overboard and recovery prior to getting underway with passengers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2020
Resolved
705 - Vessel annual inspection deferred until (7/9/2020). Vessel authorized to operate until (7/9/2020).
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 October 2019
Resolved
Provide updated navigational charts for vessel's intended routes of service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2019
Resolved
Vessel restricted to carrying a total of 170 persons. Remaining life jackets onboard were placed out of service. Due to lack of maintanence and incorrect markings. Vessel requires a total of 408 life jackets as noted on current COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 October 2019
Resolved
Provide the following certificates with new vessel name of "RIP VAN WINKLE II": FCC Station License, FCC Safety Radio Certificate, FCC Bridge to Bridge Radiotelephony Certificate.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 7 October 2019
Resolved
Clean and remove excess bilge water from all voids.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 7 October 2019
Resolved
Ensure all crew members working onboard the vessel with security responsibilities have a valid TWIC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Found extensive "daisy chain" electrical connections on the bridge. Remove all daisy chain electrical connections and/or ensure all electrical connections are properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 October 2019
Resolved
Found broken support bracket for bilge piping in #2 void. Make proper repairs to bilge piping and provide adequate piping support.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Install a junction box to ensure wire splices are enclosed for the high level bilge alarm located in #3 void.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 October 2019
Resolved
Observed excessive amounts of rust along the bottom plates of #4 void. Descale to prevent further rust development. Area will be a focal point during next dry dock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Remove all dead end wires in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 October 2019
Resolved
Make proper repairs to leak in coolant line at the expansion tank for the port service generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Ensure all electrical wire connections are in enclosed fixtures. Found multiple electrical connections exposed in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 October 2019
Resolved
Install missing RPM gauge for starboard main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2019
Resolved
Make proper repairs/replace of malfunctioning RPM gauge for port maine engine.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 7 October 2019
Resolved
Repair broken hand rail located on main deck, starboard bow.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 October 2019
Resolved
AC supply vent covers improperly installed by using zipties and strings for fastening. Properly install vent covers in accordance with manufacturer instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2019
Resolved
Repair lube oil leak from starboard main engine lube oil pump.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 7 October 2019
Resolved
Gray water line from concession stand discharging directly overboard. Make repairs to gray water line to ensure proper collection and disposal of waste water are in place. Vessel operates in a No Discharge Zone.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 October 2019
Resolved
Replace bilge strainers at each bilge suction line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019
Resolved
Install auto shut off valves, fire resistant sight gauge glass, and gauge shield for fuel tank sight glass. System to be installed at next dry dock.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 October 2019
Resolved
Properly install water pump and hot water heater expansion tank in engine room to prevent from movement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Found zip ties through out vessel for securing electrical wires. Electrical wires must be secured with metal support brackets at least every 24 inches.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 January 2019
Resolved
Properly secure deck light, mid-deck, fwd.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 January 2019
Resolved
Replace non metallic piping with hard pipe as required by subpart F.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 January 2019
Resolved
Place in service one child-size lifejacket to meet minimum requirement.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 9 January 2019
Resolved
Show proper operation of high water alarm light for steering compartment in pilot house.
Engineering › Bilge Water Management System › Hose
Issued 4 January 2017
Resolved
Place in service new hose or reroute existing for port engine bilge pump.
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2017
Resolved
Provide mounting brackets for cable located on the main deck, forward.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2017
Resolved
Place in service blanks for missing breakers in messdeck distribution panel.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 4 January 2017
Resolved
Provide servicing to B/C/40 portable fire extinguisher in wheelhouse.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 January 2012
Resolved
Make vessel available to a Marine Inspector for a Hull Examination.
Construction/Loadline › Hull › Hull Plating
Issued 4 January 2010
Resolved
Hull plating beneath both shaft seals in the engine room show substantial amounts of rust deterioration due to salt water intrusion through the shaft packing glands. Both port and starboard cofferdams underneath the shaft seals need to be gauged (UT shots) in order to ascertain the amount of metal wastage in these two areas. Currently awaiting the results of the gauging report.
Construction/Loadline › Hull › Side Shell
Issued 4 January 2010
Resolved
Hull plating in the vicinity of the port bow of the vessel is showing substantial amount of wastage adjacent to the forepeak void. Owner to crop and renew wasted hull plating in the area detailed by the attending C.G. marine inspector. Prior to fit-up, and again prior to renewing the hull plating, the owner must contact the a C.G. marine inspector to verify proper installation.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Port side main deck doors need to be replaced or repaired to the satisfaction of the attending CG marine inspector.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Starboard, aft main door needs to be replaced.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Crop and renew wasted metal in way of the main deck doors on the starboard side of the vessel.
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2010
Resolved
Crop and renew wasted metal on the forward main deck, just forward of the enclosed cabin area, and above the forepeak void area.
Construction/Loadline › Structures › Superstructure
Issued 4 January 2010
Resolved
Crop and renew wasted sections of the paddle wheel support structure where it ties into the stern of the vessel.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Provide maintenance to the starboard side main deck doors. Prove that the doors can function properly as a means of escape to the attending CG marine inspector. (At the time of the inspection, both doors were not operable.)
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 4 January 2010
Resolved
Two panels on both the port and starboard side of the main deck cabin need to be pulled to allow for the inspection of the metal bulkhead behind the panels. Two panels also need to be pulled on the forward bulkhead in the main cabin.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Both stair tower doors and door frames need to be repaired/replaced to meet the structural fire protection regulations as outlined in 46 CFR 72.05.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 4 January 2010
Resolved
Remove the port side shaft-packing gland for further examination.
Construction/Loadline › Structures › Superstructure
Issued 4 January 2010
Resolved
Provide maintenance to the window frame's mating surfaces on the forward windows on the main deck.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Properly repair or replace the forward main deck doors to the satisfaction of the attending CG marine inspector.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Provide maintenance to or crop and renew door frames on both forward doors on the main deck.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Provide maintenance to or crop and renew the door frames on the forward doors on the second deck.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Crop and renew wasted areas on the stair wells leading from the second deck up to the upper deck, to include the associated structural members (i.e. handrails) of the stair wells.
Construction/Loadline › Structures › Superstructure
Issued 4 January 2010
Resolved
Crop and renew wasted areas of the handrail forward of the main cabin on both the port and starboard side.
Construction/Loadline › Structures › Superstructure
Issued 4 January 2010
Resolved
Crop and renew the wasted areas located around the handrail foundations on the stair wells leading from the second to the upper decks (both port and starboard side).
Construction/Loadline › Structures › Air Pipe
Issued 4 January 2010
Resolved
Crop and renew the wasted areas on the engine room air vents on the main deck, port side, and aft of the side doors. Replace the engine room vent louvers on both sides of the vessel.
Construction/Loadline › Hull › Stiffener
Issued 4 January 2010
Resolved
Replace the starboard side-shell stiffener in the steering gear compartment, as marked by the attending CG marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2010
Resolved
Clean and de-scale the shell plating and longitudinal in the vicinity of the port side rudder post in the aft-steering compartment for further examination by the attending CG marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 4 January 2010
Resolved
Replace the PVC drain line above the port side rudder post in the aft steering compartment; the PVC line is currently broken.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 January 2010
Resolved
Replace all through-bulkhead penetrations with steel fittings. (In lieu of the existing PVC fittings)
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2010
Resolved
Clean and de-scale the bottom hull plating in the cofferdams underneath the shaft seals in the engine room. (See work item No. 1)
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2010
Resolved
Crop and renew the overhead as marked by the attending CG marine inspector in the stairwells leading to the engine room on both the port and starboard sides.
Engineering › Bilge Water Management System › Manifold
Issued 4 January 2010
Resolved
Re-stencil bilge manifold in engine room.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 January 2010
Resolved
Repair sewage piping in engine room near the forward bulkhead.
Fire Fighting › Fire Main › Material
Issued 4 January 2010
Resolved
Re-weld fire main pipe connection (flush-line) where attached to the sewage line at the forward bulkhead in the engine room.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 January 2010
Resolved
Clean inside of valve body for the sea suction valve removed from the engine room.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 January 2010
Resolved
Remove all through-hull valves for examination.
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2010
Resolved
Take UT shots of deck plating above the hot water heater in the engine room.
Construction/Loadline › Hull › Side Shell
Issued 4 January 2010
Resolved
Crop and renew web frame near ventilation duct in the engine room (starboard side).
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 January 2010
Resolved
Crop and renew engine room ventilation in the port side of the engine room.
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 January 2010
Resolved
Install ladder rung at starboard engine room escape ladder.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 January 2010
Resolved
Conduct general housekeeping in engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 January 2010
Resolved
Install protective sheathing on port side propulsion engine's starter solenoid wires.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 4 January 2010
Resolved
Secure the machinery guard on the front of the port propulsion engine.
Fire Fighting › Ventilation Systems › Ducts
Issued 4 January 2010
Resolved
Prove proper operation of all engine room ventilation ducts (louvers).
Construction/Loadline › Hull › Transverse Frame
Issued 4 January 2010
Resolved
Crop and renew transverse frame/beam in the port side of the engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2010
Resolved
De-scale and clean the deck plating on the port side of the engine room in way of the engine room air intake vent.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Replace door and crop & renew door frame on the port side of the vessel, second deck.
Construction/Loadline › Structures › Door
Issued 4 January 2010
Resolved
Crop and renew door on the starboard side, second deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted section of railing on the forward most part of the second deck.
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2010
Resolved
Repair hole on the starboard-side shell below the vent just aft of the starboard door on the main deck.
Stability › Watertight Integrity › General
Issued 4 January 2010
Resolved
Repair cracked window on the second deck, forward, on the port side of the vessel.
Construction/Loadline › Structures › Superstructure
Issued 4 January 2010
Resolved
Repair window frame on the port side door, second deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted metal on the hand rail, starboard side, leading up to the third deck (bottom of the hand rail).
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted metal on the stanchion for the awning on the third deck, starboard deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted railing on the third deck, forward of the wheelhouse.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 January 2010
Resolved
Repaint back drop for side lights flat black.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 January 2010
Resolved
Crop and renew wasted metal on third deck, port side, seating support for deck bench.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted handrail, leading up to the third deck, on the port side.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 January 2010
Resolved
Replace metal rungs in forepeak tank.
Construction/Loadline › Hull › Collision Strap
Issued 4 January 2010
Resolved
De-scale and clean collision bulkhead in forepeak; provide UT shots around wasted areas. Provide gauging report to attending C.G. inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2010
Resolved
Owner/operator to provide belt gauging report for hull areas in way of the forepeak, tank, mid-body and stern.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 January 2010
Resolved
Provide non-destructive testing of tail shaft key-way for both the port and starboard shafts.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 January 2010
Resolved
Remove all deteriorated life jackets from vessel and replace with new ones.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 January 2010
Resolved
Separate adult life jackets from the children's lifejackets; stow in separate locations with appropriate markings.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Crop and renew wasted handrails as marked on the outside of the vessel.
Construction/Loadline › Structures › Ventilators
Issued 4 January 2010
Resolved
Crop and renew galley vent of the starboard side of the vessel, aft.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 January 2010
Resolved
Remove all life jackets and re-stack to ensure individual lifejackets are able to be pulled from the pile (not sticking together).
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 January 2010
Resolved
Provide documentation that furniture items on second deck are of incombustible construction or remove from space, to include tables, chairs and bar structure.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 January 2010
Resolved
Remove all non-metallic trash cans from accommodation areas.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 4 January 2010
Resolved
Properly label life ring on the port side of the pilot house.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 January 2010
Resolved
Replace life ring line on second deck, starboard side.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 4 January 2010
Resolved
Make permanent repairs to patched MSD (PVC) line in the engine room, at the forward bulkhead.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2007
Resolved
Repair/renew navigation lights to comply with 46 CFR 120.420, the oxidizing film must be removed from the light covers.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 1 April 2007
Resolved
Provide proof of CPR training for at least 50% of the crew.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 1 April 2007
Resolved
Provide proof of first aid certification for at least 50% of the crew.
Lifesaving › Lifebuoys › Serviceable
Issued 1 April 2007
Resolved
Replace port and starboard topside life ring buoys.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2007
Resolved
Secure loose wiring adjacent to port propulsion engine outboard of all bilge alarm sensor wiring in lower compartments IAW 46 CFR 120.340 (b)(4)
Documentation › Certificates/Documents › FCC SSL
Issued 1 April 2007
Resolved
Provide all current FCC certificates IAW 46 CFR 121.502
Engineering › Bilge Water Management System › Piping
Issued 1 April 2007
Resolved
Clean engine room bilge, forward end.
Construction/Loadline › Structures › Ventilators
Issued 1 April 2007
Resolved
Install ventilation in fuel tank compartment no later than the completion of the next dry dock IAW 46 CFR 119.470.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 April 2007
Resolved
Conduct a man over board drill with full crew complement.
Operations/Management › Drills/Instruction › Fire
Issued 1 April 2007
Resolved
Conduct a fire drill with full crew complement.
Engineering › Steering Gear System › Linkage
Issued 1 April 2007
Resolved
Replace broken grease fitting on starboard rudder tiller arm link.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 April 2007
Resolved
Renew nonskid on main deck to 01 ladder IAW 46 CFR 122.100
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 April 2007
Resolved
Properly mark engine room escape hatch on both top side and bottom side of hatch IAW 46 CFR 116.500 (j)
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 1 April 2007
Resolved
Replace the inside door handle on the starboard side emergency escape hatch from the engine room, to facilitate transit from engine room escape hatch IAW 46 CFR 116.500 (j)
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 1 April 2007
Resolved
Reclamp copper fuel oil return lines in front of both main propulsion engines.
Personnel › Training › First Aid/CPR
Issued 17 April 2006
Resolved
Provide proof of First Aid and CPR training for 50% of the crew (minimum of 3 persons).
Engineering › Fuel Oil Service System › Hose
Issued 17 April 2006
Resolved
Install chaffing gear as needed on hoses in the engineroom.
Electrical › Electric Generation Source (service) › Generator
Issued 17 April 2006
Resolved
Replace missing manufacturer's data plate on the starboard generator.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 April 2006
Resolved
Repair retro-reflective material, vessel name marking, and/or clips on 40 adult lifejackets. Vessel is limited to 354 adult passengers until this deficiency is cleared.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 April 2006
Resolved
Repair retro-reflective material and/or clips on 11 child size lifejackets. The vessel is limited to 30 child size passengers until this deficiency is cleared.
Construction/Loadline › Structures › Deck Plating
Issued 10 February 2006
Resolved
Crop and renew wasted deck on port side emergency exit (crop to good metal and replace insulation).
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2006
Resolved
Weld up hole under stbd packing gland.
Construction/Loadline › Structures › Deck Plating
Issued 10 February 2006
Resolved
Crop and renew deck plate support in engine room
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 10 February 2006
Resolved
Repair sewage tank access cover.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 February 2006
Resolved
Crop and renew wasted area of port and stbd hand rails on bow.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 February 2006
Resolved
Replace chain for passenger entrance at bow.
Construction/Loadline › Structures › Deck Plating
Issued 8 February 2006
Resolved
Crop and renew wasted areas under all toilets. (Crop to good metal)
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 February 2006
Resolved
Remove outboard panels on intermediate deck in way of support stanchions.
Construction/Loadline › Structures › Superstructure
Issued 8 February 2006
Resolved
Original comment: Crop and renew to good metal wasted areas on top of pilot house. New agreement: Apply doublers to wasted areas on top of pilot house.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2005
Resolved
Label all bilge alarm indicators for the spaces with bilge alarms.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2005
Resolved
Replace missing light cover for wheelhouse.
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2005
Resolved
FCC Safety Certificate is expired.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 2 May 2005
Resolved
FCC Operator License expired.
Engineering › Steering Gear System › Pin
Issued 2 May 2005
Resolved
Replace missing cotter pin on port side of steering gear.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2005
Resolved
Replace wire nuts on starboard engine gauges with suitable wire connectors.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2005
Resolved
Secure all loose bottles in lazarette.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2005
Resolved
Repair lighting, operating intermittently, in port side engine room.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 May 2005
Resolved
Vessel limited to 349 passengers. Replace retro reflective tape on 21 lifejackets to raise total person allowed to 370.
Fire Fighting › Fire Main › Pressure
Issued 2 May 2005
Resolved
Repair or replace inoperable fire pump pressure gauge.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 May 2005
Resolved
Provide updated navigation publications (light list, tide table, tidal current tables, coast pilot and marine charts).
Stability › Intact Stability (when using lifting gear) › General
Issued 18 May 2004
Resolved
Remove all galley stores from lazarette void space per restriction #2 of stability letter.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 May 2004
Resolved
Tighten shaft packing to secure leaks (excessive).
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 18 May 2004
Resolved
Remove personnel/passenger hazard-knife edged anchor bracket-on forecastle.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 May 2004
Resolved
Provide publication-inland navigation rules.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2004
Resolved
Repair or remove secondary VHF.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 May 2004
Resolved
Prove CPR/First Aid training for 50% of crew.
Lifesaving › Hand Flares › Expired
Issued 18 May 2004
Resolved
Renew pyro prior to expiration in June 2004.
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 May 2004
Resolved
Secure leaking sink drain piping in lazarette-port side.
Documentation › Certificates/Documents › Stability Letter
Issued 18 May 2004
Resolved
Post stability letter and emergency instructions in pilot house.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 18 May 2004
Resolved
Mark emergency exits on both sides "Emergency Exit, Keep Clear" in 1 inch lettering as required by 46 CFR 185.30-15.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2004
Resolved
Renew unservicable clips and retroreflective material as necessary for 69 adult lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2004
Resolved
Renew 17 unservicable adult lifejackets. (Remove 17 unservicable adult and 1 unservicable child lifejacket) Vessel limited to 383 adults until 17 unservicable adult lifejackets are replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2004
Resolved
Replace two missing light cages in E/R.
Fire Fighting › Fire Pumps › Arrangement
Issued 8 January 2004
Resolved
Provide guard on port engine secondary fire pump drive belt. Replace drive belt.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 January 2004
Resolved
Renew aft handrail bulkhead connections on stbd side.
Construction/Loadline
Issued 8 January 2004
Resolved
Demonstrate proper operation of bilge alarms.
Construction/Loadline
Issued 8 January 2004
Resolved
Renew wasted middle course port and stbd bulwarks on bow.
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
Repair bow door closers and reinstall door hardware. (1st and 2nd deck)
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
First level stbd bow door (emergency exit)-free up overhead slide bolt and repair door frame as original.
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
Unblock and free up stbd side embarkation doors.
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
Crop and renew or otherwise repair door bases and frames on second deck on top of stair towers. (Safety hazard for passengers)
Construction/Loadline
Issued 8 January 2004
Resolved
Crop and renew holed areas of second deck fwd bulkhead.
Fire Fighting
Issued 8 January 2004
Resolved
Replace suicide style fire nozzles with CG approved nozzles. Provide spanner for third deck fire station.
Engineering
Issued 8 January 2004
Resolved
Renew base plate for brow winch hand crank.
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
Remove slide bolt locks from outboard sides of port and stbd embarkation doors.
Accommodation/Occupational Safety
Issued 8 January 2004
Resolved
Replace broken window glass stbd door and centerline window second deck fwd.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 January 2004
Resolved
Reinstall guards over air handler coils as original.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 January 2004
Resolved
Repair/Renew broken conduit to air handler on third deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2004
Resolved
Reattach cable clamps where broken from second deck overhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2004
Resolved
Remove dead end wire from stbd side overhead second deck fwd.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 July 2003
Resolved
Provide 32 adult life jackes for total adult count of 400.
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 May 2003
Resolved
14 Child, 76 Adult lifejackets rejected above lifejackets to be destroyed total passenger count reduced to 304. child size lifejacket must be provided for each child size person on board. Reduce passenger coutn until new lifejackets approved by USCG. LEGACY COMPONENT DESC: Condition
Communications › Radio Communications
Issued 13 May 2003
Resolved
REnew emergency broadcast placard with vessel specific info as required by 46 cfr 121.506 and 46 cfr 121.510.
Engineering › Bilge Water Management System
Issued 13 May 2003
Resolved
Renew bilge piping in collisioin bulkhead compartment. LEGACY COMPONENT DESC: Piping
Personnel › Training
Issued 13 May 2003
Resolved
Post senior deckhand in writing as required by COI.
Electrical › Electric Supply System (service)
Issued 13 May 2003
Resolved
REmove wire nutes from aft A/C unit. LEGACY COMPONENT DESC: Cable
Fire Fighting › Fire Hoses
Issued 13 May 2003
Resolved
Replace fire hose on top deck. LEGACY COMPONENT DESC: Condition
Construction/Loadline › Structures
Issued 13 May 2003
Resolved
Seal hole on ventilation intake for E/r near port side E/R enterance. LEGACY COMPONENT DESC: Trunk
Accommodation/Occupational Safety › Occupational Safety
Issued 13 May 2003
Resolved
Secure CO2 cylinders (soda) under bar area.
Communications › Visual Communication
Issued 13 May 2003
Resolved
Post emergency exit sign on additional door on main deck.
Stability › Watertight Integrity
Issued 17 June 2002
Resolved
REPLACE STARBOARD SHAFT LOG AS ORIGINAL PRIOR TO OPERATING IAW COI.
Communications
Issued 3 April 2002
Resolved
Post emergency broadcast placard near radio.
Documentation › Safety/Response Plans/Programs
Issued 3 April 2002
Resolved
Fire control plan - update and submit for OCMI approval. LEGACY COMPONENT DESC: Fire Control Plans
Documentation › Logs/Records
Issued 3 April 2002
Resolved
Maintain training and drill logs. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Lifesaving › Lifejacket/PFD (General)
Issued 3 April 2002
Resolved
Replace retroreflective tape and clean lifejackets indicated during inspection. LEGACY COMPONENT DESC: Retroreflective Material
Accommodation/Occupational Safety › Occupational Safety
Issued 3 April 2002
Resolved
Provide guard for front of #2 MDE. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Personnel › Manning/Qualifications
Issued 3 April 2002
Resolved
Provide proof of CPR/First Aid for 50% of the crew. LEGACY COMPONENT DESC: First Aid Certified Personnel
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 April 2002
Resolved
Remove sharp edges on handrail - 2nd deck, port side. LEGACY COMPONENT DESC: Open Deck Space
Electrical › Electrical Distribution System (service)
Issued 3 April 2002
Resolved
Remove wire nuts on stern air conditioning unit LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety
Issued 2 March 1999
Resolved
PROVIDE INSECT SCREEN FOR POTABLE WATER TANK.
Engineering
Issued 2 March 1999
Resolved
PROVIDE FUEL TANK FLAME SCREENS.
Lifesaving
Issued 2 March 1999
Resolved
ALL BUOYANT APPARATUS MUST BE PROPERLY LINKED TO WEAK LINK (IAW 46 CFR 180.130)
Fire Fighting
Issued 2 March 1999
Resolved
PROVIDE FIRE HOSE FOR 2ND DECK FIRE STATION. (IAW 46 CFR 181.320)
Lifesaving
Issued 2 March 1999
Resolved
PROVIDE ADDITIONAL CHILDS PFD. (IAW 46 CFR 180.71)
Navigation
Issued 2 March 1999
Resolved
NEED TO PROVIDE SHIPS BELL FOR VESSEL. 72 COLREGS ANNEX III
Documentation
Issued 2 March 1999
Resolved
PROVIDE COD FOR INSPECTOR REVIEW/APPROVAL IAW 46 CFR 67.7
Lifesaving
Issued 2 March 1999
Resolved
1. REPLACE RETRO REFLECTIVE TAPE ON BA. (IAW 46 CFR 160.027)_x001C_ 2. REPLACE BA WATERLIGHT LANDYARDS (BREAKING DOWN) (IAW 46 CFR 180.137)
Lifesaving
Issued 2 March 1999
Resolved
PROVIDE REQUIRED 60' LIFELINE TO UPPER PASSENGER DECK RING BUOY. (IAW 46 CFR 180.70)
Lifesaving
Issued 2 March 1999
Resolved
INSTALL (2) LIFEJACKET PLACARDS ON EACH JACKET DISTRIBUTION DECK. (IAW 46 CFR 185.516)
Lifesaving
Issued 2 March 1999
Resolved
CHAIN CO2 BOTTLES IN LAZARETTE.
Documentation
Issued 2 March 1999
Resolved
ENSURE THAT 50 PERCENT OF THE CREW HOLDS A VALID RED CROSS FIRST AID/CPR CARD. (IAW NVIC 1-91)
Fire Fighting
Issued 2 March 1999
Resolved
PROVIDE NEW BELT FOR FIRE PUMP.
Navigation
Issued 2 March 1999
Resolved
CLEAN HEAVY RESIDUE OFF OF NAVIGATION LIGHTS.
Fire Fighting
Issued 2 March 1999
Resolved
LABEL FIRE HOSES WITH VESSEL'S NAME.
Fire Fighting
Issued 2 March 1999
Resolved
PROVIDE NEW PRESSURE GUAGE FOR PORT SIDE FIRE PUMP DISCHARGE.
Accommodation/Occupational Safety
Issued 2 March 1999
Resolved
REPAIR BROKEN DRAIN LINE ON AC UNIT LOCATED ON UPPER PASSENGER DECK.
Electrical
Issued 2 March 1999
Resolved
1. PERMANENTLY MOUNT MAST LIGHT WIRING._x001C_ 2. REPAIR WIRE CONNECTORS PULLING OUT OF MAST LIGHT._x001C_ 3. INSTALL BLANK IN WHEELHOUSE ELECTRICAL PANEL-STARBOARD SIDE._x001C_ 4. PROVIDE RUBBER MATTING IN FRONT OF GENERATOR CONTROL PANELS - ENG ROOM.
Lifesaving
Issued 2 March 1999
Resolved
1. FLARE BOX MUST BE PAINTED IN BRIGHT COLOR SCHEME & MARKED "DISTRESS SIGNALS". (IAW 46 CFR 185.614)_x001C_ 2. LABEL ADULT PFD LOCATION ON SECOND DECK. (IAW 46 CFR 180.78)_x001C_
Fire Fighting
Issued 2 March 1999
Resolved
PROVIDE MACHINERY GUARD FOR FIRE PUMP BELT.
Lifesaving
Issued 4 March 1997
Resolved
Stow Child size life preservers in a seperate area clearly marked "CHILD LIFE PRESERVERS" as per 46CFR 117.78.
Fire Fighting
Issued 4 March 1997
Resolved
Produce and post a Fire Control Plan in the main passenger area as per _x001C_ 46 CFR 116.530.
Fire Fighting
Issued 4 March 1997
Resolved
Post Station Bill in pilot house as per 46 CFR 122.514.
Documentation
Issued 4 March 1997
Resolved
Commence and properly maintain a log of all ships drills including crew members who participated as per 46 CFR Part 122.
Navigation
Issued 4 March 1997
Resolved
Clean the lenses on all the ships navigation lights as per 46 CFR 120.420.
Lifesaving
Issued 4 March 1997
Resolved
Provide three smoke flares as per 46 CFR 117.68 before getting underway.
Documentation
Issued 24 August 1996
Resolved
BY 24SEP96, PROVIDE TO MSO CORPUS CHRISTI, SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS ESTABLISHED AND IMPLEMENTED A CHEMICAL TESTING PROGRAM AS REQUIRED BY 46 CFR PART 16.
Construction/Loadline
Issued 7 November 1995
Resolved
Clean areas of engineroom bilge as noted during inspection so inspection can be completed.
Lifesaving
Issued 21 March 1995
Resolved
REPLACE 01 RING BUOY WITH LINE.
Lifesaving
Issued 21 March 1995
Resolved
REPLACE 21 ADULT PFD'S AND 05 CHILDRENS PFD'S.
Electrical
Issued 29 March 1994
Resolved
Label breaker circuits on circuit panel located in pilot house.
Engineering
Issued 29 March 1994
Resolved
Install oil pressure line on port engine.
Construction/Loadline
Issued 29 March 1994
Resolved
Renew anchor line.
Lifesaving
Issued 29 March 1994
Resolved
Provide thirty three (33) adult and one (1) child approved PFD's, vessel isrestricted to a total of 367 persons on board vessel, until additional PFD's are on board to comply with COI.
Electrical
Issued 14 April 1992
Resolved
REMOVE ALL WIRE NUTS ON ELECTRICAL WIRING IN ENGINE ROOM AND REPLACE WITH UL APPROVED PRESSURE TYPE CONNECTORS OR SOLDER AND TAPE IN ACCORDANCE WITH 46 CFR PART 183.05-(B)(3). _x001C_ _x001C_
Documentation
Issued 14 April 1992
Resolved
OBTAIN A CURRENT COPY OF INLAND NAVIGATION RULES PUBLICATION._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 14 April 1992
Resolved
VESSEL IS RESTRICTED TO 39 CHILDREN ON BOARD UNTIL ADDITIONAL LIFE PRESERVERS ARE OBTAINED AND STAMPED BY THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Electrical
Issued 14 April 1992
Resolved
REPLACE MISSING PROTECTIVE METAL GUARD FOR LIGHT GLOBE ON 01 DECK._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 14 April 1992
Resolved
REMOVE EXCESSIVE OIL IN ENGINEROOM BILGE._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 14 April 1992
Resolved
INSTALL GUARD OVER PUMP DRIVE BELT ON PORT ENGINE._x001C_ _x001C_ _x001C_
Engineering
Issued 14 April 1992
Resolved
RENEW OR REPLACE FLAME SCREENS ON BOTH PORT AND STBD FUEL VENTS AND ON PORTWATER TANK VENT._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 22 April 1991
Resolved
RENEW PRESSURE GAGE ON FIRE FIRE PUMP.
Engineering
Issued 22 April 1991
Resolved
BILGE IN ENGINE ROOM NEEDS TO BE CLEANED.
Lifesaving
Issued 22 April 1991
Resolved
RENEW OR REPAIR SECURING CLIPS ON THE (141 ADULT,10 CHILDREN) PFD'S THAT_x001C_ WERE REJECTED.
Electrical
Issued 22 April 1991
Resolved
LABEL ALL EMERGENCY LIGHTS WITH A LEGIBLE RED "E".
Fire Fighting
Issued 22 April 1991
Resolved
FIRE AXE ON PILOT HOUSE NEEDS TO BE LABELED WITH VESSELS NAME.
Engineering
Issued 22 April 1991
Resolved
RENEW PORT ENGINE BILGE PUMP DRIVE BELT.
Lifesaving
Issued 22 April 1991
Resolved
PADDLES ON LIFE FLOATS NEED TO BE LABELED WITH VESSELS NAME.
Lifesaving
Issued 22 April 1991
Resolved
#2 LIFE FLOAT WATER LIGHT IS TO BE MADE OPERABLE.
Lifesaving
Issued 28 April 1987
Resolved
POST EMERGENCY CHECK OFF LIST.
Lifesaving
Issued 28 April 1987
Resolved
REPAIR OR REPLACE TWO (02) RING BUOYS LOCATED OUTSIDE OF PILOT HOUSE.
Casualty record · 1
29 June 2012Routine · role: Involved in a Marine Casualty · activity 4361634
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CAROLINA QUEEN (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.