← All vessels
VIRGEN DEL CARMEN III
VIRGEN DEL CARMEN III is a 1982 tank ship. The Coast Guard has recorded 20 inspections since 1987, most recently in September 2023, along with 18 deficiencies and 3 operational controls.
Records from 1987 to 2023. Most recent: inspection, 13 September 2023.
- Built
- 1982
- Last inspected
- 13 September 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8027690 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HPSI
53776
Flag
PANAMA
—
Maury page id
psix-53776
Inspections, by type
…with no type recorded8
Years with a record
8 calendar years (1987–2023)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4999 - Convention (Subpart B), Gross Ton
9478 - Displacement, Ton
5990 - Dead Weight, Ton
1499 - Convention (Subpart B), Net Ton
9478 - Displacement, Ton
5990 - Dead Weight, Ton
1499 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
13 September 2023
Deficiency Check
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7790906
16 February 2011
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3947071
11 February 2011
COC-GAS Renew · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3940675
10 February 2011
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3944916
13 December 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3114847
12 July 2007
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2992298
25 April 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2915380
5 January 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2850907
3 January 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2849649
1 December 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2544254
22 June 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2399128
24 February 2005
ISPS II Exam · COC-GAS Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2300517
21 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2298727
18 August 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1251402
27 April 1992
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 350341
25 November 1989
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1216680
26 September 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 479846
20 May 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 323432
6 May 1987
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020905
1 May 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1322024
Deficiency record · 18
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 February 2011
Resolved
During cargo operations at PPG Facility the vessel detected cargo vapor leaks at the starboard manifold, starboard #1 tank dome, starboard #2 tank dome, and port #3 tank dome. Prior to loading or discharging cargo in the U.S. the vessel must submit documentation from the certificate issuing authority attesting to the proper operation of the entire cargo containment system. SOLAS 2009 Ch. 1 Reg. 11
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 11 February 2011
Resolved
1835: #2P maximum allowable relief valve seal is broken. Pressure relief valves shall be set and sealed by a competent authority acceptable to the Administration. Set and seal prior to cargo operations. IGC Code VIII 8.2.6 To the satisfaction of the Coast Guard.
Fire Fighting › Fire Main › Condition
Issued 11 February 2011
Resolved
0730: Starboard side forward of compressor room fire main at bend has several pinhole leaks. Vessel must have ready availability of fire extinguishing appliances. SOLAS 74 Ch II-2 Reg 3(a) To the satisfaction of the Coast Guard.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 11 February 2011
Resolved
0730: Port side forward of compressor room near cargo pump 2P has a dime size leak in fixed deck spray water system. Vessel must have ready availability of fire extinguishing appliances. SOLAS 74 Ch II-2 Reg 2(a) To the satisfaction of the Coast Guard.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 11 February 2011
Resolved
1510: Voyage data recorder is showing an incorrect IMO number, not meeting the requirements of IMO resolution A.861(20). SOLAS 2004 Ch V Reg 20. To the satisfaction of the Coast Guard.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 11 February 2011
Resolved
Water closet accommodation shall be provided for the exclusive use of occupants of the hospital accommodation. Water closet is inoperable. ILO 147 To the satisfaction of the Coast Guard.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2007
Resolved
The vessel's #1 ship service generator has an exhaust leak located on the # 3 cylinder. Repair to the satisfaction of the certificate issuing authority.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2007
Resolved
The vessl's #3 ship service generator has oil saturated lagging located in between the #3 and #4 cylinders. Repair leaks and replace lagging to the satisfaction of the certificate issuing authority.
Navigation › Piloting/Steering › Gyro Compass
Issued 25 April 2007
Resolved
Vessel's Gyro Compass is "hunting" and is not operating properly. Vessel is required to provide a technician's report attesting to the proper repair and operation of the vessel's Gyro Compass prior to departure from port.
Deck/Cargo › Towing › Chocks
Issued 5 January 2007
Resolved
Starboard Chock forward of amidships was torn from the deck by a tug boat during mooring evolution. Damage did not cause penetration of the skin of the ship, but did cause damage to 1 lower section of life line. Vessel issued 1 deficency for damaged life lines.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 24 February 2005
Resolved
Quick-closing valves serving blue Vapor Balancing Lines closed too quickly (10 seconds). Prior to using pipelines/connections in U.S. waters, closing of valves must be demonstrated to close within 20-30 seconds. To be completed to the satisfaction of class.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 February 2005
Resolved
Class to attest to the satisfactory condition of the expansion joint serving #1 starboard deepwell cargo pump (rubber has cracks). To be completed to the satisfaction of class.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 24 February 2005
Resolved
Provide proper demonstration of deck spray in way of port side bridge on forward side of wheelhouse. To be completed to the satisfaction of class.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 24 February 2005
Resolved
Remove paint from fusible links in way of cargo tank domes, as necessary. To be completed to the satisfaction of class.
Navigation
Issued 18 August 1992
Resolved
Place a copy of the Navigation Rules on board the vessel prior to next U.S.port.
Navigation
Issued 18 August 1992
Resolved
Place copy of 1992 Tidal Current Tables on board the vessel prior to next U.S. port.
Deck/Cargo
Issued 18 August 1992
Resolved
Demonstrate proper operation of the indicator device for the "Top Spray" quick closing valve on the No. 1 Port cargo tank at the next U.S. port.
Unknown
Issued 25 November 1989
Resolved
PROVE OPERATION OF INERT GAS GENERATOR PRIOR TO LOADING CARGO REQUIRING INERT GAS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.