← All vessels
FORMOSA ONE
FORMOSA ONE is a 1981 tank ship. The Coast Guard has recorded 60 inspections since 1984, most recently in February 2004, along with 77 deficiencies and 2 operational controls.
Records from 1984 to 2004. Most recent: inspection, 5 February 2004.
- Built
- 1981
- Last inspected
- 5 February 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 77 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8002028 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELAV9
53778
Flag
LIBERIA
—
Maury page id
psix-53778
Inspections, by type
…with no type recorded35
Years with a record
18 calendar years (1984–2004)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it17560 - Convention (Subpart B), Gross Ton
7898 - Convention (Subpart B), Net Ton
31378 - Dead Weight, Ton
7898 - Convention (Subpart B), Net Ton
31378 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 60
5 February 2004
MTSA/ISPS Verification · Certificate of Compliance · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1996384
23 September 2003
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1911246
17 June 2003
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1820622
27 February 2003
Security Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1750257
17 November 2002
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1713147
14 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705868
19 July 2002
Security Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1647931
14 July 2002
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1649198
25 March 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1597510
26 December 2001
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1646433
22 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282382
17 September 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 282274
16 September 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282225
18 August 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411950
23 March 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 191515
23 March 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 771182
21 March 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 771180
20 March 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 191514
18 August 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419314
18 August 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 467631
18 August 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1472856
16 May 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 416013
11 February 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 499604
12 August 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 407793
12 August 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1407942
20 November 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 397365
20 November 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187700
23 May 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 391429
23 May 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1086088
23 May 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181043
22 December 1995
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 386028
11 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383434
11 October 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1188473
14 April 1995
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 377126
21 December 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857512
20 December 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 373304
3 October 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175391
16 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 370602
7 June 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 367437
7 June 1994
MARPOL Annex V Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1363032
5 November 1993
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415913
29 October 1993
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1145835
27 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 474026
21 June 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1152010
14 January 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 828085
20 November 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 443251
16 November 1991
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 347147
16 November 1991
Certificate of Compliance
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1244213
13 July 1989
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 462519
1 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 522223
13 December 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1312943
9 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020985
6 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020380
6 April 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020387
8 March 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 314612
27 July 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 469522
24 July 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303406
24 July 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1287502
5 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 465733
13 June 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 536682
Deficiency record · 77
Engineering › Steering Gear System
Issued 5 February 2004
Resolved
Starboard steering ram leaking excessively during operational test. Repair steering ram seal to minimize leakage to the satisfaction of attending Class Society Surveyor prior to departure.
SOLAS 74, II-1, reg 29/33 CFR 164.39(f) LEGACY COMPONENT DESC: Ram Seal
Electrical › Electrical Distribution System (service)
Issued 5 February 2004
Resolved
Electrical wiring leading to the alarm panel in Cargo Control Room was not intrinsically safe. Ensure all wiring into the alarm panel is in good condition and intrinsically safe to the satisfaction of an attending Coast Guard Marine Inspector prior to departure. IBC, reg 19.9 LEGACY COMPONENT DESC: Wiring
Fire Fighting › Fire Hoses
Issued 5 February 2004
Resolved
Observed several fire hoses in the engine room worn and rotted. Spot checked 4 hoses and tested under pressure. One fire hose failed. Replacements were onboard. Test all fire hoses in the engineering spaces to ensure good condition to the satisfaction of USCG Marine Inspector. SOLAS 74, II-2, LEGACY COMPONENT DESC: Condition
Fire Fighting › Nozzles
Issued 5 February 2004
Resolved
Observed one missing nozzle on fire station in the Cargo Pump Room. Provide one nozzle for fire station in the cargo pump room.
SOLAS 74, II-2, reg 21 LEGACY COMPONENT DESC: Number
Electrical › Lighting (emergency)
Issued 5 February 2004
Resolved
Emergency light for the staboard boat deck embarkation was inoperable. Repair emergency lighting for embarkation to the satisfaction of attending Coast Guard Marine Inspector prior to departure. LEGACY COMPONENT DESC: Embarkation emergency lighting
Lifesaving › Launching Appliances
Issued 5 February 2004
Resolved
While conducting an abandon ship drill, the starboard side sheave on the aft davit was frozen and did not turn. Renew or repair sheave and demonstrate proper operation of the starboard life boat davit to the satisfaction of an attending Class Society Surveyor. LSA Code 6.1.1 LEGACY COMPONENT DESC: Davit
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 5 February 2004
Resolved
During inspection of the galley and the reefer spaces, observed several boxes of provisions that were rotten. Remove all rotten provisions from reefer and properly dispose. Vessel has ordered additional provisions while in the port of Point Comfort.
ILO 147 LEGACY COMPONENT DESC: Rotten provisions
Lifesaving › Lifeboat
Issued 5 February 2004
Resolved
Retro reflective tape on both the port ands starboard lifeboat were baldy wasted and painted over. Affix new retroreflective tape in accordance with LSA Code 1.2.2.7 to the satisfaction of an attending Class Society Surveyor prior to departure.
LSA Code 1.2.2.7 LEGACY COMPONENT DESC: Hull
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 5 February 2004
Resolved
Observed three doors in the reefer spaces that were not outfitted with emergency egress device. Provide a means of emergency egress from these spaces to the satisfaction of an attending USCG Marine Inspector prior to departure from port.
ILO 147 LEGACY COMPONENT DESC: Egress Escape Latch
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 5 February 2004
Resolved
Tiling in the refrigeration space was broken and in poor condition causing an unsanitary and unsafe environment. Remove or repair deck in reefer space prior to next U.S. voyage.
ILO 147 LEGACY COMPONENT DESC: Deck
Communications › Radio Communications
Issued 17 June 2003
Resolved
Vessel required to have 3 working two-way VHF radiotelephones as per the Safety Radio Certificate. One VHF Radiotelephone is inoperable. LEGACY COMPONENT DESC: VHF Radiotelephone
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2002
Resolved
Numerous lighting fixures missing, broken or wasted.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 November 2002
Resolved
Due to numerous operations not being completed and/or documented, require external ISM Audit by class society.
There was no maintance record for lifeboats, steering gear tests, and other equipment found in unsat. condition.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 17 November 2002
Resolved
Ship service diesel generator has various fuel leaks from high pressure fuel pumps.
Engineering › Diesel Engine (propulsion-electric)
Issued 17 November 2002
Resolved
Main propulsion engine has excessive steam leak from the exhaust compensator and insulation deteriorated
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 17 November 2002
Resolved
Question validity of 2/O and 3/O licenses and STCW training. No original Liberian onboard- only application
Fire Fighting › Miscellaneous Items
Issued 17 November 2002
Resolved
Numerous fire dampers inoperable and/or labeled incorrectly.
Construction/Loadline › Structures › Door
Issued 17 November 2002
Resolved
Class A Fire door inoperable (0-2 level port side)
Fire Fighting › Fire Hydrants › Condition
Issued 17 November 2002
Resolved
Numerous fire hydrant vales frozen and in need of maintenance. Some missing gaskets and some nozzels frozen.
Lifesaving › Lifeboat
Issued 17 November 2002
Resolved
The overall condition of lifeboats and the equipment was extremely unsat. Provisions were wasted and/ or missing. Plastic water jugs cracked from being left out in the sun. Wooden floor boards were not affixed to the lifeboat. Neither could be lowered without use of an air winch.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 November 2002
Resolved
All lifejackets on board were old style cork PFD. Question buoyancy and validity of every life jacket on vessel.
Lifesaving › Immersion Suits
Issued 17 November 2002
Resolved
3 Immersion suits missing, 3 do not have lights attached.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 17 November 2002
Resolved
High level and overfill alarms not labeled, lights on deck not functioning, alarms not sounding.
Deck/Cargo › Inert Gas System
Issued 26 December 2001
Resolved
IGS SYSTEM NOT WORKING
Electrical
Issued 16 September 2000
Resolved
MISSING ELECTRICAL MATTING BEHIND CONTROL PANEL IN CONTROL ROOM (SOLAS 74 II/27); INSTALL ELECTRICAL MATTING.
Fire Fighting
Issued 16 September 2000
Resolved
SELF CLOSING STAIR TOWER DOORS OUT OF ADJUSTMENT (SOLAS 74 II/57); ADJUST DOORS FOR PROPER OPERATION.
Deck/Cargo
Issued 16 September 2000
Resolved
UNABLE TO TEST OVER FILL ALARMS (46CFR39.20-7); CONDUCT SATISFACTORY TEST OF ALARMS PRIOR TO LOADING CARGO IN THE U.S.
Lifesaving
Issued 16 September 2000
Resolved
NO FLAMMABLE VAPOR METERS IN WORKING CONDITION (46CFR153.465); PROVIDE TWO OPERATIONAL METERS.
Lifesaving
Issued 16 September 2000
Resolved
EXESSIVE EXHAUST LEAK IN PORT LIFEBOAT (SOLAS 74 I/10); REPAIR EXHAUST LEAK.
Deck/Cargo
Issued 18 August 1998
Resolved
Vapor control pipe flange(s) not in compliance with 46 CFR 39. To be corrected prior to cargo operations requiring VCS connection.
Unknown
Issued 18 August 1998
Resolved
Warning statement missing from manuevering fact sheet as required in 33 CFR164.35(7).
Lifesaving
Issued 18 August 1998
Resolved
O2 meter not working properly needs to be repaired or replaced.
Lifesaving
Issued 23 May 1996
Resolved
Have class inspect wasted lifeboat davit sheaves and make recommendation for repairs.
Lifesaving
Issued 23 May 1996
Resolved
Have class inspect emergency fuel oil shut off valve for emergency generator and ensure proper operation.
Construction/Loadline
Issued 23 May 1996
Resolved
Have class make recommendations for repair of hole in forepeak air pipe vent located in bos'n stores.
Lifesaving
Issued 23 May 1996
Resolved
Replace damaged lifeboat compass for port lifeboat.
Fire Fighting
Issued 23 May 1996
Resolved
Replace three wasted fireman's outfits. Outfits unserviceable.
Deck/Cargo
Issued 23 May 1996
Resolved
Repair high level and overfill alarms for cargo tanks, have class inspect for proper operation.
Engineering
Issued 23 May 1996
Resolved
Have class inspect and make recommendation for repairs for wasted salt water discharge cooling line to main diesel engine air box cooler.
Deck/Cargo
Issued 11 October 1995
Resolved
REPAIR JURY-RIGGED ELECTRICAL ALARM SYSTEM IN THE CARGO CONTROL ROOM WHERE WIRING IS DEADENDED AND IS NOT INTRINSICALLY SAFE. _x001C_ -PRIOR TO CARGO OPERATIONS-_x001C_ SOLAS II-1 PART D
Deck/Cargo
Issued 11 October 1995
Resolved
PROVIDE FLAG STATE DOCUMENTATION SHOWING ACCEPTANCE OF THE CARGO PUMP CONTROL SYSTEM WHERE THE CONTROL CABINET IS INOPERABLE AND ADJUSTABLE WRENCHES ARE USED TO CONTROL THE PUMPS._x001C_ BCH 2.11
Deck/Cargo
Issued 11 October 1995
Resolved
MAKE REPAIRS TO HIGH LEVEL AND OVERFLOW ALARMS WHERE MALFUNCTIONING. BOTH ALARMS SOUND AT ONCE DURING A HIGH LEVEL CONDITION. PROVIDE FLAG OR CLASS DOCUMENTATION OF REPAIRS. DEMONSTRATE OPERATION OF BOTH SYSTEMS. _x001C_ 46CFR153.408
Deck/Cargo
Issued 11 October 1995
Resolved
DEMONSTRATE PROPER OPERATION OF VAPOR PRESSURE VACUUM ALARMS. _x001C_ _x001C_ _x001C_ 46CFR39.20
Documentation
Issued 11 October 1995
Resolved
PROVIDE FAXED COPY OF MISSING HEALTH CERTIFICATES FOR MASTER, [name withheld].
Documentation
Issued 11 October 1995
Resolved
PROVIDE FLAG STATE DOCUMENTATION SHOWING APPROVAL WHERE NUMBER OF CREW EXCEEDS THE ALLOWED MANNING LEVEL AS LISTED ON THE SAFETY EQUIPMENT CERTIFICATE._x001C_ SOLAS III
Deck/Cargo
Issued 11 October 1995
Resolved
RENEW VENT SCREENS TO THE MAIN SUPPLY TERMINAL TO THE PUMP ROOM._x001C_ _x001C_ _x001C_ BCH 3.1
Electrical
Issued 21 December 1994
Resolved
THE ELECTRICAL JUNCTION BOX BY CARGO TANK NO 4 IS HOLED AT THE BOTTOM. A TEMPORARY FIBERGLASS HAS BEEN PLACED OVER THE HOLE. CLASS INSPECTED AND REPARIS WILL BE MADE OOB APRIL 95.
Construction/Loadline
Issued 21 December 1994
Resolved
REPAIR NO 1 STARBOARD DOUBLE BOTTOM AIRPIPE. HOLED AT THE TOP TEMP REPAIR MADE WITH FIBERGLASS. CLASS INSPECTED, REPAIRS WILL BE MADE BEFORE THE VESSEL'S ANNUAL INSPECTION OOB APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
A FRACTURE IN WELD AROUND THE LUBE OIL RETURN LINE GOING INTO THE CARGO CONTROL ROOM ON THE STARBOARD SIDE WAS DISCOVERED. CLASS INSPECTED THE CRACK RECOMMENDED TEMPORARY REPAIR MADE. CRACK DRILL STOPPED AND EPOXIED. PERMANENT REPAIRS WILL BE MADE OOB APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
REPAIR CONDUIT TO NO 1 CARGO TANK GAUGE. A TEMPORARY REPAIR HAS BEEN MADE USING FIBERGLASS. CLASS INSPECTED REPAIR PERMANENT REPAIR WILL BE MADE BEFORE ANNUAL SURVEY OOB APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
VESSEL HAS A VRS. THE PIPE TO THE VRS ON THE STARBOARD MANIFOLD WAS NOT PROPERLY MARKED AND WAS MISSING THE PIN. CLASS INSPECTED AND REQUIRED THAT PERMANENT REPAIRS BE MADE BY APRIL 95. VESSEL DID NOT NEED THE VRS FOR THISCARGO DISCHARGE.
Deck/Cargo
Issued 21 December 1994
Resolved
VENT DUCTING INSIDE THE CARGO CONTROL ROOM IS WASTED. CLASS INSPECTED AND REPAIRS WILL BE MADE BEFORE THE ANNUAL SURVEY OOB APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
VENT DUCTING IN THE CARGO PUMP ROOM IS WASTED. A TEMPORARY PATCH OF FIBERGLASS HAS BEEN INSTALLED. CLASS INSPECTED THE VENT. PERMANENT REPAIRS WILL BE MADE OOB APRIL 95.
Lifesaving
Issued 21 December 1994
Resolved
INSTALL A SAFETY GUARD AROUND THE SHAFT FOR THE PORT SUPPLY FAN. CLASS INSPECTED REPAIR WILL BE MADE BY APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
REPLACE VENT SCREENING TO THE CARGO PUMP ROOM. TEMPORARY REPAIRS HAVE BEEN MADE HOWEVER, THE ENTIRE SCREEN NEEDS TO BE MADE. CLASS INSPECTED AND APPROVED TEMP REPAIRS. PERMANENT REPAIRS WILL BE MADE OOB APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
THE CONTAINMENT WAS DAMAGED BY A WAVE. IF THE VENT WERE TO OVERFLOW IT WOULD GO ONTO THE DECK. CLASS INSPECTED AND REQUIRED THAT REPAIRS BE MADE BY APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
PORT SIDE FORWARD OF THE MANIFOLD ONE HYDRAULIC LINE LEADING TO THE VALVE CONTROLLERS IS HOLED. CLASS INSPECTED AND A SOFT PATCH WAS APPLIED. PERMANENT REPAIRS WILL BE MADE BY APRIL 95.
Electrical
Issued 21 December 1994
Resolved
ON THE FOC'SLE THERE IS A ELECTRICAL BOX CONTAINING THREE OUTLETS. THE ENTIRE BOX NEEDS TO BE REPLACED. CLASS INSPECTED AND A TEMPORARY CANVAS COVER WAS PUT OVER THE BOX. PERMANENT REPAIRS WILL BE MADE BEFOR THE VESSELS ANNUAL SURVEY IN APRIL 95.
Deck/Cargo
Issued 21 December 1994
Resolved
A CEMENT DECK PATCH AROUND THE HYDROULIC PIPES WAS FOUND ON THE PORT ANCHORWINCH ON THE FOC'SLE. CLASS INSPEDTED AND REQUIRED PERMANENT REPAIRS BE MADE BY APRIL 95.
Fire Fighting
Issued 7 June 1994
Resolved
FOUND 8 FIRE HOSES THAT HAD NOUMORUS LEAKS IN THEM ON THE VESSEL FORMOSA ONE. SOLAS CHAPTER II-2 PART A REGULATION 4-7.4.1
Lifesaving
Issued 7 June 1994
Resolved
FOUND PORT SIDE LIFE BOAT ENGINE WOULD NOT START. SOLAS CHAPTER II-2 REGULATION 41-6.3_x001C_
Fire Fighting
Issued 7 June 1994
Resolved
FOUND THREE SMALL LEAKS IN FIRE MAIN OF THE VSL "FORMOSA ONE". SOLAS CHAPTER II-2 PART A REGULATION 4-1.
Navigation
Issued 14 January 1993
Resolved
UPDATE LIGHT LIST AND COAST PILOT TO MOST CURRENT NOTICE TO MARINERS PRIOR TO NEXT U.S. VOYAGE.
Fire Fighting
Issued 14 January 1993
Resolved
INSTALL FIXED FIREFIGHTING SYSTEM IN VESSEL'S PAINT LOCKER PRIOR TO NEXT U.S. VOYAGE.
Deck/Cargo
Issued 14 January 1993
Resolved
REPLACE PUMP ROOM VENT FLAME SCREEN PRIOR TO NEXT U.S. VOYAGE.
Accommodation/Occupational Safety
Issued 16 November 1991
Resolved
REMOVE STOWED PAPER AND MATTRESSES FROM ELECTRICAL EQUIPMENT ROOM NEXT TO_x001C_ MASTER'S ROOM.
Electrical
Issued 16 November 1991
Resolved
REPLACE MISSING BOLTS FROM EXPLOSION PROOF LIGHT FIXTURES IN CARGO_x001C_ PUMP ROOM.
Documentation
Issued 13 December 1987
Resolved
PROVIDE ON BOARD IOPP FORM A SUPPLEMENT NO. 182. UNTIL THIS IS DONE, THE ABS SURVEY ANNUAL IOPP SURVEY DATED 7FEB87 IS CONSIDERED ADEQUATE.
Documentation
Issued 9 April 1987
Resolved
OBTAIN CERTIFICATE OF FITNESS REFERENCING MEPC 20(22); SUBMIT COPY OF CER- TIFICATE OF FITNESS TO COMANDANT (G-MTH-1) AND OBTAIN NEW SUBCHAPTER "O" ENDORSEMENT.
Documentation
Issued 9 April 1987
Resolved
PRIOR TO LOADING ANNEX II NLS'S, PLACE CARGO RECORD BOOK ON BOARD.
Unknown
Issued 6 April 1987
Resolved
PRIOR TO CARRYING CATEGORY A, B, C, OR D BULK CHEMICAL CARGOES IN U. S. WATERS, PROVIDE EVIDENCE OF COMPLIANCE WITH ANNEX II OF MARPOL 73/78 TO THESATISFACTION OF THE COGNIZANT OCMI.
Deck/Cargo
Issued 6 April 1987
Resolved
VESSEL PROHIBITED CARRIAGE OF GRADE C AND D OIL PRODUCTS AS DEFINED BY MARPOL 73/78 ANNEX I IN U.S. WATERS DUE TO ABSENCE OF INERT GAS GENERATOR.
Fire Fighting
Issued 24 July 1985
Resolved
PROVIDE ONE ADDITIONAL FIREMAN'S OUTFIT FOR A TOTAL OF FOUR.
Deck/Cargo
Issued 24 July 1985
Resolved
PROVIDE COAST GUARD MARINE INSPECTION OFFICE, HOUSTON WITH A COPY OF THE VESSEL'S BUILDING CONTRACT FOR DETERMINATION OF IGS REQUIREMENTS AS PER 46 CODE OF FEDERAL REGULATIONS 32.53. IF THE VESSEL'S CONTRACT DATE WAS AFTER1 JUN 79 IGS MUST BE INSTALLED PRIOR TO CARRIAGE OF GRADE "C" OR "D" CARGO.
Documentation
Issued 24 July 1985
Resolved
PROVIDE A COPY OF 46 CODE OF FEDERAL REGULATIONS PARTS 1-40.
Documentation
Issued 24 July 1985
Resolved
PROVIDE A COPY OF 46 CODE OF FEDERAL REGULATIONS PARTS 140-155.
Fire Fighting
Issued 24 July 1985
Resolved
PROVIDE ONE ADDITIONAL SELF-CONTAINED BREATHING APPARATUS FOR A TOTAL OF SEVEN. THREE FOR PERSONAL PROTECTION SUITS AND FOUR FOR FIREMAN'S OUTFITS.