Records from 1982 to 2018. Most recent: inspection, 15 November 2018.
Inspection history · 56
15 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6616313
25 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132653
27 June 2012
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4358659
25 July 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4094087
11 July 2011
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4072793
1 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3519600
8 November 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360646
14 May 2008
Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3206095
26 March 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3171878
14 November 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3164681
11 April 2007
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2905869
12 July 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2813831
22 May 2006
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2656001
13 July 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2424453
19 November 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2244291
4 November 2004
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2234738
16 April 2004
Re-Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2045199
9 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1840642
15 April 2002
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1600904
28 November 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076267
12 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466797
21 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215261
15 June 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458767
12 May 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432328
7 June 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808694
15 April 1999
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469264
24 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799506
12 May 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459418
2 May 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443859
26 April 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456361
16 February 1996
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878344
11 February 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 162754
12 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409320
22 July 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412674
14 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64094
22 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440724
27 July 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422171
22 April 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948519
19 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951838
2 January 1992
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254351
3 September 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938786
27 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250396
28 August 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899654
6 February 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216842
7 November 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1333751
18 September 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203773
4 October 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886881
30 March 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342718
5 October 1987
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1016891
15 October 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010902
15 October 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013544
18 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999412
8 November 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992173
7 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281093
6 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281894
30 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271804
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (air motor)
Issued 11 July 2011
Resolved
Replace missing covers on port and starboard transmissions.
Due 25 July 2011
Resolved 25 July 2011
Resolution: New covers were made for each of the transmissions.
Engineering › Fuel Oil Service System › Valve
Issued 11 July 2011
Resolved
Permanently mount port fuel shutoff reach rod.
Condition: Improper Installation
Due 25 July 2011
Resolved 25 July 2011
Resolution: The fuel shutoff reach rod has been screwed into the valve handle.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 11 July 2011
Resolved
Replace ground detection meter.
Condition: Improper/Lack of Maintenance
Due 25 July 2011
Resolved 25 July 2011
Resolution: A new ground detection meter has been provided.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 11 July 2011
Resolved
Provide overcurrent protection on port generator.
Condition: Improper/Lack of Maintenance
Due 25 July 2011
Resolved 25 July 2011
Resolution: The crew successfully proved overcurrent protection on the port generator.
Electrical › Electric Generation Source (service) › Switch
Issued 11 July 2011
Resolved
Provide generator interlock to prevent simultaneously being connected to switchboard.
Condition: Improper Installation
Due 25 July 2011
Resolved 28 June 2012
Resolution: Visually verified generator interlock installed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 1 July 2009
Resolved
Provide securing latch on oven, fridge, and freezer door
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 7 July 2009
Resolution: Received receipt of new latches
Accommodation/Occupational Safety › Ventilation › General
Issued 1 July 2009
Resolved
Replace oven range hood
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 7 July 2009
Resolution: Received receipt of new range hood
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 1 July 2009
Resolved
Provide receipt for the exchange of two (02) fire extinguishers with proper label
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2009
Resolved 1 July 2009
Resolution: Received receipt of two (02) new fire extinguishers.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 July 2006
Resolved
Provide emergency lighting inside of crew berthing and engine room escape scuttle.
Due 19 July 2006
Resolved 13 July 2006
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2006
Resolved
Port generator armature saturated with oil and grime. Clean as necessary.
Due 19 July 2006
Resolved 12 July 2006
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 9 July 2003
Resolved
PROVIDE ONE DIAMOND DAY SHAPE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 10 July 2003
Construction/Loadline › Structures › Door
Issued 9 July 2003
Resolved
ADJUST DOGS ON GALLEY WATER TIGHT DOOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 10 July 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 9 July 2003
Resolved
SECURE REFRIGERATOR IN GALLEY. LEGACY COMPONENT DESC: REFRIGERATOR
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 10 July 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 9 July 2003
Resolved
REMOVE LINT FROM BEHIND CLOTHES DRYER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 10 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 July 2003
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON MAIN ENGINE AND GENERATOR FUEL OIL FLEXIBLE HOSES WERE TOUCHING OTHER COMPONENTS. LEGACY COMPONENT DESC: FLEXIBLE HOSES
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 10 July 2003
Electrical
Issued 9 July 2003
Resolved
CLEAN BATTERY BOXES FOR BOTH GENERATORS. LEGACY COMPONENT DESC: BATTER BOXES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 10 July 2003
Lifesaving › Buoyant Apparatus
Issued 9 July 2003
Resolved
RECONFIGURE LIFE FLOAT PAINTER FOR A STRAIGHT PULL ON WEAK LINK. LEGACY COMPONENT DESC: LIFE FLOATS
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 10 July 2003
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 15 April 2002
Resolved
CURRENT NAV RULES NOT PROVIDED.
Condition: Unknown
Due 15 April 2002
Resolved 15 April 2002
Fire Fighting › Fire Pumps
Issued 15 April 2002
Resolved
FIRE PUMP GUAGE INCREMENTS TOO GREAT FOR DISCHARGE PRESSURE OF PUMP. GUAGE TO BE REPLACED WITH A MAXIMUM PRESSURE READING OF 150 PSI.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 15 April 2002
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 April 2002
Resolved
PORT GEN AND STBD MAIN ENGINE NOT PROVIDED WITH SUFFICIENT EXHAUST LAGGING.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 15 April 2002
Engineering › Fuel Oil Service System
Issued 15 April 2002
Resolved
METALLIC PLUGS NOT PROVIDE FOR ALL FUEL FILTER DRAINS. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 15 April 2002
Fire Fighting
Issued 12 September 2001
Resolved
INSTALL FIXED FIREFIGHTING IN PAINT LOCKER IAW 46CFR181.400(b)(3) TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Unknown
Issued 12 September 2001
Resolved
PROVIDE AND INSTALL LAGGING FOR THE STARBOARD MAIN ENGINE EXHAUST PIPING TOTHE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Construction/Loadline
Issued 12 September 2001
Resolved
INSTALL BILGE LEVEL ALARM FOR GENERATOR ROOM WITH AUDIBLE AND SEPERATE VISUAL ALARM AT THE OPERATING STATION TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Deck/Cargo
Issued 15 April 1999
Resolved
Replace flammable tank vent screens (09). Screens clogged with paint.
Condition: Unknown
Due 30 April 1999
Resolved 5 May 1999
Lifesaving
Issued 15 April 1999
Resolved
Provide brightly colored, portable watertight container marked "Distress Signals" for stowage of signaling devices. Current container is not labledand is olive drab in color.
Condition: Unknown
Due 30 April 1999
Resolved 5 May 1999
Navigation
Issued 15 April 1999
Resolved
Repair, provide rudder stop (port side) so ram does not strike and pass underneath. Replace broken bolt on rudder strut.
Condition: Unknown
Due 30 April 1999
Resolved 5 May 1999
Navigation
Issued 15 April 1999
Resolved
Provide proper lamp for anchor light and stbd running light. Both lights currently contain glazed household lightbulbs.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Engineering
Issued 15 April 1999
Resolved
Remove paint from pressure vessel label.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Construction/Loadline
Issued 15 April 1999
Resolved
Install bilge alarm in lazarette. Bilge alarm not installed after phase-in date.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Navigation
Issued 15 April 1999
Resolved
Provide current tide and current tables. Tide tables were 1998 ed, current tables were missing.
Condition: Unknown
Due 30 April 1999
Resolved 5 May 1999
Construction/Loadline
Issued 16 February 1996
Resolved
Proceed to Superior ship yard and make permanent repairs to forepeak damageto the satisfaction of the attending marine inspector.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 6 February 1984
Resolved
PROVIDE 3 SEAPAINTERS 100' EACH WITH WEAK LINE ON ALL 3 LIFE FLOATS.
Condition: Unknown
Due 6 February 1984
Resolved 6 February 1984
Unknown
Issued 6 February 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE SHARON FAYE, EN635181.
Condition: Unknown
Due 6 February 1984
Resolved 6 February 1984
Documentation
Issued 6 February 1984
Resolved
PROVIDE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 6 February 1984
Resolved 6 February 1984