Inspection history · 57
2 March 2026
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8318515
6 January 2026
In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8289146
9 December 2025
Re-Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8279634
10 September 2025
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8230779
10 July 2025
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160461
5 March 2025
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072845
9 October 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8016916
10 July 2024
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7954824
9 July 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7955435
23 May 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7917648
5 April 2024
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7881864
10 January 2024
Re-Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7847520
1 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818514
18 October 2023
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810117
18 July 2023
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7745620
6 April 2023
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7662448
30 August 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7547136
18 August 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7536994
22 July 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7513821
16 May 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7452046
23 February 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7390444
14 December 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7367381
16 September 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7314205
22 June 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7232962
8 June 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7221671
20 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7127577
13 January 2021
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7123730
3 December 2020
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105663
23 September 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070242
22 July 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7015301
26 March 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7038424
24 February 2020
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6914743
15 October 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6834623
24 September 2019
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6818988
14 June 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6713855
13 June 2019
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6714216
11 June 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6711208
15 May 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6709322
5 March 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6636387
21 June 2018
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6455133
21 June 2018
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472822
12 March 2018
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6370262
7 December 2017
Hull Examination · Examination of Repairs · Internal Structural Exam · Load Line/Change of Employment
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6318253
31 October 2017
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298288
28 October 2017
In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298454
25 August 2017
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6251493
6 July 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6209034
11 May 2017
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6143589
17 February 2017
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6090124
10 November 2016
Re-Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038741
3 October 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6017345
18 August 2016
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5975938
6 July 2016
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5931591
8 June 2016
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5906511
14 April 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5853935
25 February 2016
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5822042
22 January 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5801972
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2026
Resolved
Fixed fire extinguishing systems must be checked as noted in Table 71.25-20(a)(2). During the annual inspection of the fixed CO2 system (04) flexible connections were identified with damage caused by twisting the hoses and/or damage to the factory connection. Renew the four damaged hoses identified and submit documentation attesting to their renewal prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2026
Resolution: Resolved same day to the satisfaction of the attending Marine Inspector. Flexible connections were renewed sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2026
Resolved
An additional (06) flexible connections related to the vessel's CO2 system were identified with damage requiring renewal. Vessel shall submit documentation attesting to renewal of the remaining hoses and statement attesting a complete evaluation of all remaining flexible connections on board the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2026
Resolved 10 April 2026
Resolution: Objective photographic evidence of correction provided by operator.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2026
Resolved
During the annual test of the fixed CO2 system walk-through of the engine room one of the bilge discharge nozzles was discovered missing. Vessel to replace the discharge nozzle within the time frame prescribed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2026
Resolved 4 March 2026
Resolution: Nozzle replaced immediately after the inspection with a replacement in stock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2026
Resolved
During the annual test of the fixed CO2 system the timer
delay activated at 24 seconds on the bench test and over 1 minute 15 seconds during the functional test. Owner shall submit sufficient documentation from the operating manual of the CO2 system or another acceptable source attesting to the rated setting of the timer delay and any information outlining override capability of the system that is available to deliver agent on demand.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2026
Resolved 17 March 2026
Resolution: Attestation by operator of satisfactory testing of time delays received.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 March 2025
Resolved
Where mechanical ventilation is provided for spaces which are protected by a carbon dioxide extinguishing system, provisions shall be mad so that the ventilation system is automatically shut down with the operation of the system to that space. Fire damper on main deck Brooklyn side did not fully close.
46CFR 76.15-35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2025
Resolved
Pressure switch for installed fire extinguishing system in EDG room not working as designed.
46 CFR 76.05-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 5 March 2025
Resolved
Staten Island End on Brooklyn Side loading door not closing fully.
46 CFR 78.17-33
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 28 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 April 2024
Resolved
Spaces which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on board while the vessel...shall be fitted with an approved audible alarm...so arranged as to sound during the 20 seconds delay period prior to the discharge of carbon dioxide into the space. The time delay operated beyong 60 seconds on a first test and not satisfactory on a second test. Provide a CO2 time deplay to operate per regulation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2024
Resolved 8 April 2024
Resolution: The time delay was tested to 28 seconds.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 April 2024
Resolved
In all ventilation system, manually operated dampers or other suitable means shall be provided in accessible locations...
Vessel personnel were unable to manually operate fire dampers in passageway leading to the engine room. Rectify and demonstrate proper operation of fire dampers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2024
Resolution: Proper operation of the fire damper was witnessed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 January 2024
Resolved
NYE-Brooklyn side main deck and Saloon deck has water leaking from overhead out/near light fixtures and life jacket stowage aarea is full of water causing an electrical & personel haz. must investigate and prove water tightness to CGMI.
705: 7 days
Action required: 705 - Other - as specified
Due 17 January 2024
Resolved 5 April 2024
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 February 2022
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided. Make the following ventilation closures for the Voith Spaces in way of the rescue boats operational: New York End, Brooklyn Side and Staten Island End, NJ Side to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 24 February 2022
Resolution: Found closures operational during def check.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 23 February 2022
Resolved
Vents extending above the freeboard deck from fuel oil and other tanks must be at least schedule 40 in wall thickness. Crop and renew wasted boiler condensate vent pipe prior to 30 April 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 24 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 September 2019
Resolved
The ventilation dampers on the hurricane deck are all painted over and you are not able to read which handle controls which zone and in addition there is no way to know if they are open or closed. The intent is to provide such markings as are necessary for the guidance of the persons on board in case of emergency.
(May be cleared at the next quarterly 01 December 2019)
Action required: 705 - Other - as specified
Due 1 December 2019
Resolved 2 October 2020
Resolution: PAINT REMOVED
Fire Fighting › Fire Main › Condition
Issued 10 November 2016
Resolved
Fire main is cracked in way of the 2nd flange on the discharge side of the fire pump; crew has installed a temporary repair/patch. Conduct permanent and proper repairs to the satisfaction of USCG and provide a class report.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2016
Resolved 10 November 2016
Resolution: Vessel made proper repair (V/W fillet joint) and proved proper operation.
Engineering › Steering Gear System › Actuator
Issued 3 October 2016
Resolved
Provide written causal analysis, make repairs, and provide technical report of repairs made to Voith steering system/controls. Senior Port Captain shall attest to the completion of repairs and testing and provide written confirmation to this office.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016