PROSPECT SEAHORSE

PROSPECT SEAHORSE is a 1982 offshore supply vessel. The Coast Guard has recorded 13 inspections since 1982, most recently in March 1994, along with 6 deficiencies.

Records from 1982 to 1994. Most recent: inspection, 9 March 1994.

Built
1982
Last inspected
9 March 1994
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8127488 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-53796

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (1982–1994)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)164.0 ft × 40.0 ft × 13.2 ft
Registered tonnagegross 290 / net 197
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUDSON SHIPBUILDERS INC · PASCAGOULA MS, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 22 July 1986
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it290 - Regulatory (Subpart C or D), Gross Ton
197 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

9 March 1994 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 854891
22 August 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936818
10 August 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905871
3 July 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 927220
14 September 1989 Examination of Repairs · Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 997124
8 July 1988 MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036768
8 July 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341596
14 August 1987 Drydock Extension · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311303
23 September 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011430
16 August 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989065
11 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974418
8 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966115
8 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274305

Deficiency record · 6

Construction/Loadline
Issued 14 September 1989 Resolved
PLUG BULKHEAD ABOVE WATER TIGHT DOOR AT THE ENGINE ROOM.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Navigation
Issued 14 September 1989 Resolved
REPAIR CHANNEL 22 ON THE FORWARD VHF RADIO.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Engineering
Issued 14 September 1989 Resolved
REPAIR STARBOARD MAIN ENGINE REMOTE SHUTDOWN.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Engineering
Issued 14 September 1989 Resolved
REPAIR ALL MAIN ENGINE, BOW THRUSTER, AND FIRE PUMP GAUGES IN THE WHEEL HOUSE.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Unknown
Issued 11 July 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V PBR 371, O.N. 646671. THE BELOW LISTED ITEM IS TO BE COMPLIED WITH BY 11AUG84.
Condition: Unknown
Due 11 July 1984
Resolved 11 July 1984
Unknown
Issued 11 July 1984 Resolved
PROVIDE ORIGINAL OR A CERTIFIED COPY OF THE VESSELS STABILITY LETTER AND POST IT IN WHEELHOUSE.
Condition: Unknown
Due 11 July 1984
Resolved 11 July 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.