MAURY USCG vessel records Sign in
← All vessels

SUPER DAUNTY VII *

SUPER DAUNTY VII * is a 1981 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in September 1997, along with 44 deficiencies.

Records from 1985 to 1997. Most recent: inspection, 9 September 1997.

Built
1981
Last inspected
9 September 1997
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTN4047
Flag
UNITED STATES
—
Maury page id
psix-53801

Inspections, by type

…with no type recorded7
Years with a record 13 calendar years (1985–1997)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.6 ft × 21.2 ft × 6.1 ft
Registered tonnagegross 90 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS · STUART, FL, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationNo Operation - PM · issued 5 May 1993
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX4231MMSI not assigned · expired · compulsorily equipped · granted 24 April 1997, cancelled 24 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

9 September 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1122053
9 August 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 149628
3 April 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1093697
8 October 1996 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 838617
6 June 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1084323
27 October 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876273
12 October 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189690
25 April 1995 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867202
29 November 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867674
18 October 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 869435
17 December 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1160379
24 November 1993 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 848415
25 October 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 827062
18 May 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138226
2 April 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133879
2 February 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136667
12 November 1992 Drydock Extension · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 825876
12 November 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954551
18 June 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255524
16 November 1990 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918345
20 April 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905793
8 March 1990 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909905
28 February 1989 Deficiency Check · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041478
30 March 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344356
18 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344358
28 May 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335522
11 April 1987 COI Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1308231
22 May 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991652
13 March 1986 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 998330
29 October 1985 Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 993296
18 October 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 988469
25 September 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1300111
16 May 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 979674
26 April 1985 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1287673

Deficiency record · 44

Construction/Loadline
Issued 8 October 1996 Resolved
PRIOR TO THE NEXT SCHEDULED DRYDOCK BUT NOT LATER THAN 30APR97, PROVIDE A WRITTEN REPAIR PROPOSAL FOR THE #1 STARBOARD FRAME CAP WHERE DELAMINATING AND SEPERATING FROM THE MAIN FRAME.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
PROVIDE A BRIGHTLY COLORED, WATERTIGHT, PROPERLY STENCILED DISTRESS SIGNAL CONTAINER.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Fire Fighting
Issued 8 October 1996 Resolved
PROVIDE A SPANNER WRENCH FOR THE FIRE MAIN STATIONS.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Electrical
Issued 8 October 1996 Resolved
INSTALL A LIGHT SWITCH PROTECTIVE COVER OVER THE LAZARETTE LIGHT SWITCH.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Electrical
Issued 8 October 1996 Resolved
PROPERLY WIRE CRIMP ALL ELECTRICAL CONNECTIONS TO THE SHOWER SUMP PUMP LOCATED IN THE TANK ROOM.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Lifesaving
Issued 8 October 1996 Resolved
PRIOR TO PLACING VESSEL IN SPRING SERVICE, MAKE THE VESSEL AVAILABLE FOR ANINTERNAL UNDERWAY EXAMINATION AND CONDUCT EMERGENCY DRILLS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
RENEW ALL PADDLES AND RETROREFLECTIVE MATERIAL TO THE VESSEL'S LIFE FLOATS AS NECESSARY AND DISCUSSED.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Engineering
Issued 12 October 1995 Resolved
LABEL THE EMRGENCY FUEL SHUTOFFS FOR THE STARBOARD MDE AND SSG NO LATER THAN 26OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Lifesaving
Issued 12 October 1995 Resolved
PROPERLY STENCIL VESSEL NAME AND PERSON CAPACITY ON ALL FOUR LIFEFLOATS NO LATER THAN 26OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Electrical
Issued 12 October 1995 Resolved
REPLACE THE BROKEN LIGHT FIXTURE OR PROPERLY DEAD END THE LOOSE WIRES ON THE STARBOARD SIDE OF THE STATEROOM NO LATER THAN 26OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Construction/Loadline
Issued 12 October 1995 Resolved
PRIOR TO PLACING THE VESSEL IN SPRING SERVICE, MAKE VESSEL AVAILABLE FOR UNDERWAY INTERNAL EXAMINATION AND ANNUAL DRILLS BY AN ATTENDING COAST GUARDMARINE INSPECTOR NOT LATER THAN 15 MAY 1996.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Navigation
Issued 12 October 1995 Resolved
RENEW ALL HYDRAULIC LINE COUPLINGS TO ANCHOR WINCH AND STEERING GEAR NO LATER THAN 26OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Lifesaving
Issued 12 October 1995 Resolved
PROPERLY LASH THE LIFEFLOAT PADDLES TO THE LIFEFLOATS NO LATER THAN 26OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Construction/Loadline
Issued 25 April 1995 Resolved
RENEW SPLIT FRAM IN FORE PEAK STARBOARD BOW. REPAIRS ARE TO BE MADE TO THESATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR ON OR BEFORE 25 MAY 1995.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Lifesaving
Issued 18 October 1994 Resolved
PRIOR TO OPERATION AND NO LATER THAN 18 NOVEMBER 94, PROVIDE TWO (2) ADDITIONAL 25-PERSON LIFEFLOATS.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Navigation
Issued 18 October 1994 Resolved
PROVE PROPER OPERATION OF FURUNO DEPTH SOUNDER AND RADAR, OR REMOVE FROM VESSEL NO LATER THAN 18 NOVEMBER 94.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Construction/Loadline
Issued 25 October 1993 Resolved
ON OR BEFORE NEXT DRYDOCK EXAMINATION BUT NO LATER THAN 30 APRIL 1995, APPLY DRAFT MARKS OR LOADING MARK IN ACCORDANCE WITH VESSEL'S CURRENT STABILITY LETTER DATED 01 JUNE 1981.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Lifesaving
Issued 25 October 1993 Resolved
PRIOR TO OPERATION AND NO LATER THAN 25 NOVEMBER 1993 INSTALL FLOAT FREE LINK ON LIFE FLOAT PAINTER. INSTALLATION SHALL BE TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Lifesaving
Issued 25 October 1993 Resolved
PRIOR TO OPERATING ON OCEAN ROUTE AND NO LATER THAN 25 NOVEMBER 1993 REPLACE OUTDATED CHEMLITE'S ON LIFE PRESERVERS.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Documentation
Issued 18 May 1993 Resolved
PROVIDE AND POST COPY OF VESSEL STABILITY LETTER.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Engineering
Issued 18 May 1993 Resolved
MAKE PERMANENT REPAIR TO DUCT TAPED AREA ON STBD ENGINE OUTBOARD EXHAUST PIPE.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 18 May 1993 Resolved
LABEL FIRE HOSE STORAGE AREA.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Accommodation/Occupational Safety
Issued 18 May 1993 Resolved
LABEL ENGINE ROOM ESCAPE HATCH.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Lifesaving
Issued 18 May 1993 Resolved
PROVIDE TWO ADDITIONAL WATER LIGHTS. ONE FOR LIFE FLOATS AND ONE FOR RING BUOY.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Lifesaving
Issued 18 May 1993 Resolved
PROVIDE TWO ADDITIONAL RING BUOYS. ONE WITH 60' OF LINE ATTACHED AND PROPERLY MOUNT SAME.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 18 May 1993 Resolved
PROVE PROPER OPERATION OF FWD CHAIN LOCKER COMPARTMENT SCUTTLE AND_x001C_ LAZARETTE SCUTTLE SO AS TO PROVE WATER TIGHT.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Engineering
Issued 18 May 1993 Resolved
INSTALL PROPER FLAME SCREENS ON ALL THREE FUEL OIL TANK VENT PIPES.
Condition: Unknown
Due 18 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 12 November 1992 Resolved
DRYDOCK EXAM DUE DATE EXTENDED TO NOT LATER THAN 30 JUN 93. THE VESSEL IS TO BE PRESENTED FOR A DRYDOCK EXAM ON OR BEFORE 30 JUN 93.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Documentation
Issued 12 November 1991 Resolved
PROVIDE TO [name withheld] OF STABILTY LETTER AND POST SAME ON VESSEL.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Unknown
Issued 16 November 1990 Resolved
CONTACT THIS OFFICER IN CHARGE OF MARINE OF MARINE INSPECTION, MIAMI, FL. AT [phone withheld] OF 454 AND ARRANGE FOR EXAMINATION OF THE VESSEL PRIOR TOCARRYING PASSENGERS IN HIS ZONE.
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Electrical
Issued 18 March 1988 Resolved
PROVIDE GROUND FAULT PROTECTION FOR 110V AC ELECTRICAL SYSTEM
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Documentation
Issued 18 March 1988 Resolved
REMARK NAME ON VESSEL USING BLOCK LETTERING AT NEXT DRYDOCKING BUT NOT LATER THAN 31 DEC 88. SCRIPT "SUPER" IS NOT PERMISSIBLE.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Construction/Loadline
Issued 11 April 1987 Resolved
PROVIDE HATCH SECURING DEVICE FOR LAZARRETTE HATCH COVER.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Lifesaving
Issued 11 April 1987 Resolved
PROVIDE 6 ORANGE SMOKE SIGNALS
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Lifesaving
Issued 11 April 1987 Resolved
PROVIDE 7 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Electrical
Issued 11 April 1987 Resolved
REPLACE FLUORESCENT AND QUARTZ LIGHTS WITH APPROVED MARINE TYPE LIGHTS.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Accommodation/Occupational Safety
Issued 11 April 1987 Resolved
PROVIDE SAFETY GUARD FOR INTAKE FAN AT REAR OF ENGINE ROOM.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Lifesaving
Issued 11 April 1987 Resolved
PROVIDE 1 RING LIFE BOUY.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Construction/Loadline
Issued 29 October 1985 Resolved
MAKE ENGINE SPACE AVAILABLE FOR COMPLETE DAMAGE SURVEY. THIS SHALL INCLUDE,BUT NOT LIMITED TO REMOVAL OF FITTINGS, ENGINES, WIRING, INSULATION, ETC.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Construction/Loadline
Issued 29 October 1985 Resolved
MAKE PERMAMENT REPAIRS TO FIRE DAMAGED ITEMS TO ACHIEVE A RENEWAL IN KIND CONDITION.
Condition: Unknown
Due 29 October 1985
Resolved 29 October 1985
Fire Fighting
Issued 26 April 1985 Resolved
PROVIDE HAND OPERATED FIRE AND BILGE PUMP WITH HOSE.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Engineering
Issued 26 April 1985 Resolved
MAKE MAIN ENGINES AND GENERATOR AVAILABLE FOR TESTING OF ALARMS AND CUTOUTS
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Navigation
Issued 26 April 1985 Resolved
PROVIDE STERN LIGHT.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Lifesaving
Issued 26 April 1985 Resolved
ATTACH RETROREFLECTIVE TAPE ON LIFE FLOATS.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985

Ownership record