Records from 1982 to 2023. Most recent: inspection, 7 March 2023.
Inspection history · 55
7 March 2023
Annual Inspection · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7646744
8 December 2021
Deficiency Check · MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7364921
14 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7312183
29 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7132977
14 December 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7111392
21 October 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6838853
27 February 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6633701
4 December 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6592197
23 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6520414
25 September 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6274416
10 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6236442
31 March 2016
Internal Structural Exam · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5844539
20 June 2012
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4351258
24 February 2011
Internal Structural Exam · MTSA Verification · Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3951617
18 January 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3928546
11 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3925102
9 March 2010
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3693220
23 December 2008
Internal Structural Exam · Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3384016
19 March 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3171900
26 December 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3128054
23 March 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2893376
18 July 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2717159
4 April 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2621064
25 April 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2339532
22 October 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075415
22 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 164005
24 March 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461264
24 September 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473363
16 September 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392979
30 September 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470701
9 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774381
9 May 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458418
27 November 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454382
28 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 74254
20 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419514
5 October 1995
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451008
16 March 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448644
23 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172557
9 November 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377293
14 October 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419169
4 December 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470358
10 April 1992
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949779
12 December 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 948030
17 October 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 938377
20 February 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 911814
27 December 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1235413
20 April 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916342
31 October 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1325643
15 November 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893765
2 November 1987
MARPOL Annex II Examination · Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1020787
30 September 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011923
10 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010403
18 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281329
10 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280511
11 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276568
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2023
No resolution recorded
The Vessel shall complete the list of defs issued & emailed to the vsl's Port Engr on 14 Mar 23, work list was added to MISLE-Deficiencies-Documents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2021
Resolved
Vessels in ocean, coastwise, or Great Lakes service, except unmanned barges, shall be fitted with anchors. chains, and hawsers in general agreement with the Standards established by the American Bureau of Shipping, see Subpart 90.35 of this subchapter. During the lowering of both port and stbd anchors, the flukes on bothe sides were seized. Vessel is required to make flukes free of any binding.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2021
Resolution: Operated anchor windless to check for free movement of the anchor flukes, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2021
Resolved
Each vessel not on an international voyage with an installation of steering gear contracted for before June 9, 1995, and each vessel on an international voyage with such an installation contracted for before September 1, 1984, may meet either the requirements of this subpart or those in effect on the date of the installation. During testing of vessels steering system, stbd rudder post packing was too tight causing the system to skip. Vessel needs to loosen rudder post packing to eliminate damage to vessels steering system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2021
Resolution: Operated the steering system to check for free movement of the steering rudder post and checked for leaks, test sat
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 September 2021
Resolved
Aft bulkhead of port chain locker wasted. Insert as needed to good metal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2021
Resolution: Bulk head was inserted.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 14 September 2021
Resolved
Stbd rap overhead (main deck holed) Insert to good metal.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2021
Resolution: Deck was inserted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 September 2021
Resolved
Liquid mud tank covers need renewing port aft and stbd fwd.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2021
Resolution: New hatch rings were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2021
Resolved
Cylinders shall be designed for a bursting pressure of not less than 4 times the maximum allowable working pressure.
Vessel’s seal on port hydraulic steering cylinder is actively leaking and unable to meet the burst pressure requirements. 46CFR96.03-1
46CFR 58.30-30 (c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel sent steering gear components off for repair, upon return conducted a steering test for attending Coast Guard inspectors, no leaks were observed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 December 2020
Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. The height of the rails or bulwarks shall be at least 39.5 inches from the deck.3
Vessel’s has turnbuckles for a rail course, the highest of which are less than 39.5 inches above deck height. Vessel shall reinstall turn buckles to ensure that the highest course is 39.5 inches above the deck, the lowest shall be not more than 9 inches, and that there is no more than 15 inches between courses. 46 CFR 92.25-5 (a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel welded chains to appropriate heights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 December 2020
Resolved
All vessels shall be provided with a satisfactory bilge pumping plant.
Vessel has soft patch on bilge piping near isolation valve for overboard discharge. Bilge piping shall be
repaired at next dry docking. 46 CFR 96.03-1
46 CFR 56.50-50 (a) (1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 October 2021
Resolution: Cropped and renewed, SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 December 2020
Resolved
Ventilator openings shall be provided with efficient weathertight closing appliances.
05 vents on the starboard bow, connected to the sink, shower, and toilet draining system were significantly wasted away with large holes in their bends, preventing them from being made weathertight. 46 CFR 92.01-5 46 CFR 42.15-45 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 October 2021
Resolution: Cropped and renewed, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 December 2020
Resolved
Each generator must meet the applicable requirements for the construction and testing section in 4-8-3 of the ABS Steel Vessel Rules.
Vessel’s forward generator cooling line is actively leaking water. 46 CFR 90.25-1
46 CFR 111.12-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel cropped and renewed damaged pipe elbow. Upon running the generator no leaks were observed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 December 2020
Resolved
The grab line shall be 3/8 inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds.
02 life rings had grab lines that were significantly frayed and wasted and require replacements. 46 CFR 94.43-5 (a)
46 CFR 160.050-3 (c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel replaced all old life rings with new life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 December 2020
Resolved
Each life preserver carried on a vessel engaged in ocean or coastwise service must have a personal flotation device light.
01 PFD in the engine room had an expired chemical light on it. Vessel must replace light. 46 CFR 94.42-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel purchased and attached new light for engine room life jacket.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2020
Resolved
Each firehose on each hydrant must have a combination of solid stream and water spray firehose nozzle that is approved under 162.027. Due to lack of maintenance firehose nozzle didn't produce a suitable water spray. 46 CFR 95.10-10 (i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: Vessel identified damaged gasket in fire nozzle, gasket was replaced, vessel demonstrated satisfactory operation of the nozzle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2020
Resolved
Fire hydrants shall be of sufficient number and so located that any part of the vessel accessible to persons on board while the vessel is being navigated and all cargo holds may be reached with at least 2 streams of water from separate outlets.
The port side fire hydrant, on the aft main deck, near the superstructure, ruptured while running the fire main. Vessel must effect repairs to the fire hydrant and demonstrate to the satisfaction of the attending Coast Guard inspector that the repair is sufficient to withstand normal fire main pressures. 46CFR95.10-10(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2021
Resolution: Vessel repaired hydrant and conducted a pressure test to the satisfaction of the attending Coast Guard Inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2019
Resolved
VESSEL'S MACHINERY SHALL BE KEPT IN SATISIFACTORY CONDITION. STARBOARD MAIN DIESEL ENGINE WAS LOSING EXCESS AMOUNTS OF OIL. MAKE REPAIR TO STARBOARD MAIN DIESEL ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Third party mechanic corrected deficiency. Witnessed satisfactory test of engine. No
oil leaking.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 October 2019
Resolved
FIRE HAZARDS SHALL BE MINIMIZED. IDENTIFIED EXCESS OIL FOUND IN THE BILGES. PROVIDE PROPER DISPOSAL OF EXCESS OIL IN BILGES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Bilges pumped and cleaned by third party
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2019
Resolved
FIRE HOSE NOZZLES SHALL BE KEPT IN GOOD WORKING ORDER. FIRE HOSE NOZZLES WERE INOPERABLE. PROVIDE PROPER OPERATION OF ALL FIRE HOSE NOZZLES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: USCG witnessed fire nozzles working properly
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 October 2019
Resolved
REPLACED WASTED WATERTIGHT GASKETS AND ADJUST WATERTIGHT DOORS TO ENSURE WATERTIGHTNESS. ENSURE FIRE DAMPNERS ARE OF APPROPRIATE WEATHERTIGHT GASKET MATERIAL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: CG witnessed adjustment to watertight doors and new gaskets were in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2019
Resolved
VESSEL WAS UNABLE TO PREFORM TEST OF GENERATOR OVERSPEED DEVICE. PROVE PROPER OPERATION OF GENERATOR OVERSPEEDS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Over speed device replaced on generator and CG inspector witnessed satisfactory test of generator overspeed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2019
Resolved
BILGE ALARM PANEL IN THE PILOT HOUSE WAS NOT LABELING ACCURATELY TO REFLECT BILGE ALARM LOCATION. PROVIDE ACCURATE LABELING FOR BILGE ALARM PANEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2019
Resolution: CG inspector witnessed test of bilge alarms and panel was labeled correctly.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 September 2017
Resolved
46CFR 97.15-35 No crew on board to conduct Security and ships drills.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2017
Resolved 29 August 2018
Resolution: Ran satisfactory drills
Engineering › Steering Gear System › Rudder Stock
Issued 25 September 2017
Resolved
46CFR58.25-50B: Missing Rudder post on portside
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 29 August 2018
Resolution: Rudder stop installed. Satisfactory test of steering gear
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 May 2016
Resolved
Port & STBD liferafts need annual inspection prior to sail.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2017
Resolution: They were inspected by a third party.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 2 May 2016
Resolved
Port Main overspeed needs to be tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 May 2016
Resolution: Retested the overspeed and cut off at 1900 RPM. Test was sat.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 24 February 2011
Resolved
Vessel to install a NAVTEX receiver IAW 47 CFR 88.881; vsl is limited to within 100nm of land until resolved.
Action required: 705 - Other - as specified
Due 23 June 2011
Resolved 20 June 2012
Resolution: NAVTEX receiver installed and operating properly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 January 2011
Resolved
Vsl failed to arrange an exam prior to the COI's expiration date. COI expired on 23 Dec 10. Vsl must arrange for a drydock/ hull exam & COI exam in order to be certificated.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 23 March 2011
Resolution: Vessel completd an DD & COI exam on 23 Mar 2011.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 9 March 2010
Resolved
Prove proper operation of ships air receivers safety relief valves in accordance with regulation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 11 March 2010
Resolution: Proved proper operation of relief valves in accordance with regulation.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 23 March 2007
Resolved
Provide approved autmoated test procedures
Action required: 705 - Other - as specified
Resolved 27 March 2007
Fire Fighting › Fire Hoses › Condition
Issued 23 March 2007
Resolved
Replace two worn firehoses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 March 2007
Resolved
Provide approved lifesaving/fire plan
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 27 March 2007
Lifesaving
Issued 24 September 1999
Resolved
DEMONSTRATE COMPLIANCE WITH THE EIGHTH DISTRICT'S U.S. COAST GUARD RESCUE BOAT POLICY.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 30 September 1997
Resolved
RENEW GASKET ON PORT WATER TIGHT DOOR, ENGINE ROOM MAIN DECK AFT.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Engineering
Issued 30 September 1997
Resolved
REPAIR TACHOMETER ON STARBOARD MAIN DIESEL ENGINE AND TEST OVER-SPEED.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Engineering
Issued 30 September 1997
Resolved
AMEND PERIODIC AUTOMATION TEST PROCEDURES ALARM SET POINTS FOR JACKET_x001C_ WATER TEMP, LUBE OIL TEMP AND PRESSURE OR ADJUST SETPOINTS TO "AUTOMATION TEST PROCEDURE" SETTING._x001C_
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 5 October 1995
Resolved
PROVIDE CURRENT COMPASS DEVIATION TABLE._x001C_
Condition: Unknown
Due 16 October 1995
Resolved 13 October 1995
Accommodation/Occupational Safety
Issued 5 October 1995
Resolved
PROVIDE NEW GREASE SCREEN IN GALLEY RANGE HOOD.
Condition: Unknown
Due 16 October 1995
Resolved 13 October 1995
Electrical
Issued 5 October 1995
Resolved
PROVIDE NON-CONDUCTIVE MATS AROUND SWITCHBOARD._x001C_
Condition: Unknown
Due 5 October 1995
Resolved 6 October 1995
Documentation
Issued 5 October 1995
Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM AS IDENTIFIED IN 46 CFR 16.
Condition: Unknown
Due 6 November 1995
Resolved 20 October 1995
Navigation
Issued 5 October 1995
Resolved
PROVIDE NEW EDITION OF LIGHT LIST, LATEST COPIES OF NOTICE TO MARINERS, AND46 CFR 90-139.
Condition: Unknown
Due 16 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 5 October 1995
Resolved
READJUST WATERTIGHT DOOR BETWEEN ENGINEROOM AND STEERING COMPARTMENT.
Condition: Unknown
Due 5 October 1995
Resolved 6 October 1995
Documentation
Issued 5 October 1995
Resolved
POST NEW OIL POLLUTION PLACARDS IN ENGINEROOM.
Condition: Unknown
Due 5 November 1995
Resolved 13 October 1995
Documentation
Issued 9 November 1994
Resolved
SUBMIT FOR APPROVAL THE AUTOMATED ENGINEROOM PROCEDURES.
Condition: Unknown
Due 9 January 1995
Resolved 23 November 1994
Deck/Cargo
Issued 17 October 1991
Resolved
CLEAN, OPEN AND MAKE AVAILABLE FOR INSPECTION ALL DRY BULK TANKS AT NEXT DRYDOCK BUT NLT 30NOV92._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Construction/Loadline
Issued 17 October 1991
Resolved
MAKE OPERABLE BILGE HIGH LEVEL ALARM IN ENGINE ROOM PASSAGEWAY.
Condition: Unknown
Due 17 December 1991
Resolved 12 December 1991
Engineering
Issued 17 October 1991
Resolved
PROPERLY MARK AND HYDROSTATICALLY TEST ALL OIL TRANSFER HOSE IN ACCORDANCE WITH 33 CFR PART 154.500.
Condition: Unknown
Due 17 December 1991
Resolved 12 December 1991
Navigation
Issued 17 October 1991
Resolved
MAKE OPERABLE THE #1 STEERING PUMP LOSS OF POWER ALARM.
Condition: Unknown
Due 17 December 1991
Resolved 12 December 1991
Unknown
Issued 27 December 1990
Resolved
REPAIR AS ORIGINAL TIE-OFF CLEAT ON STBD INFLATABLE LIFERAFT CRADLE
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 27 December 1990
Resolved
PROVIDE NEW CARTRIDGES FOR LINE THROWING GUN
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 27 December 1990
Resolved
INSTALL RUBBER MATTING BEHIND MAIN SWITCHBOARD
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 27 December 1990
Resolved
INSTALL REMOTE SHUTDOWN CONTROLLER FOR CARGO PUMP/GENERATOR PRIME MOVER
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 27 December 1990
Resolved
REPAIR AND CONDUCT OPERATIONAL TEST OF FUEL OIL TRANSFER AND DIRTY OIL PUMPS INCLUDING REMOTE SHUTDOWNS
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 27 December 1990
Resolved
PROVIDE WASTE MANAGEMENT PLAN IN ACCORDANCE WITH 33 CFR PART 151
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Engineering
Issued 31 October 1989
Resolved
PROVIDE NAMEPLATE DATA TO VERIFY THAT ALL FOUR DRY BULK PRESSURE TANKS ARE BUILT IN ACCORDANCE WITH COAST GUARD SPECIFICATIONS AND VERIFY MAWP OF THE PRESSURE VESSELS.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Deck/Cargo
Issued 18 May 1984
Resolved
(CONT. 1) COMPLETED AND PROVIDE ABS CERTIFICATION FOR ANCHOR AND CHAIN.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 18 May 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V PBR/370, O.N. 645894.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Deck/Cargo
Issued 18 May 1984
Resolved
INSTALL THE PORT ANCHOR AND CHAIN BEFORE USING VESSEL IN SERVICE. NOTIFY OFFICER IN CHARGE MARINE INSPECTION, NEW ORLEANS BY LETTER WHEN THIS IS
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 10 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V PBR/370, DN645894.
Condition: Unknown
Due 10 April 1984
Resolved 10 April 1984
Engineering
Issued 10 April 1984
Resolved
MAKE AVAILABLE VESSEL ALARM SYSTEM PROCEDURE AND ALARM SET POINTS PROVIDE ALARM TEST KIT ABOVE ITEM TO BE COMPLETED BY 10JUN84.
Condition: Unknown
Due 10 April 1984
Resolved 10 April 1984