11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 March 2026
No resolution recorded
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. During renewal inspection the MI found: One of the life floats had several cracks in the foam and the grab lines were frayed beyond repair;
Each life float painter line attached to the lead painter line is not of adequate length to allow each life float to be used individually. Vessel is restricted to no more than 3 NM offshore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2026
Resolved
When the exhaust cooling water system is separate from
the engine cooling water system, a suitable warning
visual or audible, must be installed at the operating
station to indicate any reduction in normal water flow
in the exhaust cooling system. Starboard flow meter
signal wires are disconnected.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 17 April 2026
Resolution: Wires witnessed connected and wheel house alarms tested.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 March 2026
Resolved
Each ship transporting more than six passengers for hire
must carry a radio operator who meets the following
requirements: the radio operator must hold a marine
radio operator permit or higher class license. Current
captain does not hold a valid FCC VHF radio operators
permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2026
Resolved 17 April 2026
Resolution: Received satisfactory evidence of Captain attending the required course.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2025
Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hoses suitable for use in fire fighting. Hand operated fire pump only has one hose. Provide proper suction and discharge hoses. 46 CFR 181.10-5 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: New hand operated fire pump was purshased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Main engine battery terminals corroded. Clean all large battery posts. 46 CFR 183.01-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: Battery terminals were cleaned
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Dead end wiring throughout that vessel. Remove all dead end cabling and wires in engine room and behind steering console. Properly terminate at wires and secure wiring and battery boxes from shifting. 46 CFR 183.01-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: All cables were removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Generator battery is located in unsecured plastic box without lid in bilge under generator. Oily water mixture filled half of battery box. Remove oily mixture and clean out battery box. Relocate battery box above bilge as close as practicable to generator. 46 CFR 183.05-20 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: Battery box was replaced and moved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
All wiring shall be run as high as practicable above bilges. Engine room bilge pump wiring and splices lying in oily bilge water. Relocate wiring and splices to be waterproof and as high above bilge water level as possible. 46 CFR 183.05-50 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: Wires were resliced and proerly hung.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Dead end wiring from old generator present hanging under old generator not properly secured inside junction box. Remove entire unused old generator wiring harness and seal bulkhead penetration with fire rated caulking. 46 CFR 183.05-50 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: Old wires removed and sealed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table only on a vessel of not more than 19.8 meters in length and not more than 49 passengers: the pump is permanently mounted; the pump is equipped with a strainer that can be readily inspected and cleaned without removal; a positive shut-off valve is installed at the hull penetration. Permanently mount all automatic bilge pumps with strainers and install shut-off valves at overboard discharge connections. New "T" 46 CFR 182.520 (e) (1-7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: Bilge pump was permanetly mounted with a strainer.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Provide indicator lights for all installed auto-bilge pumps in forepeak, passenger compartment, engine room, and steering gear room. New “T” 46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: New indicators were installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No charts were carried on board and the vessel did not have a suitable electronic equivalent. New “T” 46CFR 184.420 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
Resolution: New charts were onboard
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 21 May 2025
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. The master’s MMC was deemed invalid due to expiration of their medical certificate 3 months prior. 46 CFR 15.401 (c)
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Mariner was replaced by qualified mariner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2024
Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw- down valve located on the forward side of collision bulkhead and operable from above from above the weather deck. A screw down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. The bilge line on the after side of the collision bulkhead was found to be inoperable. 46 CFR 182.25-5 (1)(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2024
Resolved 7 March 2024
Resolution: Installed a new bilge line on the after side of the collision bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall examine and test items to the extent necessary to determine that they are in proper operating condition and fit for the service in which they are intended. The installed bilge pump discharge flexible hoses are on a vital system that requires two hose clamps to be installed at both ends of the hose. 46 CFR 176.25-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 7 March 2024
Resolution: Installed two hose clamps on both ends of the hose for bilge pump discharge flexible hose.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2024
Resolved
Openings through which conductors enter shall be adequately closed. The engine room distribution panel is missing two circuit breaker blank spacers. 46 CFR 183.10-20(f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 7 March 2024
Resolution: Placed two circuit breakers in the blank spacers on the engine room distribution panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2024
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "Life Preservers" and with the number contained. Found the stowage locations not marked with the number contained. 46 CFR 185.30-10
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 March 2024
Resolved
Portable watertight containers for distress flares and smoke signals shall be of bright color, and containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: "DISTRESS SIGNALS". The vessel did not have there portable watertight containers for distress flares labeled correctly. 46 CFR 185.614
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2024
Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. The vessel had a battery in the engine room in a container that was not practicable for the size of battery. 46 CFR 183.05-20(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 7 March 2024
Resolution: Placed practicable for the size of battery in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2024
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. The water light 6 volt battery was expired in 2022. 46 CFR 185.726(d)
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2024
Resolved
Each water light must be of an approved automatic electric type constructed in accordance with 161. 010.Usage of a non recommended battery may cause the light to sink. Vessels 6 volt water light battery was missing the required manufacturers info; therefore, does not meet the approval requirement. 46 CFR 180.30(b)
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 March 2024
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting is on the ship and that each person handling garbage follows the plan. 46 CFR 184.702 and 33 CFR 151.57 (a)
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 6 March 2024
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The vessels port main propulsion engine was missing a guard on the front engine pulley. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 7 March 2024
Resolution: Placed a guard on the front engine pulley located on the port main propulsion engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2021
Resolved
BILGE PUMP AND SYSTEM - Vessel crew was unable to dewater forepeak using fixed bilge system. PRIOR TO CARRYING PASSENGERS, Vessel owner must successfully operate system through forepeak, accommodation area, and engine room bilge pickups in the presence of a Coast Guard Marine Inspector. 46 CFR "OLD T" 182.25-10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02AMR2021.Witnessed satisfactory operation of bilge suction from all compartments.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 February 2021
Resolved
ENGINEROOM HATCH - Each hatch exposed to the weather must be watertight. Engine Room hatches are missing bolts that make them watertight. Hatch gaskets need renewal. 46 CFR "OLD S" 171.124
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 26 October 2021
Resolution: Contacted owner. Inspectors visited boat during visit to marina. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 February 2021
Resolved
WIRE RUN FOR WINCH - Wire run for DC deck winch currently passes through a 1 1/2" hole in side of STBD Engine room vent. This hole must be made watertight.46 CFR "OLD S" 171.124
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02AMR2021.Witnessed satisfactory removal of wire and sealing of hole in stbd engine vent.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2021
Resolved
DEAD END WIRES - Wiring for deck winch currently ends on deck because the winch is removed from the vessel. Dead end wires must terminate in a junction box. On-deck junction boxes must be watertight. 46 CFR "OLD T" 183.10-20 (k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02AMR2021.Witnessed satisfactory removal of dead-ended wires for deck winch and installation of watertight closure for junction box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2021
Resolved
DECK WINCH INSTALLATION - No plan submittal or review has been found for the Deck Winch. Email the following to [email withheld]: A simple wiring diagram, wire specs (including type, length, gauge), winch specs (including weight, capacity, amperage), circuit breaker specs, and information on any other equipment on that circuit.46 CFR 177.202
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02AMR2021.Witnessed satisfactory removal of deck winch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2021
Resolved
OUTLET GROUNDS - Several outlets are showing "Bad Ground" on an outlet tester. Investigate and make satisfactory repairs. 46 CFR "OLD T" 183.10-20(o)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 26 October 2021
Resolution: Contacted Owner. Owner had electrician visit and inspect all outlets. Found no discrepancies with outlet grounds.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2021
Resolved
AC DISTRIBUTION PANEL - Circuit breakers on AC Panel in Engine room need to be labeled. CORRECTED ON THE SPOT. 46 CFR "OLD T" 183.01-10, 46 CFR "OLD J" 111.40-11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 24 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 February 2021
Resolved
LIFE FLOATS - Life Float paddles must be attached to the life float the belong. Life floats should not be used as storage space for other equipment. Life float water light batteries were expired but working. CORRECTED ON THE SPOT. 46 CFR 180.175 (a)&(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 February 2021
Resolved
DRILLS - The master shall conduct sufficient man overboard drills. No drills had been conducted or logged since USCG Annual Inspection in 2020. CORRECTED ON THE SPOT 46 CFR 185.520(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 March 2019
Resolved
Steering linkage for turn indicator was broken and held together with line.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 2 April 2019
Resolution: Owner replaced deteriorated line with new line.
Lifesaving › Lifefloat › Pendant
Issued 29 March 2018
Resolved
For both life floats, remove and replace dry-rotted pendants and grab lines.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Pendants and grab lines replaced
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 March 2018
Resolved
Life float missing floating waterlight. Provide waterlight attached around body of life float.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Waterlight added to lifefloat
Lifesaving › Lifefloat › Float Free
Issued 29 March 2018
Resolved
Current arrangement does not allow life floats to float free do to placement of mounting posts. Stow life floats in a float-free arrangement.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 4 April 2018
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 29 March 2018
Resolved
Vessel did not have any previous MIS reports on board. Provide proof that a MIS report was submitted for the previous year.
Action required: 705 - Other - as specified
Due 29 April 2018
Resolved 30 April 2018
Resolution: Received copy of MIS report submission for previous year.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 1 March 2016
Resolved
Fuel vent piping is missing the 30x30 mesh wire flame screen. 46CFR182.20-35(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 7 March 2016
Resolution: Verified flame screen in place.
Lifesaving › Lifefloat › Painter
Issued 1 March 2016
Resolved
Painter for life floats need repaired/replaced. 46CFR180.137
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 7 April 2016
Resolution: Verified new painter for life float