MAURY USCG vessel records Sign in
← All vessels

NORDIC APOLLO

NORDIC APOLLO is a 1980 tank ship. The Coast Guard has recorded 2 inspections since 1985, most recently in December 1986, along with 17 deficiencies.

Records from 1985 to 1986. Most recent: inspection, 30 December 1986.

Built
1980
Last inspected
30 December 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7390739 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-53836

Inspections, by type

…with no type recorded1
Years with a record 2 calendar years (1985–1986)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it76548 - Regulatory (Subpart C or D), Gross Ton
60334 - Regulatory (Subpart C or D), Net Ton
128785 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

30 December 1986 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1309415
20 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290332

Deficiency record · 17

Unknown
Issued 20 March 1985 Resolved
REPAIR REFRACTORY IN STBD BOILER: (A) MISSING FLOOR & OVHD REFRACTORY IN VESTIBULE BTWN SUPHTR & GEN. TUBES, (B) REPAIR FLOOR IN SUPERHEATER VESTI- BULE (C) OUTBOARD WALL & MISC. HOLES IN VESTIBULE OUTBOARD OF GEN. TUBES, (D) HOLE IN FWD WALL OUTBOARD CORNER OF FURNACE.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
FREE UP AND PROVE OPERATION OF FAINTAIL MUSHROOM VENTILATION CLOSURE PORT- SIDE.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
SUPERHEATER TUBE REPAIRS SUBMITTED PRIOR TO 25FEB85 TO [name withheld], HI MUST BE APPROVED OR THESE TUBES REPLACED. THIS ITEM WAS ORIGINALLY ISSUED BY [name withheld], HI ON 25FEB83 AT THE VESSELS PREVIOUS BIENNIAL INSPECTIONAND IS TO BE CLEARED OR RECINDED BY [name withheld], HI ONLY.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
CONDUCT NON-DISTRUCTIVE TESTING ON THREE NOTCHES IN SHEER STRAKE IN WAY OF PORT AND STBD LIFE BOATS WHICH ARE USED TO DRAIN STANDING DECK WATER. IF CRACK INDICATIONS ARE FOUND MAKE PERMANENT REPAIRS TO THE SATISFACTION OF THE ATTENDING INSPECTOR.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
INSTALL AN APPROVED STEAM DUMP SYSTEM FOR BOTH BOILERS. IF SAFETY VALVES LIFT IN COAL BURNING OPERATIONS THE MASTER OR CH. ENG. SHALL NOTIFY [name withheld] THIS ITEM WAS ISSUED BY [name withheld] OF 25FEB83 AND IS TO BE CLEARED OR RECINDED BY [name withheld] ADVISE OF STATUS.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
RENEW SOOT BLOWER IN STBD BOILER VESTIBULE BETWEEN THE GENERATING TUBES ANDTHE SUPER HEATER TUBES.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
CROP AND INSERT APPROX. 1 FT X 2 FT PORTION OF BUCKLED FRAME IN PORT PIPE TUNNEL FWD OF #3 WING TANK AT SHEER STRAKE. ALL WELDING TO BE IN ACCORDANCEWITH REQUIRED PROCEEDURES FOR HIGH TENSILE STRENGTH STEEL USED ON THE VESSELS SIDE SHELL.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
LIFT RELIEF VALVES AND OPEN D.C. HEATER AND CONTROL AIR RECEIVER FOR INSPECTION.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
MODIFY OR RENEW ESCAPE HATCH TO AFTER STEERING COMPARTMENT SO THAT IT CAN BE OPENED FROM THE INSIDE AND REMAIN WATERTIGHT WHEN CLOSED. IN THE INTERIM THIS HATCH IS TO BE SECURED FROM THE INSIDE ONLY.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
MAKE PERMANENT REPAIRS TO INBOARD SHIP SERVICE GENERATOR SALT WATER COOLINGVALVE.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
REPAIR AND SERVICE BURNER ROOM FIXED DRY CHEMICAL FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
REPAIR OR REPLACE PUMP ROOM FIXED CO2 SYSTEM ACTUATOR.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
REPAIR ELECTRICAL JUNCTION BOX CONNECTION IN WAY OF PORT ENTRANCE TO THE PUMP ROOM TO RESTORE ITS EXPLOSION PROOF DESIGN.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
PROVE OPERATION OF STEERING GEAR VENTILATION.
Condition: Unknown
Due 20 March 1985
Resolved 20 March 1985
Unknown
Issued 20 March 1985 Resolved
REPAIR STORM DAMAGE FORWARD INCLUDING: REPAIR TO STBD PIPE TUNNEL VENTI- LATOR, REPAIRS TO INDENTED ACCESS TO STBD PIPE TUNNEL AND SPRUNG CENTER RAILING FWD STBD SIDE.
Condition: Unknown
Due 31 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 March 1985 Resolved
REPAIR AND PROVE OPERATION OF PORT FIRE MAIN TRUNK ISOLATION VALVES.
Condition: Unknown
Due 21 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record