Records from 2016 to 2022. Most recent: inspection, 23 March 2022.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 March 2022
No resolution recorded
Inspect vessel hull in accordance with 46 CFR 176.610. Three holes were present in fwd stbd hull.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2022
No resolution recorded
Inspect fasteners in accordance with 46 CFR 176.610. Overall condition of visible fasteners are in unsatisfactory condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2022
No resolution recorded
Inspect interior components in accordance with 46 CFR 176.610. Port cutlass bearing interior outboard butt block was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2022
No resolution recorded
Inspect hull in accordance with 46 CFR 176.610. Keel fwd of the worm shoe was significantly deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021
Resolved
Replace the sea suction hose for the Marine Sanitation Device. Ensure the Marine sanitation device is installed IAW 33CFR part 159. Provide proof of replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2021
Resolution: Vessel owner provided proof of replaced sea suction hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2021
Resolved
Forward bilge pump is inoperable, needing replacement. Provide a bilge pump capable of pumping water from all watertight compartments as per 46CFR182.520(b)(1). Provide proof of repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2021
Resolution: Vessel owner demonstrated proper functionality of the forward bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021
Resolved
Remove assorted dead end wires from the vessel's Engine Room. All electrical equipment on a vessel must be maintained to provide services necessary for safety under normal and emergency conditions as per 46CFR183.200. Provide proof of repair prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspectors witnessed the removal of dead end wiring in the Engine Room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2021
Resolved
The inspected vessel is missing double hose clamps for all sea inlet valves. Double hose clamps are required to be placed on systems and applications are permitted to be clamped as per 46CFR182.410. Provide proof of double hose clamp installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector observed installed double hose clamps for all sea inlet valves.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2021
Resolved
Forward and Aft Bulkhead penetrations require foam to be inserted to ensure a proper seal. Provide proof of bulkhead correction.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed new foam sealent for forward and aft Engine Room Bulkhead.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 April 2021
Resolved
Replace dog in the stern hatch, replace in kind. Provide proof of replacement. All hatches and openings must be kept tightly closed except when being used.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed newly installed dog for stern hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2021
Resolved
The inspected vessel does not have labeled Escape Hatches throughout the vessel. All escape hatches and other emergency exits used as a means of escape must be marked on both sides with clearly legible letters at least 2 inches high as per 46CFR185.606.Provide proof of labeled Escape Hatches used as means of escape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed newlt labeled Escape Hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2021
Resolved
The inspected vessel's life-ring lifelights are inoperable with dead batteries. Life-rings with each floating waterlight must be operable as per 46CFR180.70(d)(1) and 46CFR161. Provide proof of operational lifelight on the life-rings throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed newly replaced life-ring lifelight. Equipment operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021
Resolved
The inspected vessel's switchboard in the storage closet currently maintains unlabeled breakers. The vessel is required to have all breakers labeled within the switchboard to ensure vessel safety. Provide proof of labeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: All breakers in the vessel's storage closet are properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2021
Resolved
The inspected vessel's life-ring is currently unlabeled. Life-saving equipment must be marked or painted in clearly legible letters and numbers as per 46CFR185.604. Provide proof of correction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed the properly labeled Life-Ring.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 8 April 2021
Resolved
The inspected vessel's fuel shut-off valve stations are unlegible. Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating the purpose of the valve. Provide correction of properly labeled stations that are unfaded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed properly labeled emergency fuel shut-off stations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 April 2021
Resolved
The inspected vessel's RPM gauges at the operating station are inoperable. Since the vessel contains an RPM gauge, it must follow the requirements of 46CFR182.410(b). Provide proof of repair.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed the proper operation and installation of Operating Station RPM Gauge.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2021
Resolved
The inspected vessel does not contain an anchor onboard. A vessel must be fitted with an anchor to complete safe operation as per 46CFR184.300. Provide proof of anchor replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed newly acquired anchor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021
Resolved
The inspected vessel is required to remove carpet to a sufficient capacity to access the Engine Room. Provide proof of sufficient ability to access the Engine Room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: CG Inspector witnessed newly cut-out carpet.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 April 2021
Resolved
The inspected vessel's Nautical publications are out of date. The vessel is required to maintain up-to-date charts and nautical publications as per 46CFR184.420. Provide proof of newly replaced documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: Vessel owner provided all newly updated Navigational Publications.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 April 2021
Resolved
The inspected vessel does not maintain a copy of the Coast Guard "Rules of the Road" publication. The operator of each self propelled vessel 12 meters or more in length shall carry onboard and maintain for ready reference a copy of the Inland Rules of the Road. Provide proof of newly acquired and updated publication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 6 May 2021
Resolution: Vessel owner provided an updated copy of Coast Guard Rules of the Road.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2020
Resolved
Provide proof of forward bilge pump high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 8 April 2021
Resolution: Vessel owner provided proof of Forward Bilge High Level Alarm.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2020
Resolved
Secure parlor deck flooring with securing brackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 8 April 2021
Resolution: Parlor deck flooring secured with brackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 August 2020
Resolved
Provide proof of Florida registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 8 April 2021
Resolution: Vessel owner provided proof of State Registration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020
Resolved
Renew port sea suction hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 8 April 2021
Resolution: Port Sea Suction valve replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 11 August 2020
Resolved
Stern hatch missing dog latch replace inkind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 6 May 2021
Resolution: Stern hatch dog latch replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2019
Resolved
Life float waterlight must be attached around body of lifefloat w/ 3/8" - 18ft line. Current line is only around 10ft.
46CFR180.175(f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 3 October 2019
Resolution: Replaced waterlight line.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2019
Resolved
The paddle for the lifefloat must be lashed to the lifefloat and properly marked.
46CFR180.175(f)(2)
46CFR185.604(g)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 3 October 2019
Resolution: Paddles were properly attached and marked as required.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 October 2019
Resolved
The ringbuoy must be stowed in a way that it can be rapidly cast loose and readily accessible. The ring buoy is mounted very losely to a ladder and hose hook up making it difficult to access.
46CFR180.70(b)(2)&(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 3 October 2019
Resolution: Ring buoy relocated and witnessed crew retrieve it quickly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
Emergency hatches must be marked with letters 1" high EMERGENCY EXIT - KEEP CLEAR. Hatch was not properly marked as required.
46CFR185.30-15
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 3 October 2019
Resolution: Emergency escape marked as required.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 October 2019
Resolved
The remote fuel shut off must be marked in letters 1" high indicating purpose and direction. Shut offs on vessel were not marked as required.
46CFR185.30-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 3 October 2019
Resolution: Fuel shut off marked as required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019
Resolved
Vsl is required to post emergency instructions. The vessel had none on board.
46CFR185.512
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 3 October 2019
Resolution: Emergency instructions were provided and posted in the lounge area.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 October 2019
Resolved
Flexible hose on engine must be protected from mechanical damage. Port & Stbd engine fuel lines are mounted in a way causing the hoses to be rubbed through.
46CFR182.720(e)(3)(ii)
Action required: 60 - Rectify deficiencies prior to movement
Due 2 October 2019
Resolved 3 October 2019
Resolution: Hoses were properly supported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Flexible or portable cords should not be used for permanently installed wiring. The vessel was found with multiple extension cords and power strips near TV and microwave installations.
46CFR183.10-20(a)(2)
Action required: 60 - Rectify deficiencies prior to movement
Due 2 October 2019
Resolved 3 October 2019
Resolution: all extension cords were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Wiring shere subject to mechanical damage shall be protected in accordance w/ NEC. Wiring throughout engine room was not properly supported, vsl was using zip ties.
46 CFR 183.05-50(a)(2)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 11 August 2020
Resolution: Engine room wiring was properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 October 2019
Resolved
Flexible non-metallic hoses must be in compliance w/ SAE J-1942 and fittings must comply with SAE J-1475. Port engine fuel supply and stbd engine fuel return are in unserviceable condition.
46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 11 August 2020
Resolution: Port and Stbd fuel supply return lines were replaced with acceptable hoses.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.802 for the vessel’s hull. The vessel’s Port and STBD chines contain areas of rotten wood. The vessel operator is required to replace the rotten areas of the Port and STBD chines to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: corrected; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.804 for the vessel’s machinery. The vessel’s STBD strut was loose. The vessel operator is required to repair the STBD strut to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: corrected; all SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.802 for the vessel’s hull. The vessel has two frames outboard of the port fuel tank that rotten. The vessel operator is required to replace the two rotten frames to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: Corrected; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.804 for the vessel’s machinery. Both the vessel’s cutlass bearings Port and STBD were severely worn. The vessel operator is required to replace both the Port and STBD cutlass bearings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: Corrected; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.804 for the vessel’s machinery. The vessel’s two fuel tanks (Port and STBD) show signs of severe wastage. The vessel operator is required to replace both of the vessel’s fuel tanks to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: Corrected; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2017
Resolved
The vessel shall meet the material standards of 46 CFR 176.806 for the vessel’s electrical systems. The breakers on vessel’s generator do not meet the manufacturer’s standards. The vessel operator is required to restore the breakers on the vessel’s generator back to manufacturer’s standards (2x 35AMP Breakers).
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: Corrected; all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 November 2017
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel is undergoing extensive wood repairs and replacement. The vessel operator is required to conduct underway sea trials with the attending CG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 29 March 2018
Resolution: Corrected; all SAT.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 31 January 2017
Resolved
Lazarette steering both port and stbd shaft packing renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Construction/Loadline › Hull › Side Shell
Issued 31 January 2017
Resolved
ID all leaks from frames in the Engine room lazarette, and FWD compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 January 2017
Resolved
Lazarette high water alarm visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2017
Resolved
Loose wires in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2017
Resolved
Hard wire the consta volt charger in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 31 January 2017
Resolved
Exhuast leaks on Port and STBD engine exhuast piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 31 January 2017
Resolved
Vibration STBD shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 January 2017
Resolved
Lable alarms, Pumps, and Panelboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2017
Resolved
Bow hand rail is loose, renew and repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Engineering › Steering Gear System › Rudder Bearing
Issued 15 December 2016
Resolved
Lazaret steering both Port and STBD Shaft Packing renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Construction/Loadline › Hull › Side Shell
Issued 15 December 2016
Resolved
Identify leaking frames on vessels wooden hull. Eng room and Steering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Engineering › Bilge Water Management System › Not Operational
Issued 15 December 2016
Resolved
Indicating Light for the High water monitoring system repair for the Lazaret.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 December 2016
Resolved
Loose wiring throughout Eng Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 December 2016
Resolved
Port and STBD Eng exhaust leaks repair/renw piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Electrical › Electric Supply System (service) › Battery Charger
Issued 15 December 2016
Resolved
Hard wire Consta volt charger in eng space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Engineering › Shafting/Propeller Arrangements › Strut
Issued 15 December 2016
Resolved
Vibration on STBD Shaft, investigate issue.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 December 2016
Resolved
Bow Hand rail/Deck Rail is loose renew or repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 15 December 2016
Resolved
Pumps and Alarms lable in ENG space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Documentation › Certificates/Documents › FCC SSL
Issued 1 December 2016
Resolved
Provide FCC Station Lic. for vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 December 2016
Resolved
Provide Life float light and line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Navigation › Piloting/Steering › Marine Charts
Issued 1 December 2016
Resolved
Provide Charts and Publications.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 December 2016
Resolved
Provide Emergency Checklist.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 December 2016
Resolved
Provide Sevcing report for Fixed system.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Communications › Radio Communications › EPIRB
Issued 1 December 2016
Resolved
EPIRB testing log book.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2016
Resolved
Provide First Aid kit.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Communications › Audible Communications › Horn/Whistle
Issued 1 December 2016
Resolved
Provide vessel horn/bell.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Fire Fighting › Fire Bucket › Availability
Issued 1 December 2016
Resolved
Provide 3 Fire Buckets for vessel.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 December 2016
Resolved
Provide Served FFE as stated on COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 December 2016
Resolved
Fuel shut off valves are more than 12 inches, provide a means to make close to the deck opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 December 2016
Resolved
Hard wire E-Light into Breaker box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2016
Resolved
Provide Engine, Generator, and Steering Lazaret for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Had vessel underway for inspection of spaces.