MAURY USCG vessel records Sign in
← All vessels

REEL FUN

REEL FUN is a 1973 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1985, most recently in January 2026, along with 148 deficiencies — 1 with no resolution recorded —, 1 operational control and 4 casualty investigations between 2010 and 2013.

Records from 1985 to 2026. Most recent: inspection, 27 January 2026.

Built
1973
Last inspected
27 January 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3220
Flag
UNITED STATES
368043080
Maury page id
psix-53850

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1985–2026)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.6 ft × 18.5 ft × 6.2 ft
Registered tonnagegross 57 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHIDALGO CEDAR CORP · MIAMI, FL, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOCEAN CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3220MMSI 368043080 · active · compulsorily equipped · granted 6 June 2018, expires 6 June 2028
WDE4396MMSI 367352560 · expired · compulsorily equipped · granted 29 April 2008, cancelled 30 June 2018
WCX4624MMSI 367169920 · expired · compulsorily equipped · granted 1 March 2007, cancelled 8 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 85

27 January 2026 Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8299426
15 January 2026 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8296730
9 April 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8108081
11 October 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8017722
11 March 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7877391
22 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7852608
10 January 2024 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7847810
16 August 2023 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769636
27 April 2023 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7677376
7 April 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7668512
24 May 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7458333
1 March 2022 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7403448
21 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7363089
18 December 2020 Special Consideration
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7113832
7 December 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7108103
4 February 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6901885
10 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6870215
3 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6802811
16 January 2019 DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6605234
14 November 2018 In-Service Inspection · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6580888
23 October 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6573525
23 April 2018 Administrative Inspection · Plan Review "T" Boat · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402619
13 June 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5906840
16 October 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5006030
8 October 2014 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5045407
15 August 2014 Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4958358
7 June 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4335622
30 January 2012 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4234627
18 January 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4226981
9 February 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3677576
29 April 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3194784
21 March 2008 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3168722
2 May 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2919602
19 April 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2627999
17 March 2006 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2604271
2 May 2005 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2347330
10 May 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2228414
6 April 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2044566
13 May 2003 Periodic Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1787872
3 May 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1612465
17 April 2001 Annual Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059807
14 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1060670
8 June 2000 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 819142
21 March 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816543
3 February 2000 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 814640
20 April 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126586
26 March 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1118127
27 March 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 792235
18 January 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 16336
1 April 1997 COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108571
16 July 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1090222
26 March 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1078362
28 March 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1179238
16 March 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177617
7 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 837011
31 January 1995 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 829687
22 July 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1171101
10 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1331377
7 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 861119
31 March 1994 Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858909
25 February 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 837895
28 January 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 831226
18 June 1992 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1261745
29 January 1992 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1254993
20 June 1991 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208188
7 June 1991 Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 933628
28 March 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219589
19 March 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 928022
1 May 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215354
21 March 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1212123
17 May 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343409
20 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1203023
30 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888174
28 April 1988 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343978
13 April 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036373
8 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1308161
4 November 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1021406
2 May 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023299
8 April 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023296
22 May 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1304787
29 April 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998759
7 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306507
5 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296282
8 May 1985 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983665
16 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981277

Deficiency record · 148

03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 April 2026 No resolution recorded
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. 03 fwd bridge windows found to have cracks. o/o shall provide repair proposal to replace windows to the satisfaction of MI no later than September 30th 2026. For vessel to continue operation, Owner must restrict passengers from being around bridge windows. Prior to September 30, 2026 46CFR 177.1010
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 January 2026 Resolved
Where the amount of carbon dioxide...such an extinguisher may be used...Vessel was unable to test heat detection in E/R as required by special consideration. MI must witness heat detection test. 46 181.400 CFR (b)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 30 January 2026
Resolution: Verified during attendance.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 January 2026 Resolved
Except when in the judgment of the cognizant OCMI...The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel’s emergency instructions do not include how and when to use the extinguishing system IAW the vessel’s special consideration. Update emergency instructions and post at the operating station. 46 CFR 185.510 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 30 January 2026
Resolution: Verified during attendance.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 January 2026 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this Chapter. Open penetrations on the port and stbd side wire runs on aft bulkhead . Seal penetrations to comply with stability letter to the satisfaction of attending MI. 46 CFR 177.13-1 Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 9 February 2026
Resolution: Verified in person
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 January 2026 Resolved
Except as otherwise provided in this section... Overhead on stbd side of generator space has open access to inside the stbd forward bench in accommodation. Seal opening to the satisfaction of attending MI. 46 CFR 182.35-1 Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 9 February 2026
Resolution: Owner completed to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2026 Resolved
All electrical installations shall be to the satisfaction of the attending Marine Inspector. Multiple dead end wires were found inside battery charger on aft wall of generator room. Remove or terminate wires to the satisfaction of attending MI. 46 CFR 183.01-15 Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 9 March 2026
Resolution: battery charger was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2026 Resolved
All electrical installations shall be to the satisfaction of the attending Marine Inspector. Wiring boxes for the port and starboard keel cooler expansion tank gauges had loose wires. Provide appropriate clamps for boxes to ensure wiring cannot be disconnected to the satisfaction of attending MI. 46 CFR 183.01-15 Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 30 January 2026
Resolution: Verified during attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 January 2026 Resolved
Water for cooling the exhaust pipe …. The water must pass through the entire length of the exhaust pipe. Port and starboard flexible hoses attached to both sides of muffler in lazzarette had small leaks. Determine and secure source of leaks to the satisfaction of attending MI. 46 CFR 182.15-15(b)(2) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 2 June 2026
Resolution: Inspected the vessel in the water and found no leaks
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 January 2026 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter.... Port rudder has a small leak. Determine cause and repair prior to dry dock credit. 46 CFR 176.25-1(a) Old T
Action required: 705 - Other - as specified
Resolved 28 April 2026
Resolution: Witnessed operation of rudder with no weaping. Bolts found loose and replaced by O/O
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2025 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel did not have COI posted in a conspicuous area. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 23 April 2025
Resolution: Posted COI to satisfaction of MI.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 9 April 2025 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessels max allowable passengers on upper deck was painted over and not visible. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 23 April 2025
Resolution: O/O marked clearly pax count for upper deck to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 11 March 2024 Resolved
The construction, arrangement and equipment of all vessels shall be acceptable to the cognizant officer in charge, marine inspector. The previously identified crack in the support beam located in the #2 (forward storage) compartment has been satisfactory temporarly repaird. Permanent repairs to the satisfaction of the attending marine inspector must be made prior to next credit dry dock.
Action required: 705 - Other - as specified
Resolved 29 April 2026
Resolution: Completed to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 January 2024 Resolved
THE CONSTRUCTION, ARRANGEMENT AND EQUIPMENT OF ALL VESSELS SHALL BE ACCEPTABLE TO THE COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION. MARINE INSPECTOR IDENTIFIED CRACK IN SUPPORT BEAM LOCATED IN THE #2 (FORWARD STORAGE) COMPARTMENT ON THE STARBOARD AFT OVERHEAD. VESSEL IS REQUIRED TO SUBMIT REPAIR PLAN PROPOSAL IAW NVIC 07-95 FOR APPROVAL. WORK CANNOT START UNTIL REPAIR PLAN IS APPROVED. 46 CFR OLD "T" 176.01-10(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2024
Resolution: Temporary repairs have been made to the crack in the support beam to the satisfaction of the attending marine inspector. Photos to the repiar uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 January 2024 Resolved
Vessel's owner did not have servicing records on board for fire equipment. Vessel must provide satisfactory evidence of required servicing to marine inspector for rectification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2024
Resolved 24 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 January 2024 Resolved
Vessel's owner could not provide monthly EPIRB test logs. Vessel must provide documentation to marine inspector for rectification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2024
Resolved 24 January 2024
Resolution: Owner showed monthly EPIRB test records.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 January 2022 Resolved
Medical Certificates issued to all other mariners will be issued for a maximum period of 5 years. O/O medical certificate expired in 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 11 March 2022
Resolution: Owner provided medical certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2022 Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Life floats can be substituted for IBA's. Vessel was having 01 lifefloat serviced and therefore missing. Reducing total persons allowed onboard to 40, due to the lifefloats on board on cold water operations being 100%.
Action required: 705 - Other - as specified
Resolved 11 March 2022
Resolution: Removed damaged life float from COI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 January 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections sections of the International and Inland Navigation Rules. Vessel has an uninstalled anchor light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 1 March 2022
Resolution: USCG satisfied with installation of anchor light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 January 2022 Resolved
The operator of each self-propelled vessel 12 meters or more shall carry on board and maintain for ready ref. a copy of the Inland Rules. Vessel was missing Inland Navigation Rules
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 1 March 2022
Resolution: USCG saw vsl's Inland Navigation Rules.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 January 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. Vessel was missing U.S. Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 1 March 2022
Resolution: USCG saw vsl's U.S. Coast Pilot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2022 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with 161.012 in subchapter Q. Vessel was missing lights on 43 lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 26 May 2022
Resolution: Confirmed presence of 103 life jacket with lights during follow up inspection on 5/26/22.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2022 Resolved
USCG was not notified regarding rectification of 05 deficiencies that were issued on 21JAN2022, which were due on Sunday, 20FEB2022. Owner/operator did not asked for an extension. Contact USCG Sector Delaware Bay when the rectification of the deficiencies can be reviewed by a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2022
Resolution: Unresolved defs were addressed during drydock inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2020 Resolved
38 of 108 PFDs were found without lights. All PFDs on vessels with an oceans route need to be provided with appropriate lights. PFDs without lights shall be stowed on upper deck and remain inaccessible to passengers and ensure 56 PFDs with lights are accessible to passengers while operating on an Oceans Route.. 46 CFR 180.75
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 21 January 2022
Resolution: Cleared deficiency and issued an updated deficiency (changed verbiage so that all life jackets have lights since the vsl is authorized to operate on an oceans route).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2020 Resolved
Port and starboard rudder post were observed leaking consistently while underway. Tighten or replace packing as needed. 46 CFR 176.814.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 21 January 2022
Resolution: Port and starboard rudder post were not leaking when steering was tested at the pier. USCG satisfied to rectify deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2020 Resolved
Vessel is not equipped with a warning device to indicate failure of water flow to the exhaust cooling system. Install a warning device with an audio and visual alarm at the operating station. 46 CFR 182.15-15(b)(5) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 January 2022
Resolution: USCG satisfied with warning device on exhaust cooling system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 December 2020 Resolved
4/0 AWG wire in port battery bank in generator room is installed with a fitting designed for a smaller wire gauge. Replace with a fitting designed for 4/0 AWG. 46 CFR 183.05-50 (OLD T)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 21 January 2022
Resolution: USCG satisfied with wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2020 Resolved
Starboard emergency fuel shut off valve was weeping fuel. Repair /replace valve. 46 CFR 182.15-40(b)(3)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 21 January 2022
Resolution: Starboard emergency fuel shut off valve was not weeping fuel during 3rd annual inspection on 21JAN2022. USCG satisfied to clear deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 February 2020 Resolved
Seal cable penetrations between laz and engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: Cable penetrations sealed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 February 2020 Resolved
Replace broken hatch cover for forepeak. Hatch is allowing water ingress.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: Owner rebuilt hatch. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 February 2020 Resolved
Replace CO2 system following servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: CO2 system reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2019 Resolved
repair and make functional forepeak bilge piping arrangement. Unable to pump out space. 46 CFR 182.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Repairs made and witnessed pump out of most fwd space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2019 Resolved
Repair leaking coolant head tank in space fwd of accommodation space. 46 CFR 182.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 July 2020
Resolution: Coolant leak has been repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019 Resolved
Remove extension cords and provide plans for permanent wiring, if desired. 46 CFR 183.10-20(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 July 2020
Resolution: Extention cords have been removed for temp fans that were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019 Resolved
Repair open ground in electrical outlet circuit for aft port side of accommodation space. 46 CFR 183.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 18 March 2020
Resolution: Outlet repaired. Tested circuit and found satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 10 December 2019 Resolved
Repair outside overhead light, port side, fwd, outside of accommodation space 46 CFR 183.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 July 2020
Resolution: Overhead light has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2019 Resolved
removed 01 life jacket from service, vessel has sufficient quantity to comply with COI. Lifejacket had tear around neck hole. 46 CFR 180.71
Action required: 10 - Deficiency Rectified
Due 10 December 2019
Resolved 10 December 2019
Resolution: removed life jacket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2019 Resolved
Repair or replace leaking valve on generator cooling line at "T" elbow in #3 space. prior to completed dry dock 46 CFR 182.01-5
Action required: 705 - Other - as specified
Resolved 13 July 2020
Resolution: Leaking coolant line has been replaced with new T.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 December 2019 Resolved
Replace or remove for inspection the port fuel tank fill hose flexible connection. The hose appears to be collapsed or creased from external inspection. Prior to completed dry dock. 46 CFR 182.20-30(d)
Action required: 705 - Other - as specified
Resolved 13 July 2020
Resolution: Owner replaced fill line for port diesel tank.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 January 2019 Resolved
Replace anchor light. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 9 July 2019
Resolution: Owner sent picture showing operational anchor light.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 June 2018 Resolved
07113 Install hydrants for fire pump so that a 50' hose can reach every point on the boat. Vessel is limited to 49 passengers until installed. 46 CFR "Old T" 181.10-1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 14 June 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2016 Resolved
JD02: Vessel must prove VHF radio DSC capable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 20 September 2019
Resolution: Cleared due to extended period open. Believed to be corrected at last 3 annual inspections
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 June 2016 Resolved
Vessel must replace retro tape on 05 adult lifejackets. Passenger count is reduced to 102.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 1 July 2016
Resolution: Owner replaced retro tapa on lifejackets
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 June 2016 Resolved
Vessel must replace grab line on life ring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 1 July 2016
Resolution: Vessel replaced line on ring life buoy.
Construction/Loadline › Hull › Weld
Issued 8 October 2014 Resolved
Work list item JE05. Repair ladder railing forward of the pilot house and crack in rub rail approximately 30ft forward of transom on portside.
Action required: 705 - Other - as specified
Resolved 18 May 2015
Resolution: Vessel made proper repairs.
Stability › Weathertight Integrity › General
Issued 8 October 2014 Resolved
Work List item JE01. Replace through hull valve on saltwater wash down line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2015
Resolution: Vessel replaced valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 August 2014 Resolved
During Operation Boomerang, vessel was found to have a broken "all around" light post. Vessel made temporary repairs, but must make permanent repairs.
Action required: 705 - Other - as specified
Due 25 August 2014
Resolved 25 August 2014
Resolution: Vessel made permanent repairs to it all around light and verified proper operation.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 June 2012 Resolved
Single Side Band Radio microphone cord broken off at connection point. Radio inoperable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 June 2012
Resolution: Recieved visual confirmation that the Single Side Band microphone cord has been replaced in kind as well as new Radio Isntallation Safety Certificate.
Construction/Loadline › Structures › Superstructure
Issued 29 March 2012 Resolved
Ladder and associated hardwear not properly attached in regards to forward ladder to upper deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2013
Resolution: Ladder and associated hardwear is properly attached as inspected during 18 June 2013.
Engineering › Bilge Water Management System › Pump
Issued 29 April 2008 Resolved
Prove proper operation of Bilge Pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2008
Resolved 22 May 2008
Resolution: Engine room bilge compartment dewatered, bilge pump working properly, all SAT
Communications › Radio Communications › EPIRB
Issued 2 May 2007 Resolved
Provide current hydrostatic release for EPIRB.
Due 16 May 2007
Resolved 16 May 2007
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2007 Resolved
Provide current FCC safety certificate.
Due 16 May 2007
Resolved 16 May 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2007 Resolved
Provide current Radio Station lisence.
Due 16 May 2007
Resolved 16 May 2007
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 2 May 2007 Resolved
Vessel required to make supervised circuit on the fire detection system operable.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 29 April 2008
Resolution: Fixed fire detection system is working properly.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 April 2006 Resolved
PROVIDE OPERATIONAL WATER LIGHT.
Action required: 705 - Other - as specified
Resolved 21 April 2006
Resolution: OWNER INSTALLED NEW WATER LIGHT ON LIFEFLOAT.
Engineering › Bilge Water Management System › Pump
Issued 18 April 2006 Resolved
PROVIDE PORTABLE HAND BILGE PUMP.
Due 2 May 2006
Resolved 21 April 2006
Resolution: WITNESSED HAND PORTABLE BILGE PUMP ONBOARD.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 March 2006 Resolved
NETTING ON UPPER DECK WASTED NEEDS TO BE REPLACED/REPAIRED.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Resolution: Netting on upper deck replaced with new netting. Installation SAT.
Lifesaving › Lifefloat › Netting
Issued 2 May 2005 Resolved
NETTING WASTED, REQUIRED TO BE REPLACED.
Action required: 705 - Other - as specified
Resolved 23 May 2005
Resolution: WITNESSED NEW NETTING INSTALLED.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 2 May 2005 Resolved
PROVE PROPER OPERATION OF SSB RADIO.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Resolution: RECIEVED TECH REPORT PROVING PROPER OPERATION.
Communications › Radio Communications
Issued 13 May 2003 Resolved
PROVIDE HYDROSTATIC RELEASE FOR EPIRB PRIOR TO JUNE 2003. LEGACY COMPONENT DESC: EPIRB
Due 31 May 2003
Resolved 16 July 2003
Resolution: NEW HYDROSTATIC RELEASE INSTALLED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2003 Resolved
PROVIDE EYEWASH & ASPIRIN FOR FIRST AID KIT.
Due 20 May 2003
Resolved 16 July 2003
Resolution: EYEWASH & ASPIRIN PROVIDED FOR FIRST AID KIT.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 May 2003 Resolved
PROVIDE CURRENT LIGHT LIST.
Due 20 May 2003
Resolved 16 July 2003
Resolution: NEW LIGHT LIST PROVIDED.
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 May 2003 Resolved
PROVIDE CURRENT COAST PILOT.
Due 20 May 2003
Resolved 16 July 2003
Resolution: CURRENT COAST PILOT PROVIDED.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 May 2003 Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES.
Due 20 May 2003
Resolved 16 July 2003
Resolution: UP TO DATE TIDAL CURRENT TABLE PROVIDED.
Navigation › Piloting/Steering › Marine Charts
Issued 13 May 2003 Resolved
PROVIDE UP TO DATE NAV CHART # (12326).
Due 20 May 2003
Resolved 16 July 2003
Resolution: UP TO DATE NAV CHART PROVIDED.
Lifesaving › Buoyant Apparatus
Issued 13 May 2003 Resolved
PROVIDE PASSENGER CAPACITY COUNT ON ALL LIFE FLOATS.
Due 20 May 2003
Resolved 16 July 2003
Resolution: PASSENGER CAPACITY COUNT MARKED ON ALL LIFE FLOATS.
Lifesaving › Buoyant Apparatus
Issued 13 May 2003 Resolved
PROVIDE SPACERS BETWEEN ALL LIFE FLOATS. LEGACY COMPONENT DESC: Spacers
Due 20 May 2003
Resolved 16 July 2003
Resolution: SPACERS PROVIDED BETWEEN ALL LIFE FLOATS.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 May 2003 Resolved
MAKE NON OPERATING SEARCH LIGHTS OPERATIONAL & INSTALL LENSES WHERE NEEDED.
Due 20 May 2003
Resolved 16 July 2003
Resolution: ALL NEEDED REPAIRS MADE TO SEARCH LIGHTS.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 April 2003 Resolved
REPLACE/RECONDITION PORT AND STBD PROPS. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Improper/Lack of Maintenance
Due 16 April 2003
Resolved 6 April 2004
Resolution: New port and stbd props replaced with new.
Lifesaving › Buoyant Apparatus
Issued 3 May 2002 Resolved
RENEW ALL POLYPROPYLENE LINE ON LIFEFLOATS
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 May 2002 Resolved
REPLACE 60FT HEAVING LINE AND RING BUOY LINE
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Stability › Structures
Issued 3 May 2002 Resolved
RELABLE UPPER DECK WITH PASSENGER CAPACITY
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 May 2002 Resolved
LINE OUT OLD VESSEL NAME ON LIFE JACKETS
Due 3 May 2002
Resolved 3 May 2002
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 3 May 2002 Resolved
REPLACE RETRO TAPE ON LIFE JACKETS
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 3 May 2002 Resolved
REOMOVE EXTENSION CORD FROM LOCKER
Due 3 May 2002
Resolved 3 May 2002
Engineering › Bilge Water Management System › Valve
Issued 3 May 2002 Resolved
INSTALL POSITIVE SHUT-OFF VALVES IN RULE PUMP DISCHARGE HOSES BEFORE PENETRATING HULL
Condition: Improper Installation
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline › Structures › Door
Issued 3 May 2002 Resolved
LABEL AFT ACCOMODATION SPACE DOOR WITH "EXIT"
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 May 2002 Resolved
TIGHTEN BOTH SHAFT PACKING GLANDS
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Engineering › Steering Gear System › Rudder Stock
Issued 3 May 2002 Resolved
TIGHTEN BOTH RUDDER PACKING GLANDS
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline › Hull › Bracket
Issued 3 May 2002 Resolved
REPLACE BROKEN PORT RUDDER SUPPORT BEAM - RENEW IN KIND
Condition: Damaged By Earlier Event
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline
Issued 17 April 2001 Resolved
PROCURE AND RE-INSTALL BILGE STRAINERS IN FORWARD AND AFT COMPARTMENTS.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Construction/Loadline
Issued 17 April 2001 Resolved
RE-INSTALL AFT KEEL COOLER PROTECTION WEDGES ON BOTH PORT AND STBD SIDE HULL.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Construction/Loadline
Issued 17 April 2001 Resolved
PROPERLY PLUG OFF OLD TOILET THRU-HULL SUCTIONS PORT AND STBD SIDE OF #2 COMPARTMENT.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 14 March 2001 Resolved
VESSEL IS LIMITED TO 121 PASSENGERS WHEN OPERATING W/I 3 MILES ON LIMITED COASTWISE ROUTE DURING COLD WATER MONTHS AND 121 PASSENGERS ON LIMITED COASTWISE ROUTE DURING WARM WATER MONTHS. LIFE RINGS NO LONGER ACCEPTED ASPRIMARY LIFE SAVING.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Lifesaving
Issued 14 March 2001 Resolved
VESSEL IS LIMITED TO 60 PASSENGERS WHEN OPERATING BEYOND 3 MILES ON LIMITEDCOASTWISE ROUTE DURING COLD WATER MONTHS, IN ADDITION TO ANY OTHER LIMITATIONS ON VESSEL'S COI.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Engineering
Issued 21 March 2000 Resolved
REPAIR FUEL OIL LEAKS ON BOTH PORT AND STARBOARD FUEL OIL SUCTION LINES ANDREMOVE FUEL OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 21 March 2000 Resolved
PROVIDE PROVIDE PROOF OF PURCHACE AND INSTALL 20 NEW LIFEJACKET WATER LIGHTS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 21 March 2000 Resolved
PROVIDE PROOF OF SERVICING TO FIXED CO2 SYSTEM, INSTALL SAFETY PIN ON DISCHARGE HANDLE AND POST OPERATING INSTRUCTIONS AT SYSTEM.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Navigation
Issued 21 March 2000 Resolved
PROVIDE UP TO DATE CHARTS FOR VESSELS OPERATING AREA.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 21 March 2000 Resolved
INSTALL MAXIMUM PASSENGER CAPACITY SIGN ON UPPER DECK.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 21 March 2000 Resolved
PROVIDE LIFE JACKET DONNING PLACARD IN PASSENGER SPACE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 21 March 2000 Resolved
PROVIDE BONDING STRAPS FOR BOTH PORT AND STARBOARD FUEL OIL FILL CONNECTIONS.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 20 April 1999 Resolved
PROVIDE FIXED FIRE-EXTINGUISHING/FIRE DETECTION SYSTEM FOR INSPECTION AND TESTING.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Unknown
Issued 27 March 1998 Resolved
COMPLETE ITEMS 1,2,3 & 7 ON MSO PHILADELPHIA WORKLIST FOR THIS VESSEL DATED26MAR98, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 30 April 1998
Resolved 27 April 1998
Lifesaving
Issued 1 April 1997 Resolved
MAJORITY OF PERSONNEL MARKER LIGHTS FOR PFD'S EXPIRE 30APR97. AFTER 30APR97VSL LIMITED TO 19 PASSENGERS AND 02 CRRRRREW ON AN OCEANS ROUTE DUE TO EXPIRATION OF CHEMICAL LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 17 July 1997
Resolved 9 October 1997
Engineering
Issued 26 March 1996 Resolved
PROPERLY SECURE RACOR FUEL FILTER FOR SSG.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Electrical
Issued 26 March 1996 Resolved
PROPERLY CLEAN ALL BATTERY TERMINALS
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Electrical
Issued 26 March 1996 Resolved
COMPLETE WIRING OF NEW BILGE PUMPS AND ASSOCIATED LEVEL ALARMS.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Lifesaving
Issued 28 March 1995 Resolved
PRIOR TO CARRYING MORE THAN 37 PERSONS ON AN OCEANS ROUTE OR MORE THAN 74 PEOPLE ON A COASTWISE ROUTE, REPLACE THE WEAK LINK ON THE 25 PERSON LIFEFLOAT (OR PROVIDE THE MISSING CERTIFICATION TAG).
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 28 March 1995 Resolved
WATERLIGHT FOR LIFEFLOAT INOP
Condition: Unknown
Due 17 April 1995
Resolved 11 April 1995
Fire Fighting
Issued 28 March 1995 Resolved
PORTABLE FIRE EXTINGUISHERS REQUIRE ANNUAL SERVICING
Condition: Unknown
Due 17 April 1995
Resolved 11 April 1995
Construction/Loadline
Issued 16 March 1995 Resolved
PROVIDE COPY OF SPECIFICATIONS FOR MATERIALS USED AND LAB TEST RESULTS FOR AS-BUILT FIBERGLASS STRENGTH, RELATED TO REPAIRS TO DELAMINATION AND WATER SOAKED BALSA CORE IN THE STARBOARD SIDE SHELL AT THE ENGINEROOM. (ABOUT 10 SQUARE FEET OF (FOAM) CORE RENEWAL AND NEW INNER FIBERGLASS LAMINATE)
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Engineering
Issued 16 March 1995 Resolved
REPLACE FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Construction/Loadline
Issued 16 March 1995 Resolved
REPAIR FRP SIDE HULL INTERIOR, STARBOARD SIDE, IN AREA OF FUEL TANKS, TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Construction/Loadline
Issued 31 January 1995 Resolved
PRIOR TO CARRYING PASSENGERS, COMPLETE A DRYDOCK EXAMINATION TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 10 June 1994 Resolved
PROVIDE PROPER MARKINGS FOR THE LIFEJACKET BOXES IN THE MAIN CABIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1994
Resolved 10 June 1994
Lifesaving
Issued 10 June 1994 Resolved
PRIOR TO CARRYING MORE THAN 104 PASSENGERS (ON A COASTWISE ROUTE), PROVIDE 24 ADDITIONAL USCG APPROVED ADULT-SIZE TYPE I LIFE PRESERVERS.
Condition: Unknown
Due 10 June 1994
Resolved 10 June 1994
Engineering
Issued 31 March 1994 Resolved
TIGHTEN THE PACKING ON THE STARBOARD SHAFT TO REDUCE WATER FLOW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Lifesaving
Issued 31 March 1994 Resolved
PROVIDE WATERLIGHTS ON ALL PFD'S. THE ROUTE IS REDUCED TO COASTWISE ONLY UNTIL THIS ITEM IS CORRECTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Navigation
Issued 31 March 1994 Resolved
PROVIDE A MAGNETIC COMPASS DEVIATION CARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Navigation
Issued 31 March 1994 Resolved
PROVIDE CURRENT NAUTICAL CHARTS FOR THE VESSELS ROUTE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Navigation
Issued 25 February 1993 Resolved
PROVIDE AN UPDATED COPY OR AN APPLICABLE EXTRACT FROM THE US COAST PILOT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 25 February 1993 Resolved
PROVIDE AN UPDATED COPY OF THE RULES OF THE ROAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Construction/Loadline
Issued 25 February 1993 Resolved
REMOVE EXCESS OIL FROM THE ENGINEROOM BILGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Lifesaving
Issued 25 February 1993 Resolved
RESTENCIL THE VESSEL NAME ON ALL LIFEFLOAT PADDLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Lifesaving
Issued 25 February 1993 Resolved
REPLACE THE BROKEN LIFEFLOAT WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Lifesaving
Issued 25 February 1993 Resolved
REPLACE THE OUTDATED EPIRB WITH ONE MANUFACTURED AFTER 01OCT88._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Documentation
Issued 25 February 1993 Resolved
RENEW FCC OPERATORS PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Fire Fighting
Issued 25 February 1993 Resolved
PROVIDE TEST OF THE FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 25 February 1993 Resolved
REPAIR THE WATER LEAK ON THE PORT EXHAUST MUFFLER IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Electrical
Issued 25 February 1993 Resolved
REPAIR THE BROKEN GROUNDING WIRE IN THE STEERING COMPARTMENT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Accommodation/Occupational Safety
Issued 25 February 1993 Resolved
PROVIDE TEST OF TOILET PUMPS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 25 February 1993 Resolved
DEMONSTRATE OPERATION OF THE SHIP'S HORN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Electrical
Issued 28 January 1993 Resolved
REMOVE WIRE NUTS FROM TOILET MOTOR AND LIGHT IN E/R AND REWIRE USING APPROVED WIRE CONNECTIONS.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Lifesaving
Issued 28 January 1993 Resolved
RENEW BOARD PLATFORM IN 15MAN LIFEFLOAT.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Construction/Loadline
Issued 28 January 1993 Resolved
RENEW NIPPLE FOR BOW COMPARTMENT FIXED BILGE PIPING SYSTEM.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Construction/Loadline
Issued 28 January 1993 Resolved
REPAIR/RENEW MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Engineering
Issued 28 January 1993 Resolved
RENEW BOTH MAIN ENGINE STERN EXHAUST PIPE PENETRATION RETAINER RINGS.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Construction/Loadline
Issued 28 January 1993 Resolved
RENEW GASKET TO SCUTTLE TO AFTER STEERING.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Electrical
Issued 7 June 1991 Resolved
Resubmit eleectircal dwgs of generator installation showing: (a) full gen. nameplate data; (b) circuit bkr specs.; (c) xfer sw. specs.; (d) all meters; (e) bonding gnd. sys; (f) 12 VDC starting and charging system.
Condition: Unknown
Due 17 June 1991
Resolved 10 March 1992
Electrical
Issued 7 June 1991 Resolved
Replace generator 60amp CB panel with one of the correct size.
Condition: Unknown
Due 1 July 1991
Resolved 10 March 1992
Electrical
Issued 7 June 1991 Resolved
Provide condensate drain holes in generator junction box.
Condition: Unknown
Due 1 July 1991
Resolved 10 March 1992
Electrical
Issued 7 June 1991 Resolved
Install a 2nd AC ammeter.
Condition: Unknown
Due 1 July 1991
Resolved 10 March 1992
Electrical
Issued 7 June 1991 Resolved
Prove proper operation of voltage regulator in generator battery charging system.
Condition: Unknown
Due 1 July 1991
Resolved 10 March 1992
Electrical
Issued 7 June 1991 Resolved
Install dripproof covers on generator CB panel, the xfer switch and the main distribution panel.
Condition: Unknown
Due 1 July 1991
Resolved 10 March 1992
Electrical
Issued 28 March 1991 Resolved
Prior to placing into service the 110 volt electric generator set along with the associated wiring arrangment, the plan submitted is to be reviewedand approved by this office and the completed installation package is to beexamined by a Coast Guard marine inspector.
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Lifesaving
Issued 20 April 1989 Resolved
PROVIDE 100 FOOT LINES FOR SEA PAINTERS AND ATTACH TO THE TWO LIFE FLOATS WITH A SPLICE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Construction/Loadline
Issued 20 April 1989 Resolved
PROVIDE CAPTIVE CHAINS OR LINES ON THE THREE (3) WEATHER DECK HATCHES.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989 Resolved
PROVIDE A COAST PILOT #3.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989 Resolved
PROVIDE A 1989 TIDE CHART.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
PROVIDE TWO (2) OARS FOR THE LIFE FLOATS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
MARK THE LIFE FLOAT OARS WITH THE VESSEL'S NAME.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 20 April 1989 Resolved
RENEW THE CONDUCTOR FROM THE BATTERY TO THE FUSE BLOCK IN ENGINE ROOM.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 20 April 1989 Resolved
REFIT THE BONDING WIRES O THE PROT SIDE IN THE LAZARETTE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 2 May 1987 Resolved
FIT OUT BOTH OF THE LIFEFLOATS WITH A PLATFORM THAT CAN BE SUSPENDED TO 36 INCHES BELOW THE CENTER OF THE FLOATS BODY BY A NET OR EQUIVALENT ARRANGEMENT (46 CFR 160.027.3A-E).
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Fire Fighting
Issued 2 May 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROPERLY DEMONSTRATE THE FIRE/BILGE PUMPING SYSTEMS.
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Navigation
Issued 29 April 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF COAST PILOT AND RULES OF THE ROAD.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Fire Fighting
Issued 8 May 1985 Resolved
SERVICE 3 BII DC FIRE EXTINGUISHERS. HOSES ON EACH NEED REPLACEMENT.
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985
Documentation
Issued 8 May 1985 Resolved
PROVIDE UP TO DATE CHARTS TO COVER ENTIRE ROUTE OF OPERATION.
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985

Casualty record · 4

14 July 2010Routine · role: Involved in a Marine Casualty · activity 3795488
18 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3802605
29 September 2012Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 4456224
5 July 2013Routine · role: Involved in a Marine Casualty · activity 4647895
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

NORTH STAR (2010–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.