MAURY USCG vessel records Sign in
← All vessels

ATLANTUS

ATLANTUS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1985, most recently in May 2018, along with 96 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2007 and 2018.

Records from 1985 to 2018. Most recent: inspection, 15 May 2018.

Built
1975
Last inspected
15 May 2018
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8920
Flag
UNITED STATES
366966490 (licence lapsed)
Maury page id
psix-53854

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1985–2018)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.7 ft × 15.5 ft × 6.4 ft
Registered tonnagegross 23 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILL'S BOAT WORKS · HARKERS Island, NC, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEA ISLE CITY, NJ
Trade endorsementsRecreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8920MMSI 366966490 · terminated · compulsorily equipped · granted 23 July 2004, cancelled 3 September 2014
WCE6229MMSI not assigned · expired · compulsorily equipped · granted 18 March 1994, cancelled 23 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

15 May 2018 Type not recorded
No type recorded · Station Cape May · USCG East District (CGD-E) · Activity 6415037
15 May 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6434128
26 September 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6009445
11 May 2016 Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5875153
1 September 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5232127
24 March 2014 Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4845806
6 February 2012 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4239293
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199655
1 July 2011 Type not recorded
No type recorded · USCG East District (dre) · USCG East District (CGD-E) · Activity 4073995
14 October 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3869319
8 March 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3691950
4 November 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3320774
2 June 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3225024
4 December 2007 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3109050
8 October 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3076246
8 October 2007 Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 3078049
12 July 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2992260
27 June 2007 Hull Examination · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2975457
17 October 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2802574
25 April 2006 Hull Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2632169
18 October 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2515919
12 May 2004 Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2183173
13 April 1999 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788338
30 October 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803161
29 September 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 801636
29 September 1998 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1446689
9 June 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 788129
10 December 1997 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 780463
1 August 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1097899
4 June 1996 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 876630
10 April 1995 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1149401
8 June 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324759
25 May 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1161729
25 May 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1423930
28 April 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858989
29 March 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858900
1 November 1993 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 834705
21 May 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1138969
28 May 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 944620
7 May 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 952505
18 June 1991 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1352028
19 April 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1231596
12 March 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 926590
2 April 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1214920
7 March 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 905285
21 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1039093
6 May 1988 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1205129
19 April 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208755
12 May 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1333337
23 April 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325012
12 May 1986 Re-Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301752
18 April 1986 Credit Drydock · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294620
22 November 1985 Deficiency Check · Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 995769
16 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983258
10 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983436
26 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 972705
26 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983433

Deficiency record · 96

Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 May 2016 No resolution recorded
Vessel missed 2015 annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Hull Plating
Issued 6 February 2012 Resolved
Prior to carrying passengers, perform underway inspection in presence of CG inspector, IAW local wood hull policy.
Action required: 705 - Other - as specified
Resolved 27 March 2012
Resolution: Performed underway inspection to check for weeps & leaks of wood hull. Found small leak around port side rudder post. Advised owner to repack. Vessel is fit for service.
Stability › Intact Righting Energy › General
Issued 1 December 2011 Resolved
Based on a new Assumed Average Weight per Person (AAWPP) of 185lbs per person. The new regulations came into effect on December 01, 2011 (Federal Register Vol. 75, No. 239). Based on the new AAWPP your vessel has been restricted to the following passenger count: 18 passengers, 2 crew.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Resolution: Received notification from master to reduce to 18 passengers and 2 crew indefinitely. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 October 2010 Resolved
Retroreflective tape damaged
Action required: 705 - Other - as specified
Resolved 25 October 2011
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2010 Resolved
Rotted stern planking stbd side
Action required: 705 - Other - as specified
Resolved 31 March 2010
Resolution: Repaired according to submitted repair proposal
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2010 Resolved
Water intrusion through stem/planking seam port side
Action required: 705 - Other - as specified
Resolved 14 June 2010
Resolution: Repaired according to submitted repair proposal
Construction/Loadline › Hull › Weld
Issued 8 March 2010 Resolved
Water intrusion through hull fastener port side
Action required: 705 - Other - as specified
Resolved 16 June 2010
Resolution: Removed and replaced with larger screw, sealed with West System Epoxy
Lifesaving › Lifefloat › Painter
Issued 4 November 2008 Resolved
The painter was not wrapped around the body of life float.
Due 14 November 2008
Resolved 25 November 2008
Resolution: The painter has been re-wrapped around the body of life float as instructed.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 4 November 2008 Resolved
The rotating belt of the engine does not have protective device to prevent people from touching it thus presents a possible hazard.
Condition: Unknown
Due 14 November 2008
Resolved 25 November 2008
Resolution: Means of protection around the rotating belt of the main engine have been put in place. Adequate protection is provided.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 4 November 2008 Resolved
Stream of water would leak into the hull when underway. Repair is required to be done to eliminate leakage.
Condition: Unknown
Due 14 November 2008
Resolved 25 November 2008
Resolution: Upon the deficiency check inspection, the leakage through shaft packing has been repaired.
Engineering › Steering Gear System › Rudder Stock
Issued 4 November 2008 Resolved
Water is leaking through the rudder post while boat is underway.
Condition: Unknown
Due 14 November 2008
Resolved 25 November 2008
Resolution: Upon the deficiency check inspection, the leakage of water through the rudder post has been repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 November 2008 Resolved
COI not properly posted according to the rule.
Due 14 November 2008
Resolved 25 November 2008
Resolution: Upon the deficiency check inspection, the COI has been properly posted.
Documentation › Certificates/Documents › Stability Letter
Issued 4 November 2008 Resolved
Stability letter was not properly posted per the rule.
Due 14 November 2008
Resolved 25 November 2008
Resolution: Upon the deficiency check inspection, the Stability Letter has been properly posted.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 November 2008 Resolved
Two adult life jackets were worn out and thus must be replaced.
Condition: Unknown
Due 14 November 2008
Resolved 25 November 2008
Resolution: Upon the deficiency check inspection, two new adult life jackets have been placed aboard the vessel.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 November 2008 Resolved
Aft bilge alarm fails to activate during the test. Repair must be made prior to carry any passengers.
Due 14 November 2008
Resolved 25 November 2008
Resolution: Bilge alarm has been repaired and tested satisfactorily during the deficiency check inspection.
Construction/Loadline › Structures › Deck Plating
Issued 4 November 2008 Resolved
A piece of wood that supports the shaft strut through hull located on port side aft of fuel tank is found to be rotten and thus must be replaced with a plank that can provide adequate strength. ( see narrative of activity #3320774, deficiency# 10 )
Condition: Improper Installation
Due 14 November 2008
Resolved 25 November 2008
Resolution: A new block was placed, the wood underneth the block was solid.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 November 2008 Resolved
Life jacket donning placard is missing.
Due 14 November 2008
Resolved 25 November 2008
Resolution: Life jacket donning placard has been properly posted.
Communications › Radio Communications › EPIRB
Issued 4 November 2008 Resolved
NOAA registration is not available on EPIRB. It must be provided before traveling beyond 3 NM from shore.
Due 14 November 2008
Resolved 25 November 2008
Resolution: NOAA registration has been made available on EPIRB upon the deficiency check inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 June 2008 Resolved
Renew broken clamp at stbd exhaust thru-transom penetration to hose connection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Resolution: Owner installed new hose clamp.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 2 June 2008 Resolved
Replace broken fuel line on the port main engine and replace fuel soaked insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Resolution: Owner installed new fuel line, all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2008 Resolved
Provide navigation lights configured to be in compliance with the Nav Rules Prior to operating at night.
Action required: 705 - Other - as specified
Resolved 1 July 2008
Resolution: Received picture noting proper installation of navigational lights, all sat.
Engineering › Generator (propulsion-electric) › Wiring
Issued 11 December 2007 Resolved
Prove proper operation of the generator to the satisfaction of a marine inspector prior to operating it. The generator is out of commission, does not have J1942 hoses and is not connected to the Fixed Firefighting system for automatic shutdown as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 8 September 2009
Resolution: Generator has been removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 4 December 2007 Resolved
The vessel's starboard MDE was not operating. The vessel must prove proper operation of starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Resolution: Performed satisfactory test ride, MDE appeared to be properly functioning.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 December 2007 Resolved
Vessel did not have proof of drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 17 April 2008
Resolution: Verified records that drills had been conducted, as well as conducting drills while on board.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 December 2007 Resolved
The vessel's eye wash had expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Resolution: Verified expiration date of new eye wash.
Lifesaving › Hand Flares › Expired
Issued 4 December 2007 Resolved
Vessel must replace expired flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 17 April 2008
Resolution: Verified new flares were onboard.
Electrical › Electric Supply System (service) › Cable
Issued 4 December 2007 Resolved
Observed several loose/dead/extra wires in e/r compartment. The vessel must organize the wiring, remove 3 dead wires and replace the broke metal supports.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 17 April 2008
Resolution: Verified that the dead wires had been removed, the existing wires were more organized and the metal supports had been replaced.
Documentation › Logs/Records › Drug Test Records
Issued 27 June 2007 Resolved
It was discovered the owner failed to renew crewmembers enrollment into drug consortium. Crewmembers enrollment expired on the 25 May 2007 and had not been renewed until the 26 June 2007. However, the vsl operated multiple times during this period. In addition, it was discovered one crewmember was not enroll in the same consortium as the other crewmembers.
Action required: 705 - Other - as specified
Due 27 June 2007
Resolved 27 June 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 June 2007 Resolved
Vsl not to operate w/ passengers until all f/f equipment properly serviced and proof provided to MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2007
Resolution: F/F equipment properly serviced.
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 26 June 2007 Resolved
Vsl not to operate w/ pax until satisfactory operation of port MDE proven and u/w check ride performed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2007
Resolution: Observed port MDE in operation while underway, tested fwd & reverse, All SAT.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 June 2007 Resolved
Vsl to provide means to pump forepeak w/in 30 days. (provide proposal prior to repairs).
Condition: Placed in Improper Service
Due 26 July 2007
Resolved 4 December 2007
Resolution: Vessel O/O purchased a portable hand pump that would was long enough to fit through opening to remove water from forpeake.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 30 October 2006 Resolved
Complete repairs to fwd lazarette hatch prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2007
Resolution: Observed photos of repaired hatch with confirmation from owner that hatch is water tight. All Sat.
Communications › Radio Communications › EPIRB
Issued 17 October 2006 Resolved
Hydrostatic release mechanism and NOAA registration expired. Vessel restricted to w/in 3mi. until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: New hydrostaticrelease mechanism installed w/ valid dates and registration updated.
Navigation › Piloting/Steering › Marine Charts
Issued 17 October 2006 Resolved
Chart #12318 not corrected and is outdated edition. Rules of the Road not available.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 6 May 2007
Resolution: Observed photos of nav rules and corrected chard #12318 on board vessel.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 October 2006 Resolved
(2) lifejacket lights did not operate. Passenger count reduced to (22) for oceans route until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 30 October 2006
Resolution: (2) additional lifejacket lights provided.
Deck/Cargo › Holds/Tanks › Hatch
Issued 17 October 2006 Resolved
Excessive rot was discovered around forward lazarette hatch and on hatch. O/O required to submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 6 May 2007
Resolution: Observed photos of satisfactory repaired hatch and owner confirmed hatch water tight, all sat.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 October 2006 Resolved
Vessel name missing letter "L".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 30 October 2006
Resolution: Vessel name corrected to show proper vessel name on port bow.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 October 2006 Resolved
Water light expired and did not operate. Vessel restricted from operating after sunset until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: New waterlight provided that operated satisfactorily.
Engineering › Steering Gear System › Rudder Bearing
Issued 17 October 2006 Resolved
Stbd. side rudder stuffing box leaked excessively at dock and while underway.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 30 October 2006
Resolution: Leak satisfactorily stopped.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 October 2005 Resolved
Provide two child size PFD's. Vessel may not carry more than one child until requirement is met.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 25 May 2006
Resolution: Attended vessel. All required PFD''s are on board.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 October 2005 Resolved
Provide 7 adult size PFD's. Vessel may not carry more than 17 adults until requirement is met.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 25 May 2006
Resolution: Attended vessel. All required PFD''s are on board.
Fire Fighting › Fire Bucket › Quantity
Issued 18 October 2005 Resolved
Provide (3) 2.5 gallon fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2005
Resolved 25 May 2006
Resolution: Attended vessel. Required fire buckets are on board.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 October 2005 Resolved
Pre-engineered system does not automatically shut down generator when activated. Vessel not to use generator until requirement is met.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 19 April 2007
Resolution: Combined w/requirement issued under activity #3109050.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 October 2005 Resolved
Repair bilge high level alarm indicators so that they indicate proper location of activation.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 June 2006
Resolution: All new bilge alarms and float switches installed and tested sat.
Communications › Radio Communications › EPIRB
Issued 18 October 2005 Resolved
Relocate EPIRB to an uncovered area where it will be float free.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 25 May 2006
Resolution: Attended vessel. EPIRB has been relocated to an unobstructed area.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 September 2004 Resolved
Provide 6 more life jackets prior to carrying more than 16 passengers and 2 crew.
Due 8 October 2004
Resolved 25 May 2006
Resolution: Attended vessel. All required PFD''s are on board.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 30 October 1998 Resolved
Provide plans for installing fixed fire fighting system required prior to 11 March 1999.
Condition: Unknown
Due 11 March 1999
Resolved 8 September 2004
Resolution: Installed a pre engineered fixed fire extinguishing system.
Lifesaving
Issued 29 September 1998 Resolved
Prove proper operation of water light on buoyant apperatus.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Engineering
Issued 29 September 1998 Resolved
Install double nuts on shaft packing.
Condition: Unknown
Due 29 October 1998
Resolved 2 October 1998
Lifesaving
Issued 29 September 1998 Resolved
Total maximum persons limited to 15 until failed PFD is replaced.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Electrical
Issued 29 September 1998 Resolved
Remove dead end wires from consoles on both decks.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Fire Fighting
Issued 29 September 1998 Resolved
Install brackets for 2 BII fire extinquishers.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Electrical
Issued 29 September 1998 Resolved
Remove or repair wiper motor from starboard side port light.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Lifesaving
Issued 29 September 1998 Resolved
Post donning instructions for PFDs.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Accommodation/Occupational Safety
Issued 29 September 1998 Resolved
Repair bracket in forward acom space to make overhead hatch watertight.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Accommodation/Occupational Safety
Issued 29 September 1998 Resolved
Provide dogging screw for port light on starboard side in forward acom space.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Electrical
Issued 29 September 1998 Resolved
Provide protective cover for light in forward acom space.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Electrical
Issued 29 September 1998 Resolved
Provide protective covers for lights in aft acom space.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Documentation
Issued 29 September 1998 Resolved
Provide copy of current 47 CFR Part 80.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Fire Fighting
Issued 29 September 1998 Resolved
Provide plans for installing fixed fire fighting system required prior to 11 March 1999.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Accommodation/Occupational Safety
Issued 29 September 1998 Resolved
Tighten railing hold down screws as necessary.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 September 1998 Resolved
Install bilge high level alarm provide plans prior to installation.
Condition: Unknown
Due 11 March 1999
Resolved 8 September 2004
Resolution: Installed high level alarm.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 29 September 1998 Resolved
Provide EPIRB floatfree 1.406 MHZ prior to 1FEB99.
Condition: Unknown
Due 1 February 1999
Resolved 8 September 2004
Resolution: Provided an EPIRB.
Lifesaving
Issued 29 September 1998 Resolved
Provide type II retro reflective tape on the ring buoy.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Construction/Loadline
Issued 10 December 1997 Resolved
COMPLETE A CREDIT DRYDOCK EXAM TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS AFTER 30 NOVEMBER 1997.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Engineering
Issued 1 August 1997 Resolved
MAKE PROPER REPAIRS TO TRANSMISSION LINKAGE
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 1 August 1997 Resolved
VSL RESTRICTED FROM OPERATING WITH PASSENGERS MORE THAN 3 MILES FROM SHORE UNTIL EPIRB BATTERY IS REPLACED
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Lifesaving
Issued 1 August 1997 Resolved
VSL NOT TO CARRY PASSENGERS UNTIL ITEM #0002 ISSUED 28MAR97 HAS BEEN INSPECTED & A CHECK RIDE CONDUCTED IN THE PRESENCE OF A CG INSPECTOR
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Fire Fighting
Issued 10 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE 1 USCG APPROVED B-II TYPE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 10 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE CLEAN MACHINERY COMPARTMENT BILGE OF OIL.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Navigation
Issued 10 April 1995 Resolved
PRIOR TO OPERATING AT NIGHT OR IN REDUCED VISIBILITY CLEAN, REPAIR & RENEW LENS OF THE STARBOARD NAVIGATION LIGHT.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Navigation
Issued 10 April 1995 Resolved
PRIOR TO OPERATING AT NIGHT OR IN REDUCED VISIBILITY, RENEW STERN LIGHT LENS.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 10 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE RENEW INNER LIFELINE ON LIFEFLOAT.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Navigation
Issued 10 April 1995 Resolved
PROVIDE UPDATED NAVIGATION CHARTS 12318 AND 12323._x001C_
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Electrical
Issued 10 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE REPAIR 12 VOLT TERMINAL ON TERMINAL BLOCK LOCATED ON THE FORWARD BULKHEAD IN FUEL TANK COMPARTMENT.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Electrical
Issued 25 May 1994 Resolved
REMOVE DEAD-END ELECTRICAL WIRING AT THE WIRING HARNESS ADJACENT TO THE PORT SIDE OF THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 25 May 1994 Resolved
MAKE THE MAIN DECK WATERTIGHT AT THE PORT FORWARD CLEAT (LEAKS INTO BOW VOID).
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 25 May 1994 Resolved
REPLACE THE SUPPORT BRACKET FOR THE JABSCO BILGE PUMP ON THE PORT FORWARD ENGINEROOM BULKHEAD.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 25 May 1994 Resolved
SCRAPE AND TREAT BOTTOM PLANKING AFT OF THE PORT ENGINE.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Unknown
Issued 25 May 1994 Resolved
REPLACE THE WASHDOWN PUMP INTAKE VALVE.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 29 March 1994 Resolved
PRIOR TO CARRYING PASSENGERS MORE THAN 1,000 FEET FROM SHORE, PROVIDE A_x001C_ VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Navigation
Issued 29 March 1994 Resolved
PROVIDE A CURRENT COMPASS DEVIATION TABLE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Documentation
Issued 29 March 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICALDRUG TESTING REQUIREMENTS OF 46 CFR 4, 5, & 16.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 21 May 1993 Resolved
UPON COMPLETION OF REPAIRS TO AUX. GENERATOR, DEMONSTRATE PROPER OPERATION OF THE SAME UNDER LOAD.
Condition: Unknown
Due 18 June 1993
Resolved 18 June 1993
Accommodation/Occupational Safety
Issued 28 May 1992 Resolved
MAKE REPAIRS TO THE MSD HOLDING TANK PUMP. ENSURE THAT THE OVERBOARD DISCHARGE VALVE IS SECURED UNTIL REPAIRS ARE MADE OR THE VESSEL IS MORE THAN 3 MILES OFFSHORE.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Lifesaving
Issued 28 May 1992 Resolved
SUPPLY THE REQUIRED IDENTIFICATION TAG FOR THE LIFEFLOAT WEAK LINK.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Navigation
Issued 28 May 1992 Resolved
TIGHTEN THE PACKING ON THE PORT RUDDER STOCK TO STOP LEAKAGE.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Engineering
Issued 28 May 1992 Resolved
REPLACE THE FUEL SUPPLY HOSES FOR THE MAIN DIESEL ENGINES AND GENERATOR WITH AN APPROVED TYPE.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Navigation
Issued 19 April 1991 Resolved
PROPERLY DISPLAY THE ANCHOR LIGHT AS OUTLINED IN RULE 30 OF THE INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA, _x001C_ (COLREGS, 33CFR PART 81)
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE TWO PADDLES FOR THE LIFE- FLOAT AS REQUIRED BY 46CFR180.15-1.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 6 May 1988 Resolved
SHOW PROOF THAT A PROPER FCC SAFETY CERTIFICATE HAS BEEN ISSUED FOR 100 MILE SERVICE. (ORIGINAL COMPLIANCE DATE IS 06JUN88)
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 16 May 1985 Resolved
PROVE PROPER OPERATION OF ALARMS AND PORT ENGINE EGNITION SWITCH ON FLYING BRIDGE.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Lifesaving
Issued 16 May 1985 Resolved
PROVE PROPER OPERATION OF VESSEL'S EPIRB.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Construction/Loadline
Issued 16 May 1985 Resolved
MAKE AVAILABLE FOR INSPECTION THE WASHDOWN PUMP INSTALLTION.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Engineering
Issued 26 April 1985 Resolved
PERFORM HYDROSTATIC TEST AT 5 PSI ON THE PORT FUEL TANK. UPON COMPLETION OF HYDRO, PERFORM INSTALLATION TEST.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Construction/Loadline
Issued 26 April 1985 Resolved
SUBMIT PROPOSAL ON RENEWING DECK BEAMS OVER PORT FUEL TANK PRIOR TO COMMENCING PERMANENT REPAIRS. REPAIRS ARE TO BE COMPLETED PRIOR TO NEXT OPERATING SEASON.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985

Casualty record · 2

8 October 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3076246
15 May 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6434128
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.