Records from 1984 to 2012. Most recent: operational control imposed, 4 February 2012.
Inspection history · 105
4 February 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4238186
2 February 2012
Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4236792
17 September 2011
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4142840
8 December 2010
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3906565
26 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3683755
2 February 2010
MARPOL Annex VI Survey · ISPS III Exam · MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3673480
9 December 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3647372
9 February 2009
COC-CHEM Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3415246
7 January 2009
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387781
11 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3378390
11 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3401503
10 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3360674
26 August 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3309674
15 May 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3207425
8 February 2008
MARPOL Annex I Examination · MARPOL Annex II Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3141328
14 March 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2887195
5 February 2007
ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2866451
27 October 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2809112
21 October 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2805094
5 April 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2617278
7 February 2006
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2580699
3 February 2006
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2574647
18 October 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2517467
6 August 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2453094
10 July 2005
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2415220
5 February 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2288493
29 January 2005
Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2282861
23 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263959
22 December 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2263553
20 November 2004
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2244903
28 September 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2207240
24 May 2004
MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2077031
6 February 2004
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2000327
28 May 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1804203
28 February 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1755720
8 January 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1727367
30 January 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1482161
16 January 2002
Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1479166
30 November 2001
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 295725
29 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293340
25 May 2001
Port Security Assessment
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 557976
13 February 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 286861
13 February 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1058717
17 July 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 279955
15 May 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 277844
11 April 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 276542
1 February 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 274333
24 January 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 273793
24 January 2000
Letter of Compliance (Initial/Renewal)
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 821964
13 October 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 433471
3 June 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 429023
9 April 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 99302
11 January 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 424281
31 December 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 423937
31 December 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 811189
14 October 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 508917
17 April 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 414463
2 January 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 411348
2 January 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 783655
6 October 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 408758
7 March 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 448173
4 February 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 775910
8 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1090973
16 January 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 386679
16 January 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1088803
16 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381745
7 March 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1170802
16 January 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1187387
16 November 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 372398
29 April 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 366377
7 January 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 363504
6 January 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1366945
24 April 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 357907
5 April 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 436889
12 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 539676
12 September 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1258238
28 April 1992
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 78091
28 April 1992
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 350304
31 March 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949994
19 October 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 480632
9 April 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 343043
9 April 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 908703
31 December 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 498379
30 September 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 339658
28 March 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 335995
28 March 1990
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 919861
3 January 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 530977
28 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 331724
28 July 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196173
31 March 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 487291
5 October 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 505418
1 July 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 895356
2 June 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 323594
2 June 1988
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1197697
15 October 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 318890
15 October 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1324046
27 August 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320557
8 July 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020323
13 May 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 517004
25 July 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 310516
25 July 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1295733
2 April 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 457368
5 October 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 538087
13 February 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300425
6 August 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281834
Engineering › Steam System (main) › Piping
Issued 2 February 2012
Resolved
The gasket for the cargo/ ballast steam supply lines is wasted and leaking. This steam leak is located above the main boiler downstream of the main steam stop valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2012
Resolution: Received Class report attesting to proper repairs for the steam leak. Class report is attached in documents.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 February 2012
Resolved
The fire control plan should clearly show "A" and "B" Class Divisions. The legend of the fire control plan does not depict the actual symbols on the plan itself. (e.g. "A" and "B" Class doors, fire boundries).
Action required: 705 - Other - as specified
Due 8 March 2012
Resolved 14 March 2012
Resolution: 14MAR12: Conducted a Deficiency Check via email from Class attesting to proper repairs of the fire control plan. Class report is attached in documents.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 2 February 2012
Resolved
Prior to discharging regulated cargo in U.S. Waters, the evergency cargo pump shutdowns need to be tested.
Action required: 705 - Other - as specified
Due 25 March 2012
Resolved 25 March 2012
Resolution: PSCO officers witnessed proper operation of the emergency shutdowns during Def Check.
Engineering › Steering Gear System › Valve
Issued 2 February 2010
Resolved
0936- Steering gear- The PSCO observed hydraulic oil leaking from pilot operated valve; it was leaking approx. 45 drops per minute; the leak was not being maintained and hydraulic oil was collecting on the deck.- SOLAS 74(a) 2004 cons. I/26.
Action required: 705 - Other - as specified
Due 9 February 2010
Resolved 5 February 2010
Resolution: Received, reviewed and approved class report from Lloyd''s Register clearing deficiency. Class report stated: leaking control valve #2 was replaced; steering gear was tested satisfactorily.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 11 December 2008
Resolved
Received report that the vessel experienced a loss of propulsion. Prior to departure the vessel must submit documentation from the certificate issuing authority attesting to the nature of the problem and corrective action as been taken.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2009
Resolution: Received class report attesting to the nature of the problem and that corrective action has been taken. Operational control has been removed. Class report has been scanned into activity, see report for further details.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 November 2008
Resolved
Received inbound deviation request for an inoperable secondary marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2008
Resolution: Received technician report attesting to the proper repairs and operation of the vessel''s secondary marine radar system.
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 8 February 2008
Resolved
The national license for the first assistant engineer does not show the correct STCW qualification.
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 11 February 2008
Resolution: Received, reviewed and accepted Letter of Dispensation for the Flag State Liberia allowing to the vessel to sail to its next port of call. The LOD expires on 29 FEB 08.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2007
Resolved
Cargo and ballast pump moving parts are unguarded and exposed. Lacks adequate protection for crew members. Deficiency to be addressed to the attending classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2007
Resolution: PSC NOLA received a class report stating that guard rails are satisfactorily installed on all ladders and platforms in way of the pump rooms.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 5 February 2007
Resolved
Cargo record book not updated in accordance with MARPOL Annex II 2004 revisions.
Due 5 February 2007
Resolved 5 February 2007
Resolution: Deficiency rectified on the spot.
Operations/Management › Cargo Transfer/Lightering › Cargo Tank Stripping
Issued 5 February 2007
Resolved
Starboard side stripping pump in pump room leaking water excessively from top fitting of shaft into bilge. To be addressed to the attending classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2007
Resolution: PSC NOLA received a class report stating that the Port and Starboard Pumps were found to be free of leaks and that repairs made by Chief Engineer are satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 5 February 2007
Resolved
Cargo handling room has lighting that is not explosion proof. Deficiency is to be rectified to the satisfaction of attending classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2007
Resolution: PSC NOLA received a class report stating that the cargo handling room electrical lighting is the original equipment installed by the shipyard and is approved.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 February 2006
Resolved
Master of the M/V SENTINEL II requested a Letter of Deviation to enter the Port of Point Comfort with an inoperable Echo Depth Sounder. Cause was determined to be a burned up input power transformer. Parts to effect repairs are no longer available. Company has sent a replacement echo depth sounder which will be fitted on the vessel at the Next Port of Call, Lake Charles.
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 7 February 2006
Resolution: Vessel has installed a new echo depth sounder. MSU Lake Charles received a class report attesting to these repairs and cleared the deficiency.
Construction/Loadline › Markings › Load Line Mark
Issued 20 November 2004
Resolved
Loadline and draft markings must be painted a contrasting color to the hull of the vessel. (ICLL 66 Annex 1/8).
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 30 January 2005
Resolution: Verified loadline to have contracting color under ICLL 66 Annex 1/8.
Lifesaving › Lifebuoys
Issued 6 February 2004
Resolved
Replace 5 life buoys due to rotted beckets, SOLAS 74 Ch3 reg 21(d) prior to 9 Feb 2004. LEGACY COMPONENT DESC: Beckets
Due 9 February 2004
Resolved 9 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 8 January 2003
Resolved
Explosimeter failed testing. Have meter calibrated and fax report to COTP Baltimore prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2003
Resolved 9 January 2003
Resolution: RECEIVED FAX FROM RS STERN ATTESTING TO THE REPAIR OF METER.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 January 2002
Resolved
REPAIR WATER SUPPLY LINE TO FWD EYE WASH STATION LOCATED AT HOLD #3 LEGACY COMPONENT DESC: EYE WASH
Condition: Improper/Lack of Maintenance
Due 22 February 2002
Resolved 30 January 2002
Resolution: Item corrected.
Lifesaving › Lifeboat Equipment
Issued 16 January 2002
Resolved
REPLACE MISSING FOOD RATIONS FOR LIFEBOATS 9 TOTAL. LEGACY COMPONENT DESC: Food Ration
Condition: Improper Installation
Due 22 January 2002
Resolved 24 January 2002
Resolution: RECEIVED FAXED RECIEPT FOR RATIONS.
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 January 2002
Resolved
HOSPITAL SPACE NOT TO BE OCCUPIED IAW ILO-147. LEGACY COMPONENT DESC: Hospital Space
Condition: Placed in Improper Service
Due 22 January 2002
Resolved 24 January 2002
Resolution: CREW WAS MOVED OUT OF SPACE INTO EMPTY QUARTERS.
Deck/Cargo
Issued 25 May 2001
Resolved
Prior to departure from port provide a class report attesting to suitability of vessel in its current carriage of containerized cargo on weather decks and cargo hold covers, also addressing current lashing arrangements, stability, and deck cover strengths. 74 SOLAS I/11
Condition: Unknown
Due 31 May 2001
Resolved 4 June 2001
Deck/Cargo
Issued 25 May 2001
Resolved
Prior to departure from port provide a class report attesting to suitablitity of vessel in its current carriage of break bulk and containerized cargo in bulk cargo holds, also addressing current lashing arrangements. 74 SOLAS I/11
Condition: Unknown
Due 31 May 2001
Resolved 4 June 2001
Deck/Cargo
Issued 25 May 2001
Resolved
Prior to departure from port provide an approved cargo securing manual if sailing with containerized cargo._x001C_ 74 SOLAS Ammended VI/6
Condition: Unknown
Due 31 May 2001
Resolved 4 June 2001
Fire Fighting
Issued 25 May 2001
Resolved
Prior to departure from port provide determination from Flag Administrationwith respect to lack of fixed fire fighting systems in the cargo holds._x001C_ 74 SOLAS (81 Ammended) II-2/52 (f)
Condition: Unknown
Due 31 May 2001
Resolved 4 June 2001
Lifesaving
Issued 24 January 2000
Resolved
FWD EMERGENCY WASH DOWN NOT WORKING PROPERLY. (MAYBE RESULT OF COLD WEATHER) INSURE PROPER OPERATION PROIOR TO LOADING CARGO.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Navigation
Issued 13 October 1999
Resolved
SECONDARY RADAR INOP.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Deck/Cargo
Issued 31 December 1998
Resolved
LIFE BOAT DAVIT BRAKES NOT OPERATING PROPERLY.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 31 December 1998
Resolved
LIFE BOAT LAUNCHING INSTRUCTION NOT POSTED.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 31 December 1998
Resolved
LIFERAFT INSTUCTION NOT POSTED.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Engineering
Issued 2 January 1998
Resolved
THE CONDENSATE OVERBOARD (BOILER BLOWDOWN) ON STBD AFT ENGINEROOM HAS BEEN LEAKING. A TEMPORARY CEMENT BOX REPAIR WAS DONE. REQUEST TO HAVE CLASS SOCIETY PROVIDE REPORT ON SATISFACTORY CONDITION OF TEMPORARY REPAIR AND DELIVER TO LOCAL OCMI.
Condition: Unknown
Due 2 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 7 March 1995
Resolved
PROVIDE FIREPROOF LIFELINES FOR FIRE LOCKERS IN ACCORDANCE WITH SOLAS II-2 REG 17 AND 46 CFR 35.30-20(e).
Condition: Unknown
Due 7 March 1995
Resolved 10 March 1995
Electrical
Issued 7 March 1995
Resolved
DEMONSTRATE OPERATION OF THE EMERGENCY FUEL SHUTOFF REACH ROD FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 7 March 1995
Resolved 10 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
PROVIDE SUITABLE FLASHLIGHTS IN THE FIRE AND SAFETY GEAR LOCKERS AS REQUIRED BY 46 CFR 35.30-20(c)(3) AND 46 CFR 153.214. CURRENT FLASHLIGHTS ARE NOT EXPLOSION PROOF.
Condition: Unknown
Due 7 March 1995
Resolved 10 March 1995
Navigation
Issued 16 November 1994
Resolved
A VIOLATION OF 33 C.F.R. 164.35(a) IN THAT THE VESSEL'S SECONDARY MARINE RADAR WAS INOPERATIVE UPON ARRIVAL IN THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 16 November 1994
Resolved 17 November 1994
Navigation
Issued 7 January 1994
Resolved
VESSEL WAS ISSUED A LETTER OF DEVIATION TO ENTER HAMPTON ROADS WITH AN INOPERABLE ARPA.
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Electrical
Issued 6 January 1994
Resolved
REMOVE DEAD END WIRE ON PORT SIDE STEERING ROOM. COMPLETE PRIOR TO ARRIVAL AT NEXT U.S. PORT.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Lifesaving
Issued 6 January 1994
Resolved
PROVIDE WEAK LINKS FOR PORT & STBD LIFERAFTS. COMPLETE PRIOR TO DEPARTING THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Navigation
Issued 30 September 1990
Resolved
33CFR164.38(b)(1) VESSEL ENTERED PORT OF CORPUS CHRISTI WITHOUT A PROPERLYOPERATING AUTOMATIC RADAR PLOTTING AID OR ARPA AS REQUIRED BY 33CFR164.11(r)._x001C_ _x001C_
Condition: Unknown
Due 30 September 1990
Resolved 30 September 1990
Deck/Cargo
Issued 28 March 1990
Resolved
REPLACE ALL FIBERGLASS TANK CLEANING HATCHES WITH STEEL.
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Documentation
Issued 8 July 1987
Resolved
SUBMIT NEW PERMANENT COF TO USCG (G-MTH-1) AND PLACE ONBOARD A VALID CARGO AND RESTRICTIONS LIST.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987