MAURY USCG vessel records Sign in
← All vessels

FUJIKAZE NO. 3

FUJIKAZE NO. 3 is a 1977 tank ship. The Coast Guard has recorded 18 inspections since 1984, most recently in January 1989, along with 49 deficiencies.

Records from 1984 to 1989. Most recent: inspection, 27 January 1989.

Built
1977
Last inspected
27 January 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7501443 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-53876

Inspections, by type

…with no type recorded14
Years with a record 6 calendar years (1984–1989)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4918 - Regulatory (Subpart C or D), Gross Ton
3442 - Regulatory (Subpart C or D), Net Ton
8489 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

27 January 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328115
27 January 1989 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034765
22 July 1988 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1342613
13 July 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324424
4 November 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 523653
5 May 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 493757
1 May 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1322289
29 April 1987 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1011656
13 March 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 314837
13 March 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1322624
19 December 1986 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1006527
14 August 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310822
15 May 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501702
23 May 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 302160
6 December 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1286054
21 November 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 299145
21 November 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1284306
12 July 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 506084

Deficiency record · 49

Accommodation/Occupational Safety
Issued 13 July 1988 Resolved
VESSEL DISCHARGING RAW SEWAGE INTO U.S. WATERS.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Documentation
Issued 13 March 1987 Resolved
MAKE REQUIRED ENTRIES IN OIL RECORD BOOK AT EACH OCCURRENCE OF THE MACHINERY SPACE OR CARGO BALLAST OPERATIONS AS LISTED IN MARPOL 73/38 APPENDIX III.
Condition: Unknown
Due 13 March 1987
Resolved 13 March 1987
Deck/Cargo
Issued 13 March 1987 Resolved
PRIOR TO NEXT CARGO DISCHARGE, TEST CARGO PUMP RELIEF VALVES.
Condition: Unknown
Due 13 March 1987
Resolved 13 March 1987
Fire Fighting
Issued 13 March 1987 Resolved
PRIOR TO NEXT CARGO TRANSFER OPERATION PROVIDE SATISFACTORY REPLACEMENT FIREFIGHTING FOAM.
Condition: Unknown
Due 13 March 1987
Resolved 13 March 1987
Documentation
Issued 19 December 1986 Resolved
PROVIDE RECORD OF TESTS AND INSPECTION OF OIL TRANSFER EQUIPMENT REQUIRED IN 33 CFR 156.170 IN ACCORDANCE WITH 33 CFR 155.820
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Fire Fighting
Issued 19 December 1986 Resolved
PROVIDE ANALYSIS OF FIRE FIGHTING FOAM.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Fire Fighting
Issued 19 December 1986 Resolved
MAKE PERMANENT REPAIRS TO FIRE FIGHTING FOAM PIPING IN WAY OF PORT HOUSE FOAM MONITOR.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Deck/Cargo
Issued 19 December 1986 Resolved
MAKE PERMANENT REPAIRS TO ALL CARGO TANK HEATING SYSTEM PIPING.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Navigation
Issued 14 August 1986 Resolved
COAST PILOT 7, 1984 EDITION, ONLY CORRECTED THRU NTM 52/84.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Documentation
Issued 14 August 1986 Resolved
VESSEL DID NOT HAVE AN OIL RECORD BOOK PART II (CARGO OPERATIONS). VESSEL WAS MAINTAINING THE OLD FORMATTED VERSION OF THE PANAMANIAN OIL RECORD BOOK
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Navigation
Issued 14 August 1986 Resolved
VESSEL HAD NO INLAND NAVIGATION RULES ABOARD.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 14 August 1986 Resolved
TOXIC GAS DETECTION TUBES EXPIRED.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 14 August 1986 Resolved
CALIBRATION GAS FOR THE REQUIRED OXYGEN INDICATORS NOT ON BOARD.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 14 August 1986 Resolved
ONE OF THE TWO REQUIRED OXYGEN INDICATORS IS NOT OPERATIONAL.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Navigation
Issued 14 August 1986 Resolved
WHEELHOUSE AND BRIDGE WING RUDDER ANGLE INDICATORS READING FROM 5 TO 17 DEGREES OFF FROM ACTUAL RUDDER POSITION.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 14 August 1986 Resolved
FLAME SCREENS NEED REPLACING IN THE #3S CARGO TANK VENT, #4P CARGO TANK VENT, & #4S CARGO TANK VENT.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Fire Fighting
Issued 21 November 1984 Resolved
TWO FWD DECK HOUSE AND ONE MIDSHIPS FOAM MONITORS CANNOT BE SHUT OFF AND CONTINUE TO SPRAY WATER IF FIRE PUMP IS OPERATING.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
VSL COULD NOT PROVIDE DOCUMENTATION THAT VALVES IN CARGO VENTILATION SYSTEMHAD VACUUM PROTECTION.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Fire Fighting
Issued 21 November 1984 Resolved
HAND WHEEL ON FWD FIRE HYDRANT BROKEN AND VALVE FROZEN CLOSED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Fire Fighting
Issued 21 November 1984 Resolved
FWD FOAM MNITOR UNABLE TO PRODUCE WATER.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Fire Fighting
Issued 21 November 1984 Resolved
NO. 1 FIRE PUMP IS NOT OPERATIONAL DUE TO BAD BEARINGS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
STEERING MACHINERY REQUIRES ADDITION/RENEWAL OF ALL KEEPER PINS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
MAGNETIC COMPASS TO BE ADJUSTED AND A CURRENT DEVIATION TABLE DEVELOPED (DURING DEPARTURE FROM PORTLAND)
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
COAST PILOT NO. 7, PACIFIC COAST, 1983 EDITION WITH NO CORRECTIONS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
U.S. LIGHT LIST, VOL. III, 1983 EDITION, NOT CORRECTED UP-TO-DATE.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
CHARTS USED TO NAVIGATE THE COLUMBIA RIVER, TO PORTLAND, OREGON, WERE OLD EDITIONS AND NOT CORRECTED UP-TO-DATE.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Electrical
Issued 21 November 1984 Resolved
NO. 1 GENERATOR CANNOT FUNCTION DUE TO DIRTY FILTERS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
CARGO MANIFOLD CONTAINMENT DRAIN PLUGS MISSING.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Engineering
Issued 21 November 1984 Resolved
FUEL CONTAINMENT MISSING PLUGS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Construction/Loadline
Issued 21 November 1984 Resolved
FIXED CONTAINMENT FOR STBD LUBE OIL TANK AND PORT SETTLING TANKS HAVE PINHOLE LEAKS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Unknown
Issued 21 November 1984 Resolved
SOFT PATCH ON STARBOARD SLOP TANK VENT PIPING NEEDS REPAIRED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
FORWARD PUMPROOM VENTILATOR MOTOR NOT OPERATIVE.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
CARGO PUMP EMERGENCY SHUT DOWN LOCATED ON STARBOARD HOUSE INOPERATIVE DUE TO CUT WIRING.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
PV VALVES ON NO. 2 PORT AND STARBOARD CARGO TANKS HAVE TORN RUBBER BLADDERSAND FROZEN SHAFTS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Construction/Loadline
Issued 21 November 1984 Resolved
GASKET RETAINER ON AFT PUMPROOM DOOR WASTED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
DAMPER IN STARBOARD PUMPROOM VENTILATOR RISER WASTED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
PUMPROOM VENTILATOR DUCTS DO NOT HAVE 30X30 MESH FLAME SCREENS.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
ALL PV VALVES NEED TO BE OPENED AND PERIODIC MAINTENANCE PERFORMED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Engineering
Issued 21 November 1984 Resolved
ALL GOOSENECK VENT CLOSURES FOR FUEL TANKS AND OTHER COMPARTMENTS SEIZED UP
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
STUFFING FOR ELECTRICAL CONNECTIONS TO LIGHT FIXTURES WASTED IN CARGO PUMP CONTROL ROOM.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
ALL FLAME ARRESTORS ON VENT MASTS CLOGGED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
STEAM PIPING ON DECK WASTED.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Fire Fighting
Issued 21 November 1984 Resolved
SOFT PATCH ON FOAM PIPING SYSTEM ADJACENT TO FOAM TANK WORN.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Fire Fighting
Issued 21 November 1984 Resolved
FOAM SAMPLE REQUIRED TO BE SUBMITED FOR ANALYSIS TO VERIFY FOAM STILL GOOD.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Accommodation/Occupational Safety
Issued 21 November 1984 Resolved
CHEMICAL PUMP CONNECTION ON MARINE SANITIATION DEVICE INOP. MSD BYPASSED BY ADDED PIPING AROUND MSD.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Documentation
Issued 21 November 1984 Resolved
VESSEL MISSING OIL DISCHARGE PROHIBITED PLACARD
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Documentation
Issued 21 November 1984 Resolved
PROVIDE IMO CODE FOR THE CONSTRUCTION AND EQUIPMENT OF SHIPS CARRYING DANGEROUS CHEMICALS IN BULK.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Deck/Cargo
Issued 21 November 1984 Resolved
PROVIDE NEW DRAEGER TUBES FOR BENZENE AND STYRENE MONOMER
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Electrical
Issued 21 November 1984 Resolved
PROVIDE LIGHT GLOBE FOR FIXTURE IN FWD PUMPROOM.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984

Ownership record