WESTERN NIKE I

WESTERN NIKE I is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 42 inspections since 1982, most recently in September 1995, along with 146 deficiencies.

Records from 1982 to 1995. Most recent: inspection, 9 September 1995.

Built
1982
Last inspected
9 September 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
PARAGUAY
—
Maury page id
psix-53880

Inspections, by type

…with no type recorded23
Years with a record 11 calendar years (1982–1995)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2043 - Regulatory (Subpart C or D), Gross Ton
1164 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY5530MMSI not assigned · expired · voluntarily equipped · granted 14 July 1998, cancelled 13 September 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

9 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878203
31 October 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1245534
13 August 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 933040
12 June 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1223359
10 January 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 904193
6 December 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 920357
5 December 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221328
8 August 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212518
22 November 1989 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 902019
6 November 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 924636
7 September 1989 Re-Inspection · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193834
26 June 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889018
2 March 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1199341
14 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041309
25 August 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1194847
3 May 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1344282
30 October 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333056
16 June 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312586
24 April 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315145
25 March 1987 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021660
23 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327835
10 August 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306335
23 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019081
22 October 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299765
4 September 1985 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990305
11 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976848
20 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975138
2 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973654
5 January 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970860
25 October 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973910
11 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277976
11 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272501
11 August 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280794
27 July 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964935
8 June 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971629
13 May 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965723
27 April 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963307
24 November 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277359
28 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967940
29 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965609
4 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279340
13 July 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966615

Deficiency record · 146

Deck/Cargo
Issued 13 August 1991 Resolved
CONDUCT PROPER HYDROSTATIC TEST OF VESSELS OIL TRANSFER HOSE
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Navigation
Issued 13 August 1991 Resolved
REPLACE VESSELS STERN LIGHT WITH APPROPRIATE UNIT.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Navigation
Issued 13 August 1991 Resolved
REPLACE NAVIGATIONAL RUNNING LIGHT BULBS WITH APPROPRIATE TYPE.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Documentation
Issued 13 August 1991 Resolved
SUBMIT CONSTRUCTION PORTFOLIO FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Lifesaving
Issued 13 August 1991 Resolved
MAKE PERMANENT REPAIRS TO FIBERGLASS CRACKS AT THE BASE OF BOTH MIDDLE STANTIONS OF THE #2 LIFEBOAT.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Lifesaving
Issued 13 August 1991 Resolved
MAKE PERMANENT REPAIRS TO THE FIBERGLASS CRACK AT THE BASE OF THE STBD MIDDLE STANTION OF THE #1 LIFEBOAT.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Lifesaving
Issued 13 August 1991 Resolved
REPAIR / RENEW MAGNETIC COMPASS FOR #1 LIFEBOAT.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Electrical
Issued 13 August 1991 Resolved
REPOUR EXPLOSION PROOF ELECTRICAL FITTING FOR GAS DETECTOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Unknown
Issued 12 June 1991 Resolved
SUBMIT REVISIONS TO OPERATING MANUAL PER MSO PORT ARTHUR LETTER OF 01APR91._x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Unknown
Issued 10 January 1991 Resolved
SUBMIT REVISIONS TO OPERATING MANUAL PER MSO PORT ARTHUR LETTER OF 09JAN91.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 6 December 1990 Resolved
SUBMIT REVISIONS TO OPERATING MANUAL PER MSO PORT ARTHUR LETTER OF 09MAY90.
Condition: Unknown
Due 6 December 1990
Resolved 6 December 1990
Unknown
Issued 5 December 1990 Resolved
SUBMIT REVISIONS TO OPERATING MANUAL TO MARINE SAFETY CENTER PER MSO PORT ARTHUR LTR OF 09 MAY 90.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Unknown
Issued 8 August 1990 Resolved
INSTALL INSTRUCTION PLACARD FOR FIXED CO2 SYSTEM LOCAL OPERATION
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPAIR LEAKING WELD AT BULKHEAD PENETRATION ABOVE WTRTGHT DOOR, FWD END OF ENGINEROOM
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
PROPERLY WIRE GENERAL ALARM BELL ON PORT AFT CORNER OF DRILL FLOOR
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
DEMONSTATE PROPER OPERATION OF BILGE PUMPS & BILGE SUCTION SYSTEM
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPAIR AND LABEL GENERAL ALARM BELLS (2) ON MAIN HOUSE BULKHEAD ACROSS FROMDRILL FLOOR
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPAIR AND PERFORM OPERATIONAL TEST OF SINGLE SIDE BAND RADIO
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPLACE FLAME SCREENS IN ALL FUEL OIL VENTS WITH 30"X 30" MESH SCREEN
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPLACE FRACTURED EXPLOSION-PROOF LIGHT FIXTURE BENEATH DRILL FLOOR
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
REPLACE POLYPROPYLENE LINE IN LIFE RING NEXT TO #1 LIFECAPSULE
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Unknown
Issued 8 August 1990 Resolved
PERFORM SATISFACTORY FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF A COASTGUARD MARINE INSPECTOR
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Construction/Loadline
Issued 22 November 1989 Resolved
COMPLETE UNDERWATER IN LIEU OF DRYDOCK EXAMINATION AT NEXT RIG MOVE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Lifesaving
Issued 7 September 1989 Resolved
PROVIDE 12 HAND HELD RED FLARES AND 12 PARACHUTE FLARES FOR #1 LIFE CAPSULES.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Lifesaving
Issued 7 September 1989 Resolved
REPAIR THE INTERNAL LIGHTS ON THE #2 LIFE CAPSULES.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Lifesaving
Issued 7 September 1989 Resolved
PROVIDE THE ORANGE SMOKE, TWELVE RED HAND HELD AND TWELVE RED PARACHUTE FLARES FOR #2 LIFE CAPSULES.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Navigation
Issued 7 September 1989 Resolved
PROVIDE TWELVE HAND HELD PARACHUTE FLARES FOR THE VESSEL.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Electrical
Issued 7 September 1989 Resolved
INSTALL A LOSS OF PURGE AUDIBLE OR VISUAL ALARM ON THE DATA SENTRY TV MONITOR ON THE DRILL FLOOR.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Electrical
Issued 7 September 1989 Resolved
RENEW THE TYPE SD CABLE ON THE PHONE IN THE SCR ROOM WITH APPROVED CABLE.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Navigation
Issued 2 March 1989 Resolved
PROVIDE REMOTE FUEL OIL CUT-OUTS TO THE FUEL OIL DAY TANK.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Lifesaving
Issued 25 August 1988 Resolved
REPAIR SCRAPPED GUNWALES ON #2 CAPSULE ACCORDING TO THE MANUFACTURERS SPECIFICATIONS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Lifesaving
Issued 25 August 1988 Resolved
REPAIR CRACKED GEL COAT ON GUNWALE AND TOP CANOPY OF THE #1 CAPSULE.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Lifesaving
Issued 25 August 1988 Resolved
RENEW CRAACKED REAR WINDOW IN #1 CAPSULE.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Documentation
Issued 25 August 1988 Resolved
PROVIDE CG APPROVED COPIES OF CONSTRUCTION PORFOLIO AND CLASSIFIED HAZARD- OUS LOCATION PLANS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 16 June 1987 Resolved
MAKE SUBSTRUCTURE PLATES ON EACH SPUD CAN AVAILABLE FOR EXAMINATION TO DETERMINE EXTENT OF CRACKING NOTECD DURING SPECIAL UNDERWATER EXAMINATION.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Construction/Loadline
Issued 24 April 1987 Resolved
SUBMIT A PROPOSAL FOR PERMANENT REPAIRS OR REMOVAL OF THE SUBSTRUCTURE PLATES ON ALL SPUD CANS. IF REMOVAL IS PROPOSED, SUBMIT AN ANALYSIS OF THE LOAD BEARING SURFACE OF THE SPUD CANS TO PROVE THAT THEY ARE UNNECESSARY FOR RIG OPEATIONS.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 25 March 1987 Resolved
REPAIR OR REPLACE BROKEN BENT OR MISSING DOGS ON MUD PIT HATCH COVER T-15-0LOCATED ON MAIN DECK, AMIDSHIP
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Lifesaving
Issued 25 March 1987 Resolved
REPLACE MISSIG PUNG ON ESCAPE LADDER LOCATED OR THE STBD STERN AREA.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Construction/Loadline
Issued 25 March 1987 Resolved
REPAIR OR REPLACE BROKEN OR MISSING NUTS ON POLLUTION TANK MANHOLE COVER LOCATED ON MAIN DECK, STERN AREA.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Accommodation/Occupational Safety
Issued 25 March 1987 Resolved
FOLLOWING BULK TANKS TO BE OPENED FOR INTERNAL INSPECTION AND THEIR RELIEF VAVLES TO BE TESTED IN PRESENCE OF A CG INSPECTOR: BULK TANK LOCATED CLOSE TO HOUSE ON PORT SIDE, AND BULK TANK LOCATED FARTHEST FROM HOUSE ON STBD SIDE (BOTH IN BOW AREA).
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Accommodation/Occupational Safety
Issued 25 March 1987 Resolved
DRILL FLOOR AIR RECEIVER TO BE OPENED FOR INTERMAL INSPECTION BY CG INSPECTOR. RELIEF VAVLE TO BE TESTED IN PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Construction/Loadline
Issued 25 March 1987 Resolved
REPAIR SCUPPER DRAIN PIPE LOCATED ON THE PORT BOW AREA. PIPE IS BENT AWAY FROM BARGE HULL BY ABOUT A 45 DEGREE ANGLE.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Unknown
Issued 10 August 1986 Resolved
MAKE ALL PRESSURE VESSELS READY FOR HYDROSTATIC TEST OR INTERNAL INSPECTION.
Condition: Unknown
Due 10 August 1986
Resolved 10 August 1986
Lifesaving
Issued 23 February 1986 Resolved
REPLACE MISSING PUNG ON ESCAPE LADDER LOCATED ON THE STBD STERN AREA.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Accommodation/Occupational Safety
Issued 23 February 1986 Resolved
DRILL FLOOR AIR RECEIVER TO BE OPENED FOR INTERNAL INSPECTION BY CG INSPECTOR. RELIEF VALVE TO BE TESTED IN PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Construction/Loadline
Issued 23 February 1986 Resolved
REPAIR SCUPPER DRAIN PIPE LOCATED ON THE PORT BOW AREA. PIPE IS BENT AWAY FROM BARGE HULL BY ABOUT A 45 DEGREE ANGLE.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Construction/Loadline
Issued 23 February 1986 Resolved
REPAIR OR REPLACE BROKEN, BENT OR MISSING DOGS ON MUD PIT HATCH COVER T-15-0 LOCATED ON MAIN DECK, AMIDSHIP.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Construction/Loadline
Issued 23 February 1986 Resolved
REPAIR OR REPLACE BROKEN OR MISSING NUTS ON POLLUTION TANK MAN-HOLE COVER LOCATED ON MAIN DECK, STERN AREA.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Accommodation/Occupational Safety
Issued 23 February 1986 Resolved
FOLLOWING BULK TANKS TO BE OPENED FOR INTERNAL INSPECTION AND THEIR RELIEF VALVES TO BE TESTED IN PRESENCE OF CG INSPECTOR: BULK TANK LOCATED CLOSESTTO HOUSE ON PORT SIDE, AND BULK TANK LOCATED FARTHEST FROM HOUSE ON STB SIDE. (BOTH IN BOW AREA)
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Electrical
Issued 4 September 1985 Resolved
INSTALL A LEAD LINING INSIDE THE GENERAL ALARM BATTERY BOX.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Fire Fighting
Issued 4 September 1985 Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST OF THE CO2 CYLINDERS TO THE SEMI- PORTABLE DRY CHEMICAL (B-V) EXTINGUISHERS ON THE HELICOPTER DECK.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Construction/Loadline
Issued 4 September 1985 Resolved
MAKE EFFECTIVE REPAIRS TO THE WEATHERTIGHT DOOR ACCESS TO THE TREATMENT ROOM MAIN DECK.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Fire Fighting
Issued 4 September 1985 Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST OF THE AIR CYLINDERS TO THE FIREMAN'SOUTFITS (2) SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Documentation
Issued 4 September 1985 Resolved
PROVIDE ON BOARD THE RIG ONE SET OF FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Electrical
Issued 4 September 1985 Resolved
REINFORCE THE STANCHION SUPPORTING THE FUEL OIL SHUTDOWN VALVE REMOTE OPERATION GEAR.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Electrical
Issued 4 September 1985 Resolved
INSTALL EYS FITTINGS ON THE FOLLOWING ITEMS: (A) ON THE JUNCTION BOX, STARBOARD SIDE FORWARD ON THE DRILL FLOOR; (B) ON THE JUNCTION BOX STAR- BOARD SIDE NEXT TO THE WATERTIGHT DOOR BETWEEN THE MUD PIT & MUD PUMP ROOM;(C) ON THE H2S SENSOR NEXT TO #2 AGITATOR MOTOR IN THE MUD PIT ROOM.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Lifesaving
Issued 4 September 1985 Resolved
PROVIDE FOR EACH LIFEBOAT A SEA ANCHOR.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Unknown
Issued 4 September 1985 Resolved
PROVIDE SUPPORTS FOR THE SALT WATER COOLING PIPING FOR THE THREE AIR COMPRESSORS SERVING THE RIG.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Lifesaving
Issued 4 September 1985 Resolved
PROVIDE EIGHT RED PARACHUTE DISTRESS SIGNALS FOR THE STARBOARD BOAT PRIOR TO MOVEMENT OF THE MODU FROM THIS LOCATION.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Construction/Loadline
Issued 4 September 1985 Resolved
INSTALL DOOR CLOSURE DEVICES ON THE WTD'S BETWEEN THE MUD PIT AND THE MUD PUMP ROOM.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Fire Fighting
Issued 4 September 1985 Resolved
REPAIR THE PACKING GLAND FOR #2 FIRE PUMP AND LABEL THE CONTROLLERS FOR BOTH FIRE PUMPS.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Accommodation/Occupational Safety
Issued 2 July 1984 Resolved
INSTALL A SAFETY GUARD AROUND THE ACCESS TO THE MUT PIT FROM THE DECK.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
PERMANENTLY INSTALL THE ELECTRICAL JUNCTION BOX NEAR THE STARBOARD DOOR TO THE MUD PIT.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
REPLACE THE MISSING VENT SCREEN IN WAY OF THE STARBOARD PUMP ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
SECURE ALL LOOSE CABLES ON THE SANITATION PUMP.
Condition: Unknown
Due 15 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
LABEL GENERAL ALARM LIGHT IN THE MUD PUMP ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
REPAIR THE GENERAL ALARM IN THE SHAKER HOUSE.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Documentation
Issued 2 July 1984 Resolved
PROVIDE AND POST FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
LABEL MOTOR CONTROLLERS ON THE RIG FLOOR, THE SHALE SHAKER ROOM AND THE MUDPIT ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
POUR EYS FITTINGS TO SWACO EQUIPMENT IN SHAKER HOUSE.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
REMOVE DEAD END CABLE ON THE TOP OF THE CONTROL HOUSE OR PROPERLY END.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
INSTALL CONTROL SWITCH FOR PAINT LOCKER VENTILATION FAN NEAR THE CO2 RELEASE.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
INSTALL CLOSING DEVICE ON THE PAINT LOCKER VENT.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
INSTALL GUARD ON PAINT LOCKER VENT.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Accommodation/Occupational Safety
Issued 2 July 1984 Resolved
REMOVE ALL LOCKING DEVICES FROM THE DOORS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
STENCIL THE FIRE DAMPERS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
INSTALL A PLUG IN THE ELECTRICAL JUNCTION BOX ON THE STARBOARD SIDE NEAR THE MAIN GENERATOR.
Condition: Unknown
Due 15 July 1984
Resolved 2 July 1984
Navigation
Issued 2 July 1984 Resolved
REPAIR THE FOG SIGNAL.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
MOVE THE IDENTIFICAITON SIGN OBSTRUCTING THE HELIPORT LIGHTS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
INSTALL A COVER ON EMERGENCY GENERATOR BATTERY BOX, CHOCK STBD BATTERY BOX ON TOP OF CONTROL HOUSE, & PROVIDE APPROVAL LETTERS FOR BARRET BATTERY BOX.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Accommodation/Occupational Safety
Issued 2 July 1984 Resolved
INSTALL QUARTERS VENTILATION SHUTDOWN SWITCH IN THE VICINITY OF THE ALREADYINSTALLED MACHINERY SPACE VENTILATED SHUTDOWNS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
INSTALL FUEL OIL CONTAINMENT UNDER FUEL OIL TRANSFER FITTINGS ON BOTH PORT AND STARBOARD SIDES.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Lifesaving
Issued 2 July 1984 Resolved
PROVIDE EVIDENCE THAT THE INFLATABLE LIFERAFT HAS BEEN SERVICED.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
LABEL CONTROLLERS BY THE STARBOARD LEG.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
PERMANENTLY MOUNT THE ELECTRICAL BOX ON THE PORT SIDE OF THE DRILL FLOOR.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
REPLACE THE MISSING GLASS ON THE CO2 REMOTE CONTROLS FOR THE MAIN GENERATORROOM AND THE MUT PIT ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
PROPERLY STENCIL THE GENERAL ALARM BELLS ON THE PORT AND STARBOARD SIDE OF THE DECK HOUSE BY THE LADDERS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Accommodation/Occupational Safety
Issued 2 July 1984 Resolved
REPAIR THE FREEZER ALARM BUTTON.
Condition: Unknown
Due 15 July 1984
Resolved 2 July 1984
Construction/Loadline
Issued 2 July 1984 Resolved
WELD BOTTOM OF INSERT ON THE DECK TO SCHLUMBERGER UNIT.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Fire Fighting
Issued 2 July 1984 Resolved
LABEL THE GENERAL ALARM BELL IN THE SHAKER ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
INSTALL SAFETY DEVICES AROUND THE LEG COUNTER GEAR.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Construction/Loadline
Issued 2 July 1984 Resolved
REPAIR THE CRACK IN THE WELD ON DECK, PORT SIDE, IN WAY OF THE WATER GUARD.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
LABEL (2) MAIN BREAKERS IN THE GALLEY AS TO USE.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
CONDUCT A DRYDOCK EXAMINATION OR SPECIAL EXAMINATION IN LIEU OF DRYDOCKING IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Accommodation/Occupational Safety
Issued 2 July 1984 Resolved
REPLACE THE COVERS ON THE HEATERS IN THE CHANGE ROOM AND TREATMENT ROOM.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE WESTERN NIKE I, DN 648145.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Documentation
Issued 2 July 1984 Resolved
PROVIDE PROOF OF PERMANENT LOADLINE CERTIFICATE.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Electrical
Issued 2 July 1984 Resolved
STENCIL ALL EMERGENCY LIGHTS THROUGHOUT THE RIG.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 11 August 1983 Resolved
ADJUST THE PORT MUD ROOM SELF-CLOSING DOOR TO FIT TIGHTLY.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Unknown
Issued 11 August 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU WESTERN NIKE I
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Electrical
Issued 11 August 1983 Resolved
STRAP ALL ELECTRICAL CABLES WITH METAL STRAPS WHERE REQUIRED.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Lifesaving
Issued 11 August 1983 Resolved
PROVIDE SIX ADDITIONAL LIGHTS FOR LIFE JACKETS.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Lifesaving
Issued 11 August 1983 Resolved
PROVIDE CARTRIDGES AND PROJECTILES FOR LINE THROWING GUN AND AUXILIARY LINE OF PROPER LENGTH.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Fire Fighting
Issued 11 August 1983 Resolved
PROVIDE TWO (2) OPERATIONAL OXYGEN/COMBUSTIBLE GAS INDICATORS.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Electrical
Issued 11 August 1983 Resolved
REPAIR ALARM FOR WALK-IN FREEZER SPACE.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Deck/Cargo
Issued 11 August 1983 Resolved
PROVIDE HAND SIGNAL CHARTS FOR BOTH CRANES.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Unknown
Issued 11 August 1983 Resolved
PERMANENTLY SUPPORT WITH METAL BRACKETS THE FUEL OIL PIPE ALONG THE EMERGENCY GENERATOR FOUNDATION.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Accommodation/Occupational Safety
Issued 11 August 1983 Resolved
FREE UP AND OPERATE TO THE SATISFACTION OF A USCG MARINE INSPECTOR, ALL FIRE DAMPERS ON THE MAIN DECK.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Unknown
Issued 11 August 1983 Resolved
INSTALL AN APPROVED FIRE DAMPER IN THE MUD ROOM STRABOARD VENT.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Electrical
Issued 11 August 1983 Resolved
PROVIDE EYS FITTINGS FOR BOTH SHALE SHAKER MOTORS.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Navigation
Issued 11 August 1983 Resolved
PROVIDE DAY SHAPES AS REQUIRED BY 1972 COLREGS.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Navigation
Issued 11 August 1983 Resolved
PROVIDE SIDE SCREENS FOR PORT AND STARBOARD RUNNING LIGHTS.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Lifesaving
Issued 11 August 1983 Resolved
PROVIDE UP TO DATE ORANGE SMOKE SIGNALS FOR CAPSULE ON STARBOARD SIDE.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Lifesaving
Issued 11 August 1983 Resolved
PROVIDE UP TO DATE ORANGE SMOKE SIGNALS FOR PORT SIDE CAPSULE.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Lifesaving
Issued 11 August 1983 Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT FOR PORT SIDE CAPSULE.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Construction/Loadline
Issued 11 August 1983 Resolved
POST POLLUTION PREVENTION PLACARDS IN ACCORDANCE WITH 33 CFR 155.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Electrical
Issued 11 August 1983 Resolved
REMOVE SPLICE FROM BUG BLOWER CABLE AFT BULKHEAD OF DRILL FLOOR.
Condition: Unknown
Due 11 August 1983
Resolved 11 August 1983
Electrical
Issued 4 August 1982 Resolved
PROPERLY STRAP CABLES IN WAY OF THE ARTICULATED WIREWAY.
Condition: Unknown
Due 4 August 1982
Resolved 4 August 1982
Electrical
Issued 4 August 1982 Resolved
PROVIDE SUITABLE BLANKS WHERE CIRCUIT BREAKERS ARE MISSING IN VARIOUS CIRCUIT BREAKER PANELS.
Condition: Unknown
Due 4 August 1982
Resolved 4 August 1982
Electrical
Issued 4 August 1982 Resolved
PROPERLY SUPPORT CABLES IN WAY OF THE PORT LEG JACK HOUSE ON THE MAIN DECK.
Condition: Unknown
Due 4 August 1982
Resolved 4 August 1982
Unknown
Issued 4 August 1982 Resolved
PROVIDE ADDITIONAL SUPPORT FOR PIPING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 4 August 1982
Resolved 4 August 1982
Lifesaving
Issued 13 July 1982 Resolved
PROVIDE A LITTER CAPABLE OF USE ON THE HELO WHICH SERVICES THE VESSEL.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
REPLACE ALL MISSING PANELS IN MOTOR CONTROLLER BOARDS IN THE SCR ROOM AND EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
PROPERLY SUPPORT AND TIE ALL WIRING IN THE OVERHEAD OF THE CONTROL ROOM.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE CCGD8 MMT INFORMATION FOR APPROVAL OF "ADAPTABELL" GENERAL ALARMS.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE CCGD8 MMT MANUFACTURERS DATA SHEETS FOR AIR RECEIVERS BUILT IN SOUTH AFRICA (4).
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE THE ABS RADIOGRAPHIC EXAMINATION REPORTS FOR ALL HIGH PRESSURE PIPING.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE SIGNS AND MARKINGS THROUGHOUT THE VESSEL AS REQUIRED.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
CHANGE THE MUD PUMP ROOM EXHAUST FAN BREAKER FROM 50 AMP TO 20 AMP.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
CHANGE THE FUEL OIL PURIFIER #1 AND #2 BREAKERS FROM 20 AMP TO 15 AMP.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
CHANGE THE MUD ADGITATOR #7 SMALL BREAKER FROM 20 AMP TO 15 AMP.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
CHANGE THE TRI-FLO MUD 3 HP PUMP BREAKER FROM 20 AMP TO 15 AMP.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
INSURE CIRCUITS FOR HOT WATER HEATERS #1,#2, AND #3 ARE ALL PROTECTED WITH 50 AMP BREAKERS EACH.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
INSURE CIRCUITS FOR HOT WATER HEATERS #1,#2, AND #3 ARE ALL PROTECTED WITH 50 AMP BREAKERS EACH.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
REPLACE CIRCUIT BREAKERS IN QUARTERS HEATING AND AIR CONDITIONING PANEL TO REFLECT SIZES ON DRAWING WO4-E-021 REV. F.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
REPLACE CIRCUIT BREAKERS IN MAIN LIGHTING DISTRIBUTION SWITCHBOARD PANEL TOREFLECT THE SIZES ON DRAWING WO4-E-015 REV. H.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
REPLACE THE MITSUBICHI BREAKERS FOR THE TWO GALLEY MAIN SUPPLY D.B. WITH APPROVED TYPE.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
REPLACE THE CIRCUIT BREAKERS IN THE MAIN LIGHTING DISTRIBUTION SWITCHBOARD "B" PANEL TO REFLECT SIZES ON DRAWING WO4-E-016 REV. H.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
SUBMIT DATA ON NON-METALIC FLEXIBLE HOSES USED IN FIREMAINS.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE CCGD8 MMT WITH THE FOLLOWING DRAWINGS FOR APPROVAL:A)CIRCUITS USINGOTHER THAN "BRAND REX" CABLE, B)HAZARDOUS LOCATIONS, AND C)GENERAL ALARM.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
D)MAIN SWITCHBOARD, E)EMERGENCY SWITCHBOARD, F)FIREMAIN CALCULATIONS, G) ARRANGEMENT SHOWING STAIRWAYS, STAIR TOWERS, JOINER, AND JOINER DETAILS.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
WO4-P2, WO4-P64, WO4-P65, WO4-P51, WO4-P4, WO4-P69, WO4-P69A, WO4-P1, AND AIR COMPRESSOR PACKAGE.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE MOTOR CONTROLLER DIAGRAMS IN SCR ROOM.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROVIDE SWITCHBOARD DIAGRAM IN SCR ROOM.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Electrical
Issued 13 July 1982 Resolved
PROPERLY TIE ALL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982
Unknown
Issued 13 July 1982 Resolved
PROPERLY SUPPORT ALL PIPING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 13 July 1982
Resolved 13 July 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.