Records from 1985 to 2008. Most recent: inspection, 16 April 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
16 April 2008
DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185794
2 June 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 818967
20 March 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1047722
15 April 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791229
24 March 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115878
17 March 1998
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786914
21 March 1997
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1102747
20 March 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1411262
18 April 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 854110
21 March 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392197
10 August 1994
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1174235
15 March 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461562
15 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385037
25 June 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958047
31 March 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961626
30 April 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 899432
30 April 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 900911
18 May 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1218432
14 March 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1208080
28 April 1988
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 887549
9 March 1988
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1027361
12 May 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1311689
11 April 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 998670
18 April 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 982898
Engineering
Issued 24 March 1999
Resolved
Repair fuel tank mount bracket cracked fillet weld port side.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Engineering
Issued 24 March 1999
Resolved
Ensure replacment of starboard engine starboard side engine mount bolt.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Engineering
Issued 21 March 1997
Resolved
RENEW FUEL FILL DECK FITTING.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 21 March 1997
Resolved
RENEW PALCARD FOR EMERGENCY FUEL SHUT-OFF, STBD SIDE.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 21 March 1997
Resolved
DRILL STOP AND V-WELD CRACK IN SIDE SHELL STBD SIDE IN WAY OF ENGINE COMPARTMENT BULKHEAD.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP & RENEW STBD AFT CORNER IWO GUNWALE.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 21 March 1997
Resolved
INSTALL DRAIN PANS FITTED WITH 30 X 30 MESH FLAME SCREENS UNDER EACH SET OFFUEL FILTERS.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 21 March 1997
Resolved
REWELD FIRST TRANSVERSE WEB, FWD OF ENGINE COMP. BULKHEAD, IN WAY OF OUTBOARD LONGS, P & S SIDES.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 21 March 1997
Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 21 March 1997
Resolved
REPLACE ENGINE COMPARTMENT VENT FITTING, FWD PORT SIDE.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Accommodation/Occupational Safety
Issued 21 March 1997
Resolved
REWELD STEPS ON BOW EMBARCATION LADDER.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 21 March 1997
Resolved
V-WELD 2 INCH AREA OF BOTTOM PLATE IN WAY OF TRANSOM, PORT SIDE AS MARKED.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 21 March 1995
Resolved
PROVIDE PROOF OF CURRENT ENROLLMENT IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 31 March 1992
Resolved
PROVIDE INTAKE AND EXHAUST DUCTING FOR ENGINE COMPARTMENT THAT IS FIRE PROOF.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 31 March 1992
Resolved
PROVIDE BLOWER INTERLOCK SO THAT THE ENGINES DON'T START UNLESS BLOWERS ARERUNNING.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 31 March 1992
Resolved
PROVIDE FUEL SHUTOFF VALVES AT THE FUEL TANK AND MAKE THEM OPERABLE FROM OUTSIDE THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Fire Fighting
Issued 12 May 1987
Resolved
THE VENTS FOR THE ENGINE COMPARTMENT MUST HAVE MEANS OF CLOSURE (PLUGS, COVERS, ETC.) TO PREVENT THE ADMISSION OF AIR INTO THE SPACE IN THE EVENT THE FIXED FIREFIGHTING SYSTEM IS ACTIVATED (IN ACCORDANCE WITH 46 CFR 181.20-35).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Documentation
Issued 12 May 1987
Resolved
PROVIDE EMERGENCY CHECK-OFF LIST FOR VESSEL.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
STENCIL VESSEL'S NAME ON ALL LIFE PRESERVERS.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 12 May 1987
Resolved
PROVIDE INTERLOCK SWITCH IN IGNITION SYSTEM FOR THE ENGINES SO BLOWERS WILL BE ACTIVATED BEFORE THE ENGINES WILL START (ALREADY AN OUTSTANDING REQUIREMENT).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987
Resolved
RENEW MASTHEAD LIGHT FOR VESSEL.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
PRIOR TO CARRYING PASSENGERS FORE HIRE, RENEW LINE AROUND RING BUOY.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
PROVIDE MOUNTING BRACKET FOR THE SECOND B-I PORTABLE EXTINGUISHER.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987
Resolved
MAKE NECESSARY REPAIRS TO LEAKING BILGE LINES IN THE ENGINE COMPARTMENT.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Construction/Loadline
Issued 12 May 1987
Resolved
EFFECT REPAIRS TO THE FRACTURED LONGITUDINALS ON EACH SIDE OF THE ENGINE COMPARTMENT (ON THE SIDESHELL).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 11 April 1986
Resolved
PROVIDE ADDITIONAL B-I PORTABLE FIRE EXTINGUISHER SO AS TO BRING THE TOTAL NUMBER OF FIRE EXTINGUISHERS REQUIRED TO TWO B-IS AS PER 46 CFR TABLE 181.30-1(A) PRIOR TO 14 MAY 86.
Condition: Unknown
Due 11 April 1986
Resolved 11 April 1986
Electrical
Issued 11 April 1986
Resolved
PROVIDE AN EXHAUST BLOWER SWITCH SUCH THAT THE STARTER SWITCH CANNOT BE ACTIVATED WITHOUT THE BLOWERS BEING STARTED AS PER 46 CFR 182.15-45(D) PRIOR TO 14 MAY 86.
Condition: Unknown
Due 11 April 1986
Resolved 11 April 1986
Unknown
Issued 11 April 1986
Resolved
PROVIDE PROOF OF VESSEL'S USCG DOCUMENTATION AS REQUIRED BY 46 CFR 67.01-5 PRIOR TO 14 MAY 86.
Condition: Unknown
Due 11 April 1986
Resolved 11 April 1986
Lifesaving
Issued 18 April 1985
Resolved
ATTACH RETROREFLECTIVE MATERIAL TO EACH LIFE PRESERVER TO COMPLY WITH 46 CFR 180.25-25.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985