MAURY USCG vessel records Sign in
← All vessels

TYSON B

TYSON B is a 1964 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1982, most recently in December 2025, along with 77 deficiencies.

Records from 1982 to 2025. Most recent: inspection, 23 December 2025.

Built
1964
Last inspected
23 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7100859 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WAP9747
Flag
UNITED STATES
367079040
Maury page id
psix-53893

Inspections, by type

…with no type recorded8
Years with a record 36 calendar years (1982–2025)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.0 ft × 33.0 ft × 10.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN MARINE · NEW ORLEANS LA · built 1964
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR4128MMSI 367079040 · active · compulsorily equipped · granted 3 September 2026, expires 3 September 2036
WAP9747MMSI 367079040 · expired · compulsorily equipped · granted 9 October 2015, cancelled 7 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 81

23 December 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection · Vessel Attendance
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8286771
4 September 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8202077
13 August 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7980171
27 October 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7822736
11 October 2023 Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7808114
4 October 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7803759
7 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7739562
3 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631804
1 February 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7632855
19 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7510769
17 May 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7453140
14 March 2022 Deficiency Check · Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411492
3 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7378066
13 August 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7285645
20 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011313
6 January 2020 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6883762
18 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814769
5 September 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6804449
2 August 2018 DAPI Audit · Annual Inspection · Deficiency Check · In-Service Inspection · Administrative Inspection · Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6488958
19 December 2017 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6326829
31 May 2017 DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6157207
17 April 2017 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6126572
8 April 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5888258
25 March 2016 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5962472
14 December 2015 Annual Inspection · Hull Examination · Administrative Inspection · Deficiency Check · Inclining Experiment · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5781535
18 November 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5766269
13 October 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3865016
30 March 2010 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3698688
25 February 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3665890
27 January 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3400739
29 December 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3385786
23 January 2008 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3134979
7 December 2007 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3111396
27 March 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2896207
12 March 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883612
7 March 2007 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883261
9 January 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2853111
12 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2623267
4 January 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2560530
23 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2499633
15 March 2005 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2310572
1 March 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2301184
12 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2009787
10 January 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1734381
23 December 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1719459
24 September 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1674890
28 March 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491936
3 April 2001 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 1521178
25 January 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825437
27 December 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467177
1 April 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1119152
10 November 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429039
6 March 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1124477
6 February 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 166261
2 February 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392860
19 March 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097694
18 February 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1435876
2 February 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445049
5 October 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404025
24 February 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392255
15 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857819
4 February 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163105
12 November 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849330
25 February 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837726
14 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260483
20 July 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259649
10 April 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1266191
10 February 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943769
23 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928725
26 November 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227829
4 October 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897947
4 October 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899322
10 August 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1226632
8 May 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1350110
3 August 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340793
9 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012325
18 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312999
27 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307073
12 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291640
17 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975696
28 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272455

Deficiency record · 77

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2025 Resolved
All piping, valves and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI observed piping at the base of the port fire station had a significant leak. Repair fire main pipes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2025
Resolution: Attended vessel, pipe replaced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 September 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level. Alarm was not visible or audible from the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2025
Resolution: Attended vessel, visual and audible function.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2025 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Owner reported inop generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2025
Resolution: Attended vessel, witnessed machinery successfully running under load.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 September 2025 Resolved
All GMDSS equipment capable of transmitting an automatic distress alert which includes position of the ship must have either an integral navigation receiver or capability of being connected to an external navigation receiver. If an external navigation receiver is installed, it shall be connected to all of the alerting devices referred to in paragraph (a) of this section. Position was not being communicated between GPS and VHF radio. Ensure radio receives position coordinates. Vessel restricted to 1,000 feet from shore.
Action required: 705 - Other - as specified
Resolved 12 September 2025
Resolution: Attended vessel, witnessed radio transmitting gps location.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2022 Resolved
Flammable liquids not kept in locker constructed of steel, wholly lined steel or equivalent. 46 CFR 177.405(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 8 June 2022
Resolution: Corrected when MI present
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 June 2022 Resolved
Pendent line from float light wasted on both life floats. 46 CFR 180.175 (f)(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2022
Resolved 8 June 2022
Resolution: Deficiency cleared. Replaced when MI present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2021 Resolved
Machinery and its equipment must be suitable for the vessel and its operation and for the purpose intended. Vessels gauge panel for the STBD generator was found to be unsecured. Properly secure gauge panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 20 August 2021
Resolution: Vessel secured gauge panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2021 Resolved
All electrical equipment and circuits must be clearly marked. Vessel had several elec. panels that the circuits inside were not clearly identified with there service and amp. Vessel must clearly identify all breakers along with amperage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 20 August 2021
Resolution: Vessel properly and clearly labeled all elect. switchboards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2021 Resolved
All electrical systems must be to the satisfaction of the OCMI. Vessel had an electrical box for the vessels port side spot light located on the flying bridge that was dangling and unsecured. Secure electrical box for spot light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 20 August 2021
Resolution: Vessel properly secured electric box for port spot light.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 January 2020 Resolved
Repair leak in firemain piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 January 2020 Resolved
Repair all side shell found to be greated than 25% wastage as per guaging report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 February 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 August 2018 Resolved
Welding completed on "A" frame structure in lazarette found to have defects. Wrap structural welds and grind and re-weld areas marked by attending Inspectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2018
Resolved 21 August 2018
Resolution: Welding was found satisfactory to the Coast Guard.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 2 August 2018 Resolved
A new A-frame lifting device was installed on the aft deck of the vessel without the approval of the [name withheld] plans, calculations and approvals to the satisfaction of the OCMI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 August 2018 Resolved
Vessel could not provide navigation charts and notice to mariners. Provide up to date/corrected charts and NTM's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2018
Resolved 10 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 August 2018 Resolved
Master could not provide evidence supervisory trainign for DAPI program, hot line number not posted, no evidence of up to date consortium enrollment, insufficient knowledge of testing requirements and no alcohol test devices onboard. Provide evidence and knowledge of drug and alcohol program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2018
Resolved 10 August 2018
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 2 August 2018 Resolved
Vessel is allowed to operate under its current Stability Letter, dated March 23, 2016, and only operate within 20 nautical miles from a harbor of safe refuge. However, use of the installed "A" frame is prohibited and must be secured to the deck and counted as cargo weight, per the stability letter. The controls for the "A" frame must also be tagged out. This operational restriction will stay in place until a new stability letter has been issued, but no later than September 12, 2018, and the welding repairs have been inspected, and accepted by a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2018
Resolved 21 August 2018
Resolution: A new Stability Letter dated August 21, 2018 was issued.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 31 May 2017 Resolved
Main deck Port Fuel vent screen, Replace/renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Cleared
Engineering › Steering Gear System › Ram
Issued 31 May 2017 Resolved
Repair leaking steering ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Cleared
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 April 2017 Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 07Feb17
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 31 May 2017
Resolution: Completed
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 17 April 2017 Resolved
Make pressure vessels available for inspection. Pressure vessel inspection is overdue as of 27Mar17.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 31 May 2017
Resolution: Witnessed
Stability › Incline Test › General
Issued 9 March 2016 Resolved
Limited loading for vessel till MSC and vessel owner revise stability letter from incline test recently performed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 28 March 2016
Resolution: received letter from MSC with new stability info.
Electrical › Electric Generation Source (service) › Generator
Issued 26 January 2016 Resolved
A 60KW Generator was installed without plan approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 16 February 2016
Resolution: Plan approval for newly installed gen set approved by MSC 16Feb16. Serial E2-1600500.
Stability › Intact Stability (when using lifting gear) › General
Issued 26 January 2016 Resolved
Newly installed crane will need a third party inspection of proper operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 3 March 2016
Resolution: Witnessed operational test of newly installed crane on port side of main deck, test satisfactory.
Lifesaving › Lifebuoys › Serviceable
Issued 25 February 2010 Resolved
Provide and install new retro-reflective material for all ring life buoys as required by 46 CFR 180.30-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Retro reflective tape for all ring life buoys was found satisfactory.
Lifesaving › Lifefloat › Float Free
Issued 25 February 2010 Resolved
Properly stow the life floats so the life floats will float free in an emergency as required by 46 CFR 180.20-1.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Life floats were relocated and upon inspection were found to be capable of float free operation as required.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 February 2010 Resolved
Provide and install new gaskets in all watertight hatches, door, and closures and prove watertightness of closures as required by 46 CFR 178.35-1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Upon inspection all gaskets were found to be in satisfactory condition.
Engineering › Bilge Water Management System › Strainer
Issued 25 February 2010 Resolved
Provide and install a bilge strainer on the bilge suction pipe in the steering compartment as required by 46 CFR 182.25-5.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: A new strainer was installed and upon inspection was found to be in satisfactory condition.
Engineering › Bilge Water Management System › Valve
Issued 25 February 2010 Resolved
Prove proper operation of the bilge overboard valve in the steering compartment on the starboard side. as required by 46 CFR 178.40-1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Bilge overboard valve was properly installed and found to be in working order.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 February 2010 Resolved
Properly support the electric cable leading to the control panel for the fire pump as required by 46 CFR 183.10-20.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Electrical cable was rerouted and properly supported as required and found to be in satisfactory condition.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 February 2010 Resolved
Protect both generator batteries against shifting with the roll and the pitch of the vessel as required by 46 CFR 183.05-30.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Generators were located in approved battery box and installed in a way to prevent shifting.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 February 2010 Resolved
Update all nautical publications and charts to the latest notice to mariners as required by 46 CFR 185.20-35.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: All nautical publications and charts were found to be up to date.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 25 February 2010 Resolved
Reroute flexible non-metallic hose for fuel oil supply line from shut-off valve to starboard main engine and provide factory-type fitting for flexible non-metallic hose connections as required by 46 CFR 182.40-1.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 April 2010
Resolution: Fuel oil supply line was rerouted and supported as required.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 25 February 2010 Resolved
Provide on board vessel fuel oil transfer procedures as required by 33 CFR 155.720,
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Fuel oil transfer procedures were on board as required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 February 2010 Resolved
Provide proper portable fire extinguisher brackets for engine room extinguishers to prevent shifting with the roll and the pitch of the vessel as required bt 46 CFR 181.30-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Fire extinguishers were properly mounted to prevent shifting as required.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 February 2010 Resolved
Check all protective guards on engine room and ensure they are properly supported for all rotating machinery as required by 46 CFR 177.35-15.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 March 2010
Resolution: Upon inspection of machinery posing a personnel hazard all were found have sufficient guards as required.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 January 2009 Resolved
Prove proper operation of fuel shutoff remote valve operation as per 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 10 March 2009
Resolution: The remote reach rods were both renewed, replaced and demonstrated.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 27 January 2009 Resolved
Repair excessive leaking of oil from port main engine as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 10 March 2009
Resolution: The owner hired a mechanic to install new gaskets through the engine.
Lifesaving › Lifefloat › Float-free Link
Issued 19 December 2007 Resolved
Prove the capacity of the weak link for the life floats as per 46 CFR 180.175.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Bought new, sufficient capacity, weak link.
Lifesaving › Lifefloat › Painter
Issued 19 December 2007 Resolved
Properly attach the painter line to the weak link on the life floats as per 46 CFR 180.175.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Properly attached the painter line to the weak link.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 December 2007 Resolved
Provide and install a retainer clip on the water light for the top life float and prove proper operations as per 46 CFR 180.175.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Retainer clip properly installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 December 2007 Resolved
Replace the broken/cracked retainer bracket for the water light on the top life float as per 46 CFR 180.175.
Due 19 January 2008
Resolved 8 January 2008
Resolution: New water light and retainer bracket were properly installed.
Communications › Radio Communications › EPIRB
Issued 19 December 2007 Resolved
Properly mount the EPIRB and prove it is registered as per 46 CFR 180.64. My not exceed 3 miles form shore until cleared by a Coast Guard Marine Inspector.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Properly mounted and registered their EPIRB.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 December 2007 Resolved
Properly label the life jacket stowage with the proper umber of life jackets as per 46 CFR 185.604.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Stowage properly marked with the number included.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 19 December 2007 Resolved
Provide valve handles for all sea chest valves as per 46 CFR 182.420.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Valve handles were properly installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 December 2007 Resolved
Remove all oil and rags form the bilges of the engine room and make ready for inspection as per 46 CFR 176.800.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Removed the oil and oily rags from the bilges.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 December 2007 Resolved
Prove proper operation of the port main engine shut down form the pilot house.
Due 19 January 2008
Resolved 8 January 2008
Resolution: Shut down operated properly.
Stability › Watertight Integrity › General
Issued 12 March 2007 Resolved
Properly secure and make watertight all three hatches on the forecastle in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 27 March 2007
Resolution: Three hatches secured properly with metal line.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 March 2007 Resolved
Crop and renew the marked areas on the deck longs in the #4 port and starboard potable water tanks near the forward bulkhead of each tank in accordance with NVIC 7-68.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 27 March 2007
Resolution: Marked areas cropped and renewed as required.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 January 2006 Resolved
USCG light list expired needs renewed or replaced as per 72 COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 10 January 2007
Resolution: Provided current USCG light list as per 72 COLREGS.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 January 2006 Resolved
Red lights indicating the vessel is restricted in maneuverability are not operating and need repaired or replaced as per 72 COLREGS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2006
Resolution: Light bulbs were replaced.
Stability › Watertight Integrity › General
Issued 9 January 2006 Resolved
Remove the garden hose being used as a gasket and replace with a gasket as per 46 CFR 171.124.
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 10 January 2007
Resolution: Removed the garden hose being used as a gasket and replaced it with a proper gasket as per 46 CFR 171.124.
Stability › Watertight Integrity › General
Issued 9 January 2006 Resolved
Remove silicon caulking around the base of the starboard fuel vent and weld from both sides as per NVIC 7-68.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 10 January 2007
Resolution: Removed the silicon caulking around the base of the starboard fuel vent and welded it on both sides as per NVIC 7-68.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 January 2006 Resolved
Renew/repair the electrical connection on the halyard made with extension cord plugs as per 46 CFR 183.340.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2007
Resolution: Repaired the electrical connection on the halyard as per 46 CFR 183.340.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 March 2005 Resolved
Provide visual indicator for high-level alarms IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 26 April 2005
Resolution: Visual indicator was provided and operational.
Documentation › Logs/Records › Logbook (official)
Issued 23 March 2005 Resolved
Update bridge log IAW 46 CFR 185.420
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 26 April 2005
Resolution: Bridge log was updated.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 March 2005 Resolved
Update equipment maintenance record IAW 46 CFR 185.702
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 26 April 2005
Resolution: Log was updated.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 23 March 2005 Resolved
Update training manual IAW 46 CFR 185.420
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 26 April 2005
Resolution: Manual was updated.
Engineering › Steering Gear System › Rudder Stock
Issued 3 March 2005 Resolved
Renew angle iron brackets supporting both the port and starboard rudders as original.
Action required: 705 - Other - as specified
Due 3 March 2005
Resolved 26 April 2005
Resolution: Angle irons were replaced in kind.
Construction/Loadline › Structures › Deck Plating
Issued 3 March 2005 Resolved
Crop and renew deteriorated deck stiffeners in the starboard water tank compartment as original.
Action required: 705 - Other - as specified
Due 3 April 2005
Resolved 26 April 2005
Resolution: Stiffener was replaced in kind.
Construction/Loadline › Hull › Bottom Plating
Issued 21 January 2003 Resolved
Replace wasted bottom plating under keel coolers.
Due 31 January 2003
Resolved 21 January 2003
Lifesaving
Issued 2 February 1998 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED FIRST AID KIT OR ALL ITEMS REQUIREDBY 46 CFR 160.041 AS PER 46 CFR 184.710.
Condition: Unknown
Due 2 March 1998
Resolved 23 March 1998
Electrical
Issued 2 February 1998 Resolved
RENEW BATTERY TERMINALS ON THE BATTERY LOCATED ON PORT SIDE OF PILOT HOUSE SEE 46 CFR 183.350.
Condition: Unknown
Due 2 March 1998
Resolved 23 March 1998
Lifesaving
Issued 2 February 1998 Resolved
MAKE LIFE RING ACCESSIBLE ON AFT DECK IN ACCORDANCE WITH 46 CFR 180.70(B).
Condition: Unknown
Due 2 March 1998
Resolved 23 March 1998
Engineering
Issued 18 February 1997 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY FUEL OIL SHUT OFF VALVE._x001C_ 46 CFR 176.804(f) AND 46 CFR 185.608.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 18 February 1997 Resolved
RENEW ALL DETERIORATED RAILING LOCATED ON THE FLYING BRIDGE._x001C_ 46 CFR177.900
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 18 February 1997 Resolved
RENEW ALL DETERIORATED RAILING LOCATED ON THE BRIDGE DECK._x001C_ 46 CFR 177.900
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Electrical
Issued 18 February 1997 Resolved
PROVIDE DOCUMENTATION THAT GENERATORS RATED AT 40 deg C AMBIENT AIR TEMPERATURE HAVE BEEN DERATED TO 80% OF THE FULL LOAD RATING. PROVIDE NAMEPLATE DATA._x001C_ 46 CFR 183.320 (b)(e)
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Electrical
Issued 18 February 1997 Resolved
REMOVE ALL WIRENUTS IAW 46 CFR 183.340
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Electrical
Issued 18 February 1997 Resolved
INSTALL METAL WIRE SUPPORTS EVERY 24" OF EACH WIRE RUN._x001C_ 46 CFR 183.340
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Navigation
Issued 10 February 1992 Resolved
PROVIDE AND INSTALL SSB RADIO FOR OCEANS ROUTE. UNTIL SSB IS INSTALLED VESSEL IS LIMITED TO COASTWISE NOT MORE THAN 20 MILES FROM A HARBOR OF SAFEREFUGE. _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Lifesaving
Issued 10 February 1992 Resolved
PROVIDE FUEL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Electrical
Issued 10 February 1992 Resolved
RENEW OUTLET BRACKET ON TOP OF PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Engineering
Issued 10 February 1992 Resolved
REMOVE NON APPROVED FUEL STRAINER AND RENEW WITH APPROVED FUEL STRAINERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Navigation
Issued 10 February 1992 Resolved
INSTALL RUDDER STOPS P/S SIDES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Accommodation/Occupational Safety
Issued 10 February 1992 Resolved
REMOVE AND REPLACE RELIEF VALVE ON PORT AIR RECEIVER IN ENGINE ROOM WITH RELIEF VALVE OF PROPER SETTING.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Unknown
Issued 23 December 1990 Resolved
REPAIR RAILING OF FLYING BRIDGE.
Condition: Unknown
Due 23 December 1990
Resolved 23 December 1990
Accommodation/Occupational Safety
Issued 26 November 1990 Resolved
REPAIR RAILING FOWARD SECTION OF FLYING BRIDGE.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.