MAURY USCG vessel records
← All vessels

MARGARET S

MARGARET S is a 1973 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in April 2026, along with 16 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 28 April 2026.

Built
1973
Last inspected
28 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WSN8923
Flag
UNITED STATES
Maury page id
psix-53894

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

28 April 2026 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8356301
14 April 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8120793
24 April 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7905996
27 April 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7679265
18 April 2023 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7671077
18 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7432948
18 May 2021 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7201635
16 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7176616
27 April 2020 COI Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6944509
10 June 2019 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6722430
19 April 2019 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6671460
7 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6437140
20 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6243241
24 April 2017 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6131566
6 June 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5916221

Deficiency record · 16

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 April 2026 Resolved
The vessel's O/O was not able to provide training and drill logs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 21 May 2026
Resolution: Received email from O/O and cleared open deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2023 Resolved
Vessel could not provide proper testing of Fireboy shut down and restart.
Due 11 May 2023
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2023 Resolved
Properly label storage for child life jackets.
Due 11 May 2023
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2023 Resolved
Repair/replace life buoy as necessary.
Due 11 May 2023
Resolved 28 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2023 Resolved
Replace flame screen on fuel vent.
Due 11 May 2023
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2022 Resolved
Ring Buoy needs a line attached.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Line attached to buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 April 2022 Resolved
Flares are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Flares provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2022 Resolved
Fire buckets need lines attached.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Lines atached to buckets.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 April 2022 Resolved
Vessel needs emergency broadcast placard.
Action required: 66 - Prior to drilling or production operations
Due 18 April 2022
Resolved 6 May 2022
Resolution: Placard provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2020 Resolved
ER vents need plugs/covers.
Due 13 May 2020
Resolved 25 June 2020
Resolution: Covers made for dorade.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2020 Resolved
Vessel needs 03 fire buckets, labelled with lanyards.
Due 13 May 2020
Resolved 25 June 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2020 Resolved
Electric bilge pump needs a visual indicator at operating station.
Due 13 May 2020
Resolved 25 June 2020
Resolution: Visual indicator installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2016 Resolved
Remove or repair VHF-FM.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2016 Resolved
Label lifejacket storage.
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 8 September 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 June 2016 Resolved
Provide COI, stability letter, state registration and operator license on board the vessel.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 6 June 2016 Resolved
Service fireboy system.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016

Ownership record