← All vessels
CONQUESTVENTURE
CONQUESTVENTURE is a 1980 tank ship. The Coast Guard has recorded 44 inspections since 1987, most recently in December 1999, along with 30 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 1987 to 1999. Most recent: inspection, 1 December 1999.
- Built
- 1980
- Last inspected
- 1 December 1999
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7904073 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELVL6
53897
Flag
GREECE
—
Maury page id
psix-53897
Inspections, by type
…with no type recorded26
…past their stated due date1
Years with a record
12 calendar years (1987–1999)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it18812 - Regulatory (Subpart C or D), Gross Ton
18758 - Convention (Subpart B), Gross Ton
12678 - Regulatory (Subpart C or D), Net Ton
12678 - Convention (Subpart B), Net Ton
31766 - Dead Weight, Ton
18758 - Convention (Subpart B), Gross Ton
12678 - Regulatory (Subpart C or D), Net Ton
12678 - Convention (Subpart B), Net Ton
31766 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 44
1 December 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 812464
14 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 431673
14 August 1999
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 777815
23 January 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1116208
19 January 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 411988
8 July 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 392923
8 February 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 387591
8 February 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 875055
26 May 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 378721
26 May 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1184101
22 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378601
22 May 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 870683
22 May 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1182011
5 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 191897
5 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378106
5 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 752678
5 May 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212868
16 November 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1449740
18 April 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 857465
5 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366076
4 April 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 365727
20 November 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 837495
8 November 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 647289
4 November 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 101872
4 November 1993
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141387
9 July 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 359351
25 November 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 354598
13 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 354241
13 November 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1447198
7 August 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 345173
7 August 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248638
26 November 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 493970
10 April 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 457815
21 July 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331442
21 July 1989
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896826
23 December 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327758
25 March 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 322211
25 March 1988
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989253
25 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 516079
21 November 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 484924
10 July 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1016606
30 June 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1010344
6 February 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 314023
6 February 1987
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1011968
Deficiency record · 30
Deck/Cargo
Issued 14 August 1999
No resolution recorded
COMBING FORWARD OF MANIFOLD STATIONS (PORT AND STBD) WAS MEASURED AND FOUNDTO BE 3.5 INCHES. REQUIRED COMBING TO BE INCREASED TO 4 INCHES IAW 33 CFR 155.310 (c).
Lifesaving
Issued 19 January 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 19 January 1998
Resolved
EMERGENCY FIRE PUMP COULD NOT OBTAIN ADEQUATE FIRE FIGHTING PRESSURE. SOLAS 74 (AMMENDED) REG II-2/5.
Lifesaving
Issued 19 January 1998
Resolved
LIFE BOAST UNABLE TO BE HOISTED BY NORMAL SHIPS EQUIPMENT. SOLAS 74 (AMMENDED REG III-48/1.10
Engineering
Issued 19 January 1998
Resolved
VESSEL TO MAKE TEMPORARY REPAIR TO GENERATOR SALTWATER COOLING LINE LEAK PORT SIDE ENGINE ROOM. PERMANENT REPAIRS TO BE COMPLETED PRIOR TO NEXT U.S. ENTRY.
Deck/Cargo
Issued 19 January 1998
Resolved
VESSEL TO REPLACE WORN WASTED COUPLING JOINTS ON HYDRAULIC LINE TO CARGO OIL PUMPS. SOLAS 74 REG II-2/56
Lifesaving
Issued 8 February 1996
Resolved
SERVICE SCBA'S AS REQUIRED BY BCH 3.16.8 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Deck/Cargo
Issued 8 February 1996
Resolved
PROVIDE SPAN GAS FOR CALIBRATION OF COMBUSTION GAS INDICATOR AS REQUIRED BYBCH 3.13 TO SATISFACTION OF LOCAL U.S COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Deck/Cargo
Issued 8 February 1996
Resolved
REPAIR/ RENEW HIGH LEVEL VISUAL ALARM ON OPEN DECK SO IT WILL BE VISABLE ASREQUIRED BY 46 CFR 153.409 AND 46 CFR 153.408 TO SATISFACTION OF LOCAL U.S.COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Navigation
Issued 26 May 1995
Resolved
COAST PILOT VOLUME 5 1994 PUBLICATION, NAS NO CORRECTIONS. NEEDS TO BE CORRECTED UP TO 12/95 FROM THE NOTICE TO MARINERS #21.
Deck/Cargo
Issued 26 May 1995
Resolved
Ensure Shipboard Oil Pollution Emergency Plan copy onboard is properly endorsed by flag state or authorized representative prior to cargo handlingin next U.S. port
Fire Fighting
Issued 5 May 1995
Resolved
FIREMAIN LINE BROKE AT COUPLING ON MAIN DECK DURING TEST.
Fire Fighting
Issued 5 May 1995
Resolved
EMERGENCY FIRE PUMP INOPERABLE.
Deck/Cargo
Issued 5 May 1995
Resolved
SPARE CARGO HOSES ON DECK WERE NOT BLANKED OFF RESULTING IN A POLLUTION VIOLATION.
Engineering
Issued 16 November 1994
Resolved
THE PIPING TO THE ATMOSPHERIC CONDENSER LOCATED IN THE ENGINE ROOM STARBOARD SIDE IS LEAKING. IT HAS BEEN REPAIRED SEVERAL TIMES IN THE PAST. PERMANENT REPAIRS MUST BE MADE TO THE SATISFACTION OF THE ATTENDING CLASS REP BY MAY 95. TEMPORARY REPAIRS WERE INSPECTED AND APPROVE BY CLASS.
Deck/Cargo
Issued 16 November 1994
Resolved
BOTH PORT AND STARBOARD ACCOMMODATION BUNKER MANIFOLDS HAVE FIBERGLASS PATCHES ON THEM. MASTER AND CHIEF ENGINEER INDICATED THAT THEY NO LONGER USE THEM. HOWEVER, CLASS IS WANTS THEM PERMANENTLY REPAIRED, REMOVED OR REPALCED BY MAY 95.
Electrical
Issued 16 November 1994
Resolved
SEVERAL ELECTRICAL JUNCTION BOXES FOR THE ENGINE ROOM EXHAUST AND SUPPLY VENTS ARE WASTED. ALL ARE LOCATED BEHIND THE ACCOMMODATION HOUSE. THEY HAVEBEEN INSPECTED BY CLASS. PERMANENT REPAIRS MUST BE MADE TO THE SATISFACTIONOF CLASS BY MAY 95.
Engineering
Issued 16 November 1994
Resolved
STARBOARD SIDE HYDRAULIC LINE IS LEAKING IN SEVERAL AREAS. TEMP REPAIRS HAVE BEEN MADE. CLASS HAS INSPECTED AN ACCEPTED TEMPS. PERMANENT REPAIRS MUST BE MADE TO CLASS SATISFACTION BY MAY 95.
Engineering
Issued 16 November 1994
Resolved
BOTH THE STEAM LINE ON THE DECK AND INSIDE THE ENGINE ROOM HAVE SEVERAL HOLES IN IT. CLASS IDENTIFIED PROBLEMS WITH THE STEAM LINES IN MARCH 94. ITAPPEARS THEM HAVE INCREASED IN HOLES AND LEAKS. CLASS IS REQUIRING REPAIRS TO BE MADE PERMANENT BY MAY 95.
Lifesaving
Issued 16 November 1994
Resolved
BOTH PORT AND STARBOARD PNEUMATIC AIR LINES TO OPERATE THE BOAT WINCH ARE HOLED. THEY HAVE FIBERGLASSED OVER THESE AS TEMPORARY MEASURES. CLASS HAS INSPECTED THESE AND HAS REQUIED PERMANENT REPAIRS BE MADE BY MAY 95
Engineering
Issued 16 November 1994
Resolved
THE ENGINE ROOM EXHAUST GAS BOILER DRAIN PALTE IS WASTED. TEMPORARY REPAIRSHAVE BEEN MADE AND INSPECTED BY CLASS. PERMANENT REPAIRS MUST BE MADE TO THE CLASS SATISFACTION BY MAY 95.
Deck/Cargo
Issued 16 November 1994
Resolved
THE IGS PIPING HAS THREE HOLES IN IT. ALL OF THEM HAVE SOFT PATCHES ON THEM. CLASS HAS INSPECTED THEM AND APPROVED AS TEMPORARY. PERMANENT REPAIRSMUST BE MADE BY MAY 95.
Deck/Cargo
Issued 16 November 1994
Resolved
THE GOOSE NECK AIR VENT FOR THE DECK WATER SEAL HAS BROKEN OFF. THE VESSEL HAS PLUGED THE HOLE FOR NOW. CLASS HAS REQUIRED PERMANENT REPAIRS BE MADE BY MAY 95. ITEM IS LOCATED DIRECTLY BEHIND THE SEAL.
Navigation
Issued 4 November 1993
Resolved
REPAIR ECHO DEPTH RECORDING DEVICE.
Deck/Cargo
Issued 4 November 1993
Resolved
REPLACE BUTTERWORTH GASKETS.
Deck/Cargo
Issued 4 November 1993
Resolved
MAKE PERMANENT REPAIR TO PATCH ON NUMBER 7 PORT P/V VENT PIPING - APPROX 3 FEET SECTION IMMEDIATELY ABOVE MAIN DECK.
Engineering
Issued 13 November 1992
Resolved
VESSEL DID NOT HAVE SCUPPERS THAT CLOSED BY MECHANICAL MEANS. WOOD PLUGS AND CEMENT WERE USED.
Deck/Cargo
Issued 23 December 1988
Resolved
33 CFR 155.805(A) THE VESSEL HAD ON DECK TRANSFER HOSES NOT BEING USED FORTRANSFER WHICH WERE NOT BLANKED OFF WITH BUTTERFLY VALVES, WAGER-TYPE RESILIENT SEATED VALVES, BLANK FLANGES, OR OTHER MEANS ACCEPTABLE TO THE COTP.
Deck/Cargo
Issued 25 March 1988
Resolved
CARGO TRANSFER HOSES NOT BLANKED OFF WHILE NOT IN USE AS REQUIRED BY 33 CFR 155.805 (A). ALL HOSES HAD BEEN USED BEFORE. VESSEL IS 19981 GROSS TONS. TRANSFER WAS NOT IN PROGRESS WHEN DISCREPANCY WAS NOTED.
Navigation
Issued 25 March 1988
Resolved
VESSEL MISSING LOCAL CHARTS, (NOAA CHARTS) 13223, 13224 AND 13225 AS REQUIRED BY 33 CFR 164.33 (A)(1)(I). VSL USES BA CHARTS FOR NAVIGATION, THERE ARE NO BA EQUIVALENTS FOR THESE CHARTS. THESE ARE MARINE CHARTS OF THE AREA TRANSITTED ON 25 MAR 88. VSL IS 19981 GROSS TONS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.