MAURY USCG vessel records Sign in
← All vessels

CRYSTALVENTURE

CRYSTALVENTURE is a 1980 tank ship. The Coast Guard has recorded 52 inspections since 1986, most recently in May 2001, along with 25 deficiencies — 8 with no resolution recorded — and 2 operational controls.

Records from 1986 to 2001. Most recent: inspection, 22 May 2001.

Built
1980
Last inspected
22 May 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7904085 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
GREECE
—
Maury page id
psix-53898

Inspections, by type

…with no type recorded39
…past their stated due date8
Years with a record 15 calendar years (1986–2001)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18812 - Regulatory (Subpart C or D), Gross Ton
11923 - Regulatory (Subpart C or D), Net Ton
31176 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

22 May 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 290185
16 May 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290154
16 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068387
21 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428983
21 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 806264
18 March 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 499112
18 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786813
28 May 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 773667
4 October 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 514005
23 March 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389154
23 March 1996 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078937
17 November 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 384870
18 July 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 380657
5 July 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 380122
5 July 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 882788
30 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 669493
26 June 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882032
19 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379513
19 June 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1190319
7 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 375084
7 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1370990
24 January 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 691686
23 January 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 374487
23 January 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839309
19 September 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 459465
11 May 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 366637
10 May 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 669494
23 April 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 54235
23 April 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 527830
23 April 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1168648
13 January 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 669495
2 January 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 54167
29 December 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423855
8 February 1993 MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145282
19 May 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 508863
1 November 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 647283
18 October 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 485585
18 October 1991 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 937934
9 December 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 340752
9 December 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931896
2 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 334510
27 December 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 492250
25 August 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 332235
10 August 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 332029
10 August 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1041439
10 February 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 321160
10 February 1988 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1328090
13 May 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 495828
13 May 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1331454
6 May 1987 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1325187
13 July 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310170
13 July 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988647

Deficiency record · 25

Deck/Cargo
Issued 22 May 2001 No resolution recorded
HIGH LEVEL ALARM LIGHT ON STARBOARD SIDE INOPERABLE(46 CFR 39.20)REPAIR PRIOR TO NEXT US PORT.
Condition: Unknown
Due 23 May 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 16 May 2001 No resolution recorded
High level alarm is showing a loop failure light during operation. (SOLAS 74A Reg. I/11) Provide Class report proving proper operation of system prior to using VCS in U.S. waters.
Condition: Unknown
Due 16 May 2001 — due date passed with no resolution recorded
Documentation
Issued 16 May 2001 No resolution recorded
P&A Manual lists of cargoes in Sec.4 Table 1 does not match cargoes listed in Certificate of Fitness. MARPOL Annex II/5). Provide class report clarifying this discrepancy.
Condition: Unknown
Due 16 June 2001 — due date passed with no resolution recorded
Electrical
Issued 16 May 2001 No resolution recorded
All four generators are missing the jacketed piping around high pressure fuel lines. (SOLAS 74A Reg. II-2/15.2.9) Provide proper jacketing to satisfaction of class.
Condition: Unknown
Due 16 June 2001 — due date passed with no resolution recorded
Documentation
Issued 16 May 2001 No resolution recorded
IOPP Certificate incorrectly lists vessel as a crude oil/product carrier vice product carrier and does not list clean ballast tanks in accordance with MARPOL Annex I 13A. (MARPOL Annex I/4) Provide class report clarifyingthese items.
Condition: Unknown
Due 16 June 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 16 May 2001 No resolution recorded
Vessel unable to demonstrate operation of Inert Gas System._x001C_ (SOLAS 74A II-2/62). Prove proper operation prior to carriage of any cargoes that require IGS in U.S. waters_x001C_
Condition: Unknown
Due 16 June 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 16 May 2001 No resolution recorded
Steam piping on cargo deck found severely wasted. (SOLAS 74A Reg. I/11) Provide Class report attesting to integrity of piping system prior to use but no later than 16JUN01.
Condition: Unknown
Due 16 June 2001 — due date passed with no resolution recorded
Electrical
Issued 16 May 2001 No resolution recorded
Repair numerous minor fuel oil leaks noted on all four generators. (SOLAS 74A Reg. I/11)
Condition: Unknown
Due 30 May 2001 — due date passed with no resolution recorded
Lifesaving
Issued 19 June 1995 Resolved
Ensure vessel is sufficiently crewed with personnel holding valid certificates and licenses in accordance with minimum safe manning certificate prior to departure from Guayanilla, Puerto Rico.
Condition: Unknown
Due 19 June 1995
Resolved 23 June 1995
Navigation
Issued 19 June 1995 Resolved
VESSEL'S ARPA WAS NOT PERFORMING ACCORDING TO I.M.O. STANDARDS DUE TO FAILURE OF SPEED LOG THAT INPUT SPEED AND DISTANCE TRAVELED BY VESSEL. MUST BE CORRECTED PRIOR TO NEXT DRYDOCK NOT LATER THAN 31MAY96.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Navigation
Issued 19 June 1995 Resolved
VESSEL'S SPEED LOG HAS NOT BEEN WORKING SINCE FEBRUARY, RENDING THE VESSEL'S ARPA INOPERABLE SINCE IT LACKS THE AUTOMATIC IMPUT OF SPEED AND DISTANCE TRAVELED BY THE VESSEL. MUST BE CORRECTED BY NEXT DRYDOCK NLT 31MAY96.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Deck/Cargo
Issued 19 June 1995 Resolved
HOSES STOWED ON DECK NOT BLANKED OFF AS REQUIRED WHEN NOT IN USE.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Electrical
Issued 19 June 1995 Resolved
CLASSIFICATION SOCIETY TO ENSURE EMERGHENCY GENERATOR FUNCTIONS PROPERLY UNDER BLACKOUT CONDITIONS PRIOR TO DEPARTING GUAYANILLA, PUERTO RICO.
Condition: Unknown
Due 19 June 1995
Resolved 23 June 1995
Fire Fighting
Issued 19 June 1995 Resolved
Classification Society to ensure all fire screen doors close properly priorto handling cargo in next U.S. port.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Deck/Cargo
Issued 7 February 1995 Resolved
VESSEL STARTED CARGO TRANSFER OPERATIONS WHILE THE IGS OXYGEN CONCENTRATIONMONITOR AND RECORDING DEVICE WERE NOT IN OPERATING ORDER IN VIOLATION OF 46 CFR 32.53-60(b)
Condition: Unknown
Due 7 February 1995
Resolved 8 February 1995
Unknown
Issued 7 February 1995 Resolved
LOADLINE ON STARBOARD SIDE WAS NOT PAINTED IN A CONTRASTING COLOR AS REQUIRED BY 46 CFR 42.13-40
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Deck/Cargo
Issued 7 February 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 February 1995
Resolved 8 February 1995
Deck/Cargo
Issued 7 February 1995 Resolved
FOURTEEN (14) OF TWENTY SIX (26) INDIVIDUAL CARGO TANK PRESSURE GAUGES LOCATED ON THE BRIDGE WERE NOT INDICATING ANY IGS PRESSURE ON THE TANKS AS REQUIRED BY 46 CFR 32.53-30.
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Unknown
Issued 23 January 1995 Resolved
AS PER MIO NY INSPECTION REQ; DEMONSTRATE PROPER OPERATION OF INSTALLED IGS OXYGEN ANALYZER PRIOR TO CARGO TRANSFER AT NEXT U.S. PORT.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Navigation
Issued 23 January 1995 Resolved
CHART 13354 WAS NOT CORRECTED TO DATE.
Condition: Unknown
Due 24 January 1995
Resolved 24 January 1995
Documentation
Issued 18 October 1991 Resolved
PRIOR TO DEPARTING THE PORT OF BOSTON PROVIDE SATISFACTORY EVIDENCE TO THE MARINE SAFETY OFFICE BOSTON THAT VESSEL IS IN COMPLIANCE WITH ITS EFFECTIVEMANNING CERTIFICATE BY OBTAINING A CHIEF MATE, OR BY A WAIVER FROM THE VESSEL'S FLAG ADMINISTRATION.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Deck/Cargo
Issued 9 December 1990 Resolved
COMPLETE NECESSARY REPAIRS TO STOP SLOW LEAK FROM #4 CARGO MANIFOLD AT PT_x001C_ SIDE CARGO CONTAINMENT. THIS REQUIREMENT TO BE COMPLETED TO SATISFACTION OFUSCG MARINE INSPECTOR PRIOR TO DEPARTING THE PORT OF NEW YORK.
Condition: Unknown
Due 9 December 1990
Resolved 9 December 1990
Fire Fighting
Issued 9 December 1990 Resolved
COMPLETE PERMANENT REPAIRS TO CRACKED WELD IN FIREMAIN ON CARGO DECK IN WAYOF #4 CTR CARGO TANK TO THE SATISFACTION OF A USCG MARINE INSPECTOR PRIOR TO LOADING CARGO IN U.S. WATERS OR TRANSPORTING CARGO TO A U.S. PORT. A _x001C_ TEMPORARY PATCH WAS APPLIED TO THE CRACK AND SATISFACTORY TEST OF FIREMAIN
Condition: Unknown
Due 9 December 1990
Resolved 9 December 1990
Documentation
Issued 10 August 1989 Resolved
AT NEXT U.S. PORT OBTAIN CURRENT SOE ENDORSEMENT FOR LOC.
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Documentation
Issued 10 February 1988 Resolved
A VIOLATION OF 33 CFR 164.11(Q) IN THAT THE PRE-ARRIVAL TESTS REQUIRED BY 33 CFR 164.25(A) WERE NOT RECORDED IN THE VESSEL'S LOG.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.