Records from 1982 to 1996. Most recent: inspection, 17 April 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 52
17 April 1996
Administrative
Administrative · Activities Europe · Activity 1080960
8 April 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077938
26 February 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193032
12 December 1995
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 878338
30 November 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 884419
4 May 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346401
5 April 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1360073
4 December 1994
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135548
13 November 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 36085
4 August 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862502
18 May 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869123
7 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1167982
9 March 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165766
21 April 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826980
14 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258746
5 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270770
5 September 1991
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 948623
19 August 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 941051
31 July 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 941086
29 July 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 651402
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925760
30 April 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1215542
12 April 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1219291
14 December 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928528
23 September 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1300197
21 May 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212837
9 April 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909421
29 March 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921788
26 June 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033122
12 June 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 892871
4 April 1989
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040247
2 February 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 899268
4 April 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035151
22 January 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323501
8 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320939
15 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327119
18 June 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323427
13 March 1987
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1325987
9 January 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314738
12 September 1986
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1312402
10 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296810
29 November 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1302971
28 August 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988896
14 August 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983587
3 June 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290677
8 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283783
28 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975061
6 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977333
13 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277905
26 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972019
20 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963369
9 April 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279717
Construction/Loadline
Issued 4 December 1994
Resolved
RENEW WASTED PLATE COVERING AFT STBD PART OF DRAWWORKS, AFT OF DRILLER'S SHED.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 4 December 1994
Resolved
PROVIDE REQUIRED CONDENSED MILK PER PERSON (44LBS) FOR EACH LIFEBOAT.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Construction/Loadline
Issued 4 December 1994
Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL DAMAGE IWO PRE-LOAD TANKS 1C AND 2S TOSATISFACTION OF ATTENDING ABS SURVEYOR.
Condition: Unknown
Due 31 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 December 1994
Resolved
INSTALL NEW SPRINKLER PUMP FOR WATERCRAFT LIFEBOAT AND PROVE PROPER OPERATION.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Construction/Loadline
Issued 4 December 1994
Resolved
RENEW LOWER PLATE (APPROX. 8FT X 8FT) OF INBOARD STBD BULKHEAD IN POTABLE WATER ROOM THAT IS COMMON WITH PRE-LOAD TANK #2P. BULKHEAD HAS FIVE DOUBLERS OVER PREVIOUS LEAKS.
Condition: Unknown
Due 31 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 December 1994
Resolved
CONTINUE WITH RENEWAL OF WASTED SIDE SHELL AND UNDERDECK STIFFENERS IN PRE-LOAD TANKS #6P,7P, AND 7S TO SATISFACTION OF ABS SURVEYOR.
Condition: Unknown
Due 31 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 4 December 1994
Resolved
RENEW CRACKED NITROGEN CHARGING HOSE FOR 150LB, B-V DRY CHEM EXTINGUISHER FOR HELIDECK.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Construction/Loadline
Issued 4 December 1994
Resolved
RENEW SEVERELY CRACKED EXPANSION JOINTS ON ENGINE FRESH WATER SUPPLY FOR #1AND #3 GENERATORS.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Construction/Loadline
Issued 4 December 1994
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED DECK ON AFT END OF DRILL FLOOR TO MAKE FLUSH WITH REST OF DRILL FLOOR.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Lifesaving
Issued 4 December 1994
Resolved
RENEW EXPIRED RED PARACHUTE FLARES IN CONTROL HOUSE.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Lifesaving
Issued 4 December 1994
Resolved
RENEW LIFEBOAT DAVIT FALLS.
Condition: Unknown
Due 4 December 1994
Resolved 4 December 1994
Construction/Loadline
Issued 4 August 1994
Resolved
PROVIDE COPIES OF ALL REPORTS AND VIDEOS CONNECTED WITH THE ABS WITNESSED UNDERWATER SURVEY OF SEP 1994.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Lifesaving
Issued 9 March 1994
Resolved
HYDROTEST OR REPLACE ALL AIR SUPPLY CYLINDERS IN BOTH LIFEBOATS.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Fire Fighting
Issued 9 March 1994
Resolved
HYDROTEST OR REPLACE BOTH NITROGEN PROPELLANTS FOR SEMI PORTABLE FIRE EXTINGUISHERS ON HELIDECK.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Lifesaving
Issued 21 April 1993
Resolved
PROVIDE COPY OF CURRENT VALID FOUR (4) INFLATABLE LIFERAFT SERVICING REPORT.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Fire Fighting
Issued 5 April 1992
Resolved
INSTALL CONTROL HEAD FOR 25 SECOND, KIDDE TIME DELAY ON MACHINERY SPACE FIXED, EXTINGUISHING SYSTEM (CO2)
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Lifesaving
Issued 5 April 1992
Resolved
INSTALL 2, 20 PERSON DAVIT LAUNCHED INFLATABLE LIFERAFTS WHICH HAVE BEEN SERVICED AT A USCG APPROVED FACILITY AND WITNESSED BY A MARINE INSPECTOR WITH IN THE LAST TWELVE MONTHS. (LAST SERVICINGS 2/91 AND 4/91).
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 5 September 1991
Resolved
RENEW OR PROVIDE DATE OF MANUFACTURE FOR ALL NON-METALLIC EXPANSION JOINTS_x001C_IN VITAL SERVICE.
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Construction/Loadline
Issued 19 August 1991
Resolved
EXAMINE DEFECTS IN MODIFIED LEG TO SPUD CAN CONNECTIONS DESCRIBED IN PARAGRAPH 3.D. OF ABS AMERICAS TELEFAX MESSAGE S-1 OF 14 AUGUST 1991 PRIOR TO DEPARTING FOR NIGERIA.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Unknown
Issued 30 April 1991
Resolved
MAKE REPAIRS AND TEST OPERATION OF EMERGENCY GENERATOR IN AUTO MODE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Unknown
Issued 12 April 1991
Resolved
MAKE REPAIRS AND TEST OPERATION OF EMERGENCY GENERATOR IN AUTO MODE.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Construction/Loadline
Issued 9 April 1990
Resolved
SUBMIT REPAIR PROPOSAL TO [name withheld] FOR DAMAGE TO PORT AFT LEG AND STBD AFT LEG GUIDE.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Unknown
Issued 29 March 1990
Resolved
PROVIDE AND INSTALL A U.S.C.G. APPROVED DAVIT LAUNCH LIFERAFT HOOK ON THE STBD DAVIT. HOOK IS TO HAVE A VALID INSPECTION (WITHIN 1 YEAR) BY U.S. COAST GUARD MARINE INSPECTOR. VESSELS COMPLIMENT OF PERSONAL IS LIMITED TO A TOTAL OF 40 PERSON UNTIL THIS IS COMPLETED (MAX PERSON ABOARD).
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Electrical
Issued 26 June 1989
Resolved
PROVIDE VISUAL ALARM AT DRILLER CONSOLE OR AUDIBLE ALARM ON DOG HOUSE. 46CFR 111.105(F)(3) AND NFPA 496 3-3.1 TYPE Z PURGING THROUGH 3-3.8. SEE 2-3.4 FOR NAMEPLATE INFORMATION.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Lifesaving
Issued 26 June 1989
Resolved
PROVIDE CABLE CERTIFICATE FOR NEW CABLES ON LIFEBOAT.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Unknown
Issued 26 June 1989
Resolved
REMOVE HANDS FREE DEVICES FROM FUELING EQUIPMENT.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Electrical
Issued 4 April 1989
Resolved
REPLACE ALL TYPE "SO" AND UNAPPROVED CABLE IN THE LOGGING SHACK AREA DRILL FLOOR SUB STRUCTURE #1 LIFEBOAT DECK SPOT LIGHTS AND #2 LIFEBOAT DECK OVERHEAD.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
MAKE A PROPER SPLICE OF THE ELECTRICAL CABLE BELOW THE PORTSIDE OF THE DRILL FLOOR.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989
Resolved
PROVIDE NINE (9) APPROVED PFD'S.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
REPLACE OR REMOVE NON CLASSED 4 PRONG RECEPTICLE UNDER LADDER LEADING TO SHAKER DECK.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
REMOVE SO TYPE CABLE RUN THROUGH SHAKER AREA.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
INSTALL A BREAKER OR SPACER IN EMPTY SPACE IN ENGINE ROOM PRELUBE PANEL.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
REPLACE BATTERY CABLE CONNECTORS FOR EMERGENCY GENERATOR BATTERIES WITH APPROVED CONNECTORS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
INSTALL AN AUDIBLE OR VISUAL LOSS OF PURGE ALARM FOR REMOTE MUD PUMP CONTROL PANEL AND PROVIDE A CLEAN/DRY AIR SUPPLY.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 2 February 1989
Resolved
MAKE PORT AND STARBOARD LIFEBOAT INSTALLATIONS AS ORIGINAL PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Fire Fighting
Issued 18 June 1987
Resolved
ALL PORTABLE FIRE EXTINGUISHERS NOT HYDRO TESTED WITHIN THE LAST FIVE YEARSMUST BE TESTED. ALSO PROVIDE APPROPRIATE NUMBER OF SPARE EXTINGUSIHERS ON BOARD (I.E. ONE SPARE FOR EACH DIFFERENT TYPE PORTABLE EXTINGUISHER).
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
PREPARE MUD PIT DUMP VALVES AND SHALE SHAKER DUMP VALVES FOR VISUAL INSPECTION. SEE SPECIAL INSTRUCTIONS BELOW.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
COMPLETE UNDERWATER SURVEY OF SPUD CANS. SEE SPECIAL INSTRUCTIONS BELOW.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
MAKE OPERABLE OR RENEW DUMP VALVES IN NUMBER SIX PRE LOAD TANKS PORT AND STBD SIDES AND PRE LOAD TANK NUMBER TWO PORT. EACH VALVE MUST CLOSE TIGHTLY AND OPEN SMOOTHLY.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
REPAIR OR REPLACE WASTED DOORS TO MUD PIT ROOMS. DOORS ARE NOT GAS TIGHT.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Fire Fighting
Issued 10 April 1986
Resolved
INSTALL HINGED OR SLIDING COVERS FOR EMERGENCY GENERATOR SPACE VENTILATING LUVERS TO COMPLY WITH REQUIREMENT FOR CLASS A FIRE BOUNDRY. SUBMIT PHOTOGRAPH OF SAME HAVING BEEN COMPLETED.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Fire Fighting
Issued 10 April 1986
Resolved
SUBMIT STATEMENT THAT THE 100 LB. CO2 BOTTLE THAT IS APPROXIMATELY 50 LBS LIGHT AS NUTE ON "FIRE BOSS" SERVICING CERT. HAS BEEN REPLACED OR RECHARGED.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Accommodation/Occupational Safety
Issued 10 April 1986
Resolved
MAKE AVAILABLE FOR INSPECTION THE AIR RECEIVER LOCATED UNDER THE DRILL FLOOR USED FOR DRILLING AIR.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Fire Fighting
Issued 10 April 1986
Resolved
SUBMIT EVIDENCE OF SATISFACTORY HYDRO AND SERVICING OF ONE KIDDY 150 POUNDBV FIRE EXTINGHER FOR HELO DECK OR REPLACE MENT OF SAME WITH ANOTHER SERVICED BV AS WAS NUTED ON THE "FIRE BOSS" SERVICING COMPANY CERTIFICATE OF INSPECTION DATED 09APR86.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Construction/Loadline
Issued 10 April 1986
Resolved
SUBMIT EVIDENCE OF A CONSTRUCTION PORTFOLIO WHICH WAS COAST GUARD APPROVED FOR THIS VESSEL AS REQUIRED BY 46 CFR 107.305 (HH).
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Lifesaving
Issued 10 April 1986
Resolved
SUBMIT COPIES OF THE LIFERAFT SERVICING CERTIFICATES FOR THE FOUR 20MAR B.F. GOODRICH DAVIT LAUNCH LIFERAFTS ON BOARD.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 3 June 1985
Resolved
CONDUCT AN OPERATIONAL TEST OF THE GENERATOR REVERSE POWER RELAYS FOR EACH GENERATOR AS PER 46 CFR 111.12-11(F).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Lifesaving
Issued 3 June 1985
Resolved
PROVIDE IN EACH LIFEBOAT A COAST GUARD APPROVED FLASHLIGHT AS REQUIRED BY 46 CFR 108.503(D) AND 46 CFR 94.20-15(J).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Electrical
Issued 3 June 1985
Resolved
CONDUCT AN OPERATIONAL TEST OF GENERATOR PRIME MOVERS OVERSPEED DEVICE AS PER 46 CFR 111.12-1(B).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Electrical
Issued 3 June 1985
Resolved
REMOVE THE IMPROPERLY RUN CABLE AND INSTRUMENTATION HOSES WHICH ARE INSTALLED THROUGH THE WATERTIGHT BULKHEADS BELOW THE MAIN DECK AND INSTALL AS REQUIRED BY 46 CFR 11.60-5(A).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Electrical
Issued 6 April 1984
Resolved
MAKE SUITABLE FOR DIVISION ONE HAZARDOUS LOCATIONS THE MUD PIT GAI-TRONICS PHONE. 46 CFR 111.92
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
REPAIR THE LOW LUBE OIL PRESSURE LIGHT AND ALARM TO THE NUMBER TWO GENERA- TOR. 46 CFR 61.20-3
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
MAKE SUITABLE FOR DIVISION TWO HAZARDOUS LOCATIONS THE FOUR (4) ALLEN BRAD-LEY MOTOR CONTROLLERS ON THE PORT SIDE AFT BULKHEAD OF THE SHALE SHAKER.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
MAKE SUITABLE FOR DIVISION TWO HAZARDOUS LOCATIONS THE GENERAL ALARM BELL IN THE SHALE SHAKER AREA. 46 CFR 111.92
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V YUCATAN, O.N. 645076
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984
Resolved
PROVIDE WRITTEN INSTRUCTIONS FOR THE LINE THROWING GUN AND THE REQUIRED 1500 FOOT AUXILIARY LINE. 46 CFR 108.517
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984
Resolved
REPAIR THE LADDER ON THE STARBOARD LEG. A SECTION OF THE LADDER IS MISSING46 CFR 108.525
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984
Resolved
PROVIDE A LENS FOR THE PORT OBSTRUCTION LIGHT. 33 CFR 66.01-35
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Accommodation/Occupational Safety
Issued 6 April 1984
Resolved
NON SKID THE FLIGHT DECK SURFACE. 46 CFR 108.235
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Fire Fighting
Issued 6 April 1984
Resolved
REPAIR THE OXYGEN-COMBUSTILE GAS INDICATOR FOR THE FIREMANS OUTFITS. THE GAS DETECTOR SIDE OF THE UNIT IS NOT OPERATING PROPERLY. 46 CFR 108.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984
Resolved
PROVIDE FIXED DISCHARGE CONTAINMENT UNDER THE PORT AND STARBOARD FUEL OIL HOSE CONNECTIONS. 33 CFR 155.320
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
MAKE SUITABLE FOR DIVISION ONE HAZARDOUS LOCATIONS THE MUD PIT DEGASSER MOTOR CONTROLLER. 46 CFR 111.92
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
REMOVE THE CUT WIRES FROM THE PORT MUD PIT BULKHEAD. 46 CFR 111.92
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Fire Fighting
Issued 6 April 1984
Resolved
REPAIR THE OXYGEN-COMBUSTIBLE GAS INDICATOR FOR THE FIREMANS OUTFIT. THE ALARMS WERE NOT OPERATING ON THE UNIT. 46 CFR 108.497
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984
Resolved
SUBMIT A HAZARDOUS LOCATION PLAN TO THE OFFICER IN CHARGE, MARINE INSPEC- TION OFFICE, NEW ORLEANS FOR REVIEW. 46 CFR 107.305
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984
Resolved
SUBMIT A FIRE CONTROL PLAN TO THE OFFICER IN CHARGE, MARINE INSPECTION OFFICE NEW ORLEANS FOR PLAN REVIEW. THE REVIEW OF THE PLAN WILL INCLUDE AN
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984
Resolved
(CONT. 9) EVALUATION OF THE CURRENT FIRE STATION COVERAGE. 46 CFR 107.305
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984