Records from 1982 to 1987. Most recent: inspection, 17 February 1987.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 4 September 1985
Resolved
RENEW BATTERIES IN EMERGENCY HAND LANTERN.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 4 September 1985
Resolved
PROVIDE FCC OPERATORS PERMIT.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 September 1985
Resolved
MAKE SOLID WIRE CONNECTIONS ON ALL WIRE CONNECTIONS BY USING PRESSURE SPLICE CONNECTIONS OR BY SUITABLY SOLDERING AND TAPING ALL CONNECTIONS.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 September 1985
Resolved
PROVIDE COVER TO ELECTRICAL BOX OVER STEERING STATION.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 4 September 1985
Resolved
SERVICE FIRE EXTINQUISHERS.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 4 September 1985
Resolved
PROVIDE INFORMATION ON SOUTH CAROLINA'S POLICY ON OPERATING VESSEL SEASONALLY IN STATE OF FLORIDA.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 4 September 1985
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 September 1985
Resolved
PROVIDE SEVEN (7) ADDITIONAL ADULT LIFE JACKETS AND TWO (2) CHILD-SIZE JACKETS, TO BRING REQUIRED COMPLEMENT OF JACKETS TO 12 AND 3.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 September 1985
Resolved
PROVIDE SIX (6) ORANGE SMOKE FLARES WITH CURRENTLY VALID EXPIRATION DATES.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 4 September 1985
Resolved
REPAIR MASTHEAD AND STERN LIGHTS.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 September 1985
Resolved
PROVIDE 60 FT. OF LANYARD FROM LIFE RING TO VESSEL.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 September 1985
Resolved
CONNECT WATERLIGHT TO LIFERING.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 September 1985
Resolved
REPAIR INTERIOR LIGHT.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 September 1985
Resolved
TIGHTEN HANDRAILS.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 4 September 1985
Resolved
REPAIR TOILET HOUSE STRUCTURE.
Condition: Unknown
Due 30 September 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past