MAURY USCG vessel records Sign in
← All vessels

CORAL ISIS

CORAL ISIS is a 1982 tank ship. The Coast Guard has recorded 24 inspections since 1985, most recently in April 2009, along with 25 deficiencies — 6 with no resolution recorded — and 1 operational control.

Records from 1985 to 2009. Most recent: inspection, 7 April 2009.

Built
1982
Last inspected
7 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8024040 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NETHERLANDS
—
Maury page id
psix-53910

Inspections, by type

…with no type recorded18
…past their stated due date6
Years with a record 8 calendar years (1985–2009)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6788 - Convention (Subpart B), Gross Ton
2036 - Convention (Subpart B), Net Ton
6920 - Dead Weight, Ton
4049 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

7 April 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3448356
6 April 2009 COC-GAS Renew · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3447192
20 September 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3328826
20 August 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3302843
20 August 2008 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3303717
28 December 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 475945
19 October 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 443107
27 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 391605
10 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 392448
10 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1088827
10 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1245403
19 September 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382831
18 September 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 34675
1 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 377891
5 April 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376974
5 April 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1150816
10 August 1989 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1197836
19 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 443096
17 May 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 323367
17 May 1988 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1198271
21 October 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 492229
31 March 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020133
9 December 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305728
9 December 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990798

Deficiency record · 25

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 6 April 2009 No resolution recorded
Inert Gas Generator was found in inoperable condition. Repair Inert Gas Generator within 30 days and to the satisfaction of the Administration. SOLAS 74 Amend CH I-II
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 April 2009 No resolution recorded
Incinerator is inoperable. Make proper repairs to incinerator to operating status. SOLAS 74 Amend I-II
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Deck/Cargo › Cargo Heating › General
Issued 6 April 2009 No resolution recorded
Cargo heater #1 is inoperable. Make proper repairs. SOLAS 74 Amend I-II
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 6 April 2009 No resolution recorded
Cargo booster pump #2 is inoperable. Make proper repairs. SOLAS 74 Amend I-II
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Deck/Cargo › Ballast › Interface Detector
Issued 6 April 2009 No resolution recorded
Ballast Tank - Tank level indicators through out the system are inoperable. SOLAS 74 Amend I-II
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Construction/Loadline › Markings › Load Line Mark
Issued 6 April 2009 No resolution recorded
Load line marking on starboard side has faded. Mark load line marking in cotrasting colors. ICLL 66 Anex 1/8
Action required: 705 - Other - as specified
Due 7 May 2009 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 September 2008 Resolved
Vessel's primary rudder angle indicator is not operational. Vessel's secondary rudder angle indicator is operational. Master has made arrangement to repair primary rudder angle indicator at their next port of call. Cite: SOLAS 74 chapter 5 Reg 19(2.5.4)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 April 2009
Resolution: Conducted satifactory test of vessel''s primary rudder angle indicator and received Class Report for repair.
Fire Fighting
Issued 10 May 1996 Resolved
REPAIR DOOR LEADING TO ENGINE ROOM ESCAPE TRUNK AT AFTER STEERING TO SATISFACTION OF CLASSIFICATION SOCIETY. SOLAS 74 CHAP. II-2, REG. 53.
Condition: Unknown
Due 10 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 10 May 1996 Resolved
CARGO HOSE TO BE TESTED/MARKED I.A.W. 33 C.F.R. 156.170.
Condition: Unknown
Due 10 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 10 May 1996 Resolved
POST CORRECT FIRE PLAN AT ALL REQUIRED LOCATIONS. SOLAS 74, CHAP. II-2, REG. 20.
Condition: Unknown
Due 10 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE MISSING WARNING LIGHT OUTSIDE OF COMPRESSOR ROOM ENTRANCE FOR AIR LOCKS AS REQUIRED BY REG.3.6 OF GAS CODE.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Deck/Cargo
Issued 5 April 1995 Resolved
PRIOR TO CARRIAGE OF CARGOES REQUIRING INTER-BARRIER SPACES (VOIDS) TO BE INERTED, MAKE REPAIRS TO THE INERT GAS SYSTEM. PROVIDE CLASS SOCIETY REPORTATTESTING TO PROPER OPERATION OF ALL ALARMS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Lifesaving
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE GAS TIGHT SEALS FOR WHEELHOUSE DOORS AS REQUIRED BY REG.3.2.4 OF THE GAS CODE & 46 CFR 154.330.
Condition: Unknown
Due 5 May 1995
Resolved 19 September 1995
Fire Fighting
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO FIRE SPRAY SYSTEM WHERE PATCHED AFT OF THE MOTOR ROOM.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE ALL MISSING DIFFUSER HEADS ON DECK SPRAYSYSTEM.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Lifesaving
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE MISSING DIFFUSER HEADS ON EMERGENCY SHOWERS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Electrical
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE ALL MISSING PROTECTIVE CAGES ON LIGHTS IN COMPRESSOR ROOM.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Electrical
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE ALL INOPERABLE LIGHT BULBS IN COMPRESSORROOM.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Electrical
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPAIR/REPLACE EXPLOSION PROOF LAMP IN PAINT LOCKER.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Lifesaving
Issued 5 April 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Lifesaving
Issued 5 April 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE ALL MISSING BRACKETS (STAND-OFFS) ON DECK SPRAY PIPING (AROUND COMPRESSOR & MOTOR ROOM).
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Lifesaving
Issued 5 April 1995 Resolved
REPAIR/REPLACE ALL NON-OPERABLE WATER LIGHTS FOR RING BUOYS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Navigation
Issued 5 April 1995 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE VESSEL TURNING CIRCLE DIAGRAM/MANEUVERING INFO AS REQUIRED BY 33 CFR 164.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Unknown
Issued 31 March 1987 Resolved
VESSEL NOT IN COMPLIANCE WITH ANNEX II OF MARPOL 73/78, THE FOLLOWING CARGOES NOT AUTHORIZED AFTER 06APR87, ISOPRENE; PROPYLENE OXIDE, UNTIL VESSEL COMPLIES WITH ANNEX II.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.