SEAHORSE

SEAHORSE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 17 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 23 March 2026.

Built
1982
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4600
Flag
UNITED STATES
Maury page id
psix-53917

Documentation record

Registered dimensions (L × B × D)45.7 ft × 14.9 ft × 7.6 ft
Registered tonnagegross 37 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · DESTIN, FL, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

23 March 2026 Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8351250
19 March 2026 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8329050
19 December 2025 Internal Structural Exam · Drydock Exam · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285620
25 June 2025 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8168689
3 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8087607
17 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7914028
20 February 2024 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7867756
25 January 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852498
18 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7670712
20 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7653914
14 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7411627
10 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394718
8 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171742
8 April 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7226771
30 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900302
25 July 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6762605
5 March 2019 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634040
30 August 2018 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526774
29 March 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376161
31 August 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6251506
30 August 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5986757

Deficiency record · 17

05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 22 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2024
Resolved 17 May 2024
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 February 2024 Resolved
Supervisor training must be provided to a member of the crew to determine whether reasonable suspicion exits to require a drug and/or alcohol test. No one has been provided this training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2024
Resolved 17 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 April 2023
Resolution: Satisfactory smoke detection provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 August 2018 Resolved
Repair or replace emergency fuel shut off valve in fuel tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Installed new cable on affected line.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 August 2018 Resolved
Repair cracked floor frame aft of the collision bulkhead.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Removed cracked wood and FRP and installed new wood section with FRP overlay; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide UL approved bilge pump with at least 10GPM rate in space forward of the engine room.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Installed proper bilge pump inside the forward compartment; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Generator battery must be covered to be free from exposure to water splash or spray.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Solenoid installed on side of generator and proper battery cover placed over battery; all satisfactory.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 30 August 2018 Resolved
Provide SSB or FCC Satellite Phone Exemption Certificate. Vessel is restricted from operating beyond 20 NM from shore with passengers for hire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 March 2019
Resolution: Owner elected to Amend Route to Coastwise from Oceans, no longer requiring SSB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Replace flexible lines on bilge system with appropriate flexible nonmetallic hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Provided appropriate non-metallic flexible hose on affected sections; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide appropriate length of hose for portable bilge pump in order to be capable of reaching the bilge of each watertight compartment and discharging overboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Appropritate bilge hose provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide double hose clamps on vital system piping in affected areas throughout engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 31 August 2018
Resolution: Double hose clamps installed on affected piping; all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2018 Resolved
Provide appropriate lifejacket donning placard for each type of lifejacket carried on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Lifejacket donning placards provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 August 2018 Resolved
Mount vessel specific emergency instructions at the operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Emergency instructions updated.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 August 2016 Resolved
Provide two adult lifejackets
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 30 August 2016
Resolution: Life Jackets were provided
Engineering › Diesel Engine (auxiliary) › Block
Issued 30 August 2016 Resolved
Remove winch motor in collision bulkhead
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Motor was removed
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 30 August 2016 Resolved
coast pilot needs to be onboard
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Coast Pilot is onboard
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 30 August 2016 Resolved
Fuel shutoff valves need to be stenciled
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Fuel shut off valves were stenciled.