SEAHORSE

SEAHORSE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1982, most recently in March 2026, along with 119 deficiencies.

Records from 1982 to 2026. Most recent: inspection, 23 March 2026.

Built
1982
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP4600
Flag
UNITED STATES
367574440
Maury page id
psix-53917

Inspections, by type

…with no type recorded11
Years with a record 43 calendar years (1982–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.7 ft × 14.9 ft × 7.6 ft
Registered tonnagegross 37 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · DESTIN, FL, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4600MMSI 367574440 · active · compulsorily equipped · granted 5 March 2024, expires 5 March 2034
WDG8142MMSI 367574440 · expired · compulsorily equipped · granted 14 May 2013, cancelled 15 July 2023
WDC8615MMSI 367090230 · expired · compulsorily equipped · granted 1 February 2006, cancelled 2 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCQ3564MMSI not assigned · expired · compulsorily equipped · granted 17 March 1995, cancelled 21 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

23 March 2026 Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8351250
19 March 2026 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8329050
19 December 2025 Internal Structural Exam · Drydock Exam · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285620
25 June 2025 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8168689
3 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8087607
17 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7914028
20 February 2024 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7867756
25 January 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852498
18 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7670712
20 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7653914
14 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7411627
10 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394718
8 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171742
8 April 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7226771
30 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900302
25 July 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6762605
5 March 2019 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634040
30 August 2018 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526774
29 March 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376161
31 August 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6251506
30 August 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5986757
10 December 2015 Construction Oversight · Internal Structural Exam · Hull Examination · Plan Review "T" Boat · Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837545
25 August 2015 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5225458
22 May 2014 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4865031
9 May 2014 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4857841
14 January 2011 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3926816
26 January 2010 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3669704
10 February 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3413590
5 February 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3142434
13 November 2007 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3097483
23 January 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2861236
14 February 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2584734
13 December 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2551742
27 January 2005 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2281203
3 March 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2022633
10 February 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2003249
13 November 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1947143
15 March 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1758271
12 February 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1485782
4 December 2001 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1077371
29 January 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061167
24 February 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446942
7 December 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1389045
8 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421617
1 December 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032494
25 February 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414940
11 December 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434652
4 March 1997 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454435
5 March 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1433015
28 September 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 113451
23 May 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 874327
21 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412763
22 March 1994 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 855664
5 May 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149849
20 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150532
14 September 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 957909
3 June 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 949719
10 March 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 961798
30 July 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 936797
1 April 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226884
12 April 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221135
28 March 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 914542
23 August 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347541
12 April 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1041479
16 November 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 894658
6 April 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033783
13 May 1987 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314886
17 December 1986 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1026374
25 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998864
19 November 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 995190
10 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1293723
5 November 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 974588
22 November 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272412
8 November 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279376
13 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971949

Deficiency record · 119

05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 22 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2024
Resolved 17 May 2024
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 February 2024 Resolved
Supervisor training must be provided to a member of the crew to determine whether reasonable suspicion exits to require a drug and/or alcohol test. No one has been provided this training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2024
Resolved 17 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 April 2023
Resolution: Satisfactory smoke detection provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 August 2018 Resolved
Repair or replace emergency fuel shut off valve in fuel tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Installed new cable on affected line.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 August 2018 Resolved
Repair cracked floor frame aft of the collision bulkhead.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Removed cracked wood and FRP and installed new wood section with FRP overlay; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide UL approved bilge pump with at least 10GPM rate in space forward of the engine room.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Installed proper bilge pump inside the forward compartment; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Generator battery must be covered to be free from exposure to water splash or spray.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 31 August 2018
Resolution: Solenoid installed on side of generator and proper battery cover placed over battery; all satisfactory.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 30 August 2018 Resolved
Provide SSB or FCC Satellite Phone Exemption Certificate. Vessel is restricted from operating beyond 20 NM from shore with passengers for hire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 March 2019
Resolution: Owner elected to Amend Route to Coastwise from Oceans, no longer requiring SSB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Replace flexible lines on bilge system with appropriate flexible nonmetallic hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Provided appropriate non-metallic flexible hose on affected sections; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide appropriate length of hose for portable bilge pump in order to be capable of reaching the bilge of each watertight compartment and discharging overboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Appropritate bilge hose provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Provide double hose clamps on vital system piping in affected areas throughout engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 31 August 2018
Resolution: Double hose clamps installed on affected piping; all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2018 Resolved
Provide appropriate lifejacket donning placard for each type of lifejacket carried on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Lifejacket donning placards provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 August 2018 Resolved
Mount vessel specific emergency instructions at the operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Emergency instructions updated.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 August 2016 Resolved
Provide two adult lifejackets
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 30 August 2016
Resolution: Life Jackets were provided
Engineering › Diesel Engine (auxiliary) › Block
Issued 30 August 2016 Resolved
Remove winch motor in collision bulkhead
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Motor was removed
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 30 August 2016 Resolved
coast pilot needs to be onboard
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Coast Pilot is onboard
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 30 August 2016 Resolved
Fuel shutoff valves need to be stenciled
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Fuel shut off valves were stenciled.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 August 2015 Resolved
Provide valid FCC safety telephony certificate
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 31 August 2015
Resolution: Vessel provided certificate.
Operations/Management › Drills/Instruction › Fire
Issued 22 May 2014 Resolved
Crew members could not adequately conduct drills. Crew was provided two attempts and could not conduct crew drills safely.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2014
Resolution: Crew conducted drills to the satisfaction of the marine inspector.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 May 2014 Resolved
EPIRB battery is expired.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: EPIRB was provided a new battery.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 May 2014 Resolved
Provide 2 portable lights.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vessel corrected def by providing two portable lights.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 May 2014 Resolved
Vessel does not have the 4 required alcohol test strips to meet the 2 hour requirement.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vessel recieved and has onboard the required alcohol test strips.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 22 May 2014 Resolved
Vsl to remove fishing poles that were blocking the emergency escape route in the berthing.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vsl removed poles from emergency egress route.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 May 2014 Resolved
Vsl has to provide emergency lighting.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vsl installed emergency lighting.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2014 Resolved
Vsl was unable to provide fist aid kit
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vsl had first aid kit at inspection.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 May 2014 Resolved
Vsl did not have a U.S. Coast Pilot or NAVRUL's.
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Vsl recieved the proper navigational pubs at inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 May 2014 Resolved
Complete a COI exam to the satisfaction of attending marine inspector. Vessel Annual exam is past due as of 26Apr2014
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2014
Resolution: Conducted COI exam.
Lifesaving › Lifefloat › Serviceable
Issued 14 January 2011 Resolved
Replace 15 person life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2011
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 January 2011 Resolved
Repair E/R high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 January 2011 Resolved
Repair port & stbd bow rail sections marked.
Due 22 February 2011
Resolved 9 March 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 January 2011 Resolved
Update first aid equipment.
Due 22 February 2011
Resolved 9 March 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 January 2011 Resolved
Repair light & junction box in aft section of E/R & remove dead end wire near stbd exhaust.
Due 22 February 2011
Resolved 9 March 2011
Engineering › Steering Gear System › Linkage
Issued 26 January 2010 Resolved
Renew deteriorated bond wire to underwater through hull fittings (strut, rudder, sea valves) in stern compartment. ref. 46CFR 182.30-1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined and found satisfactory bonding wires for all through hull fittings in stern compartment.
Electrical › Electric Generation Source (service) › Generator
Issued 26 January 2010 Resolved
Repair and prove operation of generator hertz meter as required by 46 CFR 183.10-5.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined new hertz meter installation and found to to be good working order.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 January 2010 Resolved
Tighten all deck railing connections and rail base to deck connections as per 46 CFR 177.35-1 to the satisfaction of the attending marine inspector..
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined deck rail connections and were found to be sound condition.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 January 2010 Resolved
Provide one additional TYPE I adult life jacket for a maximum of 24 adult life jackets as per the vessels current Certificate of Inspection as required by 46 CR 180.30-5.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined one addition CG Approved Type I Adult life jacket and found in satisfactory condition.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 January 2010 Resolved
Repair or renew securing mechanism to transom door assembly in order to maintain transom deck rail continuity as required by 46 CFR 176.25-50(a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined and found satisfactory new door locking assembly.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 26 January 2010 Resolved
Replace existing 150 psi relief valve to a hot water storage tank with a 100 psi relief valve as required by 46 CFR 176.25-30 to prevent storage tank from being inspected as a pressure vessel. .
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: Examined and found satisfactory the installation of a 75 psi pressure relief valve to the hot water storage tank.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 January 2010 Resolved
Renew valve stem and valve handle to MSD overboard discharge valve located outboard of hot water storage tank in accordance with 46 CFR 178.40-1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 11 February 2010
Resolution: New valve was installed and found satisfactory.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 26 January 2010 Resolved
Double hose clamp generator exhaust hose connector to muffler. ref. 46CFR182.15-20
Condition: Improper Installation
Due 26 February 2010
Resolved 11 February 2010
Fire Fighting › Ventilation Systems › Grouping
Issued 26 January 2010 Resolved
Seal openings to forward and aft machinery space bulkhead maintain vapor tightening of space. ref. 46CFR181.20-1
Due 26 February 2010
Resolved 11 February 2010
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 26 January 2010 Resolved
Repair fresh water leak on generator fill/expansion tank piping. ref. 46CFR183.10-10
Condition: Improper Installation
Due 26 February 2010
Resolved 11 February 2010
Engineering › Fuel Oil Service System › Hose
Issued 26 January 2010 Resolved
Repair/Renew bonding wire to fuel oil fill connection that are loose and or deteriorated. ref 46CFR182.20-25
Condition: Improper Installation
Due 26 February 2010
Resolved 11 February 2010
Electrical › Electric Generation Source (service) › Switch
Issued 26 January 2010 Resolved
Clean electrical terminal block in fuel tank space to remove corrosion and renew neutral wire connection to bilge pump in space.
Condition: Improper/Lack of Maintenance
Due 26 February 2010
Resolved 11 February 2010
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 26 January 2010 Resolved
Renew deteriorated live bait well overboard discharge hose (port side) outboard main engine.
Condition: Improper/Lack of Maintenance
Due 26 February 2010
Resolved 11 February 2010
Engineering › Electric Propulsion System › Battery
Issued 26 January 2010 Resolved
Renew starboard main engine starting battery box. ref. 46CFR183.05-20
Condition: Improper/Lack of Maintenance
Due 26 February 2010
Resolved 11 February 2010
Lifesaving › Lifefloat › Lifeline
Issued 26 January 2010 Resolved
Renew deteriorated lifelines, grab lines to life float and renew retroflective material to back of lifeboat. ref. 46CFR180.15-5
Condition: Improper/Lack of Maintenance
Due 26 February 2010
Resolved 11 February 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 January 2010 Resolved
Provide US Coast pilot on board vessel. ref 46CFR185.20-35
Condition: Unknown
Due 26 February 2010
Resolved 11 February 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 26 January 2010 Resolved
Repair and prove operation of main engine RPM gauges. ref. 46CFR182.4.10
Condition: Improper Installation
Due 26 February 2010
Resolved 11 February 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 February 2009 Resolved
Provide current Light List, Coast Pilot [name withheld], and NOAA chart for vessel.
Due 24 February 2009
Resolved 19 February 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 10 February 2009 Resolved
Replace Emergency Broadcast placard for VHF radio.
Due 24 February 2009
Resolved 19 February 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 February 2009 Resolved
Replace 8 adult life preservers and 1 child lifejacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2009 Resolved
Tighten port bow rail.
Due 24 February 2009
Resolved 19 February 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 10 February 2009 Resolved
Label emergency exit on bow.
Due 24 February 2009
Resolved 19 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 February 2009 Resolved
Remove excess wires under helm station.
Due 24 February 2009
Resolved 19 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2008 Resolved
Rewire float switch to transverse bulkhead located on the forward portion of the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2008 Resolved
Remove old wiring forward of engines.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Electrical › Electric Generation Source (service) › Switch
Issued 5 February 2008 Resolved
Replace or secure generator starting box.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Engineering › Fuel Oil Service System › Filter
Issued 5 February 2008 Resolved
Repair or remove old fuel filters and associated fuel lines.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Navigation › Piloting/Steering › Marine Charts
Issued 5 February 2008 Resolved
Obtain 1 chart of area of operation.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2008 Resolved
Repair frayed wires on starboard side of generator.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 February 2008 Resolved
Replace 3 type I life jackets.
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 28 February 2008
Lifesaving › Lifefloat › Markings
Issued 5 February 2008 Resolved
Stencil name of vessel on life float in 3" bold letters.
Action required: 705 - Other - as specified
Due 5 February 2008
Resolved 5 February 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 January 2007 Resolved
Replace/repair magnetic compass. Noted to be 100 degrees out and cracked. 46CFR184.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 January 2007 Resolved
Obtain Tide and Current Tables for 2007. 46CFR184.420
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 January 2007 Resolved
Replace/repair all navigation lights. Noted bulbs to be dim and lenses to be clouded. COLREGS
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Communications › Audible Communications › Horn/Whistle
Issued 23 January 2007 Resolved
Repair sound producing device. Device must be capable of producing long and short blast. 33CFR86
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 January 2007 Resolved
Mark upper deck "NO PASSENGERS". 46CFR185.602
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 January 2007 Resolved
Install suitable junction boxes for electrical connections on all electrical connections on all electric bilge pumps.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 23 January 2007 Resolved
Install overcurrent protection for electrical bilge pump system.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 23 January 2007 Resolved
Renew fuel oil stop valves at each propulsion engine. Secure "oil change pump" for going to sea.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 January 2007 Resolved
Refasten bow rail on port side.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 23 January 2007 Resolved
Install/secure and connect racor strainer on port engine.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Lifesaving › Lifefloat › Painter
Issued 23 January 2007 Resolved
Fasten painter to body of lifefloat.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 8 February 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 February 2006 Resolved
Double clamp and secure starboard raw water hose as required by 46 CFR 182.420.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 February 2006 Resolved
Clean battery cables, connections, and boxes as required by 46 CFR 176.806.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 15 February 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 February 2006 Resolved
Replace overboard sewage valve as required by 46 CFR 176.818.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 15 February 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 February 2006 Resolved
Demonstrate proper operation of pull handle on fixed fire fighting system as required by 46 CFR 176.810(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 February 2006 Resolved
Replace (4) adult life jackets as required by 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 February 2006 Resolved
Demonstrate proper operation of bilge high water level alarms as required by 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 14 February 2006 Resolved
Properly port Emergency Broadcast placard as required by 46 CFR 184.506.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 15 February 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 January 2005 Resolved
Provide 2005 Tide and Tidal Current publications IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 14 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 January 2005 Resolved
Post PFD Donning Instructions in main passenger space IAW 46 CFR 185.516
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 14 February 2005
Resolution: .
Communications › Radio Communications › EPIRB
Issued 27 January 2005 Resolved
Move EPIRB to float free position IAW 46 CFR 180.64
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 14 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 January 2005 Resolved
Refasten forward starboard deck rail.
Action required: 705 - Other - as specified
Due 27 February 2005
Resolved 14 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 January 2005 Resolved
Service fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2005
Resolved 14 February 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 January 2005 Resolved
Provide proof that crewmembers are enrolled in drug testing program IAW 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2005
Communications › Radio Communications › EPIRB
Issued 27 January 2005 Resolved
Renew EPIRB hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2005
Resolved 14 February 2005
Navigation › Piloting/Steering
Issued 10 February 2004 Resolved
Provide up to date navigation pubs as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 3 March 2004
Resolution: Owner provided up to date nav pubs.
Navigation › Piloting/Steering
Issued 10 February 2004 Resolved
Provide bell as required by 33 CFR 86. LEGACY COMPONENT DESC: Bell
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 3 March 2004
Resolution: Owner provided bell.
Engineering › Sea-water System (primary cooling)
Issued 10 February 2004 Resolved
Replace salt water suction hose for ship service generator with CG approved hoseas required by 46 CFR 182.710. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 3 March 2004
Resolution: Owner replaced generator hose with approved hose.
Stability › Watertight Integrity
Issued 10 February 2004 Resolved
Make collision bulkhead access watertight as required by 46 CFR 171.114. LEGACY COMPONENT DESC: Collision Bulkhead
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 3 March 2004
Resolution: Owner made collision bulkhead access watertight.
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Renew main transverse under deck beam port to stbd - renew in kind or submit repair proposal. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 17 December 2003
Resolution: Examined, found sat.
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Remove angel hair and surface rot on port and stbd rudder tables and treat with rot preventor. LEGACY COMPONENT DESC: Rudder Tables
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 17 December 2003
Resolution: Examined, found sat.
Stability › Watertight Integrity
Issued 4 December 2001 Resolved
Renew Gasket steering compt hatch. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2001
Resolved 4 December 2001
Resolution: Owner operator renewed gasket, tested satisfactory.
Electrical
Issued 4 March 1997 Resolved
REPAIR OR REPLACE DAMAGED GAUGE PANEL FOR THE GENERATOR FREQUENCY, CYCLE AND AMP METERS.
Condition: Unknown
Due 4 April 1997
Resolved 14 April 1997
Electrical
Issued 21 March 1995 Resolved
PROVIDE DOCUMENTATION THAT GENERATOR HAS BEEN DOWN-RATED FOR MARINE USE.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Accommodation/Occupational Safety
Issued 21 March 1995 Resolved
PROVIDE LOCK FOR MSD OVERBOARD VALVE.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Electrical
Issued 21 March 1995 Resolved
INSTALL METAL WIRE CLAMPS ON ALL OVERHEAD WIRE RUNS IN ENGINE ROOM AT INTERVALS OF 18 INCHES.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Electrical
Issued 21 March 1995 Resolved
PROVIDE PULLEY GUARD FOR GENERATOR PULEY.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Electrical
Issued 21 March 1995 Resolved
INSTALL BATTERY COVERS FOR ENGINE BATTERIES.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Navigation
Issued 21 March 1995 Resolved
PROVIDE BELL OF PROPER SIZE MEETING 72 COLREGS (7.9" OR 200MM).
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 21 March 1995 Resolved
PERMANENTLY ATTACH 60' LINE TO RING BUOY.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 21 March 1995 Resolved
PERMANENTLY ATTACH WATER LIGHT TO LIFE FLOAT.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Accommodation/Occupational Safety
Issued 21 March 1995 Resolved
INSTALL DOUBLE HOSE CLAMPS ON MSD OVERBOARD LINE.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Fire Fighting
Issued 3 June 1992 Resolved
SERVICE THREE B-II AND ONE B-I PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 3 June 1992 Resolved
PROVE PROPER OPERATION OF THE BILGE PUMPS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Engineering
Issued 3 June 1992 Resolved
REPAIR GROUNDING STRAP ON FUEL FILL LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Navigation
Issued 1 April 1991 Resolved
CLEAN RUNNING LIGHT LENS AND REPLACE CRACKED STBD LENS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Lifesaving
Issued 1 April 1991 Resolved
INSTALL RETROREFLECTIVE TO BOUYANT APPARATUS
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Electrical
Issued 1 April 1991 Resolved
INSTALL FREQUENCY METER FOR A/C GENERATOR_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Fire Fighting
Issued 1 April 1991 Resolved
INSTALL CG APPROVED FIRE EXTINGUISHER BRACKETS FOR ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Electrical
Issued 1 April 1991 Resolved
INSTALL WATER TEMP. GUAGE FOR GENERATOR PRIME MOVER.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Engineering
Issued 1 April 1991 Resolved
INSTALL U/L APPROVED FUEL FILTER/SEPERATOR FOR MARINE USE AND REMOVE EXISTING NON APPROVED TYPES
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Accommodation/Occupational Safety
Issued 1 April 1991 Resolved
PERMANTLY SECURE A/C COOLING PUMP
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Engineering
Issued 1 April 1991 Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM. SUCH WARNING SHALL BE VISIBLE OR AUDIBLE AT THEENGINE OPERATION STATION.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Engineering
Issued 1 April 1991 Resolved
INSTALL PLUGS ON CANNISTER TYPE FUEL FILTER AND REMOVE PET-COCKS
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Documentation
Issued 13 May 1987 Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Construction/Loadline
Issued 19 November 1985 Resolved
INSTALL NON-RETURNING FLAPS OVER THE FREEING PORTS.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985

Ownership record