Records from 1982 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 83
11 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8381109
4 April 2025
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8104943
13 February 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8077136
20 July 2024
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7962845
9 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7909100
12 July 2023
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7858564
1 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7678538
14 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7637010
4 January 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7617002
8 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7608281
9 August 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7529388
28 June 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7484873
23 November 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7355425
25 May 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7206059
16 February 2021
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139188
23 April 2020
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6949581
20 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6819691
3 July 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725556
13 February 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6624943
13 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6442931
15 February 2017
Administrative Inspection · Examination of Repairs · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6097761
17 May 2016
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5873323
8 March 2016
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5829017
3 May 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4293822
3 March 2009
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3437533
7 February 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3414802
14 September 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3325845
3 April 2008
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3176835
5 October 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3109335
5 April 2007
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2902098
7 March 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2884752
3 March 2006
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2595192
26 November 2005
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2541872
30 March 2005
Simplified Stability Test · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2310322
9 March 2005
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2309706
21 July 2004
Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 2141577
20 June 2004
Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 2105143
20 April 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2048470
11 February 2003
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1743069
6 February 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1740729
15 January 2002
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1478595
8 November 2001
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075702
8 February 2001
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1395615
11 January 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1395333
8 February 1999
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1473039
16 December 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421589
16 December 1997
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1118248
11 October 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 120130
19 June 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 137492
26 February 1997
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1102995
5 February 1997
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1101976
24 December 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1093666
16 April 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082024
29 January 1996
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1191923
16 January 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 877591
22 October 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 109432
1 September 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 89641
19 April 1995
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 906126
4 January 1995
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 858353
4 March 1994
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1165254
28 September 1993
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1154013
24 March 1993
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 836589
17 March 1992
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 960890
26 February 1992
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1316963
13 March 1991
Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1224410
24 May 1990
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1220118
24 April 1990
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 918659
7 March 1990
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1221306
10 March 1989
Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 898819
1 July 1988
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 896786
26 May 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1195084
12 May 1988
Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1196053
7 March 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1033306
28 April 1987
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1334628
2 April 1987
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1334624
18 June 1986
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 996715
4 April 1986
COI Inspection
Physical examination · THE UNKNOWN UNIT · Activity 998547
6 February 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292528
21 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978887
21 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286716
20 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282388
23 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271278
23 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965423
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2024
Resolved
VSL MUST BE IN FULL COMPLIANCE WITH THE COI WHEN ANY PASSENGERS ARE ABOARD DURING THE TENURE OF THE CERTIFICATE. WHILE ON CHARTER VSL REPORTED STBD MD BECAME INOP, LEAVING ONE OPERABLE MDE. VSL MUST PROVIDE PROPULSION IAW APPROVED PLANS IN ORDER TO MEET THE REQUIREMENTS OF THE COI.
VSL MUST DEMONSTRATE AHEAD AND ASTERN OPERATION OF BOTH MAIN PROPULSION ENGINES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 176.100(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2024
Resolution: Inspected repair of STBD MDE all SAT
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 May 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Marine radio operator certificate not on-board during the inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 23 May 2024
Resolution: Radio Operator permit is now onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. The original tape on the life ring buoy is peeling off and weathered. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Retro-reflective tape was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of lifesaving equipment. Upper life float has minor tears and must be repaired IAW manufacture instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Upper lifefloat repaired IAW manufacture procedures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions. The port engine thermo couple wire has some missing insulation. Renew in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Couple wire was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2024
Resolved
or a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to—(1) Training in the use and location of firefighting equipment and general firefighting knowledge, including:(i) Location of firefighting appliances. Vessel must post a diagram/list of the locations and names of smoke detectors in the pilot house.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Diagram for smoke detection posted in the pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had two different types of life jacket types with only one set of instructions. Provide proof of posted additional life jacket instructions to attending MI. 46CFR185.515(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: Master provided appropriate life jacket donning instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 1 May 2023
Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Vessel was missing tag. Provide proof that float free link has the correct certificate/tag to the attending MI. 46CFR160.073-20(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2023
Resolution: Weak link and painter were provided in an approved arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump and is permanently mounted. Bilge pumps must be permanently mounted in the spaces to the satisfaction of the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: All submersible pumps are properly mounted in the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed so that a person will not accidentally contact energized parts. Install cover/door on breaker panel in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Hinged door installed to prevent accidental contact with energized parts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022
Resolved
Each ring life buoy on a vessel must be orange in color on a vessel with ocean route. Replace forward ring buoy with in-kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Forward life ring buoy was renewed and properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2022
Resolved
Inspection of each portable fire extinguisher to check general condition. MI discovered an improper extinguisher installed in accommodation space. Install 2A extinguisher IAW valid COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 14 July 2022
Resolution: UL rated 2A portable fire extinguisher installed in the accommodation space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022
Resolved
Each small battery installation must be protected from falling objects. Secure cover on battery box in STBD engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Battery box cover was secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Vessel had wasted life jackets and is limited to 35 adult passengers, until full compliment of 44 is replaced in-kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2021
Resolved 7 June 2021
Resolution: The wasted life jackets were replaced in-kind and properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Remark life jacket stowage location and properly mark quanity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: The life jackets stowage was properly marked to the satisfaction of the attending inspector.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 May 2021
Resolved
Replace wasted hose on MSD tank.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: The hose was replaced in-kind to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 3 July 2019
Resolved
The vessel was missing one fire bucket properly marked and the required line attached.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: one bucket added and properly marked with line
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 3 July 2019
Resolved
The junction box disconnect for the crews berthing freeze is wasted and damaged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: New in kind electrical box installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019
Resolved
Several life jackets onboard had mold and required cleaning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: Life jackets cleaned
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2019
Resolved
The crews berthing overhead light fixture is damaged and is missing the lens.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: New lens installed
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 June 2018
Resolved
03 Adult life jackets were id'd as unservice this date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 13 June 2018
Resolved
Supply hose was damaged on the fuel pump on SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2018
Resolved
Stbd VHF antenna mount and whip is damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 14 June 2017
Resolved
Bilge pump not taking suction
Action required: 705 - Other - as specified
Resolved 19 June 2017
Resolution: Pump seal bad, replaced pump all test SAT
Stability › Weathertight Integrity › General
Issued 14 June 2017
Resolved
Aft door to pax compartment missing dog
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Dog installed all SAT
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 June 2017
Resolved
Shower hose ran through the vent damper.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2017
Resolution: Removed shower lines from fire damper all SAT
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 14 June 2017
Resolved
sewage vent fitting at tank broken off
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: replaced fitting all SAT
Accommodation/Occupational Safety › Potable Water System › General
Issued 14 June 2017
Resolved
loose hose clamp
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: replaced hose clamp
Communications › Public Address System › Announcing Station
Issued 14 June 2017
Resolved
PA not working due to new head install
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Wired PA to second head all SAT
Engineering › Steering Gear System › Trunnion Block
Issued 14 June 2017
Resolved
Steering block leak
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Hose removed and refitted to block all SAT.
Stability › Weathertight Integrity › General
Issued 14 June 2017
Resolved
STBD eng hatch missing nut to hinge
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: New nylon nut installed all SAT
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 May 2016
Resolved
Alco sensors were expired, corrected on site.
Due 3 June 2016
Resolved 27 May 2016
Resolution: Corrected immediately.
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2016
Resolved
A 2x2 ft. insert is required in the hull in steering space where a hairline fracture has cracked the hull plating near an existing repair. noted 27 Feb 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2016
Resolved 8 March 2016
Resolution: Insert in place and tested. all satisfactory. Corrected 7 Mar 16.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 March 2009
Resolved
Prove sat emergency drills to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 25 May 2010
Personnel › Training › First Aid/CPR
Issued 3 April 2008
Resolved
All personnel had recently completed CPR/First Aid training on 3/26/08 and have not received cards yet. Owner will fax copies when they receive.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 5 April 2008
Resolution: Received fax with copies of First Aid/CPR cards for three licensed masters.
Engineering › Bilge Water Management System › Piping
Issued 5 April 2007
Resolved
Remove PVC piping on bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 13 April 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 5 April 2007
Resolved
Replace wasted line around the Life Float and sea painter line.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 13 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 April 2007
Resolved
Replace 14 adult life jackets and 4 Child jackets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 13 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 April 2007
Resolved
Replace the Retro on 3 Adult life jackets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 13 April 2007
Construction/Loadline
Issued 5 February 1997
Resolved
REPAIR FRACTURES IN WAY OF AFTER STEERING COMPARTMENT LOCATED AT THE FOLLOWING LOCATIONS; S/S 2ND FRAME BAY FROM STERN/1ST LONG FROM SHEER, 5TH FRAME BAY ON STERN FROM P/S.
Condition: Unknown
Due 26 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 5 February 1997
Resolved
REPAIR FRACTURES IN WAY OF COMPRESSOR COMPARTMENT LOCATED AT THE FOLLOWING LOCATIONS; S/S 4TH FRM BAY FROM FWD/2ND LONG FROM SHEER, S/S 4TH FRM FROM FWD AT CHINE, S/S 5TH FRM FROM FWD/3RD LONG FROM SHEER.
Condition: Unknown
Due 26 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 5 February 1997
Resolved
REPAIR FRACTURES LOCATED IN WAY OF FOREPEAK AT THE FOLLOWING LOCATIONS; S/S2ND FRM FROM BOW AT DECK, S/S 2ND FRM FROM BOW/2ND LONG.
Condition: Unknown
Due 26 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 24 December 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, MAKE PERMANENT REPAIR TO FRACTURE LOCATED IN WAY OF PORT SIDE KEEL COOLER. REPAIRS TO BE MADE TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 24 December 1996
Resolved 24 December 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPAIR INTERNAL DECK SUPPORT BRACKET WHERE FRACTURED, LOCATED IN MSD COMPARTMENT.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Lifesaving
Issued 29 January 1996
Resolved
PROVIDE THREE ADDITIONAL TYPE I ADULT PFD'S. UNTIL SUCH TIME, VESSEL MAY NOT CARRY MORE THAN A TOTAL OF 48 PERSONS.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPAIR FRACTURES (TOTAL OF 2) LOCATED IN AFT STEERING COMPARTMENT ON STBD SIDE, WHERE MARKED.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPAIR FRACTURES (TOTAL OF 2) LOCATED ON STBD MAIN ENGINE BED SUPPORTS.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPAIR MSD THRU-HULL, WHERE WASTED.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 16 January 1996
Resolved
PRIOR TO VESSEL OPERATING WITH PASSENGERS, MAKE PERMANENT REPAIRS TO HULL DAMAGE (WHERE TEMP REPAIRS EXIST) IN WAY OF P/S KEEL COOLER, WHERE FRACTURED. REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 4 January 1995
Resolved
PROVIDE SUCTION HOSE FOR EMERGENCY HAND FIRE PUMP SO IT CAN BE OPERATED FROM THE MAIN DECK IAW 46 CFR 181.10-5.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 4 January 1995
Resolved
PROVIDE NEW LENSES FOR BOTH PORT AND STARBOARD RUNNING LIGHTS TO BRING INTOCOMPLIANCE WITH COLREGS.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Construction/Loadline
Issued 4 January 1995
Resolved
PROVIDE GUARD FOR BELT DRIVEN BILGE PUMP ON STARBOARD ENGINE IAW 46 CFR 177.35-15.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 4 January 1995
Resolved
PROVIDE THREE TYPE 1, ADULT PFDs IAW 46 CFR 180.25-5
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 26 February 1992
Resolved
PROVIDE A COAST GUARD APPROVED CATEGORY I EPIRB ON BOARD THE VESSEL NO LATER THAN 01JAN93.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Deck/Cargo
Issued 10 March 1989
Resolved
RENEW FLAME SCREEN ON THE FUEL TANK VENT.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
PROVIDE ONE ADDITIONAL CHILDRENS PFD PROPERLY EQUIPPED.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
LABEL ALL LIFE JACKET STOWAGE.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Construction/Loadline
Issued 10 March 1989
Resolved
REWELD FRACTURE ON THE STBD MAIN ENGINE MOUNT AFT INBOARD SIDE.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Engineering
Issued 12 May 1988
Resolved
RENEW BILGE SUCTION LINE TO LAZARETTE WITH RIGID PIPE.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Fire Fighting
Issued 28 April 1987
Resolved
HAVE ALL B-II FIRE EXTINGUISHERS HYDROSTATICALLY TESTED
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987
Resolved
REPLACE QUARTZ LIGHT FIXTURE AT AFT STEERING STATION WITH AN APPROVED MARINE TYPE FIXTURE.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Lifesaving
Issued 28 April 1987
Resolved
REPAIR OR RENEW WATERLIGHT ON RING LIFEBOUY.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Engineering
Issued 4 April 1986
Resolved
PROVIDE LAGGING FOR MUFFLERS ON MAIN ENGINES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986