Records from 2005 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 23
11 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8381109
4 April 2025
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8104943
13 February 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8077136
20 July 2024
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7962845
9 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7909100
12 July 2023
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7858564
1 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7678538
14 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7637010
4 January 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7617002
8 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7608281
9 August 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7529388
28 June 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7484873
23 November 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7355425
25 May 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7206059
16 February 2021
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139188
23 April 2020
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6949581
20 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6819691
3 July 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725556
13 February 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6624943
13 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6442931
15 February 2017
Administrative Inspection · Examination of Repairs · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6097761
17 May 2016
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5873323
8 March 2016
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5829017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2024
Resolved
VSL MUST BE IN FULL COMPLIANCE WITH THE COI WHEN ANY PASSENGERS ARE ABOARD DURING THE TENURE OF THE CERTIFICATE. WHILE ON CHARTER VSL REPORTED STBD MD BECAME INOP, LEAVING ONE OPERABLE MDE. VSL MUST PROVIDE PROPULSION IAW APPROVED PLANS IN ORDER TO MEET THE REQUIREMENTS OF THE COI.
VSL MUST DEMONSTRATE AHEAD AND ASTERN OPERATION OF BOTH MAIN PROPULSION ENGINES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 176.100(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2024
Resolution: Inspected repair of STBD MDE all SAT
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 May 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Marine radio operator certificate not on-board during the inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 23 May 2024
Resolution: Radio Operator permit is now onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. The original tape on the life ring buoy is peeling off and weathered. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Retro-reflective tape was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of lifesaving equipment. Upper life float has minor tears and must be repaired IAW manufacture instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Upper lifefloat repaired IAW manufacture procedures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions. The port engine thermo couple wire has some missing insulation. Renew in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Couple wire was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2024
Resolved
or a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to—(1) Training in the use and location of firefighting equipment and general firefighting knowledge, including:(i) Location of firefighting appliances. Vessel must post a diagram/list of the locations and names of smoke detectors in the pilot house.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Diagram for smoke detection posted in the pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had two different types of life jacket types with only one set of instructions. Provide proof of posted additional life jacket instructions to attending MI. 46CFR185.515(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: Master provided appropriate life jacket donning instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 1 May 2023
Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Vessel was missing tag. Provide proof that float free link has the correct certificate/tag to the attending MI. 46CFR160.073-20(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2023
Resolution: Weak link and painter were provided in an approved arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump and is permanently mounted. Bilge pumps must be permanently mounted in the spaces to the satisfaction of the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: All submersible pumps are properly mounted in the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed so that a person will not accidentally contact energized parts. Install cover/door on breaker panel in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Hinged door installed to prevent accidental contact with energized parts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022
Resolved
Each ring life buoy on a vessel must be orange in color on a vessel with ocean route. Replace forward ring buoy with in-kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Forward life ring buoy was renewed and properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2022
Resolved
Inspection of each portable fire extinguisher to check general condition. MI discovered an improper extinguisher installed in accommodation space. Install 2A extinguisher IAW valid COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 14 July 2022
Resolution: UL rated 2A portable fire extinguisher installed in the accommodation space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022
Resolved
Each small battery installation must be protected from falling objects. Secure cover on battery box in STBD engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 July 2022
Resolution: Battery box cover was secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Vessel had wasted life jackets and is limited to 35 adult passengers, until full compliment of 44 is replaced in-kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2021
Resolved 7 June 2021
Resolution: The wasted life jackets were replaced in-kind and properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Remark life jacket stowage location and properly mark quanity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: The life jackets stowage was properly marked to the satisfaction of the attending inspector.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 May 2021
Resolved
Replace wasted hose on MSD tank.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: The hose was replaced in-kind to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 3 July 2019
Resolved
The vessel was missing one fire bucket properly marked and the required line attached.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: one bucket added and properly marked with line
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 3 July 2019
Resolved
The junction box disconnect for the crews berthing freeze is wasted and damaged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: New in kind electrical box installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019
Resolved
Several life jackets onboard had mold and required cleaning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: Life jackets cleaned
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2019
Resolved
The crews berthing overhead light fixture is damaged and is missing the lens.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 20 September 2019
Resolution: New lens installed
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 June 2018
Resolved
03 Adult life jackets were id'd as unservice this date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 13 June 2018
Resolved
Supply hose was damaged on the fuel pump on SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2018
Resolved
Stbd VHF antenna mount and whip is damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 22 June 2018
Resolution: Completed and found satisfactory to the marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 14 June 2017
Resolved
Bilge pump not taking suction
Action required: 705 - Other - as specified
Resolved 19 June 2017
Resolution: Pump seal bad, replaced pump all test SAT
Stability › Weathertight Integrity › General
Issued 14 June 2017
Resolved
Aft door to pax compartment missing dog
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Dog installed all SAT
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 June 2017
Resolved
Shower hose ran through the vent damper.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2017
Resolution: Removed shower lines from fire damper all SAT
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 14 June 2017
Resolved
sewage vent fitting at tank broken off
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: replaced fitting all SAT
Accommodation/Occupational Safety › Potable Water System › General
Issued 14 June 2017
Resolved
loose hose clamp
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: replaced hose clamp
Communications › Public Address System › Announcing Station
Issued 14 June 2017
Resolved
PA not working due to new head install
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Wired PA to second head all SAT
Engineering › Steering Gear System › Trunnion Block
Issued 14 June 2017
Resolved
Steering block leak
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: Hose removed and refitted to block all SAT.
Stability › Weathertight Integrity › General
Issued 14 June 2017
Resolved
STBD eng hatch missing nut to hinge
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 19 June 2017
Resolution: New nylon nut installed all SAT
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 May 2016
Resolved
Alco sensors were expired, corrected on site.
Due 3 June 2016
Resolved 27 May 2016
Resolution: Corrected immediately.
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2016
Resolved
A 2x2 ft. insert is required in the hull in steering space where a hairline fracture has cracked the hull plating near an existing repair. noted 27 Feb 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2016
Resolved 8 March 2016
Resolution: Insert in place and tested. all satisfactory. Corrected 7 Mar 16.