JOSE BREEZE is a 1982 tank ship. The Coast Guard has recorded 47 inspections since 2003, most recently in March 2009, along with 29 deficiencies and 16 operational controls.

Records from 2003 to 2009. Most recent: operational control imposed, 3 March 2009.

Built
1982
Last inspected
3 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8125739 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
JAPAN
—
Maury page id
psix-53927

Inspections, by type

…with no type recorded22
Years with a record 7 calendar years (2003–2009)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9087 - Convention (Subpart B), Gross Ton
9087 - Simplified, Gross Ton
5649 - Simplified, Net Ton
5649 - Convention (Subpart B), Net Ton
16177 - Dead Weight, Ton
20444 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 47

3 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427011
1 March 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3425918
16 February 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3416951
16 February 2009 ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3418695
13 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3393381
3 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356564
13 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3343824
20 July 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3273366
4 April 2008 ISPS III Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3173202
10 March 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3161460
6 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3159585
6 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3161492
7 February 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3143742
3 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3141107
4 October 2007 MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3067457
23 March 2007 ISPS III Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2897041
22 March 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2892649
16 October 2006 ISPS III Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2800888
22 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2657019
18 May 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2652499
17 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2652176
21 April 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2630291
27 March 2006 MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · COC-CHEM Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2609767
25 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2609632
21 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2521797
28 April 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2344948
27 April 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2383573
27 April 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2567711
8 March 2005 Ballast Water Examination · Deficiency Check · ISPS III Exam · COC-CHEM Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2303399
2 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2302325
16 December 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2260855
15 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2270512
7 December 2004 Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2254655
5 July 2004 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2120999
4 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2124928
8 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2070449
11 March 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2022653
16 February 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2006670
27 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1996130
21 November 2003 MARPOL Annex I Examination · Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1952238
11 August 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1873808
11 August 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1876355
23 April 2003 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1779252
29 March 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1764941
20 February 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1746876
6 February 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1741411
29 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1737810

Deficiency record · 29

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 16 February 2009 Resolved
No.1 cargo line worn. Cargo manifold valve worn and leaking at the flange (wasted gasket). Repair leaking cargo line to the satisfaction of class. SOLAS I/11
Due 17 March 2009
Resolved 22 October 2009
Resolution: valve replaced and tested cleared by class
Construction/Loadline › Structures › Door
Issued 16 February 2009 Resolved
Latching mechanism for dog on steering room hatch in way of stern on portside wasted and bent. Hatch cover is warped (bowing) and failed the chalk test. Repair to original. ICLL 66
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 30 October 2009
Resolution: replaced cleared by class
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 February 2009 Resolved
Emergency lighting for the portside embarkation station has wasted support being temporarily repaired with electrical tape. Repair to original. SOLAS I/11
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 30 October 2009
Resolution: was replaced and cleared by class
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 16 February 2009 Resolved
Vsl's posted fire control plan does not note (#1) paint locker location or sprinkler system therein and (#2) the semi-portable fire extinguisher in way of engine control room. Correct to satsfaction of class. SOLAS I/11
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 30 October 2009
Resolution: paint locker removed and placed in new location annotation made on fire plan and approved by flag
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 February 2009 Resolved
Portable plastic fan (i.e. house fan) being used for ventilation in space behind the engine control room. This is not an approved installation and is mounted with duct tape in a bulkhead opening. Potential fire hazard. Class is to address this installation. SOLAS I/11
Action required: 705 - Other - as specified
Due 17 March 2009
Resolved 30 October 2009
Resolution: fan was removed and proper ventilation was provided approved by class
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 10 March 2008 Resolved
On March 06, 2008, the vessel lost its port anchor at mm 117 Lower Mississippi River. SECNOLA issued COTP Order 0256-08 and restricted the vessel to IMTT St. Rose mm 118 Lower Mississippi River. See Operational Control Activity # 3159585
Action required: 705 - Other - as specified
Due 10 March 2008
Resolved 10 March 2008
Resolution: PSC NOLA/ Arrivals received a class report from Nippon [name withheld] attesting to the satisfactory reattachment of the vessel’s port anchor.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 October 2006 Resolved
The stern tube sea water cooling pipe has a temporary patch. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2006
Resolved 11 November 2006
Resolution: PSC Nola received class report from Nippon Kaiji Kyokai satisfying requirement.
Fire Fighting › Fire Main › Condition
Issued 16 October 2006 Resolved
The emergency fire pump suction pipe located above the sea chest has a temporary repair in the middle of the elbow which is leaking.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2006
Resolved 11 November 2006
Resolution: PSC Nola received class report from Nippon Kaiji Kyokai satisfying requirement.
Engineering › Freshwater Generation System › Piping
Issued 16 October 2006 Resolved
The fresh water pipe to the purifier operating water tank has a temporary patch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2006
Resolved 11 November 2006
Resolution: PSC Nola received class report from Nippon Kaiji Kyokai satisfying requirement.
Navigation › Piloting/Steering › Gyro Compass
Issued 26 March 2006 Resolved
Vessel was granted a deviation to enter port with an inoperable gyrocompass. Gyrocompass must be repaired prior to departure from port. To the satisfaction of Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Received proper documentation from Mackay Marine satisfying requirement.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 26 March 2006 Resolved
The No. 1 steering gear pump does not have a protective cover over the rotating shaft while pump is in operation. Install protective cover to the satisfaction of class.
Action required: 705 - Other - as specified
Due 3 April 2006
Resolved 21 April 2006
Resolution: Received class report from NKK satisfying requirement.
Lifesaving › Launching Appliances › Davit
Issued 7 December 2004 Resolved
Make repairs to port and starboard life boat falls drum. To the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Received class report attesting to satisfactory repairs.
Lifesaving › Launching Appliances › Davit
Issued 7 December 2004 Resolved
Make repairs to port forward and starboard aft lifeboat davit sheave bracket. To the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Received class report attesting to satisfactory repairs.
Lifesaving › Lifeboat Equipment › Tools (engine)
Issued 7 December 2004 Resolved
Renew port lifeboat engine raw water suction hose. To the satisfaction of classification society.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 December 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 December 2004 Resolved
Renew port anchor chain locker deck in the vicinity of the post. To the satisfaction of classification society.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2005
Resolution: Received class report attesting to satisfactory repairs.
Stability › Watertight Integrity › General
Issued 7 December 2004 Resolved
Renewenfine control room window. To the satisfaction of classification society.
Action required: 15 - Rectify deficiencies by next port
Due 16 December 2004
Resolved 16 December 2004
Lifesaving › Launching Appliances › Padeye
Issued 7 December 2004 Resolved
Renew port lifeboat pendant line shackle. To the satisfaction of classificatin.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 December 2004
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 7 December 2004 Resolved
Update SMS reports of deficiencies. To the satisfaction of classification.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 December 2004
Fire Fighting › Fixed Deck Foam System
Issued 16 February 2004 Resolved
The piping that connects the fire main to the foam monitor on the foam monitor located port side directly over the manifold has an approximately 3" hole. The system provided adequate pressure with hole in piping. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 11 March 2004
Resolution: Received report from class.
Documentation › Safety/Response Plans/Programs
Issued 16 February 2004 Resolved
The fire control plan does not indicate the location of the fire lockers, portable foam applicators, and hose reels. Update fire control plan. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 11 March 2004
Resolution: Received report from class.
Fire Fighting › Fire Pumps
Issued 6 February 2003 Resolved
The water cooling line for the emergency fire pump is temporarily patched and leaking. LEGACY COMPONENT DESC: Water Cooling Line
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 14 February 2003
Resolution: received class report from NKK stating that the cooling water line was permanently repaired with new fittings.
Fire Fighting › Fire Pumps
Issued 6 February 2003 Resolved
The fuel filter and supply pipe for the emergency fire pump is temporarily patched and leaking. NKK assigned a condition of class to be rectified prior to 12MAR03. LEGACY COMPONENT DESC: Fuel Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 21 April 2003
Resolution: Recieved class report stating fuel filter and supply pipe for the emergency fire pump has been repaired to their satisfaction.
Fire Fighting › Fixed Deck Foam System
Issued 6 February 2003 Resolved
The cargo deck foam piping system is temporarily patched in the vicinity of No. 3 center butterworth opening. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 14 February 2003
Resolution: Received class report from NKK stating that the deck foam piping was permanently repaired by crop and renewal of approximately 6.5 meters length in way of No. 3 COT.
Fire Fighting › Fixed Deck Foam System
Issued 6 February 2003 Resolved
No. 5 foam monitor will not provide an effective stream. LEGACY COMPONENT DESC: Monitors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 14 February 2003
Resolution: Received class report from NKK stating that the No. 5 foam monitor was dismantled and overhauled. Tested satisfactory.
Fire Fighting › Portable Foam Applicators
Issued 6 February 2003 Resolved
The vessel has no portable foam applicators in accordance with BCH code 3.14.9. Provide applicators to the satisfaction of class prior to 08 Feb 03. The applicators were not available in New Orleans. NKK assigned a condition of class to be rectified by 12 Mar 2003.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 21 April 2003
Documentation › Certificates/Documents
Issued 6 February 2003 Resolved
The vessel does not meet the IBC requirements to carry 1,1-Dichloroethane. Provide class approval prior to carrying this cargo or eliminate cargo from Certificate of Fitness. LEGACY COMPONENT DESC: Certificate of Fitness (BCH Code)
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 14 February 2003
Resolution: 1, 1-Dichloroethane was deleted from the Certificate of Fitness by NKK.
Engineering › Sea-water System (primary cooling)
Issued 6 February 2003 Resolved
The sea water cooling pipe to the stern tube cooler is temporarily patched and leaking from the spool piece. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 14 February 2003
Resolution: Recieved class report from NKK stating that the stern tube inboard/ER seal (EVK), cooling water line was permanently repaired with new fittings; seal was fitted with inflatable bladder allowing repairs in afloat condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2003 Resolved
Class must attest to the integrity of the non-conducting matting in the front of the main switchboard prior to 08 Feb 03. LEGACY COMPONENT DESC: Non-conducting matting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2003
Resolved 10 February 2003
Resolution: Received class report from NKK satisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 February 2003 Resolved
The suction pressure sensor for the No. 2 main cargo line is broken. Received class report from NKK attesting to the temporary repairs. NKK assigned a condition of class to be rectified permanently prior to 12MAR03. LEGACY COMPONENT DESC: Suction Pressure sensor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 21 April 2003
Resolution: Recieved class report stating pressure sensor for the #2 main cargo line has been replaced and tested to the satisfaction of class.

Ownership record