PEARL

PEARL is a 1982 offshore supply vessel. The Coast Guard has recorded 69 inspections since 1982, most recently in September 2019, along with 76 deficiencies and 1 operational control.

Records from 1982 to 2019. Most recent: inspection, 9 September 2019.

Built
1982
Last inspected
9 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8123494 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD3217
Flag
UNITED STATES
338117000, 366915240, 367127440 (licence lapsed)
Maury page id
psix-53928

Inspections, by type

…with no type recorded8
Years with a record 35 calendar years (1982–2019)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it624 - Convention (Subpart B), Gross Ton
187 - Convention (Subpart B), Net Ton
262 - Regulatory (Subpart C or D), Gross Ton
178 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDI6913MMSI 367127440 · expired · compulsorily equipped · granted 25 March 2016, cancelled 30 May 2026
WDD3217MMSI 367127440 · cancelled · compulsorily equipped · granted 1 July 2006, cancelled 22 March 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDB5934MMSI 366915240 · cancelled · compulsorily equipped · granted 5 December 2003, cancelled 20 June 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCV5653MMSI 338117000 · cancelled · compulsorily equipped · granted 29 October 1998, cancelled 25 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

9 September 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6811151
17 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6719422
16 July 2018 MTSA Verification · Examination of Repairs · In-Service Inspection · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6481575
14 March 2018 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6371848
23 January 2018 Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6340054
26 July 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6221349
18 July 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5944975
15 October 2015 In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5743811
28 September 2015 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5731016
27 July 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4389421
28 July 2011 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4101000
9 September 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3845975
13 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3526068
29 July 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3268970
7 March 2008 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3166341
11 December 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3112710
28 November 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3105916
17 September 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3057633
19 July 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993619
14 September 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2769597
7 August 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2720644
18 July 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2716674
21 June 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2686901
24 May 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2657647
13 September 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491673
10 August 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2452766
2 May 2005 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2342361
2 May 2005 MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2347813
28 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2300617
21 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2278727
24 October 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2226919
24 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2204195
9 August 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2161266
20 July 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2139612
29 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2115353
27 May 2004 Administrative Inspection · In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079579
19 February 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2009494
31 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2005476
28 July 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1859304
3 January 2003 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1725435
14 November 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1704468
22 October 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075416
24 May 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1065647
2 May 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467211
17 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045757
14 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388705
5 January 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1120826
18 November 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364456
18 November 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451127
18 January 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383130
18 January 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175677
21 November 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435556
18 January 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448503
19 January 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448413
22 January 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264825
6 November 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1311530
26 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911335
16 May 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900189
9 February 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1232308
26 January 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1223698
16 February 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195258
26 January 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1326820
5 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315819
27 January 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993648
28 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1292337
5 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979513
31 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1288285
2 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975693
23 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963310

Deficiency record · 76

04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 June 2019 Resolved
Prove proper operation of the bilge pumping arrangements. 46 CFR 128.440
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2019 Resolved
Prove enrollment in DAPI consortium. 46 CFR 16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2019
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 17 June 2019 Resolved
Remove corroded LPG cylinder from ship.
Action required: 705 - Other - as specified
Due 24 June 2019
Resolved 18 June 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 June 2019 Resolved
Install strainer at bilge suction point at Aft passageway and bow prop compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2019
Resolution: Pictures received, def cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 16 July 2018 Resolved
Mount laundry appliances to prevent shifting at sea.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 July 2018
Resolution: Appliances strapped down.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 July 2018 Resolved
Seal cable penitration aft of bridge.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 25 July 2018
Resolution: Penetration sealed with caulking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2018 Resolved
Replace expired light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 July 2018
Resolution: Replaced light.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 16 July 2018 Resolved
Repair broken refer gasket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 July 2018
Resolution: Gasket sealed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 March 2018 Resolved
No proof of MIS submitions after 2011.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 19 March 2018
Resolution: Received a consortium enrollement letter attensting to Random Selection Services (RSS) for drug and alcohol testing for Teekay Marine Solutions, Inc that comply with Federal and Department of Transportation procedures for transportation workplace drug and
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 14 March 2018 Resolved
Random vessel selection is not conducted by a scientifically valid method. The vessel to be tested is pulled from a list of one vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 19 March 2018
Resolution: Received a consortium enrollement letter attensting to Random Selection Services (RSS) for drug and alcohol testing for Teekay Marine Solutions, Inc that comply with Federal and Department of Transportation procedures for transportation workplace drug and
Construction/Loadline › Markings › Load Line Mark
Issued 18 July 2016 Resolved
Paint deck line a contrasting color
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 4 August 2016
Resolution: Deck line now painted a contrasting color.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 18 July 2016 Resolved
Ensure all manuals are ship specific
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 12 September 2016
Resolution: Attended vessel, all manuals and certs are ship specific
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 18 July 2016 Resolved
Prove proper operation of rudder angle indicator on bridge in relation to actual position of rudder
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 12 September 2016
Resolution: Attended vessel, RAI now operable and accurate.
Engineering › Steering Gear System › Rudder
Issued 18 July 2016 Resolved
Prove proper operation of emergency steering IAW provided instructions.
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 4 August 2016
Resolution: Emergency steering now functions properly IAW instructions.
Engineering › Compressed Air System (start air) › Valve
Issued 27 July 2012 Resolved
Replace Starboard Relief valve on Air Receiver, prior to using
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Starboard relief valve was replaced and tested satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 27 July 2012 Resolved
Replace Starboard Jacket Water Gauge on MDE
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Starboard Jacket water gauge was replaced and tested satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 27 July 2012 Resolved
Replace port MDE High temp Sensor
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Port MDE High water Temp Sensor was replaced and tested satisfactory.
Fire Fighting › Ventilation Systems › Ducts
Issued 27 July 2012 Resolved
Replace ventilation ducting near control area due to holes in duct work
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Ventilation was renewed and inspected satisfactory.
Engineering › Steering Gear System › Ram
Issued 28 July 2011 Resolved
Make proper adjustments to steering gear to prevent rudder from reaching the port stop. This allignment must be sycronized with the rudder stock or gear and must work with the limit switch.
Condition: Improper Installation
Due 28 July 2012
Resolved 2 August 2012
Resolution: Made proper adjustments to steering gear to prevent rudder from reaching the port stop.
Engineering › Lubricating Oil Service System › Gauge
Issued 28 July 2011 Resolved
Replace oil & tachometer gauges for # 2 SSDG.
Condition: Improper/Lack of Maintenance
Due 28 July 2011
Resolved 2 August 2011
Resolution: Replaced oil & tachometer gauges for # 2 SSDG.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 13 July 2009 Resolved
Demonstrate low lube oil pressure shut-down on vessel's port generator IAW 46 CFR 111.12-1(c).
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2009 Resolved
Provide RPM gauge for starboard generator IAW 46 CFR 58.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Resolution: Observed new gauge installed & operating properly.
Lifesaving › Lifebuoys › Serviceable
Issued 13 July 2009 Resolved
Replace retroreflective tape on vessel's 06 ring lifebuoys IAW 46 cfr 108.649.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Fire Fighting › Ventilation Systems › Fans
Issued 13 July 2009 Resolved
Make engine room port side vent/blower system operational IAW 46 CFR 90.20-1 & 46 CFR 58.01-45.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2009 Resolved
Replace cracked globe on deck light on 01 Deck IAW 46 CFR 111.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Electrical › Electrical Distribution System (service) › Cable
Issued 13 July 2009 Resolved
Replace/repair chafed cable to light (main deck aft of house) IAW 46 CFR 111.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Resolution: Cable replaced in-kind w/ new; installed properly.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 13 July 2009 Resolved
Provide copy of latest crane load test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Resolution: Verified new ICGB certificate on-board; crane lifting capacity limited to 2104 lbs as per SWL of cable & proof test conducted by ICGB surveyor.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 19 July 2007 Resolved
Repair the lighting receptacle with the broken off incadacent light bulb in the steering gear compartment on the starboard side aft.
Due 2 August 2007
Resolved 20 July 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 July 2007 Resolved
Complete annual machinery testing as per the vessel's approved "Periodic Automation Test Procedure".
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 2 August 2007
Resolution: Tests conducted by third party and documentation provided.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 July 2007 Resolved
Repair fuel leak from the #3S double bottom fuel tank side hatch to the bilges in the engine room passageway "tunnel". Ensure all diesel fuel is cleaned from the bilge after the fuel leak is repaired.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2007
Resolved 2 August 2007
Resolution: tank hatch tightened and leak stopped.
Electrical › Lighting (service) › Outlet Box
Issued 19 July 2007 Resolved
Repair incadacent light in the steering compartment, starboard side aft, with the broken off light bulb.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 2 August 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 19 July 2007 Resolved
Prove proper operation of port main diesel engine emergency shutdown.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Repaired and tested, witnessed by [name withheld].
Engineering › Diesel Engine (auxiliary) › Valve Actuating Gear
Issued 19 July 2007 Resolved
Provide operable high oil temp alarm for the stbd generator.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Provided.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 July 2007 Resolved
Remove excess oil from engineroom bilges, approx 5" deep.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2007 Resolved
Wire welding machine power supply into junction box, currently spliced outside of junction box.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Repaired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 July 2007 Resolved
Provide protective globe for port side light in steering room.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Provided.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 19 July 2007 Resolved
Provide permanent repairs to stbd main engine expansion tank. Currently tank has a cracked nipple on the outboard side.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Repaired.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 July 2007 Resolved
Provide amended automation test procedures for approval, showing set points for all automated machinery.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 13 July 2009
Lifesaving › Line-Throwing Appliances › Lines
Issued 7 August 2006 Resolved
Provide 2 more lines for the line throwing gun.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 September 2006
Resolution: Provided 2 more lines for line throwing gun.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 7 August 2006 Resolved
Provide a BII portable fire extinguisher to replace the discharged BII fire extinguisher in the galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2006
Resolved 7 August 2006
Resolution: Corrected while on board.
Construction/Loadline › Structures › Superstructure
Issued 7 August 2006 Resolved
Service the tonnage openings on the main deck port and starboard by removing and repairing the broken bolts and wasted edges.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Serviced tonnage openings and renewed bolts.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 August 2006 Resolved
Renew gaskets for the engine room trunk vent closures on both port and starboard sides.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Renewed gaskets.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 August 2006 Resolved
Repair broken dogs on port engine room vent closure.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Renewed broken dogs.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 7 August 2006 Resolved
Provide a 30X30 mesh flame screen for the paint locker vent.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed 30x30 mesh flame screen.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 August 2006 Resolved
Provide a gasket for the paint locker top.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed gasket.
Construction/Loadline › Structures › Air Pipe
Issued 7 August 2006 Resolved
Repair the compartment vent gooseneck check valve for the port side aft compartment by installing a missing check valve ball.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Renewed housing and installed check valve ball.
Fire Fighting › Fire Main › Valves
Issued 7 August 2006 Resolved
Provide a handle for the fire plug valve at fire station #5 port side aft.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed new handle.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 August 2006 Resolved
Provide a Vessel Response Plan.
Action required: 705 - Other - as specified
Due 7 August 2007
Resolved 14 September 2006
Resolution: Submitted VRP; provided G-PCV-1 letter stating compliance.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 7 August 2006 Resolved
Repair broken anchor windlass motor coupling.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 September 2006
Resolution: Renewed motor coupling.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 7 August 2006 Resolved
Demonstrate port anchor will lower.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 14 September 2006
Resolution: Demonstrated proper operation of port anchor.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 August 2006 Resolved
Clean lint from dryer vent.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Cleaned dryer vent.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 7 August 2006 Resolved
Demonstrate jacket water alarm system on all diesel engines.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Renewed all jacket water alarms; spot checked for operation.
Electrical › Electric Generation Source (service) › Generator
Issued 7 August 2006 Resolved
Provide a tachometer for the #1 Generator.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed new tachometer.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 August 2006 Resolved
Provide blanks for open circuit breaker places in the galley electrical panel and engine room electrical panels.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed blanks in all panels.
Engineering › Diesel Engine (auxiliary) › Air-flex Clutch
Issued 7 August 2006 Resolved
Remove the disconnected shaft brake mechanism for the bow thruster engine.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Removed shaft brake mechanism.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 August 2006 Resolved
Provide covers on the junction boxes in way of the port and starboard engine room trucks and steering compartment.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Installed covers.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2006 Resolved
Provide globes and guards for the lights over the bow thruster, port engine room trunk and #2 generator.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Provided globes.
Lifesaving › Immersion Suits › Serviceable
Issued 7 August 2006 Resolved
Provide 10 additional survival suits.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2006
Resolved 7 August 2006
Resolution: Corrected while on board.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2005 Resolved
Prove proper operation of engine room automation alarms and set points IAW Automation Test Procedures.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 27 May 2005
Resolution: Proved proper operation of engine room alarms.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 May 2005 Resolved
Renew missing alarm lens located on engine room alarm board.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 27 May 2005
Resolution: Renewed missing alarm lens.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 2 May 2005 Resolved
Prove proper operation of rpm gauge on #1 generator.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 27 May 2005
Resolution: Proved proper operation of RPM gauge on #1 generator.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 2 May 2005 Resolved
Prove proper operation of #1 generator over speed trip.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2005
Resolved 5 May 2005
Resolution: Proved proper operation of #1 generator over speed trip.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 2 May 2005 Resolved
Prove proper operation of fire monitor pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2005
Resolved 5 May 2005
Resolution: Proved proper operation of fire monitor pump.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2005 Resolved
Prove proper operation of main bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2005
Resolved 5 May 2005
Resolution: Proved proper operation of main bilge pump.
Engineering › Bilge Water Management System › Not Operational
Issued 29 June 2004 Resolved
Remove all bilge water from forward passageway and make availiable for re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 19 July 2004
Engineering › Bilge Water Management System › Not Operational
Issued 29 June 2004 Resolved
Remove all bilge water and oil from engineroom and make availiable for re-inspection. Dispose of all oily water IAW any/all local, state, and federal regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 19 July 2004
Engineering › Steering Gear System › Valve, Control
Issued 29 June 2004 Resolved
Install limit switches on steering system IAW 46 CFR 182.610.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 19 July 2004
Resolution: Limit switches adjusted properly
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 14 November 2002 Resolved
SCBA 5-year hydro test expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2002
Resolution: 3rd Party conducts hydro test.
Lifesaving
Issued 18 November 1997 Resolved
PROVIDE LINE FOR LINE THROWING GUN AS REQUIRED IN 46CFR94.45-15(b)(6)(i) or (ii) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Lifesaving
Issued 18 November 1997 Resolved
PROVIDED UPDATED FIRE AND SAFETY PLAN FOR THE VESSEL.
Condition: Unknown
Due 18 December 1997
Resolved 18 November 1997
Engineering
Issued 26 January 1990 Resolved
REPLACE FUEL OIL TANK VENT FLAME SCREENS WITH SCREENS OF THE PROPER MESH SIZE.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Deck/Cargo
Issued 26 January 1990 Resolved
REPAIR/RENEW ONE BULK TANK RELIEF VALVE.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Lifesaving
Issued 5 March 1985 Resolved
SERVICE PORT AND STBD LIFE RAFTS AND PORT AND STBD HYDROSTATIC RELEASES BY 14MAR85.
Condition: Unknown
Due 5 March 1985
Resolved 5 March 1985
Lifesaving
Issued 31 January 1985 Resolved
REINSTALL RESCUE BOAT WINCH.
Condition: Unknown
Due 31 January 1985
Resolved 31 January 1985
Fire Fighting
Issued 31 January 1985 Resolved
PRIOR TO SAILING INSTALL ONE FIRE HOSE ON BOARD.
Condition: Unknown
Due 31 January 1985
Resolved 31 January 1985
Lifesaving
Issued 31 January 1985 Resolved
REPAIR HYDROSTATIC RELEASE ON PORT SIDE PRIOR TO 7FEB85.
Condition: Unknown
Due 31 January 1985
Resolved 31 January 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.