MAURY USCG vessel records Sign in
← All vessels

HOPEFUL HARVEST

HOPEFUL HARVEST is a 1982 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1982, most recently in January 2020, along with 54 deficiencies — 5 with no resolution recorded — and 2 casualty investigations between 2005 and 2008.

Records from 1982 to 2020. Most recent: inspection, 7 January 2020.

Built
1982
Last inspected
7 January 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5197
Flag
UNITED STATES
367154970, 368312420
Maury page id
psix-53931

Inspections, by type

…with no type recorded11
Years with a record 30 calendar years (1982–2020)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)83.5 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE TRAWLERS, INC. · BAYOU LA BATRE, AL, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREEDVILLE, VA
Trade endorsementsFishery
DocumentationValid · issued 25 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN7873MMSI 368312420 · active · compulsorily equipped · granted 6 May 2023, expires 6 May 2033
WDD5197MMSI 367154970 · active · compulsorily equipped · granted 12 October 2016, expires 12 December 2026
WDB8141MMSI 366534000 · expired · compulsorily equipped · granted 3 June 2004, cancelled 9 August 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCX2722MMSI 366746050 · cancelled · compulsorily equipped · granted 23 March 1998, cancelled 6 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

7 January 2020 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6875458
23 October 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6561728
27 September 2017 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6277108
18 July 2017 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6201030
29 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5956974
22 March 2014 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 4821318
1 February 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4235856
7 February 2011 Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3937125
11 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3415940
23 January 2009 Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3397091
2 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3269776
4 February 2008 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3141379
4 February 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3271078
29 January 2008 Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3138646
9 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582442
5 January 2006 Administrative Inspection · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2867106
17 August 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2522055
12 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2472460
1 December 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251101
17 November 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2242748
11 November 2004 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2239346
2 November 2004 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2233116
28 October 2004 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2226124
24 June 2004 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2109266
30 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781429
15 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 151608
20 April 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453471
12 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114219
14 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380788
23 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099908
27 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392414
7 April 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427029
8 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456155
8 April 1993 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376963
13 October 1992 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264220
17 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410724
27 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71275
19 April 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920872
20 April 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216394
10 October 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348069
20 April 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893915
29 April 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043924
24 April 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332170
8 October 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009051
25 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296143
25 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987717
26 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280459
11 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276952
26 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277165
26 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274086

Deficiency record · 54

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 March 2020 No resolution recorded
At each intial and subsequent inspection for certification, the marine inspector shall require that all observed unsafe practices and hazardous conditions be corrected. Both port/stbd generator windings have excess oil on generator windings posing a fire risk. Clean windings and identify source of oil and present findings to attending USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2020 No resolution recorded
MI's observed excessive leak on starboard shaft seal. Make appropriate repairs to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2020 No resolution recorded
MIs observed wastage on hose for portable fire extinguisher that is attached to paint locker. Replace to satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2020 No resolution recorded
Air receiver has a MAWP of 250, relief valve set at 175, but gauge is maxed at 600. Replace gauge with one that is no more than 2 times the setting of the relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 March 2020 No resolution recorded
Excessive wastage on deck fram in way of emergency escape hatch in engine room to main deck. Make repairs at the next scheduled drydock.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 October 2018 Resolved
Straps holding the drop net were torn and rotted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2018
Resolution: 12 person life float replaced with new one.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2018 Resolved
Two electrical cables found in the equipment room were not properly terminated. Terminate properly or remove
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2018
Resolution: Witnessed wires removed and plugged.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2018 Resolved
Found one battery operated emergency light located in crew area below the main deck inoperable. Other working e-lights provided sufficient lighting to not require correction prior to departure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2018
Resolution: Witnessed satisfactory test of the emergency light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 October 2018 Resolved
Found cooling water temp gauge on starboard generator not working. Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2018
Resolution: Observed replaced sensor and operational temp. gauge.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 August 2017 Resolved
Replace corroded CO2 bottles and hoese IAW servicing certificates. OLD T 46 CFR 181.20-30(c)
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 8 September 2017
Resolution: Hoses and bottles were replaced and verified by third party. Received report and added to the activity
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 July 2017 Resolved
Provide sufficient alcohol testing equipment to test entire crew in the event of a casualty.
Action required: 705 - Other - as specified
Due 13 August 2017
Resolved 11 August 2017
Resolution: Alcohol test strips were provided onboard
Communications › Radio Communications › VHF Radiotelephone
Issued 29 July 2016 Resolved
DSC for VHF radio was not installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 4 August 2017
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 29 July 2016 Resolved
Vessel did not have heat detectors installed in main machinery space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2016
Resolved 4 August 2017
Communications › Radio Communications › Satellite Communications Capability
Issued 11 February 2009 Resolved
Vessel did not have NAVTEX installed
Due 13 March 2009
Resolved 18 February 2009
Resolution: NAVTEX installed
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 11 February 2009 Resolved
Vessel has no Rudder Angle Indicator
Due 13 March 2009
Resolved 18 February 2009
Resolution: Rudder Angle Indicator installed
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 11 February 2009 Resolved
Hole in flame screen on fuel vent. Other flame screens on vents needed cleaning.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2009
Resolution: Flame screen was replaced and other flame screens cleaned prior to departure of inspectors
Engineering › Fuel Oil Service System › Filter
Issued 11 February 2009 Resolved
Remove petcock from oil filters
Due 13 March 2009
Resolved 18 February 2009
Resolution: Petcock removed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 February 2009 Resolved
Guard missing on Emergency light
Due 13 March 2009
Resolved 18 February 2009
Resolution: Globe replaced
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 29 January 2008 Resolved
RPM gauges missing, needed to bring into compliance with New T regs.
Condition: Placed in Improper Service
Due 29 February 2008
Resolved 30 January 2008
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 January 2008 Resolved
Provide lifesaving equipment maintenance manual.
Due 29 February 2008
Resolved 30 January 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 29 January 2008 Resolved
Adjust overspeed trips to shut off at 64Hz on both generators
Due 29 February 2008
Resolved 30 January 2008
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 29 January 2008 Resolved
Prove proper operation of remote fuel pump shutoff.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2008 Resolved
Need latch for oven door.
Due 29 February 2008
Resolved 30 January 2008
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 29 January 2008 Resolved
Repair shower in fwd. berthing area. No water flow.
Due 29 February 2008
Resolved 30 January 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 January 2008 Resolved
Change water tight door gaskets from soft to hard material.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 29 January 2008 Resolved
repair pinholes/cracked welds on sweage o/b disc. Small leak found
Due 29 February 2008
Resolved 30 January 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 January 2008 Resolved
Paint draft marks fore and aft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2008
Lifesaving › Lifefloat › Retroreflective Material
Issued 29 January 2008 Resolved
Replace damaged sections of retroreflective tape on top life float and port side life ring.
Due 29 February 2008
Resolved 30 January 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 29 January 2008 Resolved
Lights needed to be replaced in upper berthing area.
Due 29 February 2008
Resolved 29 January 2008
Resolution: Lights replaced in berths.
Fire Fighting › Portable Foam Applicators › General
Issued 29 January 2008 Resolved
Need 1 additional can of AFFF for carriage requirements on COI for MPT.
Due 29 February 2008
Resolved 29 January 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 January 2008 Resolved
Conduct man overboard drill with crew.
Due 29 February 2008
Resolved 30 January 2008
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 January 2008 Resolved
Provide FULL crew on board per COI requirements. Fax crew list along with copies of MMDs to office prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 January 2008 Resolved
Replace paint locker due to damage.
Due 29 February 2008
Resolved 2 June 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 January 2008 Resolved
Vessel needs an installed fire extinguishing system to comply with New T regulations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2008
Resolved 2 June 2008
Documentation › Certificates/Documents › International Load Line Certificate
Issued 28 October 2004 Resolved
Provide international load line certificate and international tonnage certificateprior to making international voyage.
Condition: Placed in Improper Service
Due 28 October 2004
Resolved 1 December 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 28 October 2004 Resolved
Replace dryer hose with metalic ducting.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 October 2004 Resolved
Remove extension cord from freezer.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 October 2004 Resolved
Provide CO2 extinguishers with correct hydrotest.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2004
Resolved 1 December 2004
Lifesaving › Emergency Outfit › Fire ax
Issued 28 October 2004 Resolved
Relocate fire axe to operating station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Engineering › Fuel Oil Service System › Valve
Issued 28 October 2004 Resolved
Repair fuel oil leaks to both main diesel engine fuel oil return line valves.
Condition: Improper/Lack of Maintenance
Due 28 November 2004
Resolved 17 November 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 October 2004 Resolved
Provide proper crimp type terminal lugs for generator batteries and properly block batteries with wood.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Fire Fighting › Fire Pumps › Power Source
Issued 28 October 2004 Resolved
Relocate fire pump control switch to operating station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 28 October 2004 Resolved
Secure starboard generator mounting bolts.
Condition: Improper/Lack of Maintenance
Due 28 November 2004
Resolved 17 November 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 October 2004 Resolved
Relocate audible bilge alarm to operating station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Stability › Weathertight Integrity › General
Issued 28 October 2004 Resolved
Regasket all watertight doors and watertight hatches. Properly adjust watertight door to galley.
Condition: Improper/Lack of Maintenance
Due 28 November 2004
Resolved 17 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 28 October 2004 Resolved
Repair oil leaks on port main diesel engine oil filters.
Condition: Improper/Lack of Maintenance
Due 28 November 2004
Resolved 17 November 2004
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 28 October 2004 Resolved
Seal pipe run from pump room to galley with fire stop.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 October 2004 Resolved
Provide locking device for power panels accessable to passengers.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 28 October 2004 Resolved
Properly mount guages at operating station.
Condition: Improper/Lack of Maintenance
Due 28 November 2004
Resolved 17 November 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 October 2004 Resolved
Properly mark liferings with Type II reflective tape.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Fire Fighting › Combustible Materials › Matresses
Issued 28 October 2004 Resolved
Provide evidence that passenger matresses comply with 46 CFR 177.405(g) prior to carrying overnight passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2004
Resolved 17 November 2004
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 October 2004 Resolved
Provide evidence of pre-employment drug tests for all crew members.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 October 2004 Resolved
Provide current crew list.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004
Documentation › Logs/Records › Logbook (official)
Issued 28 October 2004 Resolved
Provide details for crew training.
Condition: Placed in Improper Service
Due 28 November 2004
Resolved 17 November 2004

Casualty record · 2

12 August 2005Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2472460
4 February 2008Routine · role: Involved in a Marine Casualty · activity 3271078
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

TAYLOR CATHERINE (2005), MISS BROOKE (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.